Electric Range installation manual

Similar documents
INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

install o IIVIPORTANT - Savethese -&WARNING - -&WARNING - This appliance must -&WARNING - Before beginning the Mode_s PB970, PB975

For Use with Model(s):all electric models

INSTALLATIONINSTRUCTIONS FREESTANDINGELECTRICRANGE WITH DOUBLEOVENS

INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS

INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES

INSTALLATION INSTRUCTIONS FRONT CONTROL ELECTRIC RANGES

INSTALLATIONINSTRUCTIONS 30" (76 CM) FREESTANDINGELECTRICRANGES

Electric standing Range

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance.

SIDE VIEW. Maximum depth. fa_ro_ab_nne_se top. _25"--_. :ii! iii: i

Installation Instructions

I InstruCtIons. KiitchenAPd I. 30 Electric Freestanding Range IMPORTANT: Read and save these instructions. Part No Rev A

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

SLIDE-IN ELECTRIC RANGE

Installation Instructions

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

%-_. Quick Reference. TabJe of Contents: Before tou start Product dimensions. Cabinet dimensions requirements Electrical requirements

MASTERsine Inverter PXA Series Installation Guide

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

Installation Instructions

Pro Island Ventilation Hoods

Installation Instructions: Read these instructions in its entirety before performing any installation work.

I I. Model: DM301 DM302. C a _i'_ 3C 0 I. _M

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Pretest Module 24 Three-phase Service Entrance

Sconce INSTALLATION INSTRUCTIONS P B

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

Installation Instructions Studio Makeup Station

Sconce INSTALLATION INSTRUCTIONS P C

Florham Park, NJ USA Call (ASCO) for sales or service

INSTALLATION MANUAL. Melink Corporation (513) Revision

8300 Series Installation Guidelines

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

Company Switch Installation Instructions and User Manual

Installing Power Components

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code

SURFACE TRACK (120/250V) SPECIFICATIONS

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

30" (76.2 CM) AND 36" (91.4 CM) CLASSIC COMMERCIAL-STYLE DUAL FUEL CONVECTION RANGE WITH STEAM-ASSIST INSTALLATION INSTRUCTIONS

Electric. PN April Series Electric Oven

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

poollux Power plx-pw60 & plx-pw100

INSTALLATION AND OPERATING INSTRUCTIONS

5300 Series Installation Guidelines

SECTION PANELBOARDS

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

3.6 KVA IsoGuard. INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model 93 IXFMR3/6N A LT IXFMR36N 1. Issue 1 Print 1 SHORELINE ISOLATION TRANSFORMER

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

Viking Installation Guide

CHAPTER V RESIDENTIAL WIRING

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

ELECTRICAL. 60 Minutes

Air Conditioner for M915 A0/A1 Truck

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

Sconce INSTALLATION INSTRUCTIONS P34025

Sconce INSTALLATION INSTRUCTIONS P34024W

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Assembly Guide ELECTRIC. Model Numbers: C1. (English) /14/11

3.6 KVA IsoG2. INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model 93-ISOG26-A LT ISOG26 1. Issue 1 Print 3 SHORELINE ISOLATION TRANSFORMER

FOR INDOOR/SEASONAL USE ONLY

3.8 KVA IsoG2. INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model 93-ISOG2/8-A LT-ISOG28-1. Issue 1 Print 3 SHORELINE ISOLATION TRANSFORMER

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

This Automatic Transfer Switch with built-in Load Center includes an Express Install Kit.

Installation Manual. English. French

ABOVE-GROUND AUTOMATIC POOL COVER

SERVICE INSTRUCTIONS

INTEGRID TRACK (120V) SPECIFICATIONS

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL FRONT LOAD LOBBY UNIT PLAN VIEW FRONT VIEW SIDE VIEW

Automotive: Lightbars

assembly guide ELECTRIC Model Numbers: Estimated time required for assembly: 1 Hour (English) /02/10

FLO Home TM G5 Model. Installation guide

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

MONOGRAM 36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

PRO6.4, PRO6.4E, PRO9.0, PRO9.0E Generator Service Manual

MONOGRAM 36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR

RECESSED TRACK (120V) SPECIFICATIONS

FACT SHEET Standard: Electrical Safety

ABOVE-GROUND AUTOMATIC POOL COVERS

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

GFK-210-C Blower System - Installation and Operating Instructions -

ALL W INSTALLATION INSTRUCTIONS

EVoInnovate EVSE Model Numbers: EVO & EVO User Manual & Installation Guide. Revision 1.0

INSTRUCTIONS. Power Panel. Installation Instructions

MONOGRAM 36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR

Transcription:

Electric Range installation manual This manual is made with 100% recycled paper. imagine the possibilities ENGLISH Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register 1-800-SAMSUNG(726-7864) Installation-USA DG68-00108G-01_EN.indd 1 2012-02-16 11:14:21

before you begin ANTI-TIP DEVICE WARNING WARNING: To reduce the risk of tipping the appliance, the appliance must be secured by properly installed anti-tip devices packed with the appliance. a) A child or adult can tip the range and be killed. b) Install the anti-tip device to the structure and/or the range at rear right (or rear left) of the range bottom. c) Engage the range to the anti-tip device by leveling leg at rear right (or rear left) of the range bottom. d) Re-engage the anti-tip device if the range is moved. e) See installation instructions for details. f) Failure to do so can result in death or serious burns to children or adults. About this manual READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY. Important note to the installer Read all instructions contained in these installation instructions before installing range. Remove all packing materials from the oven compartments before connecting the electrical supply to the range. Observe all governing codes and ordinances. Be sure to leave these instructions with the consumer. Important note to the consumer Keep these instructions for the local electrical inspector s use. As when using any appliance generating heat, there are certain safety precautions you should follow. Be sure your range is installed and grounded properly by a qualified installer or service technician. Make sure the wall coverings around the range can withstand the heat generated by the range. To eliminate the need to reach over the surface elements, cabinet storage space above the elements should be avoided. The range should not be placed on a base. FOR YOUR SAFETY WARNING WARNING If the information in this manual is not followed exactly, a fire or electrical shock may result causing property damage, personal injury or death. WARNING WARNING Before beginning the installation, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. WARNING WARNING This appliance must be properly grounded. 2_ Before you begin Installation-USA DG68-00108G-01_EN.indd 2 2012-02-16 11:14:21

preparing to install the range REMOVE PACKAGING Remove packaging materials. Failure to remove packaging materials could result in damage to the appliance. PREPARE TOOLS & PARTS What tools you will need Drill Adjustable Wrench Pliers 1/4 Nut Driver Phillips Screwdriver Flat Screwdriver Pencil Level 01 PREPARING TO INSTALL What s included with your range Template Anti-Tip Bracket Screws (2 ea) What s not included 4-Wire Cord or 3-Wire Cord (UL Approved 40 or 50 AMP) Strain Relief (For Conduit Installation Only) Preparing to install the range _3 Installation-USA DG68-00108G-01_EN.indd 3 2012-02-16 11:14:22

ChECKING ThE INsTAllATIoN site Clearances and dimensions To install the range, refer to the following fi gure. For installation in CANADA, a Free-standing range is not to be installed closer than 12mm from any adjacent surface. CAUTION CAUTION This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194 F. Make sure the wall covering, countertops and cabinets around the range can withstand the heat (up to 194 F) generated by the range. If not, discoloration, delamination or melting may occur. 3 25 24 3 6 B 36 30 24 A A : Cabinet opening 30 For U.S.A, 30 ~31 For CANADA. B : Acceptable electrical outlet area Minimum dimensions IMPORTANT To eliminate the risk of burns or fi re caused by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 beyond the bottom of the cabinets. 30 * 30 ** 15 * 30 minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or 24 minimum when the bottom of the wood or metal cabinet is protected by not less than 1 /4 fl ame retardant millboard covered with not less than no.28 MSG sheet steel, 0.015 stainless steel, 0.024 aluminum or 0.020 copper. ** 15 minimum between the countertop and the adjacent cabinet bottom. 4_ Preparing to install the range Installation-USA DG68-00108G-01_EN.indd 4 2012-02-16 11:14:22

connecting the power step 1. meeting ElECTRICAl CoNNECTIoN REQuIREmENTs CAUTION CAUTION For personal safety, do not use an extension cord with this appliance. Remove house fuse or open circuit breaker before beginning installation. This appliance must be supplied with the proper voltage and frequency, and connected to an individual properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as specifi ed on the rating plate. The rating plate is located above the drawer on the oven frame. (Fig. 1 or Fig. 2) We recommend you have the electrical wiring and hookup of your range connected by a qualifi ed electrician. After installation, have the electrician show you where your main range disconnect is located. Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven according to governing codes could result in a hazardous condition. If there are no local codes, your range must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70 Latest Edition. You can get a copy by writing: National Fire Protection Association Batterymarch Park Quincy, MA 02269 (Fig. 1) 02 CONNECTING THE POWER (Fig. 2) Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) utilize a 4-conductor connection to an electric range. When installing an electric range in new construction, follow Steps 2 and 3 for 4-wire connection. You must use a 3-wire or 4-wire, single-phase A.C. 208Y/120 Volt or 240/120 Volt, 60 hertz electrical system. If the electrical service provided does not meet the above specifi cations, have a licensed electrician install an approved outlet. Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with ring terminals on wire and a strain relief device. A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range cord is not recommended but if used, it should be marked for use with nominal 1 3 8 diameter connection openings. Care should be taken to center the cable and strain relief within the knockout hole to keep the edge from damaging the cable. Because range terminals are not accessible after range is in position, fl exible service conduit or cord must be used. NOTE If conduit is being used, go to Step 4 on page 9. ALL NEW BRANCH-CIRCUIT CONSTRUCTIONS, MOBILE HOMES, RECREATIONAL VEHICLES AND INSTALLATIONS WHERE LOCAL CODES DO NOT ALLOW GROUNDING THROUGH NEUTRAL, REQUIRE A 4-CONDUCTOR UL-LISTED RANGE CORD. Connecting the power _5 Installation-USA DG68-00108G-01_EN.indd 5 2012-02-16 11:14:23

step 2. ACCEssING ThE PoWER CoRD CoNNECTIoN Remove the rear access cover and loosen the screw with a screwdriver. The terminal block will then be accessible. Terminal block Access cover Specifi ed power-supply-cord kit rating Range rating, watts 120/240 volts 3-wire 120/208 volts 3-wire Specifi ed rating of power-supply-cord kit, amperes Diameter (inches) of range connection opening Power cord Conduit 8,750-16,500 7,801-12,500 40 or 50A 1 3 /8 1 1 /8 6_ Connecting the power Installation-USA DG68-00108G-01_EN.indd 6 2012-02-16 11:14:24

step 3. INsTAllING ThE PoWER CoRD For power cord installations, hook the strain relief over the power cord hole (1 3 /8 ) located below the rear of the drawer body. Insert the power cord through the strain relief and tighten the device. Conduit connection plate Power cord Strain relief You must install the power cord with a strain relief. Attach the strain relief to the 1 3 /8 opening in conduit connection plate. Installing a 3-wire power cord 02 CONNECTING THE POWER WARNING WARNING The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. 1. Remove the 3 lower terminal screws from the terminal block. 2. Insert the 3 terminal screws through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. 3. Tighten screws securely into the terminal block. DO NOT remove the ground strap connection. 4. Go to step 5 on page 10 and proceed with the installation. Neutral terminal Ground strap Connecting the power _7 Installation-USA DG68-00108G-01_EN.indd 7 2012-02-16 11:14:25

Installing a 4-wire power cord WARNING WARNING The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. The 4th grounding lead must be connected to the frame of the range with the ground plate and the ground screw. 1. Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them. 2. Cut and discard the ground strap. Do not discard any screws. 3. Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate, and into the frame of the range. 4. Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten screws securely into the terminal block. 5. Go to step 5 on page 10 and proceed with the installation. Neutral terminal Ground strap Ground plate Ground screw Ground wire (Green) 8_ Connecting the power Installation-USA DG68-00108G-01_EN.indd 8 2012-02-16 11:14:26

step 4. INsTAllING ThE CoNDuIT Remove the conduit connection plate from the rear of the drawer body and rotate it as shown below. The conduit hole (1 1 /8 ) must be used. 1 1 /8 1 3 /8 1 3 /8 1 1 /8 1. Prepare the conduit cord shown in Figure 1. 2. Install the conduit cord as shown in Figure 2. Figure 1 1 3/8 1 3/8 3 1 /2 3 1 /2 3 wire 4 wire Knockout surface Conduit connection plate Figure 2 Ring Body Strain relief 02 CONNECTING THE POWER For conduit installations, insert the strain relief (not included) into the conduit hole (1 1 /8 ). Then thread the conduit cord through the body of the strain relief and fasten the ring. Reinstall the bracket. Installing a 3-wire conduit Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make the connection. Connect wires according to Step 4 depending on the number of wires. Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes. 1. Loosen the 3 lower terminal screws from the terminal block. 2. Insert the center bare wire (white/neutral) tip through the bottom center terminal block opening. On certain models, the wire will need to be inserted through the ground strap opening and then into the bottom center block opening. 3. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. 4. Tighten the screws until the wire is fi rmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws since it could damage the wires. 5. Go to step 5 on page 10 and proceed with the installation. Neutral terminal Wire tips Ground strap Connecting the power _9 Installation-USA DG68-00108G-01_EN.indd 9 2012-02-16 11:14:27

Installing a 4-wire conduit Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make the connection. Connect wires according to this Step 4 depending on the number of wires. Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes. 1. Loosen the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them. 2. Cut and discard the ground strap. Do not discard any screws. 3. Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw (removed earlier). 4. Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening. 5. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. 6. Tighten the screws until the wire is fi rmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws since it could damage the wires. 7. Go to step 5 and proceed with the installation. Neutral terminal Ground strap Ground plate Wire tips Ground wire (Green) step 5. REPlACING ThE ACCEss CoVER Replace the access cover on the range back. To replace the wire cover, insert double projections in the pockets located below the opening and tighten the screw. 10_ Connecting the power Installation-USA DG68-00108G-01_EN.indd 10 2012-02-16 11:14:28

installing the range INsTAllING ThE ANTI-TIP DEVICE WARNING WARNING To reduce the risk of tipping, the appliance must be secured by properly installing the Anti-Tip device packed with the appliance. Refer to the installation instructions supplied with the bracket. Unless properly installed, the range could be tipped by stepping or sitting on the door. Injury may result from spilled hot liquids or from the range itself. *approximately 21/32 (16.5mm) Screw must enter wood or concrete Anti-Tip bracket *NOTE: To install Anti-Tip bracket, release the leveling leg. A minimum clearance of 21/32 (16.5mm) is required between the range bottom and the kitchen fl oor. 03 INSTALLING THE RANGE 1. Locate the bracket using the template The Anti-Tip bracket is packaged with a template. The instructions include information necessary to complete the installation. Read and follow the instructions on the sheet (template) for range installation. 2. Level the range Level the range by adjusting the leveling legs with a wrench. Raise range Lower range Leveling leg Installing the range _11 Installation-USA DG68-00108G-01_EN.indd 11 2012-02-16 11:14:29

3. Check your adjustments Use a spirit level to check your adjustments. Place the level diagonally on the oven rack or surface cooktop, and check each direction for level. 1. Check direction 1. 2. Check direction 2. If the spirit level doesn t show level on the oven rack or surface cooktop, adjust the leveling legs with a wrench. FINAlIZING ThE INsTAllATIoN Move range close enough to the opening to plug into the receptacle. Slide range into position insuring that the rear left(or rear right) leg slides under the Anti-Tip bracket. The range will sit 0 away from the back wall when properly installed. Carefully tip the range forward to insure that the Anti-Tip bracket engages the back brace and prevents tip-over. Turn on the electrical power. Check the range for proper operation as described in the user manual. Anti-Tip bracket Leveling leg 12_ Installing the range DG68-00108G-01 Installation-USA DG68-00108G-01_EN.indd 12 2012-02-16 11:14:29