ISO 5011 Test Results

Similar documents
ISO 5011 Test Results

ISO 5011 Test Results

ISO 5011 Test Results

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

ISO 5011 Test Results

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

ISO 5011 Test Results

ISO 5011 Test Results

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

ISO 5011 Test Results

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

ISO 5011 Tested to Make Sure You Maximize Airflow While Still Protecting Your Engine.

ISO 5011 Tested to Make Sure You Maximize Airflow While Still Protecting Your Engine.

Direct Flow Air Cleaners DF600 Series

UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE STANDARD FOR SPARK ARRESTERS FOR INTERNAL COMBUSTION ENGINES

Turbocharger Compressor Calculations

# D: Information on Higher Than Expected Oil Consumption - (Nov 16, 2016)

Retrofit Crankcase Ventilation for Diesel Engines

PowerCore Air Cleaners Two-Stage

Fuel Transfer Pump. OEM Part Numbers: , EP L. Fuel Transfer Pump. OEM Part Numbers: , EP

MnI Diesel, LLC MnI Maintenance, LLC. Setting the Standard in Oil Filtration Keep It Clean! & Keep It Green!

Table of Contents. 4. Before a New Turbocharger is Installed

2013 Northeast Diesel Collaborative Partners Meeting

Modern Automotive Technology Chapter 16. Engine Size and Performance Measurements

10/24/2017 # B: New Tool Availability - EN EGR Cooler Pressure Tester Adapter Set to Diagnose Duramax Diesel Engine EGR Coole

2. provide data indicating what types and sizes of particles are not removed by used PHEAF devices, and

The Next Generation of Intakes. advanced FLOW engineering. Instruction Manual P/N: /

EN EGR Cooler Pressure Tester Adapter Set

See Note. 100% of rated load 2,4,6, (17.73)

Cylinder Head Comparison Sheet Big Block Mopar

Setting the Standard in Oil Filtration Keep It Clean! & Keep It Green!

PowerPleat Air Cleaners

RFI COLD AIR INTAKE INSTALLATION MANUAL. GM Duramax 6.6L LMM Stage 2 RFI

OIL BATH INTAKE AIR FILTERS. Capacities up to 6500 CFM

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

Innovative Filtration Solutions

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

Focus On Training Section: Unit 4

Direct Injection Ethanol Boosted Gasoline Engines: Biofuel Leveraging For Cost Effective Reduction of Oil Dependence and CO 2 Emissions

Catalog & SalesManual

2.61 Internal Combustion Engines

2.25 H .75 D 3.5 W. (actual size)

EMI / RFI Shielding Products. Shielding Honeycomb Ventilation Panels and Dust Filtration Characteristics

Generator set data sheet 1000 kw continuous. Fuel type: Natural gas MI 62 +

See Note. 100% of rated load. Mechanical efficiency ISO3046/1 2,4,7 35.2% 34.8% 34.1% Electrical efficiency ISO3046/1 2,4,6,7 33.7% 33.4% 32.

See Note. 100% of rated load

Using Multiple Cylinder Engines

FRG Air Cleaners. Superior Protection for Larger Engines RadialSeal Sealing Technology Means Reliable Filtration and Quicker Service

KTA50 Land Based Drilling Power Modules

MISHIMOTO ENGINEERING REPORT

See Note. 100% of rated load

See Note. 100% of rated load

FPG & FPG Alexin Air Cleaners

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

See Note. 100% of rated load

PowerPleat Air Cleaners

See Note. 100% of rated load

advanced FLOW engineering Stage-2 Air Intake Instruction Manual P/N: &

RFI COLD AIR INTAKE INSTALLATION MANUAL GM 6.6L Duramax LBZ Not legal for sale or use in California on pollution-controlled vehicles.

MITSUBISHI DIESEL ENGINE IFM NO. JN (1/6) TECHNICAL INFORMATION DATE Aug. 8, 2002

Engine Cycles. T Alrayyes

Document ID:

Effectiveness of Cabs for Dust and Silica Control on Mobile Mining Equipment

@Perkins. Technical Data Series 2806C-E18TAG1A. Diesel Engine - ElectropaK. Basic technical data. Cyclic irregularity. Ratings.

@Perkins. Technical Data Series 2806A-E18TAG1A. Basic technical data. Cyclic irregularity for engine/flywheel maximum: Ratings.

Internal Combustion Engine

Daytona Prototype - Chevy Race Engine Ford GT Supercharger Coolant System Performance & Protection Presentation

Managing Particle Contamination with Chevron ISOCLEAN Certified Lubricants

DFIT Diagnostics Reference Guide

APP S 674 pumps APP S / APP S APP S

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS

FOR AIR CONDITIONING AND VENTILATING APPLCATIONS

PowerCore Air Cleaners Two-Stage: PSD and Single-Stage: PCD

Unit C: Agricultural Power Systems. Lesson 6: Using Multiple Cylinder Engines

Inlet House Air Filters Presented By: Zahi Youwakim

PAHT pumps / PAHT G pumps / ATEX PAHT G pump

Service Access Cover. Vacuator Valve. Accessories

1104D-44T Industrial Diesel Engine

The Next Generation of Intakes advanced FLOW engineering. Instruction Manual P/N: /

CAGI Data Sheets. Blower Performance Comparison. Stephen Horne, Blowers Product Manager Kaeser Compressors, Inc.

Document ID: This PI was superseded to change labor operation time from.4 to.5. Please discard PIP4307G.

Document ID: GM has adopted a policy that prevents any UNAUTHORIZED dealer warranty claim submissions to any remaining warranty coverage.

Cummins Techical Operations

Generator set data sheet Prime. Fuel consumption. Engine Standby rating Prime rating Continuous rating. Fuel flow

SUPERCHARGER AND TURBOCHARGER

Cummins and Fleetguard are registered trademarks of Cummins, Inc. Mann+Hummel is a registered trademark of Mann+Hummel GMBH

CUMMINS ENGINE COMPANY, INC. Engine Data Sheet

GEN SET PERFORMANCE DATA [HCC PREFIX]

PERFORMANCE DATA [1HZ00788] JULY 09, 2014 For Help Desk Phone Numbers Click here

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS

UNDERSTANDING ROD RATIOS

Troubleshooting guide for poor acceleration, black smoke, and flash code 39, SID 147, FMI 7 or 2

Diesel Engine - Runs Hot Towing or Pulling Grades

Turbocharger Warranty Analysis Guidelines

Filtration Products Extended service filters Increase engine protection Extend service intervals Reduce operating costs

Edelbrock E-Force RPM Carburetor Supercharger Chevrolet LS Engines

1104C-44TA Industrial Diesel Engine

2010 Gmc 2500 Duramax Diesel Owners Manual

Transcription:

ISO 5011 Test Results Certified to the ISO 5011 Air Filtration Standard Replacement Filter for AFE Intake Kit 2006-08 Duramax Chevrolet Silverado & GMC Sierra V8-6.6L Duramax LLY-LBZ S&B Part Number: CR-90038

ISO 5011, Second Edition Performance Testing: Inlet Air Cleaning Equipment for Combustion Engines & Compressors S&B Filters, Inc. 787 South Wanamaker Avenue Ontario, California 91761 (909) 947-0015 (909) 947-0603 www.sbfilters.com ISO 5011Test Results Explanation - Course Test Dust.doc ISO 5011, Second Edition Air Filter or Intake Kit Test Report The test data presented in the following report represents the restriction of airflow, efficiency and dust loading capacity. The filters tested were procured from various distributors or provided by customers. The tests were performed in accordance with ISO 5011. The following were measured in accordance with the test: (1) Pressure Drop for Clean Element, Initial Efficiency and Dust Loading Capacity. The Flow Rate used to conduct the Dust Loading and Capacity test(s) is listed under the Average Environmental Conditions and Test Specifications. PTI ISO Course Test Dust was utilized and the particle data sheet for the batch is attached. The test sequence begins with measuring the pressure drop of a clean filter as a function of the airflow rate which is measured in cubic feet per minute (CFM). Subsequently, the cumulative efficiency and dust loading capacity are measured. The termination point when measuring for capacity is shown at the bottom of the report under the heading Termination ^P. The results of the tests are recorded in the top table and charts shown on the next page. The filters are inspected before and after the tests are performed. The Top Table demonstrates the results of the testing for up to three (3) samples per filter type (part number). The Efficiency represents the amount of dust (contaminants) that was stopped by the filter during each test. The Capacity measures the dust holding capability of the filter. During the test, the filter is loaded with dust until it reaches a terminal pressure drop increase of 10 inches of water (28 H2O for Heavy Duty Vehicles) across the filter element (please refer to the Average Environmental Conditions and Test Specifications at the bottom of the next page to verify the pressure drop utilized on this particular test). The Line Graph shows the pressure drop as a function of the airflow rate for the clean filter(s). The computer controlled test equipment initiates the test at close to zero (0) cubic feet per minute (CFM) and then increases the CFM gradually until the CFM termination point is reached. During the test, the restriction of the filter is measured in inches of water ( H2O) as it relates to the air flow rate (CFM). Visual inspections of filters are performed to insure against dust leakage and manufacturing flaws. The Bar Graph illustrates the cumulative efficiency for the filter(s) tested. Definition of Terms & Test Protocol Restriction Restriction measures how difficult it is for the air to get through the filter and is measured in inches of H2O. Instead of referring to restriction, the industry uses "air flow" to describe the effect of restriction. They say for example, that a High Performance Filter "flows better" than the OEM paper filter. On a line graph, the lower the restriction of a filter the better the air flow. Efficiency Efficiency is measured in % and is the amount of dirt/contaminants that the filter stops from going into the engine. Capacity Capacity is the total amount of contaminants/dirt the filter will hold before reaching its termination point. The termination point is a predefined restriction point that is used as the cut-off point when measuring how much dirt a filter will hold. For typical vehicles, 10 H2O is used at the termination point. For heavy duty trucks, this number is 28 H2O. Note: Testing was conducted based on the ISO 5011 testing standard; however, variances from the actual test procedures may exist. The intent of the testing is to show comparative test results between various products that are intended for similar use. Tests are conducted under a climate controlled environment; however, changes in temperature and humidity between tests may occur which could alter the actual test results.

ISO 5011 Air Filtration Standard AFE Intake Kit Air Filter Comparison S&B Filters CR-90038 Test Number 324 Filter INITIAL RESTRIC. CAPACITY EFFICIENCY Air Flow Net Restriction % Less Restrictive than Mfg. & Part No. ("H2O) (grams) (%) scfm (Inches of H2O) 72-90038AFE Filter #1 6.2 329.0 99.39 0.0 0.000 0.0% S&B Filters 326.3 1.741 18.2% CR-90038 492.0 3.854 13.4% 654.1 6.758 10.2% 820.0 10.361 10.2% 980.9 14.724 9.0% Filter #2 7.2 216.5 99.70 0.0 0.000 AFE 326.7 2.128 72-90038 488.7 4.452 649.1 7.525 812.4 11.538 977.1 16.176 RESTRICTION vs FLOWRATE 14.000 12.000 S&B Filters AFE Avg Restriction (" H2O) 10.000 8.000 6.000 4.000 2.000 0.000 0.0 100.0 200.0 300.0 400.0 500.0 600.0 700.0 800.0 900.0 Flow Rate (cfm) ISO 5011 Air Filtration Test Filter Efficiency % ISO 5011 Air Filtration Test Air Flow Summary 100.00 98.00 S&B Filters 99.39 AFE 99.70 AFE Air Filter p/n 72-90038 96.00 S&B Filters Part Number CR-90038 Flows: 94.00 % 10.2% Better Than AFE at rated CFM 12.2% Better Than AFE Across CFM Spectrum 92.00 90.00 88.00 86.00 1 AVERAGE ENVIRONMENTAL CONDITIONS & TEST SPECIFICATIONS Temperature: 70.80 deg F Housing: uni con Relative Humidity: 50.50 % Contaminant: Coarse Baro Pressure: 29.06 mmhg Contam. Lot #: 5457C Test Stand: #1 Dust Feed Rate: 18.28 grams/minute Inlet Size: 3.875 inches Rated Flow: 653 cfm Testing was conducted based on the ISO 5011 Air Filtration Standard.

Determination of Gasoline and Diesel Engine Air Consumption CFM Calculator: Enter Data in Blue Shaded Areas Engine Displacement (cubic inches) 402.7 Liters to CID Converter Liters: 6.6 RPM at maximum horse power 3,200 Cubic Inches: 402.7 Cycle Factor: 2 Enter "2" for 4 Cycle Diesel and Gasoline Vehicle Information Enter "1" for 2 Cycle Diesel and Gasoline Model Year 08' Volumetric Efficiency: 1.75 Make GM Naturally Aspirated Gasoline & Diesel Engines Enter "0.8" Model Duramax Diesel Super Charged Engines Enter "1.30" Engine Specs 6.6L LMM Turbo V8 Turbocharged Engines Enter "1.75" Based on the information entered above, the estimated CFM of the vehicle at maximum Horse Power is: 653 CYCLE FACTOR Cycle Factor 4 Cycle Gasoline and Diesel Engine 2 2 Cycle Gasoline and Diesel Engine 1 VOLUMETRIC EFFICIENCY Volumetric Efficiency (Approximate) Naturally Aspirated Gasoline & Diesel Engines 0.8 Supercharged Engines 1.30 Turbocharged Engines 1.75 Note: The 1.75 volumetric efficiency is applicable only at top governed engine speed under full load conditions. EQUATION The following is a method of determining approximated gasoline and diesel engine air flow requirement: Air Flow (CFM) = Displacement (cubic inches) x RPM x Volumetric Efficiency 1728 Cycle Factor EXAMPLE Information necessary to calculate air consumption: Ford F250 7.3L V8 Diesel Truck 4 cycle, 2800 RPM@Maximum HP, 445.4 (cubic inches) displacement, turbocharged Air Flow (CFM) : 445.4 x 2800 x 1.75 = 631 CFM 1728 2 \\Server3\official public folder\iso Test Results - Released (Restricted)\AFE Replacements\72-90038 (S&B CR-90038)\CFM Calculator 08' GM 6.6L LMM.xls