Actuators for Fire and Smoke Protection Dampers

Similar documents
Actuators for Fire and Smoke Protection Dampers

Actuators for Fire and Smoke Protection Dampers

Actuators for Fire Protection Dampers

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

Air damper actuators

GDB..3..1A GLB..3..1A

Air damper actuators

MF /MS Series

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners

Electromotoric Actuators

Electromotoric Actuators

Technical Instructions Document No P25 EA GMA May 19, OpenAir. GMA Series, Spring Return, 62 lb-in, Rotary, Electronic Damper Actuators

Technical Instructions Document No P25 EA GMA January 19, OpenAir. GMA Series Spring Return Rotary Electronic Damper Actuators

Actuators for air dampers and control valves of oil burners

Commercial Actuator Selection Chart Non-Spring Return

For air dampers and control valves of oil or gas burners

Electromotoric Actuators

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

Differential Pressure Sensors

S1024-2POS / S POS S2024-2POS / S POS

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

Differential Pressure Sensors

Electromotoric Actuators

Electromotoric actuators

Pressure Sensors. for liquid and gaseous media

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

Temperature Controller (Heat Pumps)

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

Actuators for Air and Gas Dampers

2-position electric actuators with Ball valves VBZ ½...11/4

Differential Pressure Sensors

SmartX MF and MS

Electro-hydraulic actuators for valves

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Electromotoric actuators

Rotary actuators for ball valves

Differential Pressure Sensors

Actuators for air and gas dampers

Actuators for small valves

SAX Electronic Valve Actuator

Actuators for Air and Gas Dampers

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Differential pressure sensor

OpenAir. Technical Instructions. GCA Series Spring Return 160 lb-in Electronic Damper Actuators. Document No P25 EA GCA-1.

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

DC-132 Non Spring Return Electronic Actuator Series

OpenAir GCA Series Spring Return 142 lb-in Electronic Damper Actuators

Electromotoric Actuators

Electrical Actuators

Electronic Ignition Equipment

Overview of types. Technical data. Safety notes

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

For air / gas dampers and control valves of oil or gas burners

SAV Electronic Valve Actuator

MF Series MS Series

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

SQN9... Damper Actuators. Building Technologies HVAC Products. SQN9..., front (covers removed) SQN9..., rear (covers fitted)

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) ES142 Spring Return Electronic Actuators

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

Modulating control valves with magnetic actuators, PN 16

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Master/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Pressure sensor for liquid and gaseous media QBE620-P...

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

DC/DC converters - MINI-PS DC/ 5-15DC/

FSAF24(-S) US, FSAF120(-S) US

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Actuators. Building Technologies Division

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

Electric actuators for small valves

Power consumption In operation At rest For wire sizing

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Transcription:

4 617 OpenAir TM Actuators for Fire and Smoke Protection Dampers GGA126.1E/.. GGA326.1E/.. Electric motor driven actuators for 2-position control, nominal torque 18 Nm, with spring return to failsafe position, mechanically adjustable span between 0...90, prewired with 0.9 m long connecting cables Operating voltage AC 24 V / DC 24 48 V or AC 230 V Optional temperature with 3 thermal cutouts (72 C) and test button. Fixed auxiliary switches for switching points 5 and 80 Rigid connection between actuator and damper shaft. Use For the control of fire and smoke protection dampers. Nominal torque of 18 Nm for damper surfaces up to about 2.5 m 2 (frictiondependent) In fire protection sections of plant where, in the event the thermal fuse cuts out at a duct or ambient temperature of 72 C, or in case of a power failure, the actuator must travel to the failsafe position (zero position) CE1N4617en 07.06.2013 Building Technologies

Functions Basic functions Rotary movement Failsafe function Behavior in the event the damper is blocked Position indication Manual adjustment when actuator is dead Rigid connection Direction of rotation (clockwise or counterclockwise) determined by the way the actuator is mounted on the damper shaft When operating voltage is applied, the actuator travels toward the 90 position If the thermal fuse cuts out at a duct or ambient temperature of 72 C (Optional: 95 C), the return spring drives the actuator to the failsafe position (0 ) In the event of a power failure or if the operating voltage is turned off, the return spring drives the actuator to the failsafe position (0 ) The actuator is equipped with an automatic switch-off mechanism. The position indicator located on the shaft adapter shows the rotational angle position of the damper blade. When dead, the actuator can be driven to any angular position using a hex wrench and can then be secured with a screwdriver The actuator returns to its zero position when mechanically delocked with a hex wrench (turning toward "90 - opening") or by applying power for a short moment Square shafts 10 x 10 or 12 x 12 mm Type summary Operating voltage AC 24 V DC 24 48 V Auxiliary switches Fixed switching points at 5 and 80 AC 230 V Fixed switching points at 5 and 80 With temperature GGA126.1E/T10 GGA126.1E/T12 GGA326.1E/T10 GGA326.1E/T12 Without temperature monitoring unit GGA126.1E/10 GGA126.1E/12 GGA326.1E/10 GGA326.1E/12 Delivery Connecting cables Due to the mounting choices depending on the direction of rotation and the shaft length, shaft adapter with position indicator and other mounting accessories are shipped unassembled together with the actuator. The actuators come with 0.9 m long prewired connecting cables. The cable length to the ready fitted temperature is 0.9 m. Accessories Designation Type reference Data sheet / mounting instruction Duct tip to temperature ASK79.4 / 72 C N4617 / M4610 monotoring unit ASK79.5 / 95 C 2/10 Siemens Actuators for fire and smoke protection dampers GGA126.1E/.., GGA326.1E/.. CE1N4617en

Equipment combinations The damper actuators can be used with all types of controllers having a 2-position output and delivering a switching voltage of AC 24 V / DC24 48 V or AC 230 V. Technical design Drive motor Spring return mechanism in the event of power failure The brushless DC motor ensures accurate speed control, torque monitoring for protecting the actuator and the air damper, and provides a reliable failsafe function. Mechanical spring ensure the failsafe function. Mechanical design Basic components Housing Gear train Spring preload Manual adjustment Mounting bracket Electrical connection Note Auxiliary switches Robust, lightweight all metal housing made from die-cast aluminium which guarantees long service life even under extreme environmental conditions. Maintenance- and noise-free gear train with stall and overload protection for the life of the actuator. The spring has a factory-set preload of 5 to ensure tight shutoff for the fire and smoke protection dampers. A hole with a screw in the center of the actuator allows manual setting of the gears. A hex wrench is supplied. A perforated bracket with pin available, depending on the way the actuator is fixed. All actuators come with prewired 0.9 m long connecting cables. The actuator can be mounted on either side depending on the required direction of rotation. All setting and operating elements are available on both sides of the actuator. Fixed switching points at 5 and 80. Use The temperature is ready connected to the actuator and is used for forced control of motorized fire and smoke protection dampers should excessive temperatures occur. Mode of operation The temperature contains 3 thermal fuses, two for monitoring the duct temperature and one for the ambient temperature. If the temperature at any of these fuses exceeds the level of 72 C (Optional: 95 C), the power supply will be irreversibly cut. As a result, the return spring will drive the actuator to the failsafe position. A test button is integrated for making functional checks. When pressed, the current path will be cut. LED functions Red = Operating voltage OK. Thermo sensor defect Green = Operating voltage OK Thermo sensor OK Dark = No operating voltage Siemens Air damper actuators GGA126.1E/.., GGA326.1E/.. CE1N4617en 3/10

Setting and operating elements Refer to "Technical design" and "Commissioning notes" in this data sheet. 1 Housing 2 Angle of rotation scale 0...90 3 Screw for manual override 4 Connecting cable for power supply 5 Connecting cable for auxiliary switches 6 Stop shaft for geartrain 7 Position indicator 8 Shaft adapter 9 Locking ring for shaft adapter 10 Adapter for position indicator 11 12 Mounting bracket 13 Pin Arrangement for shaft adapters 9 8 10 7 4617Z40 4/10 Siemens Actuators for fire and smoke protection dampers GGA126.1E/.., GGA326.1E/.. CE1N4617en

Engineering notes STOP Correct use Power supply AC 24 V DC 24 48 V Power supply AC 230 V Auxiliary switches A, B Warning, maintenance Parallel connection of actuators Sizing transformers for AC 24 V Wiring and commissioning The basic system data for the control systems in use contain all engineering notes. Read all the engineering notes before mounting, wiring and commissioning the damper actuator and pay special attention to all safety instructions. These damper actuators must be used on applications as described in the basic system data documents for the relevant control systems. Additionally, all actuator-specific features and rules must be observed as described in the brief description on the front page of this Data Sheet (bold print) and in "Use", "Engineering notes", and "Technical data". All paragraphs marked with the special warning triangle as illustrated on the left contain additional safety instructions and limitations that must be observed under any circumstances to avoid physical injuries or damage to equipment. These actuators must be used with safety extra low-voltage (SELV) or protection by extra low-voltage (PELV) in accordance with HD 384. The actuators are double-insulated and do not provide a connection for protective ground. Use either mains voltage or safety extra low-voltage for auxiliary switches A and B. Do not mix the 2 for operation. Operation with different phases is not permitted. Do not open the actuator! The actuator is maintenance-free. Maintenance work may only be carried out by the manufacturer. Electric parallel connection of the same types of actuator is permitted provided operating voltage is within the required tolerance. Voltage drops on the supply lines must be taken into consideration Use safety isolating transformers with double insulation conforming to EN 60 742. The transformers must be suited for 100 % duty Observe all local safety rules and regulations relating to the sizing and protection of transformers Determine the transformer s size by adding up the power consumption in VA of all actuators used Refer to "Commissioning notes" and "Internal diagram" as well as to the plant diagram. Mounting notes Mounting instructions Housing protection Mounting bracket / pin For detailed information on the correct preparation of the actuator, refer to Mounting Instructions GGA 1E/.. M4617. The actuator must be fitted to the fire and smoke protection damper as specified by the OEM. Shaft adapter and other accessory items come unassembled, since their assembly depends on the direction of rotation and the length of the shaft (refer to Technical design ). In order to comply with the requirements of IP54 (temperature has IP54), the following mounting conditions must be satisfied: Always mount the actuator vertically (cable entry at the bottom) in the case of air dampers with horizontal shafts When the actuator is mounted directly on the damper shaft, the mounting angle may be a maximum of +/ 45 If the actuator is mounted directly on the damper shaft, the mounting bracket / pin must be used. The insertion depth for the shaft into the housing must be sufficient. Siemens Air damper actuators GGA126.1E/.., GGA326.1E/.. CE1N4617en 5/10

Damper shafts Spring preload Mechanical limitation of the rotational angle For information on minimum length and diameter of the damper shaft, refer to "Technical data". The actuator is supplied with a 5 spring preload to ensure a certain closing pressure for the air damper. If required, the angle of rotation can be limited in increments of 5 for the entire correcting span by placing the shaft adapter in the respective position. The temperature is to be fitted to the duct wall or the damper housing using 2 self-tapping screws of 3.5 mm diameter. The enclosed drilling template facilitates mounting. When mounting, it must be ensured that the thermal fuse is fully exposed to the airflow. Commissioning notes References Environmental conditions Mechanical check Electrical check All information required for commissioning is contained in the following pieces of documentation: The present Data Sheet N4617 Mounting Instructions M4617 Plant diagram Check to ensure that all permissible values as specified in "Technical data" are observed Check for proper mounting to ensure that all mechanical settings are in accordance with plant-specific requirements. In addition, ensure that the air dampers are shut tight when in the fully closed position Fasten the actuator securely to avoid side load Check the direction of rotation by turning the gearing with a hex wrench in accordance with the Mounting Instructions Check to ensure that the cables are connected in accordance with the plant wiring diagram Operating voltage AC 24 V / DC 24 48 V (SELV / PELV) or AC 230 V must be within the tolerance Auxiliary switches "A" and "B" change over when the actuator reaches the respective positions Functional check on site: Press the button to simulate overtemperature. This simulates the response of the fuse, enabling you to check the proper functioning of the actuator. In plant equipped with a fire alarm device BAM, fire alarm will be triggered. Appropriate measures must be taken before the functional check is made. 6/10 Siemens Actuators for fire and smoke protection dampers GGA126.1E/.., GGA326.1E/.. CE1N4617en

Technical data Power supply AC 24 V DC 24...48 V (SELV/PELV) Power supply AC 230 V Mechanical data Auxiliary switches Connecting cables (halogen free) Degree of protection Environmental conditions Standards and directives Operating voltage AC / frequency Operating voltage (DC) Power consumption GGA126.1: when running when running when holding when holding Safety class Operating voltage / frequency Power consumption GGA326.1: when running when holding Safety class Nominal torque Maximum torque (blocked) Nominal angle of rotation / maximum angle of rotation Running time for nominal angle of rotation 90 (motor operation) Closing with spring return (on power failure) AC power supply Switching voltage Nominal current res./ind. Life: 6 A res., 2 A ind. without load DC power supply Switching voltage Nominal current Electric strength auxiliary switch against housing Switching hysteresis Factory switch setting Switch A Switch B Power supply line AC 24 V (wires 1-2) AC 230 V (wires 3-4) Auxiliary switch cable (wires S1 S6) Standard length AC 24 V ±20 % / 50/60 Hz DC 24...48 V ±20 % AC: 7 VA / 5 W DC: 4 W AC: 5 VA / 3 W DC: 3 W III to EN 60 730 AC 230 V ±15 % 50/60 Hz 8 VA / 6 W 6 VA / 4 W II to EN 60 730 18 Nm 50 Nm 90 / 95 ± 2 90 s 15 s AC 24...230 V AC 6 A / 2 A 10 4 cycles 10 6 cycles DC 12..30 V DC 2 A AC 4 kv 2 5 80 2 x 0.75 mm² 2 x 0.75 mm² 6 x 0.75 mm² 0.9 m Housing (actuator only) IP54 to EN 60 529 Operation / transport Humidity (non-condensing) Product safety: automatic electrical controls for household and similar use Electromagnetic compatibility (EMC): Immunity for all models Emissions for all models Conformity to: EMC-directive Low-voltage directive C-Tick Conformity to: Emissions IEC 721-3-3 / IEC 721-3-2 32...+50 C / 32...+50 C < 95 % r.h. / < 95 % r.h. EN 60 730-2-14 (mode of action type 1) IEC/EN 61 000-6-2 IEC/EN 61 000-6-3 2004/108/EEC 2006/95/EEC AS/NZS 61000-6-3 Siemens Air damper actuators GGA126.1E/.., GGA326.1E/.. CE1N4617en 7/10

Dimensions Weight (ready connected to actuator GGA..26.1E/T..) Actuator W x H x D (see "Dimensions") Damper shaft: square min. shaft length Without packaging: GGA126.1E/T... GGA326.1E/T GGA126.1E/.. GGA326.1E/.. Connecting cable (halogen free) Switching temperature for sizing Temperatur tolerance Tf1, Tf2, Tf3 Safety class Degree of protection Ambient temperature / storage temperature Ambient humidity Maintenance Weight 100 x 264 x 71 mm 10x10, 12x12 mm 20 mm 2.4 kg 2.5 kg 2.3 kg 2.4 kg 0.9 m long (2 x 0.5 mm 2 ) Tf1: outside the duct 72 C Tf2: inside the duct 72 C Tf3: inside the duct 72 C 72 C +0 C/ 2 C III (safety extra-low voltage) IP54 20 +50 C / 20 +50 C KL D to DIN 40040 maintenance-free 0.1 kg Diagrams Internal diagrams GGA126.1E/T.. AC 24 V DC 24 48 V (SELV/PELV) GGA326.1E/T.. AC 230 V 8/10 Siemens Actuators for fire and smoke protection dampers GGA126.1E/.., GGA326.1E/.. CE1N4617en

Wire designations All wires are color-coded and labeled. Cable Connection Meaning Code No. Color Abbreviation Actuators G 1 red RD System potential AC 24 V / DC 24 48 V AC 24 V DC 24 48 V G0 2 black BK System neutral Actuators L 3 brown BN Line AC 230 V AC 230 V N 4 blue BU Neutral Auxiliary Q11 S1 grey/red GYRD Switch A input switch Q12 S2 grey/blue GYBU Switch A normally-closed contact Q14 S3 grey/pink GYPK Switch A normally-open contact Q21 S4 black/red BKRD Switch B input Q22 S5 black/blue BKBU Switch B normally-closed contact Q24 S6 black/pink BKPK Switch B normally-open contact Connection diagram GGA126.1E/T.. AC 24 V DC 24 48 V (SELV/PELV) N Controller Y 2-position actuator SP System potential SN System neutral GGA326.1E/T.. AC 230 V N Y L N Controller 2-position actuator Live Neutral conductor Siemens Air damper actuators GGA126.1E/.., GGA326.1E/.. CE1N4617en 9/10

Dimensions Actuator 264 174 67.5 65 36 85 100 71 210 2 6x ø4,4 4x ø5 ø13 150 4x8,5 71 230 4617Z27 20 15,5 LED function Red = Operating voltage OK Thermo sensor defect Green = Operating voltage OK Thermo sensor OK Dark = No operating voltage Dimensions in mm 10/10 2005 2006 2012 2013 Siemens Switzerland Ltd. Subject to alteration Siemens Actuators for fire and smoke protection dampers GGA126.1E/.., GGA326.1E/.. CE1N4617en