TOUGH GARD Anti-Spatter Multi-Feed System

Similar documents
TOUGH GUN AW2 Water-Cooled Automatic 600 amp MIG Guns

TECHNICAL GUIDE. For TOUGH GARD Spatter Cleaner GENERAL SAFETY INSTALLATION MAINTENANCE TECHNICAL DATA ORDERING INFORMATION

TOUGH GUN TT3 Reamer. Nozzle Cleaning Station. Quick Specs. Robotic MIG (GMAW) Welding Peripheral. Rated Input/Output 24 VDC. Weight 50 lbs (23kg)*

Auto-Reamer. 2100E2 Nozzle Cleaning Station. Operating Manual and Parts List. January 2018 v18.1

TOUGH GUN TT3 Reamer For Analog and Tandem Models

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

TECHNICAL GUIDE. T-Gun Semi-Automatic Water-Cooled MIG Guns 450 amp and 600 amp SAFETY & WARRANTY INFORMATION INSTALLATION MAINTENANCE GUIDE

MWR Reamer 08/01/2010

TECHNICAL GUIDE. TOUGH GUN Automatic Air-Cooled MIG Guns 500 amp & 600 amp. TOUGH GUN Automatic Water-Cooled MIG Guns 450 amp & 600 amp

SOLAR DASH CHARGING SYSTEM USER GUIDE

Air Compressor. Owner s Manual

TECHNICAL GUIDE. For TOUGH GUN I.C.E. Robotic Quick-Change MIG Guns SAFETY & WARRANTY INFORMATION INSTALLATION MAINTENANCE GUIDE TECHNICAL DATA

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Features and Benefits Wide Bottom: Translucent Bottle: 2 1/2 Gallon Bottle: Removable Bottle: Large cap: 15 Feet of Coiled Hose:

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

110 Volt/12 Volt Portable Inflator

25 GALLON PORTABLE OIL LIFT

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

Solar Charge Controller Owner s Manual SC 1210 SC 1210LD SC 1220LD

MACHINES / RECLAIMS WITH DUST BAG

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

PUSH BUTTON KEY CABINET

Welding Clips. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

LBT-3 WITH 300 CFM RECLAIM MANUAL NUMBER: 506 TABLE OF CONTENTS

F PRO. 12 Volt Battery Powered Sprayer LIMITED WARRANTY. Part #AS75 Copyright 2014 by Hydro-Force Rev. 1/14

SAVE THESE INSTRUCTIONS

Drum Deheader. Owner s Manual

Owner s Manual & Safety Instructions

Chicane Coilover Kit For '70 to '81 Camaro/Firebird

Specifications. Important Safety Information

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

2000 lb Adjustable Gantry Crane

12 Volt Heavy-Duty Air Inflator

Owner s Manual & Safety Instructions

Pressure Washer Hose Reel

Raydot LLC 24 Actuator (115 VOLT)

Installation Instructions

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

Fifth Wheel Power Hitch Operations Manual

Parts Manual Vermeer/ McLaughlin Mud System 230P

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

'64-72 Chevelle/ A Body Rear Coilover Conversion Kit

Installation Instructions

Please begin by checking that you have received all of the parts that come with your kit.

TECHNICAL GUIDE. TOUGH GUN REAMER TT Series SAFETY & WARRANTY INFORMATION INSTALLATION MAINTENANCE GUIDE TECHNICAL DATA OPTIONS

Dilution Control Systems. 2-Button Station Model OPERATION SERVICE PARTS CARE

Telescoping Pressure Washer Wand 18'

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

Adjustable Shop Stool with Backrest


24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

Parts Manual Vermeer/ McLaughlin Mud System 230P

DRAIN WATER TEMPERING KIT

Color Change Valve. Instructions Parts List K

Operating Instructions & Parts Manual

Poly Strapping Tensioner & Cutter

20250 Module Installation Guide

Dolly with Pneumatic Tires

Owner s Manual & Safety Instructions

MODEL 900 IMPELLER-TYPE FLOW METER

Low Profile Creeper. Owner s Manual

11 GALLON PORTABLE AIR TANK

EF SERIES PUMPS OPERATION & PARTS MANUAL

4400-Lb. Cargo Trolley

DIRECT-DRIVE PRESSURE WASHERS

INSTALLATION INSTRUCTIONS

Models EL-NCS-A-16-D & EL-NCS-AC-16-D ENTERPRISES, INC.

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

# SAVE THESE INSTRUCTIONS

SUBMERSIBLE SUMP PUMPS

Heavy-Duty Welding Fabrication Table

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

Machinery Skate. Owner s Manual

Adjustable Steel Welding Table

1200W Paint DRYING Lamp

Utility Cart. Owner s Manual

Installation Instructions

Power Float Manifold. Installation and Operations Manual Module 11A

'64-72 Chevelle/ A Body Rear Coilover Conversion Kit

INSTALL GUIDE Dodge/RAM 5.7L HEMI

Operating Instructions and Parts Manual AHR-50 Auto Rewind Hose Reel

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

1000-lb Hydraulic Truck Crane

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Universal Bevel Drives Service Manual

SUPERPLUS WATER FILTRATION SYSTEM

2-Pack Indoor/Outdoor Simulated Security Cameras. Owner s Manual

1500-lb Snowmobile Dollies

HEAVY-DUTY STEEL WAGON

Installation Guide and Owner s Manual. For UTCIS-G and UTCIS-V Replacement Warm-up Regulator and Engine Management System

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

Chicane Coilover Kit For '64 to '72 Chevelle/ A Body. Installation Instructions

Instruction Manual For Baldor Buffers

30100 Module Installation Guide L

94-96 Impala SS/ B-Body Rear Coilover Conversion Kit

2-Pack Indoor Simulated Dome Security Cameras

INSTRUCTION MANUAL G-Surge Tank #40007, #40008 & #40009

TECHNICAL GUIDE. For TOUGH GUN Robotic Water-Cooled Quick-Change MIG Guns 450 amp 650 amp SAFETY & WARRANTY INFORMATION INSTALLATION MAINTENANCE GUIDE

Transcription:

OM-MF-1.0 June 2016 Processes MIG (GMAW) Welding Description MIG (GMAW) Welding Peripheral TOUGH GARD Anti-Spatter Multi-Feed System OWNER S MANUAL Tregaskiss 2570 North Talbot Road Windsor, Ontario N0R 1L0 Canada Phone: 1-855-MIGWELD (644-9353) (US & Canada) +1-519-737-3000 (International) Fax: 519-737-1530 For more information, visit us at Tregaskiss.com

Thank You for Choosing Tregaskiss Thank you for selecting a Tregaskiss product. Before installing, compare the equipment received against the invoice to verify that the shipment is complete and undamaged. It is the responsibility of the purchaser to file all claims of damage or loss that may have occurred during transit with the carrier. The owner s manual contains general information, instructions and maintenance to help better maintain your product. Please read, understand and follow all safety precautions. While every precaution has been taken to assure the accuracy of this owner s manual, Tregaskiss assumes no responsibility for errors or omissions. Tregaskiss assumes no liability for damages resulting from the use of information contained herein. The information presented in this owner s manual is accurate to the best of our knowledge at the time of printing. Please reference Tregaskiss.com for updated material. For customer support and special applications, please call the Tregaskiss Customer Service Department at 1-855-MIGWELD (644-9353) (US & Canada) or +1-519-737-3000 (International) or fax 1-519-737-1530. Our trained Customer Service Team is available between 8:00 a.m. and 5:30 p.m. EST, and will answer your product application or repair questions. Tregaskiss manufactures premium robotic MIG (GMAW) welding guns, peripherals and consumables. For more information on other premium Tregaskiss products, contact your local Tregaskiss distributor or visit us on the web at Tregaskiss.com. For additional support materials such as spec sheets, troubleshooting information, how-to guides and videos, animations, online configurators and much more, please visit Tregaskiss.com. Scan this QR Code with your smart phone for immediate access to Tregaskiss.com/TechnicalSupport 2

TABLE OF CONTENTS SECTION 1 - SAFETY PRECAUTIONS - READ BEFORE USING... 4 1-1 Safety Warnings for Installation, Operation and Maintenance...4 1-2 California Proposition 65 Warnings...4 1-3 Commercial Warranty...4 SECTION 2 - SPECIFICATIONS... 5 2-1 System Components...5 SECTION 3 - INSTALLATION / SET UP... 6 3-1 Installing TOUGH GARD Anti-Spatter Multi-Feed System...6 SECTION 5 - MAINTENANCE... 8 SECTION 6 - PARTS LIST... 8 SECTION 7 - TROUBLESHOOTING... 9 Subject to Change The information presented in this manual is accurate to the best of our knowledge at the time of printing. Please visit Tregaskiss.com for the most up-to-date information. 3

SECTION 1- SAFETY PRECAUTIONS - READ BEFORE USING 1-1 Safety Warnings for Installation, Operation and Maintenance READ INSTRUCTIONS Read and follow all labels and the Owner s Manual carefully before installing, operating, or servicing the unit. Read the safety information at the beginning of the manual and each section. Use only genuine replacement parts from the manufacturer. Perform maintenance and service according to the Owner s Manual, industry standards and national, state/ provincial and local codes. SLIP HAZARD Be aware of slip hazard if chemical leaks onto the floor. WEAR CHEMICAL RESISTANT GLOVES Ensure that gloves are resistant to chemicals to prevent skin contact. WEAR SAFETY GLASSES Avoid getting chemical or hazardous material in your eyes. 1-2 California Proposition 65 Warnings Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.) This product contains chemicals, including lead, known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after use. 1-3 Commercial Warranty Seller s Products specified below shall be free from defects in material and workmanship for the period specified below from the delivery to an authorized Buyer provided the Products are operated, maintained, and repaired properly and pursuant to Product documentation provided by the manufacturer. The Warranty against defects does not apply to: (1) consumable components or ordinary wear items; or (2) use of the Products with equipment, components or parts not specified or supplied by Seller or contemplated under the Product documentation. Should there be a defect please refer to our Return Merchandise Policy. Product Tregaskiss TOUGH GUN Robotic MIG Guns and Components Tregaskiss TOUGH GUN Automatic MIG Guns Tregaskiss TOUGH GUN Reamer When factory-equipped with Lubricator When both (i) factory-equipped with Lubricator and (ii) used only with Tregaskiss TOUGH GARD Anti-Spatter Liquid Tregaskiss Robotic Peripherals (Clutch, Sprayer, Wire Cutter, Arms and the TOUGH GARD Anti-Spatter Multi-Feed System) Tregaskiss Low-Stress Robotic Unicables (LSR Unicables) Warranty 1 year 1 year 1 year 2 years when factory equipped with Lubricator 3 years when both (i) and (ii) 1 year 2 years 4

(Commerical Warranty continued) Seller reserves the right to inspect any allegedly defective Product for the alleged deficiencies and that the deficiencies were not caused by accident, misuse, neglect, improper installment, unauthorized alteration or repair, or improper testing. In the event of a defect covered by the above warranty, Seller will, at its option, repair, replace or refund the purchase price of the defective Product. Product found not defective will be returned to Buyer at Buyer s cost after notification by Seller s Customer Service Department. Any TOUGH GUN Reamer component part replaced or repaired pursuant to the warranty herein shall be further warranted for a period of six months after delivery of the replacement. EXCEPT AS SET FORTH ABOVE, SELLER MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PURPOSE. SELLER SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR DAMAGES OF ANY KIND. INCLUDING, BUT NOT LIMITED TO ANY, DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSS OF PRODUCTION OR LOSS OF PROFITS RESULTING FROM ANY CAUSE WHATSOEVER, INCLUDING, BUT NOT LIMITED TO, ANY DELAY, ACT, ERROR OR OMISSION OF SELLER. Genuine Bernard and Tregaskiss parts must be used for safety and performance reasons or the warranty above shall not be valid. Warranty shall not apply if accident, abuse, or misuse damages a product, or if a product is modified in any way except properly and by authorized Seller personnel. SECTION 2 - SPECIFICATIONS 2-1 System Components Female Quick Connect (x3 or x11 depending on configuration) Male Quick Connect (x2 or x10 depending on configuration) 5 Gallon Pail Assembly 55 Gallon Drum Assembly Manifold Each manifold includes 10 sets of the check valve assembly as seen above. One will be fitted to the manifold and the remainder are to be used as necessary when connecting additional Reamer units to either the 5 gallon or 55 gallon assembly. For complete parts list, please see SECTION 6 - PARTS LIST 5

SECTION 3 - INSTALLATION / SET UP 3-1 Installing TOUGH GARD Anti-Spatter Multi-Feed System IMPORTANT: Ideal operating conditions require 80-100 psi at 16 CFM at the Reamer for Sprayer operation. Cap Assembly TOUGH GARD Anti-Spatter Liquid is available in 5 gallon pails and 55 gallon drums. Insert A. To Install Cap Assembly: 1. Remove the plastic cap from the TOUGH GARD Anti-Spatter Liquid pail / drum. (Leave the spout down in the 5 gallon pail.) 2. Insert the cap assembly and tighten securely. NOTE: The cap assembly should pass through the pail / drum opening freely. The cap assembly features a Fluid Level Indicator in order to help monitor levels of TOUGH GARD Anti-Spatter Liquid (see Figure 1). Full Pail Empty Pail NOTE: When the Fluid Level Indicator is no longer visible, there is less than 1 of fluid left. Fluid Level Indicator Figure 1 B. To Connect Hose to Spray Unit NOTE: It is best to start by establishing the pail / drum location. This makes it easier to run hoses and permanently secure them. 1. Remove the reservoir from the Reamer. 2. From the pail / drum, run the hose to the Reamer being sure not to run hoses where they may be damaged or kinked. 3. Once the desired length of hose is set, install the barbed female quick connect fitting in the line (use a very small amount of lube to allow the fitting to insert into the hose easier). 4. Clamps should be used at all connections. 5. Connect the female quick connect on the hose to the male quick connect on the spray unit. Hose Female Quick Connect Male Quick Connect 6

C. To Connect Hose to Pail / Drum with the Y-Connector Connect a hose to Y-connector by using a small amount of lube on the barb and pushing the line onto the barb. Push the line all the way to shoulder of the barbed fitting. Clamps should be used on all connections. Female Quick Connect Y-Connector Cap Assembly Hose to Reamer D. To Connect Hose to Pail / Drum with a Manifold 1. Remove caps from manifold fittings and install the check valve assembly for the desired number of lines. 2. Install the line from the pail / drum to the end of the check valve assembly (as shown on right). Female Quick Connect Cap Assembly Hose to Pail Hose to Reamer Check Valve Assembly Manifold E. Priming the hose Once the hoses have been completely installed, they need to be primed to remove any air bubbles. To Prime Hose Manually Activate the sprayer switch on the TOUGH GUN Reamer until a steady stream of TOUGH GARD Anti-Spatter Liquid is visible from the spray head. To Prime Hose Automatically Activate the sprayer from the robot controller until a steady stream of TOUGH GARD Anti-Spatter Liquid is visible from the spray head. Sprayer Switch TOUGH GUN TT3 Reamer NOTE: Be sure to check for any leaks while priming the hose. Use check valves at all manifold ports to ensure each line keeps its prime. Sprayer Switch TOUGH GUN TT3E Reamer 7

SECTION 5 - MAINTENANCE Under regular operating conditions, there is no need for maintenance. NOTE: Ensure that all hose connections are clamped and tightened as needed to prevent leaks (clamps not included). Clean cap assembly to prevent the TOUGH GARD Anti-Spatter Liquid from clogging. Also check to see that there is a sufficient amount of TOUGH GARD Anti-Spatter Liquid in the pail / drum and replace as needed. SECTION 6 - PARTS LIST TOUGH GARD Anti-Spatter Multi-Feed Cap Assembly Hoses (Sold Separately) TG-103-50 50 Hose (Not shown) TG-103-100 100 Hose (Not shown) TG-103-200 200 Hose (Not shown) ITEM # PART # DESCRIPTION 1 TG-103-2 Cap Assembly (5 Gallon Pail) 2 TG-103-3 Cap Assembly (55 Gallon Drum) 3 TG-103-2-15 Female Quick Connect 4 TS-500-40 Male Quick Connect 5 TG-103-4 Manifold (includes 10 sets of the Check Valve Assembly) TOUGH GARD Anti-Spatter Liquid (Sold Separately) TG-101-01* TG-101-05 TG-101-14S* TG-101-32SP* TG-101-55 1 Gallon (Not shown) 5 Gallon Pail (Not shown) 14 oz (Not shown) 25.36 oz (Not shown) 55 Gallon Drum (Not shown) * Not required for the Multi-Feed System 8

SECTION 7 - TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 1. No spray. 1. Sprayer blocked. 2. Loss of air supply. 3. Faulty solenoid valve. 4. Kink in the multi-feed line. 5. Clogged vent in cap assembly. 6. Loose hose connections. 7. Air bubbles in lines. 8. Unused lines on manifold are not capped. 1. Clean spray head. 2. Check air supply to ensure adequate pressure is supplied. 3. Replace solenoid valve. 4. Check lines and re-run lines to remove and prevent obstructions. 5. Clean cap assembly. 6. Check hose connections and tighten as needed. 7. Re-prime lines. 8. Ensure all unused ports on manifold are plugged with a 1/8 NPT plug. 2. Air flow but no anti-spatter. 1. Loose hose connections. 2. Pail / drum is empty. 3. Spool in solenoid valve block stuck. 4. Fluid line blocked. 5. Faulty check valve. 6. Inadequate air pressure. 7. Clogged filter in cap assembly. 1. Check hose connections and tighten as needed. 2. Refill / replace TOUGH GARD Anti-Spatter Liquid. 3. Replace solenoid valve block assembly. 4. Clean or repair fluid line. 5. Replace check valve. 6. Adjust air pressure to 80-100 psi at 16 CFM (5.5-7.0 bar at 450 LPM). 7. Clean cap assembly. 3. Inconsistent spray flow. 1. Loose hose connections. 2. Damaged hose. 3. Clogged vent in cap assembly. 4. Air bubbles in hose. 1. Check hose connections and tighten as needed. 2. Replace hose. 3. Clean cap assembly. 4. Re-prime hose. 4. Cannot remove air bubbles from lines. 1. Loose hose connections. 2. Priming not completed. 3. Unused ports on manifold are not plugged with 1/8 NPT plug. 1. Check hose connections and tighten as needed. 2. Prime until steady stream is visible from spray head. 3. Ensure all unused ports on the manifold are plugged with a 1/8 NPT plug. 9

For additional support materials such as Spec Sheets, troubleshooting information, how-to guides and videos, animations, online configurators and much more, please visit Tregaskiss.com. Scan the QR Code with your smart phone for immediate access to Tregaskiss.com/TechnicalSupport. Scan to view TOUGH GARD Anti-Spatter Multi-Feed Owner s Manual... Scan to view TOUGH GUN TT3 Reamer Spec Sheet... Scan to view TOUGH GUN TT3 Reamer Owner s Manual... Scan to view TOUGH GUN TT3E Reamer Owner s Manual... Scan to learn about TOUGH GARD Anti-Spatter Liquid... Brand and product names shown above are trademarks of their respective owners. Tregaskiss, TOUGH GUN, TOUGH GARD are trademarks of Tregaskiss, a division of ITW Canada Inc. Tregaskiss 2570 North Talbot Road Windsor, Ontario N0R 1L0 Canada Phone: 1-855-MIGWELD (644-9353) (US & Canada) +1-519-737-3000 (International) Fax: 519-737-1530 For more information, visit us at Tregaskiss.com