Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

Similar documents
JAZZ J400C (COLOR), J400AS (AUTO SYNC)

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

ANTHONY POOL LIGHT FIBERSTARS JAZZ & FX POOL LIGHTS

Underwater Pool Color-Changing LED Light

INTELLIBRITE 5G COLOR POOL AND SPA LIGHTS

INTELLIBRITE 5G WHITE AND COLOR POOL AND SPA LIGHTS

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

POOL BARON Nicheless Color Changing LED Pool Light

poollux Power plx-pw60 & plx-pw100

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

MAGICBOWL WATER EFFECT WITH FIREFX LED LIGHT FOR POOL AND SPA

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

JUNCTION / DECK BOX. - Made of white ABS and push in cover with O-ring seal IP 55 weather protection.

WARNING. Important Notice

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Installation Instructions: Read these instructions in its entirety before performing any installation work.

PART B BRAND SPECIFIC MANUAL

AquaPure Ei TM Series Replacement Kits

INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

IntelliTouch Expansion Center Kit

Installation Instructions: Read these instructions in its entirety before performing any installation work.

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

INSTALLATION INSTRUCTIONS

BRILLIANT WONDERS 1.5" LED LIGHT

Product Manual Manuel du Produit Manual del Producto

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

AquaLuminator Light and Return Water Flow for Above Ground Pools Owner's Manual

ELECTRICAL. 60 Minutes

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

IntelliTouch Pool and Spa Control System Load Center and Power Center

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

6600-AS INSTALLATION MANUAL AUTO SYNCHRONIZED ILLUMINATORS

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Model Numbers SAVI-NOTE75, SAVI-NOTE150

2017 Parts Catalog. Pricing Effective Hayward Elite Above Ground Light (SP056525)

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Installation Manual. CS9300 Professional Series Landscape Lighting System

LED Light Bar. Series LLB. Installation Instructions

SUBMERSIBLE SWIMMING POOL DRAINER

ECET Distribution System Protection. Overcurrent Protection

Elegance Electrician s Installation Guide

8300 Series Installation Guidelines

5300 Series Installation Guidelines

INSTALLATION INSTRUCTIONS

is10 Spa-Side Remote Installation Guide (For IntelliTouch and CP3800 series systems)

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

HPFB. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

LA11 Tail, Parking, And Back-Up

Electrical Safety. Introduction

SPECIFICATION SHEET. Transformers. Cable cord: Core: Timers & Photocell: Wire Rating: Certification: Warranty: OFF. Bottom mounting slot Front View

9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC

P80074 (150 amp connectors) P80071 (300 amp connectors)

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

SUNC3000 / Item #40885

OnCommand Troubleshooting Guide Hayward Industries

Spring Test 10 due 05/11/2013

Applications. Illustrated Features

Hayward Elite Above Ground Light (SP056525) Hayward DuraNiche (SP0600U & SP0607U)

Product Manual Manuel du Produit Manual del Producto

FACT SHEET Standard: Electrical Safety

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine

Jandy Pro Series Water Feature Pump Model WFTR INSTALLATION AND OPERATION MANUAL WARNING ENGLISH

LIGHTING PARTS LIGHTING PARTS REPLACEMENT PARTS FOR LIGHTING

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

LAWN SPRINKLER, IRRIGATION PUMP

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

LEV/Wn Building A Connected World

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Circa Ambient Interior Luminaire

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

High Frequency SineWave Guardian TM

Follow product label information and instructions. Qualified Personnel must perform all servicing or relamping of this product.

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

PRE-DELIVERY GUIDE How to make the delivery and installation of your new hot tub fast, easy, and trouble-free

SpaCommand Spa-Side Remote (For EasyTouch, IntelliTouch and Compool CP3800 Series Control Systems)

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Installing a Downstream Distribution Panelboard

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

HANGING LANTERN ITEM # MODEL #CP199MBK. Français p. 9. Español p. 17 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

Installation and Operation Manual. FloPro Series Pumps WARNING. Model FHPM

Installing Your 220v J-POD Kit

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

Transcription:

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt Owners Manual Fiberstars 44259 Nobel Drive Fremont, CA 94538 www.fiberstars.com 79-15014-00 REV B - 1 -

CAREFULLY READ AND FOLLOW ALL SAFETY INSTRUCTIONS IN THIS MANUAL AND ON THE LIGHT AND ASSOCIATED EQUIPMENT. HAZARDOUS VOLTAGE Incorrectly installed equipment may fail, causing severe injury or property damage. Have a certified electrician perform all test before operating equipment. To prevent the risk of damage or injury, do not operate the light out of water for more then 5 minutes. Allow the light to cool down before installing underwater. ATTENTION FIBERSTARS JAZZ & FX-SPA LIGHTS ARE ETL LISTED FOR USE IN FIBERSTARS WET NICHE TYPE FIXTURE ONLY. Small Underwater Light Niche Model number, FS-N1, (ABS). FIBERSTARS JAZZ & FX Series Spa Wet-Niche Lighting Fixtures are ETL Classified for use in new Spa construction with the following manufactures Wet-Niches: PENTAIR, (American) model no. 78241100 thru 2300 & 78243100 thru 4300 (Stainless Steel), STA-RITE, 05167- XXXX (ABS) 05166-1017 thru 05166-2350 (Stainless Steel) ETL Classification Report No. 30480211 Risk of electrical shock. Before removing fixture from pool wall, ALWAYS TURN OFF THE POWER at the breaker. All 12 Volt lamps require the installation of a 12 Volt transformer. Install this light and light niche in accordance with Article 680 of the National Electrical Code (NEC), in the United States. Install an approved Ground Fault Circuit Interrupter in the electrical circuit for this light. All devices in the system must be directly grounded to a positive electrical ground. All devices in the system must meet all applicable code requirements for bonding. Operating spa light at a reduced voltage will diminish the lighting of your spa during nighttime use. Failure to provide adequate lighting may result in swimming hazards which can cause severe injury or death Long cord length and insufficient voltage will cause reduced light output and unit failure. FX will not operate with less than 9 volts (9v) at the light when loaded. Operate only on 12v loaded transformer voltage with a cord length of under 30ft. See installation manual for further information. 79-15014-00 REV B - 2 -

Loaded Transfo rmer Use Fiberstars FX cord only 30ft 50ft 75ft 100ft Change in Change in Change in 12V 11.8-3% 11.6-8% 11.4-15% Do Not Use Change in 13V Do Not Use Do Not Use 12.2-9% 12 0% 14V DO NOT USE Figure 1 Install fixture in a vertical pool or spa wall not in floor. Failure to install the fixture properly could result in personal injury and/or property damage. The Light Fixture shall be installed in or on a wall of the spa, with the top of the lens opening not less then 18 below normal level of the spa. The junction box must be located: At least 4 from the perimeter of the pool (unless separated from the pool by a solid fence, wall or other permanent structure, At least 8 above maximum water level, At least 4 above the deck or ground level. Junction boxes should be located off the walkway around the pool and given additional protection by installing them next to a fence, building, or other permanent structure. Make sure that the installation is in compliance with local codes, and the NEC. 79-15014-00 REV B - 3 -

A Ground Fault Circuit Interrupter (GFCI) and an appropriately rated circuit breaker shall be installed in the branch circuit supplying power to fixtures so that there is no shock hazard during re-lamping. Lamp Housing Installation Glass breakage hazard. Do not push off from the spa side against the light. Installation of a 12 Volt transformer is required when installing the 12 Volt model of this light. The transformer must be located: At least 10 from the spa wall, Installed near a grounded, 3-prong, 120V, GFCI protected outlet, have a qualified electrician install one. Light Fixture Installation FX & Jazz 1. Before installing light fixture, make sure power to light is off. 2. Feed cord through niche and conduit, while light fixture is on deck area right above the niche. Feed cord to junction box leaving enough cord, about 3 to allow fixture to be placed on deck to allow relamping. 3. For FX-Series Make connections in the junction box (be sure to follow code requirements!). When connecting wires to the junction box, connect supply circuit grounding wire (green, green and yellow, or bare copper) to the green ground conductor from the light fixture. Connect the line supply wire (the black or hot wire) to the black wire from the light fixture. Connect the neutral (white) supply wire to the neutral (white) wire from the light fixture. 4. For Jazz series The JSPAC-100AS is a four wire light for use with Fiberstars Jazz Light. Connect the three wires to the corresponding circuit wires, with the fourth wire connected to the color wheel control switch of the Jazz Light in the Junction Box and secure the Junction Box cover in place. 5. Insert cord into the niche and place the lamp housing in the niche. Be sure that the locator tab on the bottom of the lamp housing is in the notch at the bottom of the niche. 6. Insert the top screw into top hole on niche and tighten. 79-15014-00 REV B - 4 -

MAINTENANCE Hazardous voltage. Electrical shock hazard. Before removing fixture from pool wall, ALWAYS TURN OFF THE POWER at the breaker. Installation and maintenance of this circuit, the light, light niche, and any other accessories attached to this circuit must be performed by a licensed electrician. The complete electrical system must be installed, tested, and approved by a licensed electrician before it is placed in operation. Risk of cuts, burns, and electrical shock. Avoid direct impacts on glass lens. Do not install damaged or broken lens. 1. Be sure that the power is off. Allow the lamp to cool before re-lamping. 2. Loosen the captive leader screw from the top of the fixture trim ring. NOTICE: The screw in the trim rim may be recessed. 3. Remove the lamp housing and place on the pool deck. 4. Remove screw from clamp. 5. Replace gasket. To reassemble the lens assembly to the lamp housing, reverse the disassembly process. Be sure that the lamp housing is clean, dry, and free of all traces of moisture, before sealing the fixture. 6. Insert cord into niche and place the lamp housing back in the niche. Be sure to align the locator tab at the bottom of the lamp housing with the notch in the bottom of the niche. 7. Fasten the lamp housing into the niche using the captive leader screw at the top of the trim ring. Risk of Electrical Shock or Electrocution. This fixture must be properly installed in accordance with the National Electrical Code and all applicable local codes and ordinances by a certified or licensed Electrician. Failure to do so may result in serious injury to occupants, installers, or cause property damage due to the resulting electrical hazards. Read and follow all instructions. Volts and Amp rating for FX12V, FX12VAS and FX120V, FX120VAS are as follows, FX120V (Color) 120 Volts.35 Amps. FX12V (Color) 12 Volts 3.35 Amps Jazz Spa 120 Volts.35 Amps. 79-15014-00 REV B - 5 -

Control Options for FX series FXSPA12VAS-100, FXSPA120VAS-100, & JSPAC-100AS 1. Switch Controlled. a) Jandy RS Controlled or comparable control system. b) Fiberstars RM-400 Wireless Remote Control. FX-AS Light Control and Operating Instructions for FXSPA12VAS-100 and FXSPA120VAS-100 Lights 1. Switch to on position FX turns on and color stays on last color. 2. Switch off/on Within 15 seconds, color wheels will rotate to home and pause, before they begin to rotate in sync. 3. Switch off/on Color wheel stops on color chosen. 4. Switch off/on repeat step #2. 5. Switch off for a minimum of 3 seconds and the unit will reset to step #1. Operation and control for the JSPAC-100AS lights A. Before operating, make sure both the power and color wheel switches are in the off position. (If the color wheel switch is on when the power is activated the Jazz units will not sync.) 1. Switch the power on The Auto Sync units color wheels will rotate to their home position on White. This action takes about 15 seconds. 2. Switch on the color wheels. The JAZZ SPA units are now in sync. 3. When shutting down the system always turn the color wheels off. This will allow the color wheels to reset to their home position the next time the lights are turned on. 79-15014-00 REV B - 6 -

Replacement Parts for Fiberstars JAZZ/FX Series SPA Lights 120-Volts and 12-Volts Item No. Part No. Description 1 2 JSP-1000 JSP-2000 3 4 5 6 7 JSP-3000 JSP-4000 JSP-5000 JSP-6000 JSP-7000 Color Wheel 12V 35W Halogen lamp (includes items 3 and 7) Pilot Screw, with neoprene washer Face ring, Stainless Steel Compression Clamp Lens Lens Gasket 4 7 6 3 5 1 2 79-15014-00 REV B - 7 -