Socket Watthour Meters ASK THE EXPERTS OSC is your electric meter expert. When you have questions or need assistance in selecting the proper meter for the job, call us! NEW METERS OSC offers several different brands of new socket base watthour meters for manual reading as well as AMR applications. Meter forms are available for all single-phase and three-phase voltages. For AMR systems, we offer meters with k-y-z pulse output, as well as Landis and Gyr meters which incorporate the Aclara MTU RF Transmitter. REFURBISHED AND REMANUFACTURED WATTHOUR METERS OSC offers a broad line of refurbished meters from many different manufacturers. Refurbished electric meters are usually available with shorter lead times and lower costs than new meters. SENSUS ICON REPAIR AND REPLACEMENT PROGRAM We repair Sensus Icon meters which incorporate the internal Aclara MTU. We offer a stock rotation program which allows you to have replacement meters before the old ones are taken out of service. Socket meters are also available with Aclara R type (pulse) MTU attached to the meter. A Page 36
Landis & Gyr E130 Focus AL Product Specification Sheet E130 FOCUSAL Leading-Edge Technology for Advanced Residential Metering Applications The FOCUS family of metering products provides the utility industry with an advanced, reliable and economical solid-state meter platform for advanced metering applications. The FOCUS AL utilizes a single circuit board design which allows room for installation of a modular communications board or a KYZ option output board. Fewer parts and connectors throughout the design increase reliability and contribute to better overall endpoint performance. Highly accurate load performance and the use of a field-proven Digital Multiplication Measurement Technique ensure reliability and dependability during the entire life of the FOCUS meter. Meter reconfiguration can be accomplished optically through the configuration port located on the front cover. Select from displayable positive, negative, net and added (security) metrics Change the displayed information, order or digits Configure a CT/PT meter multiplier to obtain a direct reading Preset or reset kwh Adjust calibration With a focus on customer satisfaction, we are committed to providing the best metering solution in terms of capability, technology and affordability. By utilizing our experience and technology with that of our strategic allies and development partners, we provide metering solutions that cover the range of utilities residential metering needs. Key Benefits Digital Multiplication Measurement Technique Non-volatile memory Designed for a 20+ year life Meets or exceeds industry and ANSI standards Uses ANSI protocol (between meter and AMR device) 6 digit LCD and 2 Alpha ID Selectable meter multiplier up to 240 (1200:5 CT) Page 37
Product Specification Sheet E130 FOCUS AL Specifications General Specifications Active Energy kwh-only meter Digital Multiplication Measurement Technique Non-Volatile Memory Designed for 20+ years life Meets ANSI standards for performance Utilizes ANSI protocol (between meter and AMI device) 8-Digit LCD Display scroll sequence programmable (factory or end user) Configuration Port cover does not have to be removed Operating Temperature -40C to +85C under cover Nominal Voltage 120V or 240V Operating Voltage 80% to 115% of Vn Frequency 60Hz +/- 5% Humidity 5% to 95% relative humidity, non condensing Starting Load (Watts) Class 20 0.005 Amp (0.6W) Class 100 0.030 Amp (3.6W) Class 200 0.050 Amp (12W) Class 320 0.080 Amp (19.2W) Class 480 0.120 Amp (28.8W) Voltage Burden < 1.8W Max Load Performance Accuracy Accuracy Class 0.5% typical accuracy 0.2% Available Forms Self-Contained 1S, 2S, 2SE, 12S, 25S Transformer Rated 3S, 4S K-Base 2K Display Options Energy Metrics: +kwh, -kwh, Net kwh, and added kwh (Security) Metric Energy Display Format 4x1, 4x10, 5x1, 5x10, 6x1 or 6x10 AMI Platform Modular or Integrated Selectable Meter Multiplier Up to 240 as result of PT ratio CT ratio Applicable Standards ANSI C12.1 for electric meters ANSI C12.10 for physical aspects of watt hour meters ANSI C12.19 Utility Industry End Device Data Tables ANSI C12.20 for electricity meters, 0.2 and 0.5 accuracy classes CAN3-C17-M84 Canadian specifications for approval of type of electricity meters Page 38
Landis & Gyr E650 S4E Product Specification Sheet E650 S4e Enhanced metering for Commercial and Industrial Applications Built on the time-tested platform of the S4, the S4e extends the build-a-meter concept into the realm of open-architecture protocol, fully supporting the ANSI C12.18, C12.19, and C12.21 communication protocol standards. A changing meter for a changing market: The S4e maintains its flexibility with a FLASH technology programmable microprocessor. Field re-programmability via the ANSI standard type II optical port preserves your investment with the evolving requirements of the ANSI protocol, and changing demands of the market. The S4e incorporates 128k of on-board memory storage for load profile, self-reads, and event logs providing an easy upgrade path without the need for an additional option board. Load profile can be configured for up to 15 channels of information from a choice of 24 different storage metrics. The build-a-meter concept provides modular growth in the S4e with software upgrades for time of use, reactive energy metering, transformer loss compensation, load profile as well as the flexibility of adding any combination of communication and relay option boards. The S4e is an AMI friendly meter with the largest space under the cover for AMI integration. A wide range of modular and integrated communication options are currently available, either factory installed or for retrofit. Technologies include power line carrier, mesh network, digital cellular, RS-232, RS-485 and the advanced modem. Load Profile 128K on-board option available Up to 15 channels from choice of 24 metrics available in S4e meter Key Benefits KYZ with Programmable Pulse Output Value EOI Demand Threshold Alert Voltage Threshold Alert Diagnostics Load Control Up to two inputs from external devices Pulses input to load profile Activate real-time rate Optional transformer loss compensation AMI friendly Page 39
Product Specification Sheet E650 S4e Specifications General Specifications Operating Temperature Nominal Voltage Operating Voltage Active Energy kwh-kw and optional Reactive kvah-kva kvarh-kvar Digital Multiplication Measurement Technique Non-Volatile Memory Designed for 20+ years life Meets ANSI standards for performance Utilizes ANSI protocol (between meter and AMI device) 9-Digit LCD Display scroll sequence programmable (factory or end user) -40C to +85C under cover 120 480V Auto Ranging Power Supply 60% to 115% of Vn Frequency 50 or 60Hz ± 5% Humidity Less than or equal to 95% relative humidity, non condensing Accuracy Class Class 20, 120, 200 & 320 Meters ± 0.2% Class 480 Meters and Forms 36S, 29S, 36A ± 0.5% Exception: Form 29 and 36 Over Voltage Withstand Temporary (.5 sec) 150% rated voltage Continuous (5 hours) 120% rated voltage Starting Load (Watts) Class 20 0.005 Amp (0.6W) Class 150 Class 200 Class 320 Class 480 0.050 Amp (6.0W) 0.050 Amp (6.0W) 0.080 Amp (9.6W) 0.120 Amp (14.4W) Available Forms Self-Contained S-Base 2S, 12S, 14/15/16S, 25S, 1S, 2SE, 12SE, 14SE/15SE/16SE, 25SE Applicable Standards Voltage Burden 2.5W Transformer Rated K-Base 12K, 16K/15K, 27K A-Base 16A ANSI C12.1 for electric meters S-Base 3S, 4S, 9S/8S, 45S, 36S, 29S, 56S A-Base 10A/8A, 45A, 36A ANSI C12.10 for physical aspects of watt hour meters ANSI C12.20 for electricity meters, 0.2 and 0.5 accuracy classes CAN3-C12-M84 Canadian Specs for approval of electrical meters CAN3-Z234.4-79 Canadian Specs for all numeric dates and times Page 40
Aclara STAR Network Electric MTU // SUBMETERING STAR Network Electric MTU METER TRANSMISSION UNIT OUTDOOR The STAR Network electric MTU provides the detailed usage profile needed to support modern customer services, advanced billing plans, and electric supplier choice programs. The two-way, electric MTU broadcasts over secure, licensed 450- to 470-MHz radio frequencies, with a range of at least a mile. A backup battery ensures continual operation and receipt of critical data during outages. It transmits up to 288 meter readings per day, maintains clock accuracy, and performs on-demand reads, providing consistent and long-term performance. Each STAR Network Electric MTU delivers Historic data storage Stores up to 30 days of data for retrieval Firmware upgrades over network Uploads new functionality to uninstalled meters C12.19 tables support Supports ANSI/IC standard for meter data interchange Outage and restoration management Provides messaging to support comprehensive outage management Supports modern tariffs Offers accurate interval metering and supports time of use, real-time pricing, and critical peak pricing Additional data Reports account information, meter reading, battery condition, peak demand, tamper status, and outage information Page 41
STAR Network Electric MTU STAR Network Electric MTU System Diagram Client workstations Network Control Computer Application server Database server Data Collector Unit Electric MTU The electric MTU links the meter to the STAR Network system, capturing valuable data and providing the benefits of reliable AMI. STAR Network MTUs are capable of one- or two- way communications. Page 42
Landis & Gyr Focus Watthour Meters with Internal Aclara RF MTU Description Landis & Gyr Watthour meters with internal Aclara RF MTUs are available in both socket and remote CT configurations for Form 2-S (120/240V Edison) and Form 12-S (120/208 Network) electric systems. These meters meet or exceed industry and ANSI standards. Meters include LCD display with 6 digits and 2 alpha characters, non-volatile memory, and are designed for a 20-year life. The internal Aclara RF MTU is a 450-470MHz licensed-frequency transmitter with coverage of up to 1 square mile. In addition to meter readings, back-up battery condition, tamper, outage, and signal strength information is reported. The internal Aclara RF MTU is programmed on-site with a hand-held programmer unit. Socket Meter with MTU and Internal CT(s) Key Benefits Socket-Mount Models for Outdoor or Indoor Installation Proven quality and performance Rugged and Reliable design Millions of metering points installed at utilities throughout the USA and Canada Aclara RF infrastructure also supports 2-way gas and water metering Remote CT models for flush mounting (meter is inside the wall) Wall-Mount Meter with MTU and Remote CT(s) Remote CT Options Split-Core Solid-Core C Page 43
Landis & Gyr Focus Watthour Meters with Internal Aclara RF MTU Specifications General Active Energy kwh-only meter Digital Multiplication Measurement Technique Non-Volatile Memory Designed for 20+ years life (1 year warranty) Meets ANSI standards for performance 8-digit LCD DIMENSIONS Operating Temperature...-40 C to +85 C under cover Nominal Voltage...120Vac or 240Vac Operating Voltage...80% to 115% of Vn Frequency... 60Hz, ±5% Relative Humidity... 5% to 95%, non-condensing Starting Load (Watts)... Class 200, 0.050Aac (12W) Voltage Burden... 1.8W, max. Load Performance Accuracy... Class 0.5%, 0.2% typical Available Forms... 2S, 12S Applicable Standards ANSI C12.1 for electric meters ANSI C12.10 for physical aspects of Watthour meters ANSI C12.19 Utility Industry End Device Data Tables ANSI C12.20 for electricity meters, 0.2 & 0.5 classes DRILL INFORMATION: A. 0.187 DIAMETER (4 PLACES) CONNECTION DIAGRAMS Dwg# 1002-00039-B Rev -- (mod) Page 44 Dwg# 0902-00952-A Rev -- C