The ECLIPSE #9800 & The ECLIPSE #9800WC

Similar documents
June 25, 2013 # Model 464 Electronic Pump Control Unit User Guide

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

i n s t r u c t i o n m a n u a l

January 10, 2017 # Rev. B. Model 464 Mk3 Electronic Pump Control Unit User Guide

DIG Corporation Irrigation product Specifications

710-xxxp Propagation & Irrigation Battery Operated Controller

i n s t r u c t i o n m a n u a l

i n s t r u c t i o n m a n u a l

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

i n s t r u c t i o n m a n u a l

Single, Four & Six Station Battery Operated Controllers 710-XXX ASV PRF-ASV-XXX

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

Optima ETF-600/ETF-610

INSTRUCTION MANUAL. Model 7001 Battery Operated Irrigation Controller with Hose or Pipe Thread

POOL PILOT SOFT TOUCH OPERATING, TROUBLESHOOTING AND TECHNICAL CHEAT SHEET

7500 Greensand Filter Installation & Start Up Guide

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

i n s t r u c t i o n m a n u a l

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

PRO series programmer

fusion RF Control Handle

i n s t r u c t i o n m a n u a l

UltraDose From Lyn Distributing

Installation and User s Guide

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

OPERATOR S MANUAL X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

Automatic Sensor Faucet Installation Manual CAT ALL-IN-ONE AUTO VALVE FAUCET HORIZONTAL WATER SPOUT. Revision

Model 800 Disassembly Instructions and Troubleshooting

ELECTRONIC FLUSH VALVE FOR URINALS jupiter 2040

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Locks LOCKING AND UNLOCKING. Automatic unlocking. Interior door handles and door locking levers. Master lock and unlock switches. Drive-away locking

FPS- 80. Manual. Reverso Pumps, Inc. Ph: (954)

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

KIT CONTENTS Qty Part Description Part Number

Patent Pending EXTENDED-DUTY PISTON PUMP

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

EZ SDI-1 TM. Installation and Operating Manual. Distributed By:

PORTAGAUGE 4 USER MANUAL

Heating and ventilation

5900e Carbon Filter Installation & Start-Up Guide

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Breezair TBA 550 Installation Manual

AUTOMATIC SPRINKLER TIMER

Battery Operated Advanced Computerized Irrigation Controller Installation and Operating Instructions

TC Series Cooling Systems

Model 1100B CHG Terminator. Installation Instructions

Installation & Set Up Guide

AutoDose Automatic Dispensing System

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

DIAGNOSTIC FLOW CHART FOR V-68 ELECTRO LIFT UNIT

Oper pe ati t ng i Presented by:

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Robotic Cleaner Troubleshooting Guide. Copyright 2010 Hayward Industries Inc.

Two, Four and Six Station Battery Operated Controllers 720A-XXX 740A-XXX 760A-XXX

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

NUMBER: rev S.M. REF.: Refer to 2.47 ENGINE: 50 DATE: June 2001

Subject Underhood G System Error Codes and Symptoms System or Parts affected

In addition to this instruction sheet, the following are included in this kit (some additional parts are included for future maintenance):

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

Service Manual Air Tech Second Stage

TBI /2012 TRAUMATIC BRAIN INJURY DEVICE

Wireless Tire Pressure and Temperature Monitoring System Instruction Manual Model #: TM Cap Sensors

Cannondale Diagnostic Tool Manual

WirelessAIR Advanced Integrated Remote

SOLUTION STATION Instruction Manual

MAINTENANCE MANUAL DI 16

Operation and Maintenance Instructions

Battery Operated Advanced Computerized Irrigation Controller Installation and Operating Instructions

Light switch timer 3 step Installation overview 3 minute quick programming guide. A police accredited product.

Baxter 6201 and 6301 Tips to Avoid Nuisance Alarms Call x 335 for troubleshooting assistance.

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

Hydraulic Oil Cooler. Assembly Instructions (Originating w/serial Number )

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

RS-110 Rainfall Sensor Installation Guide

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

E-Coder)R900i Quick Install Guide. E-CODER)R900i QUICK INSTALL GUIDE

Planting. Press to Highlight Configuration. Gauge Wheel Load Alarm. Value must be entered for your specific planter and parallel arm combination

Priming Systems Installation Instructions

REC-11+ REMOTE RECEIVER UNIT

3 Spin Klin Battery Operation and Maintenance Manual

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

High Pressure Leak Diagnostics System Part No & NA USER MANUAL LEAK DETECTION SERVICE

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

DESIGNED BY EXPERIENCE PLASTIC SPHERE DISPENSER USER MANUAL. Manufactured by PSDS, Inc. for sole distribution by:

B-RAD Select USER MANUAL TABLE OF CONTENTS

INSTALLATION AND CUSTOMER CARE INFORMATION 80 SERIES & 90 SERIES TREATMENT STATIONS

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

MLP2 - DUAL-BRANCH LUBRICATION SYSTEM

PowerFlo Parts List/Assembly Instructions/Users Guide ***PLEASE READ ALL INSTRUCTIONS CAREFULLY AND THOROUGHLY***

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

MT-1 Tracer Meter. RENOGY MT-1 Tracer Meter for Duo Battery Charge Controller E. Philadelphia St., Ontario CA

The BMW i3 The Ultimate Driving Machine

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

AquaMatic Series. A100 and A200 Stager Controls

Mini Multimeter with Non-Contact Voltage Detector (NCV)

model 2000SN FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS Recessed Wall-Mount Bottle Filling Station

3406E Truck Engine 5EK01821-UP(SEBP ) - Document Structure. Media Number -RENR Publication Date -01/02/2008 Date Updated -07/02/2008

Iron Gate Air Pump System Manual

Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

RAIN BIRD - AQUAGATOR AQUAGATOR INSTALLATION & TROUBLESHOOTING MANUAL

Transcription:

Operating and Maintenance Manual Installation of The ECLIPSE #9800 & The ECLIPSE #9800WC The John C. Kupferle Foundry Company 2511 North 9 th Street St. Louis, Missouri 63102, USA Tel: 1-800-231-3990 Tel: 314-231-8738 Fax: 314-231-2820 Disclaimer: While this document is complete, comprehensive, and accurate to the best of Kupferle s knowledge, this document is subject to change and is for general information purposes only. 1

Index Cover Page.. 1 Index 2 Description.. 3 Installation... 5 Operation. 6 Programming the Controller 7 Maintenance 9 Parts Replacement... 10 Appendix #9800... 11 Appendix #9800WC.. 12 2

Description 1. The hydrant is a permanently installed flushing device intended to maintain high water quality by purging the older water from main water lines. 1.1. Cold Climate Equipment Number #9800 1.2. Warm Climate Equipment Number #9800WC 2. General Description 2.1. The 9800 automatic flushing hydrant has a 2 brass F.I.P. inlet which leads vertically into a 2 automatic flushing valve. The valve controls the flow of water through the hydrant and its diaphragm with the extension and retraction of a DC latching solenoid. All operating parts of the unit can be serviced or replaced without digging up or disturbing the supply line connection. The hydrant can be easily maintained or serviced above ground after the stainless steel access plate is removed, via removal from the water line, via an O-ring connector located under the valve. The valve has a 150 psi rating and is physically located below grade to protect against freezing. The entire unit is contained in a UV-Resistant enclosure with a removable locking cover. NOTE: Refer to Appendix page 11 for a typical cut sheet. 2.2. The 9800WC automatic flushing hydrant has a 2 brass M.I.P. inlet which leads vertically to the bottom of a 2 automatic flushing valve. The valve controls the flow of water through the hydrant and its diaphragm with the extension and retraction of a DC latching solenoid. All operating parts of the unit can be serviced or replaced without digging up or disturbing the supply line connection. The valve has a 150 psi rating and is physically located above grade inside of the enclosure allowing for easy service, and if desired removal via a quick disconnect. The entire unit is contained in a UV-Resistant enclosure with a removable locking cover. NOTE: Refer to Appendix page 12 for a typical cut sheet. 3. The digital controller has nine possible flushing intervals per day. The length of a flush can be set for any amount of time ranging from 1 minute up to 4 hours. Refer to the Programming the Controller section (Pages 7-8) for how to set the controller parameters. The controller uses a standard 9-volt battery to pulse the solenoid valve and operate the controller. It is recommended that the battery be replaced every 500 flushes or once a year. Use the Battery Status icon on the controller screen to gauge the remaining life of the battery. An index of symbols encountered on the controller screen can be found on the reverse side of the controller. 3

4. Key Description Left Arrow Key Plus Key Menu Key Minus Key Right Arrow Key 5. Description Manual Watering/Flushing Current Time/Day Watering Days Sensor Interrupted Start Time Run Time System Off Battery Status Watering /Flushing 4

Installation 1. The supply lines must be flushed free of any rock, gravel, or other debris before connecting the hydrant or installing any new or replacement parts. 9800 9800WC Insert installed 9800WC photo here. 5

1) General Description Operation When the time of day reaches a programmed time the controller will retract the solenoid valve, allowing water to travel through the 2 automatic flushing valve. After the programmed length of time has elapsed the controller will extend the solenoid valve, causing the diaphragm to close via the water pressure. Water exits the unit through direct discharge and discharges to a separate drain system. 2) Performing a Manual Blow-Off / Test The hydrant allows the user to perform manual blow-offs, a.k.a. manual tests, by temporarily overriding the timing functionality of the controller. a) Push the menu key until the current time is displayed on the Main Menu. NOTE: The Main menu also shows the battery life remaining. b) Press and hold the right arrow key. The Manual Flushing icon will appear in the lower left of the screen. c) Use the plus or minus keys to adjust the flushing time between 1 minute and 4 hours. d) Once the keys are released, the controller will begin a 10 second countdown to start flushing. The Flushing icon will flash on the right side of the screen when flushing is in progress. Time of Day Battery Life Indication Length of Flush Manual Flushing icon Countdown Flushing icon e) To stop manual flushing, press the menu key until the System Off icon flashes on the left side of screen. After 4 seconds, OFF will appear on the display and the device will stop flushing. System Off icon NOTE: Leaving the controller to rest on the OFF screen shown above will put the controller in sleep/off mode preventing the controller from performing any programmed flushes. To continue with the scheduled flushing, press the menu key until the Main Menu is displayed, as seen to the right. Resting at this menu will allow the controller to perform the programmed flushing schedule. 6

3) Manual Sampling The unit also has a double-valve, all brass sampling point. Programming the Controller Setting the Date and Time 1. Press the menu key until the Current Time/Day icon appears in the top left corner of the screen. The display will show the hour, the minute, the time notation, and the day of the week. The day of the week is the number at the bottom of the screen. (1=Sun, 2=Mon, 3=Tues, etc) 2. Use the arrow keys to select the value to modify. Use the plus or minus keys to modify the selected value. Choices for time notation are AM, PM, and 24 hour. Kupferle recommends using the AM and PM time sets. 3. Navigating away from this screen will set the Current Time/Day. Setting Flushing Times 1. Press the menu key until the Start Times icon appears on the left side of the screen. The display will show the hour, the minute, and the Flush Time Number. The Flush Time Number is displayed to the left of the hour. 2. Use the arrow keys to select the Flush Time Number in which it is desired to modify the time. Use the plus/minus keys to change the time at which the unit will begin flushing. The start time will increase/decrease in 5 minute intervals. 3. To disable a Flush Time, select the desired Flush Time Number and set its time to OFF. OFF is found between 11:55 PM and 12:00 AM. When all Flush Times are set to OFF, then the unit s automatic flushing is off. 4. Navigating away from this screen will set the flush times. Setting the Run Time (Length of Flushing) 1. Press the menu key until the Run Time icon appears in the bottom left corner of the screen. 2. Use the plus or minus keys to set the Run Time. Run Time can be scheduled from 1 minute up to 4 hours. 3. Navigating away from this screen will set the Run Time. Setting the Days to Flush 1. Press the menu key until the Watering Days icon appears in the upper left of the screen. The screen will display the days of the week at the bottom of the screen and indicate which days are set to be watered on and which days will not be watered. (1=Sun, 2=Mon, No Flushing Time Notation Time Notation Day of the Week Flush Time Number Flushing Enabled Days of the Week 7

3=Tues, etc) 2. Use the arrow keys to select the desired day of the week. Use the plus or minus keys to activate or deactivate the flushing for the selected day. Once plus or minus is pushed, the cursor will advance to the next day. Selecting Interval Flushing 1. Press the menu key until the Watering Days icon in the upper left of the screen. The screen will display the days of the week at the bottom of the screen and indicate which days are set to be watered on and which days will not be watered. 2. Press the left arrow once when day 1 is selected, or press the right arrow once when day 7 is selected. The Interval Watering icon will appear on the display. 3. Press the plus or minus key to set the number of days between flushes. The flushing device will flush at the next Start Time and then again at the interval selected. NOTE: Kupferle does not recommend using the interval flushing option. Watering Interval Interval Watering 8

Maintenance NOTE: The water supply must be turned off before maintenance can be performed, typically via the valve box leading to the hydrant. Removing the 2 Valve Cold Climate: 1. Remove lid from unit. 2. Move clasps to remove small plate. 3. Unbolt the two bolts to remove large access plate. Removal is accomplished by actually lifting the hydrant from the base. 4. Remove the pipe from the hydrant. All operating parts will then come up with the male o-ring connector plug. Warm Climate: 1. Remove lid from unit. 2. Unscrew the solenoid to relieve pressure from the valve. 3. Use the quick disconnect to separate the valve from the rest of the hydrant. All operating parts will then come up with the female disconnect. Troubleshooting the Controller 1. Turn off the Main Water Supply. 2. Unthread the solenoid from the valve to remove the controller from the unit. 3. Run a manual blow-off or test as described previously in #2 of the Operation section on Page 6. 4. If the solenoid audibly clicks and visibly retracts and if the controller is performing correctly, then the controller and solenoid are both in good working condition. The valve and diaphragm need to be checked for debris and/or damage; see below. NOTE: Please make sure that the solenoid is firmly threaded into the valve. Overthreading or underthreading the solenoid may cause water flow issues. Cleaning and Inspecting the Valve and Diaphragm 1. Turn off the main water supply to the hydrant, if not already done so. Remove the 12 bolts from the valve. 2. Retrieve the diaphragm from within the unit. Do NOT remove the small spring from the bottom of the diaphragm. 9

3. Remove any and all debris from inside the valve. If desired, clean each piece with running water to remove smaller debris on the diaphragm or inside the unit. Inspect the diaphragm for any damage. 4. Inspect the plastic casing of the valve. Hang nails may be gently filed down. 5. Reassemble the valve and replace it on the unit. Turn the main water supply on. Test the unit. Replacing the Battery Parts Replacement 1. Hold one side of the controller in each hand. Twist the controller to open the battery compartment. 2. Insert a new 9 volt alkaline battery into the battery holder. 3. Ensure that the battery compartment is free from water. Thread the controller back together to create a good seal. NOTE: It is recommended that the battery be replaced every 500 flushes or once a year. Use the Battery Status icon on the controller screen to gauge the remaining life of the battery. Ordering Replacement Parts Replacement parts may be ordered from any water works distributor. A list of distributors may be obtained by calling Kupferle Foundry Co. at 800-231-3990 or by visiting Kupferle s website. www.hydrants.com/component/part-maintenance.html Parts lists are also available on Kupferle s website. 10

Appendix 11

12