Installation, Operation & Maintenance Instructions for MF Series Solution Feeders

Similar documents
Installation, Operation & Maintenance Instructions for MF-Solar Series Solution Feeders

Axiom Industries Ltd Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) Fax: (306)

Model &

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Rev: Flow Max 115V AC Fluid Pump

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

Troubleshooting WARNING

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Secondary Coolant 301

BMF TROUBLESHOOTING GUIDE

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

PowerFLO 5800/5900 Series

INSTALLATION INSTRUCTIONS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Operating Instructions & Parts Manual

END SUCTION CENTRIFUGAL PUMPS

Iron Gate Air Pump System Manual

WORKHORSE. Assembly / Operation Instructions / Parts

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

DESIGNED BY EXPERIENCE PLASTIC SPHERE DISPENSER USER MANUAL. Manufactured by PSDS, Inc. for sole distribution by:

WORKHORSE. Assembly / Operation Instructions / Parts 15 & 25 GALLON SPOT SPRAYER

Manifold Isolation Valves

SHURFLO AQUA KING II STANDARD 3.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

Flojet Rewrites the Book on Small Pump Control

Trouble Shooting Guide EWA, 3-phase (D2422)

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

SERVICING INSTRUCTIONS

Pulsation Dampeners NEW! Wanner Engineering Inc

WORKHORSE. Assembly / Operation Instructions / Parts DELUXE ATV BOOMLESS SPRAYER

Priming Systems Installation Instructions

Cleaning Systems Inc. 2 P Rev:03

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Installation & Operating Manual

SERVICE MANUAL 200 SERIES MOTORIZED 20352, 20452, 20551, 20552, AND MODELS

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Operating and Installation Instructions

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Low Profile J Series Power Unit with Vane Pump

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

HALLMARK INDUSTRIES INC

Electric Fuel Pump FPM

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Composite PEX-AL-PEX Tubing

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

Installation & Technical Guide. Domestic & Commercial.

PRE-PLUMBED SEWAGE SYSTEM

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

¼ to 1HP Chiller Service Manual

Hydro-Sync Slide-Out System

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

30 GALLON TRAILER SPRAYER ASSEMBLY & OPERATION INSTRUCTIONS MANUAL TSC SKU#: VENDOR#: TS30G-CL

PLUNGER PUMP SERVICE MANUAL

PLUNGER PUMP SERVICE MANUAL

WEBER CARBURETOR TROUBLESHOOTING GUIDE

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

INDUSTRIAL PUMP 8000 SERIES

PACIFIC Recumbent Height-Adjustable Bath System Parts Breakdown and Assembly Manual

IN-LINE HYDRAULIC FLOW TESTER

OPERATION AND PARTS MANUAL

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

LAWN SPRINKLER, IRRIGATION PUMP

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

M-3025CB-AV Fuel Pump

WORKHORSE. Assembly / Operation Instructions / Parts

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

WALKIE HIGH LIFT HYDRAULIC SYSTEM

Manual for all Rittenhouse Skid Mount & Trailer Sprayers

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

SS/SSH Submersible Pump. Owner s Manual

Operation & Service Manual

SHALLOW WELL JET PUMP

ESE Series Cast Iron Sewage Pumps

WORKHORSE. Assembly / Operation Instructions / Parts

New Fan Coil Piping Packages

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION

Installation & Operator s Manual

Troubleshooting 3Z8 038 Rev B

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

DIGITAL GLYCOL FEEDER

OCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET

SERIES PC INSTRUCTION AND OPERATION MANUAL

1" QickZone Modular Brass Manifold Installation Instructions Parts List

PIPING PACKAGES For Chilled and Hot Water Fan Coil Units

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Transcription:

INDUSTRIES LIMITED Installation, Operation & Maintenance Instructions for MF Series Solution Feeders Startup Procedure ) Close isolation valve between feeder and system connection point 2) Fill reservoir, turn valve on feeder to mix/purge and plug in 3) Ensure pump is cycling fluid through reservoir (primed) 4) Turn valve to run and open isolation valve to system 26 Wentz Avenue, Saskatoon, SK S7K J Ph: (306) 6-8 Fax: (306) 6-2293 email: sales@axiomind.com website: www.axiomind.com

MF200 and MF300 HYDRONIC SYSTEM FEEDER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS The System Feeder is used to maintain a minimum system pressure within a hydronic heating or cooling system. It should be used to pressurize the system while system temperature is at it s lowest. Installation Instructions. Set System Feeder on a secure and level base or in the optional tank shelf. 2. Connect the unit to the system using copper or plastic tubing. Ensure that there is a system isolation valve installed to allow for isolation of the unit. DO NOT INSTALL A CHECK VALVE OR PRESSURE REGULATOR BETWEEN SYSTEM FEEDER AND SYSTEM. 3. Mount power supply and secure with mounting bracket. Do not power up System Feeder until a system connection is made, isolation valve is closed and Feeder valve is set to mix. 4. To connect the system feeder to the RIA0--SAA alarm panel remove low level float switch from circuit and connect to axiom RIA0--SAA alarm panel.. Install proper water/glycol mix in the tank to a level above minimum level indication on tank scale. A 30-0% Polypropylene Glycol is Recommended. 6. Close system isolation valve, turn feeder valve to vertical position (mix position). 7. Insert DC plug into the System Feeder first, and then plug power supply into 20v outlet. The red LED in the power supply cord should light up. If it does not, check the fuse and power receptacle. 8. Once the pump is primed, turn the feeder valve handle to horizontal position (run position), open system isolation valve and allow pump to pressurize system. If system pressure is below pressure switch setting (8 psi), the pump will start. The System Feeder will run until system is pressurized to approximately 8 psi. and shut-off. It may cycle rapidly a number of times while system pressure stabilizes and while air is removed from the system. The cycling will stop once system pressure rises above 8 psi due to thermal expansion. 9. If a higher fill pressure is required (up to 2 psi) the internal pressure switch may be adjusted by turning the center adjusting screw counter clockwise to increase pressure. Access to the pressure switch can be gained by lifting the left side of the top cover. 0. The MF200 is shipped with a small amount of 0% propylene glycol (non-toxic) in the discharge tubing between the pump and the check valve. This is to aid in priming. Please note that the pressure gauge supplied with the unit may read differently from another gauge, which may be installed elsewhere in the system. This may be due to gauge calibration or differences in elevation within the system and should not be a concern. The System Feeder does not require any scheduled maintenance. Should you wish to test pump operation, turn mix/purge valve to vertical position to start pump. Turning mix/purge valve handle to horizontal position will stop pump.

COLD STATIC FILL PRESSURE The cold static fill pressure (CSFP) in a closed hydronic system has to be high enough to accomplish three things. ) Overcome the static head (height) between the fill point and the highest point in the system. 2) Provide adequate pressure (minimum 4 psig) at the top of the system for proper air venting. 3) Maintain adequate pressure at the inlet of the system pumps to prevent cavitation. The formula for calculating the required CSFP to satisfy points & 2 is: (Static height in feet/2.3) + 4 = CSFP in psig. As an example, the CSFP for a system with a static height above the fill point of 40 feet would be: (40/2.3) + 4 = 2.3 psig. For most closed hydronic systems operating below about 20 F, maintaining the minimum topof-system pressure at 4 psig will be adequate to prevent pump cavitation even if the pumps are at or near the top of the system as well. IMPORTANT NOTE For air-charged diaphragm or bladder tanks, the air charge in the tank must be adjusted to equal the cold static fill pressure before it is connected to the system.

Purger Pump Expansion Tank MF 200 Connection Schematic MF 200 Packaged System Feeder

Installation Instructions for the RIA0--SAA Control Panel for use with MF200 Feeder The low level float switch in the MF series are factory wired to be OPEN on LOW LEVEL. Remove the screws fastening the top cover to the unit and lift the cover to get access to the float switch wiring. Disconnect the power before doing this.. Cut the wires connecting the float switch to the rest of the MF200 circuit. 2. Connect the wires to complete the circuit without the float switch. Note the switch positions shown in this document are for the unit as it comes out of the box, with no fluid in the tank and no pressure in the system

3. Extend the wires from the float switch and push the float cable through strain relief fitting in control panel and connect float wires to terminals and 2 on terminal strip. Connect ground wire to ground connection. Tighten strain relief nut to secure cable into panel. 4. Connect DCS wiring to remote alarm dry contacts as requested to provide alarm signal.. To disable the audible alarm, remove the jumper on the control board. 6. Plug the MF200 into the RIA0--SAA panel. Interrupteur à flotteur 2 Retirez le cavalier pour désactiver l alarme sonore Note : l isolation du câblage à basse tension doit être approuvée pour 300V 3 4 N.F. N.O. COM

INDUSTRIES LIMITED LEGEND ITEM # PART # DESCRIPTION 26 MF200-00 20V to 24DCV power adapter 23 2 2 3 MF200-0 inline DC jack (female) MF200-020 adjustable pressure switch 9 4 MF200-030 alarm hook up terminal strip MF200-0400 pressure snubber 3 8 8 3 4 3 20 2 2 9 6 7 8 9 0 2 MF200-0700 pressure gauge MF200-0800 float switch MF200-0900 brass reducer MF200-0920 strainer MF200-0930 3/8" plastic hose MF200-090 ½ OD clear braided hose MF200-0960 3/8 vinyl hose 6 4 3 4 MF200-0970 /8" plastic clamp MF200-0980 ¼ check valve 0 2 24 22 6 7 MF200-0990 /2" to /4" adapter MF200-000 tank MF200-000A tank cap 7 8 9 MF200-200 ¼ angle ball valve MF200-300 pump & motor assembly 7 20 MF200-400 manifold block 2 MF200-40 bracket - manifold block 6 22 MF200-420 power adapter bracket 23 MF200-00 strain relief grommet 24 2 26 MF200-0 cable clamp MF200-20 ½ plastc clamp MF200-600 tank lid PROJECT CUSTOMER MF-200 (EXPLODE) AXIOM INDUSTRIES DRWG. NO. EQUIP. NO. JOB NO. DATE TLL-MF200-00 PARTS LIST AUG 26 204 26 Wentz Avenue, Saskatoon, SK S7K J Ph: (306) 6-8 Fax: (306) 6-2293 email: sales@axiomind.com website: www.axiomind.com

LEGEND ITEM # PART # DESCRIPTION 26 MF200-00 20V to 24DCV power adapter 23 2 2 3 MF200-0 inline DC jack (female) MF200-020 adjustable pressure switch 9 4 MF200-030 alarm hook up terminal strip MF200-0400 pressure snubber 3 8 8 3 4 3 20 2 2 9 6 7 8 9 0 2 MF200-0700 pressure gauge MF200-080 float switch MF200-0900 brass reducer MF200-0920 strainer MF200-0930 3/8" plastic hose MF200-090 ½ OD clear braided hose MF200-0960 3/8 vinyl hose 6 4 3 4 MF200-0970 /8" plastic clamp MF200-0980 ¼ check valve 0 2 24 22 6 7 MF200-0990 /2" to /4" adapter MF200-000A tank cap MF300-00 tank 7 8 9 MF200-200 ¼ angle ball valve MF200-300 pump & motor assembly 6 20 MF200-400 manifold block 2 MF200-40 bracket - manifold block 7 22 MF200-420 power adapter bracket 23 MF200-00 strain relief grommet 24 2 26 MF200-0 cable clamp MF200-20 ½ plastc clamp MF300-600 tank lid PROJECT CUSTOMER MF-300 (EXPLODE) AXIOM INDUSTRIES DRWG. NO. EQUIP. NO. JOB NO. DATE TLL-MF200-00 PARTS LIST 26 AUGUST 204

Adjusting the Pressure setting on the MF200 The high limit pressure switch is integral to the pump and will open if the pressure reaches approx. 27 psig. NOTE this switch is only found in units with the new style pump, serial number 03-2 and higher. The pressure switch is factory set to shut off the pump at about 8 psig. It can be field adjusted to a maximum of 2 psig. Adjustable pressure set screw

Troubleshooting Chart Symptom Possible Cause Resolution Pump will not start Fluid level in tank is low Add correct fluid. Check for cause of system fluid loss Blown fuse Check LED indicator light on power cord, check fuse and replace if needed (2. Amps) Power supply or Breaker Check LED indicator light on power cord, flip breaker or obtain power supply from reseller and replace Power supply unplugged or loose electrical connections Plug in power supply or correct faulty electrical connection Pressure switch out of adjustment Faulty pressure switch Pump failure Adjust pressure switch according to the manufacturers recommendations First obtain snubber from reseller and replace. If problem continues obtain pressure switch from reseller then replace Obtain pump from reseller and replace Pump will not shut off Air lock in pump Turn purge/mixing valve to prime pump Leak in system or pump Inspect system and repair leak Faulty pressure switch Obtain pressure switch and snubber from reseller then replace Pump will not prime Check valve stuck Tap check valve lightly Fluid level in tank is low Add correct fluid. Check for cause of system fluid loss Strainer on inlet hose is blocked Clean strainer Product in tank is too thick or Congealed glycol Inlet tubing leak is drawing air Inlet/Outlet tube severely restricted (Kinked) Clean strainer and check concentration of glycol mixture Replace tubing and repair leak Replace tubing

Noisy / Rough operation Pump is overloaded and pump pressure switch not cutting out Loose pump head or drive screws Feeder is plumbed with rigid pipe causing noise to transmit Obtain Replacement pump from reseller and install Tighten screws Plumb with PEX or plastic pipe Feeder Leaking Manifold block over tightened and cracked Loose fittings Pump has punctured diaphragm Obtain replacement manifold block from reseller and install Tighten fittings Obtain Replacement pump from reseller and install System pressure low Fluid level in tank is low Add correct fluid. Check for cause of system fluid loss Blown fuse Check LED indicator light on power cord, check fuse and replace if needed Power supply or Breaker Check LED indicator light on power cord, flip breaker or obtain power supply from reseller and replace Pressure switch out of adjustment Adjust pressure switch according to the manufacturers recommendations Snubber on pressure switch is plugged Obtain snubber from reseller and replace Faulty pressure switch Obtain pressure switch and snubber from reseller then replace Power supply unplugged or loose Plug in power supply or correct faulty electrical connections electrical connection Pump failure Obtain pump from reseller and install System pressure to high Pressure switch not adjusted to proper Adjust pressure switch, refer to setpoint maintenance manual for instructions Snubber on pressure switch is plugged Obtain snubber from reseller and replace. Ensure fluid in tank is clean. Faulty pressure switch Obtain pressure switch and snubber from reseller then replace Pump Cycles Continually Air is being removed from system and No action required pump is only making up fluid Leak in system Inspect system and repair leak Check valve or Regulator installed Remove check valve or regulator between System Feeder and system