CONTINENTAL HYDRAULICS VAD05M-VMD05M - AIR & LEVER OPERATED DIRECTIONAL VALVES

Similar documents
VAD03M-VPD03M- VMD03M

VSD05M-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES

CONTINENTAL HYDRAULICS F03MSV-ND* FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F03MSV-ND* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

VER*SP CONTINENTAL HYDRAULICS PROPORTIONAL PILOT RELIEF VALVES VER*SP - PROPORTIONAL PILOT RELIEF VALVES

VER03M CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES VER03M - PROPORTIONAL PRESSURE RELIEF VALVES

VEP03MSV-PDRP CONTINENTAL HYDRAULICS 3-WAY PROPORTIONAL PRESSURE REDUCING/RELIEVING VALVES

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED

VEP03MSV-PDRP -3-WAY PROPORTIONAL PRESSURE REDUCING/RELIEVING VALVES

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

VSD*S -MONITORED DIRECTIONAL CONTROL VALVES

VED*MG - PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK

CONTINENTAL HYDRAULICS VED03MX

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

VED*MJ PILOT OPERATED DIRECTIONAL CONTROL VALVES WITH OBE & FEEDBACK

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

VSD*HL-*-KD2 - HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES

CONTINENTAL HYDRAULICS LPV SERIES AXIAL PISTON PUMPS

PILOT OPERATED PRESSURE RELIEF VALVE SERIES - IN-LINE MOUNTING

CONTINENTAL HYDRAULICS PVER VANE PUMPS

DSH* /117 ED LEVER OPERATED DIRECTIONAL CONTROL VALVE MOUNTING SURFACES DSH3 ISO DSH5 ISO

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

D05 Directional Control Valves

Directional Control Valves

Pressure Control Valves

RS* /110 ED DOUBLE-ACTING THROTTLE FLOW CONTROL VALVE SERIES 30. Q max (see table of performances) THREADED PORTS CARTRIDGE TYPE

VPN2-10/MR. Functional Description HU /2008. Pilot Operated Pressure Relief Valves. Replaces HU /2005

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

PowerFlow D03 Directional Control Valves

Q max (see specifications table)

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Directional Control Valve Series 4D01 (DENISON)

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

Directional Controls

PILOT OPERATED PRESSURE REDUCING VALVE TYPE DR

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Pressure reducing valve, direct operated

Cartridge Valves Technical Information Directional Valves DCV 03

p max 350 bar Q max 50 l/min bar bar 50 Ports dimensions: P - port (pressure) T - port (drainage) T - port (drainage) A/B - port l/min

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

Directional Control Valve Series D3W Soft Shift

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

DXPE*J /117 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 31

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

Pressure relief valve, pilot operated

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Controls

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

Documentatie Stuurventielen DL3

VJL Functional Description. Ordering Code VJL Spare Parts HA /2002. Logical 3-way check valves. Replaces HA /2001

Directional spool valves, direct operated, with solenoid actuation. Type WE

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

PACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE.

PVD /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER OPERATING PRINCIPLE

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents

Directional spool valve type WMM 16 hand lever operated

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

Check valve, pilot operated

Directional Valves. Pilot Operated Directional Valves. Vickers. Service Data

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description

(F*) - DG5V -10- * - (R) - (B) - **(L) - (**) - (X) - (*) - (E) - (T) - (*) - (V)M - (S*) - * ** * * (L) - (*) ** - (***) (EN***)

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMC 045. Staffa Fixed Displacement Hydraulic Motor

Directional Control Valve Series D1VW

Check valve, pilot operated

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

Pressure Relief Valves

Check valve, pilot operated

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

Available manual, pneumatic, and hydraulic spool control kits.

Transcription:

CONTINENTAL HYDRAULICS VAD05M-VMD05M AIR & LEVER OPERTAED DIRECTIONAL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM

VAD05M-VMD05M AIR & LEVER OPERATED DIRECTIONAL VALVES DESCRIPTION The directional control valve with air pilot actuation conforms to valve NFPA D05 alt A mounting standard. The hand lever actuation conforms to NFPA D05. They are available in both 3 way and 4 way styles. All versions are available in 2 position spring offset, 2 position detent, 2 position spring centered and 3 position spring centered versions. The lever valve also is available in a 3 position detent model. A wide range of spools for different requirements are available. TYPICAL PERFORMANCE SPECIFICATIONS MAXIMUM OPERATING PRESSURE P, A, B PORTS T PORT VA, VM 4600 psi 320 bar VM VA internal drain VA external drain 2300 psi 360 psi 4600 psi 160 bar 25 bar 320 bar NOTE VAD05M: The Y external drain is available (STD) for the ISO 4401-05 size (CETOP R05 - D05 type A) and it must be connected when there is a backpressure higher than 25 bar (360 psi) on the T port. An adapter may be required to block off Y port on STD bar manifolds. See page 11. MAXIMUM PILOT PRESSURE MINIMUM PILOT PRESSURE FLOW RATE MAXIMUM WEIGHT VA 175 psi 12 bar VA 65 psi 4.5 bar VA 32 gpm 120 l/min VM 33 gpm 125 l/min VA Single Op. 7.0 lbs 3.2 kg VA Dual Op. 8.8 lbs 4.0 kg VM - Lever 9.3 lbs 4.2 kg RANGE TEMPERATURES FLUID VISCOSITY Ambient - 4 to +130 F -20 to +54 C Fluid - 4 to +180 F -20 to +82 C Range 60-1900 SUS 10-400 cst Recommended 120 SUS 25 cst FLUID CONTAMINATION ISO 4406:1999 Class 20/18/15 2 WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

IDENTIFICATION CODE A M 1 2 OPERATOR V D05M - - - 10 - Air Lever FUNCTION FOR AIR OPERATOR Single Operator 2 Position Spring Offset Dual Operator 2 Position Detented (No Spring) 1 2 FUNCTION FOR LEVER OPERATOR Lever Operator 2 Position Spring Offset Lever Operator 2 Offset Position Detented (No Spring) SPOOL TYPE See page 4 & 5 A G SEAL Buna (STD) Viton R DESIGN LETTER Operator MECHANICAL OMIT IF NOT REQUIRED Operator at B port end. Available only with functions 1, 5 and 9. Not available on lever valve 3 Dual Operator 3 Position Spring Centered 3 Lever Operator 3 Position Spring Centered 5 Single Operator 2 Position Spring Centered 4 Lever Operator 3 Position Detented (No Spring) 9 Single Operator 2 Position - 3 Way Spring Offset 5 Lever Operator 2 Position Spring Centered NOTE: Spool code 9X must have the T port connected to tank. 9 Lever Operator 2 Position 3 Way Spring Offset 25 Lever Operator 2 Position Detented (No Spring) TYPICAL ORDERING CODE: VAD05M-3A-A-10-A VMD05M-3A-A-10-B SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM 3

VAD05M SPOOLS NAME SYMBOL FUNCTION CENTER POSITION CROSSOVER FUNCTION MATCHING A A1 All ports blocked All ports blocked P B or P A T blocked P B and A T restricted or P A and B T restricted B All ports open All ports open 1, 2, 3, 5 E F F1 G H P and A blocked and B T P blocked, A T and B T P blocked, A and B restricted to T P to A and B T blocked P and A to T B blocked All ports blocked or P and A blocked and B T P blocked and A T or B T P blocked, A or B restricted to T P B or P A T blocked All ports open, restricted 1, 2, 3, 5 3, 5 3, 5 K P and B blocked, and A T P and B blocked and A T or all ports blocked L P T, A and B blocked All ports open, restricted Q P and B to T, A blocked All ports open, restricted X - All ports blocked 9 These are the standard configurations. Contact Continental Hydraulics for special versions. 4 WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

VMD05M SPOOLS NAME SYMBOL FUNCTION CENTER POSITION CROSSOVER FUNCTION MATCHING A All ports blocked P B or P A T blocked B All ports open All ports open F L P blocked, A T and B T P T, A and B blocked P blocked and A T or B T All ports open, restricted X - All ports blocked 2, 9 These are the standard configurations. Contact Continental Hydraulics for special versions. 1, 3, 4, 5, 25 3, 4, 5, 25 SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM 5

PRESSURE DROPS P-Q SHIFTED VALVE (OBTAINED WITH VISCOSITY OF 170 SUS - 36 CST AT 70 F - 50 C) FLOW CURVE NUMBER SPOOL SHIFTED P A P B A T B T A, A1 2 2 1 1 B 3 3 1 1 E, F, F1, K 3 3 2 2 H, L, Q 1 1 2 2 1A 3 3 2 2 G 1 1 1 1 PRESSURE DROPS P-Q CENTRAL POSITION (OBTAINED WITH VISCOSITY OF 170 SUS - 36 CST AT 70 F - 50 C) FLOW CURVE NUMBER SPOOL SHIFTED P A P B A T B T P T B - - - - 5 F - - 6 6 - H, L, Q - - - - 5 E - - - 6 - G 3 3 - - - K - - 6 - - 6 WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

PERFORMANCE CURVE VAD05M VMD05M CURVE SPOOL 1 A, B 2 1A, 1B 3 F 4 L NOTES: For spool F and 1A, the curve has been obtained with a minimum piloting pressure of 4.5 bar (65 psi). If the minimum piloting pressure used is 5.5 bar (80 psi), refer to curve 1. CURVE SPOOL 1 A, B, F 2 L 3 4L NOTES: 1. Valve performance was tested in a four way circuit (full loop). Performances may be reduced from that shown when used in a three-way circuit (half circuit), i.e. A or B port plugged. 2. The values have been obtained according to ISO 6403 norm with filtration according to ISO 4406:1999 class 18/16/13. SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM 7

OVERALL AND MOUNTING DIMENSIONS FOR AIR OPERATED VALVE VAD05M-2*, 3* Hexagon: 38 mm [1 1/2 ] wrench Tightening torque: 25-30 lb.ft (35-40 Nm) Dimensions in mm [IN] SAE 04 7/16-20 UNF connection for operator Mounting surface with sealing rings: 5 pcs. AS568-014 90 Shore A VAD05M-1*, 5*, 9* VAD05M-1*-R, 5*-R, 9*-R 8 WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

OVERALL AND MOUNTING DIMENSIONS FOR LEVER OPERATED VALVE VMD05M PUSH Dimensions in mm [IN] On 2- position valves push only to shift the valve Mounting surface with sealing rings: 5 pcs. AS568-014 90 Shore A PUSH PULL On 3- position valves, pulling the lever obtains the right position, pushing the lever obtains the left position SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM 9

MOUNTING SURFACES ALL THE MOUNTING SURFACES REFER TO NFPA T3.5.1 R2-2002 AND ISO 4401:2005 STANDARDS. The mounting surface standards recommends metric coarse threads. However, subplates are commercially available with UNC threads. Select a bolt size that matches the threads in the mounting surface. Dimensional tolerances are ± 0.1 mm (0.004 ) for bolt and pin location; ± 0.2 mm (0.008 ) for the other quotes. D05 (for VMD05M valve) PORT FUNCTION: P = PRESSURE PORT T = TANK PORT A = FIRST CYLINDER PORT B = SECOND CYLINDER PORT MM INCH MM INCH MM INCH P, A, B, T MAX Ø 11.2 Ø 0.44 MOUNTNG BOLT THREAD SIZE M6 1/4-20 UNC A 90.0 3.54 B 58.0 2.28 C 3.20 0.126 E 16.7 0.66 F 27.0 1.06 G 37.3 1.47 J 54.0 2.125 L 6.30 0.25 M 11.2 0.44 N 21.4 0.84 O 32.5 1.28 P 46.0 1.82 10 WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

D05 - ALTERNATIVE A (for VAD05M valve) PORT FUNCTION: P = PRESSURE PORT A = FIRST CYLINDER PORT B = SECOND CYLINDER PORT T = TANK PORT X = PILOT PORT Y = DRAIN PORT MM INCH MM INCH MM INCH P, A, B, T MAX Ø 11.2 Ø 0.44 X, Y ALT. A Ø 6.30 Ø 0.25 A 90.0 3.54 B 58.0 2.28 C 3.20 0.126 J 54.0 2.125 K 62.0 2.44 L 6.30 0.25 MOUNTNG BOLT THREAD SIZE M6 1/4-20 UNC D 8.00 0.31 E 16.7 0.66 F 27.0 1.06 M 11.2 0.44 N 21.4 0.84 O 32.5 1.28 G 37.3 1.47 P 46.0 1.82 NOTES: NFPA D05 and ISO 4401-05 indicates different diameters for X and Y holes: NFPA: Ø 9.6 max in D05 alt A ISO: Ø 6.3 max SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM 11

APPLICATION DATA FLUIDS All pressure drops shown on these data pages are based on 170 SUS fluid viscosity and 0.87 specific gravity. For any other specific gravity (G1) the pressure drop ( P) will be approx. P1 = P (G1/G). See the chart for other viscosities. FLUID VISCOSITIES Cst 10 14.5 32 36 43 54 65 76 86 108 216 324 400 SUS 60 75 150 170 200 250 300 350 400 500 1000 1500 1900 MULTIPIER 0.77 0.81 0.97 1.00 1.04 1.10 1.15 1.20 1.24 1.31 1.56 1.72 1.83 Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type (phosphate esters) use FPM seals (code G). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical department. Using fluids at temperatures higher than 180 degrees F causes the accelerated degradation of seals as well as the degradation of the fluids physical and chemical properties. From a safety standpoint, temperatures above 130 degrees F are not recommended. RANGE TEMPERATURES FLUID VISCOSITY Ambient - 4 to +130 F -20 to +54 C Fluid - 4 to +180 F -20 to +82 C Range 60-1900 SUS 10-400 cst Recommended 120 SUS 25 cst FLUID CONTAMINATION ISO 4406:1999 Class 20/18/15 INSTALLATION The configurations with centering and return springs can be mounted in any position without impairing correct operation. Valves are fixed by means of screws or tie rods on a flat surface with planarity and roughness equal to or better than those indicated in the relative symbols. If minimum values are not observed, fluid can easily leak between the valve and support surface. 12 WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

SEAL KIT Buna Seal Kit for VAD05M 1015696 Viton Seal Kit for VAD05M 1015697 Buna Seal Kit for VMD05M 1015698 Viton Seal Kit for VMD05M 1015699 BOLT KIT BD05-163 valve only 1013160 TAPPING PLATE KIT FOR VAD05M DES A P/N 1016562 for use with standard D05 bar type manifold Tapping plate blocks the Y drain port to prevent leakage. Y drain port will hang over the edge on narrow manifolds. In this application, use a tapping plate kit under the directional control valve to block the port. Use a manifold with a D05 alt A mounting pattern for applications where the drain port is required. ITEM P/N DESCRIPTION Q.TY 1 351706AH DD05TPPT4S 1 2 198250 Scr Soc Head Cap 1/4"-20 x 2.75" 4 3 003559 1/4" Hi collar lock washer 4 4 260118 SAE 04 hex soc head plug 2 5 1016563 kit literature 1 SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM 13

ABOUT CONTINENTAL HYDRAULICS Rugged, durable, high-performance, efficient the reason Continental Hydraulics products are used in some of the most challenging applications across the globe. With a commitment to quality customer support and innovative engineering, Continental s pumps, valves, power units, mobile and custom products deliver what the markets demand. Continental has been serving the food production, brick and block, wood products, automotive and machine tool industries since 1962. Learn how our products survive some of the most harsh environments. SALES@CONTHYD.COM 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / FAX: 952.895.6444 / WWW.CONTINENTALHYDRAULICS.COM FORM NO. 1015701. REV. 09/2014. 2014 CONTINENTAL HYDRAULICS. ALL RIGHTS RESERVED. PRODUCT SPECIFICATIONS AND APPEARANCE ARE SUBJECT TO CHANGE WITHOUT NOTICE.