Spectronic-SP Air Circuit Breaker

Similar documents
Spectronic SP Air Circuit Breaker. Protecting people, property & productivity

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity

Record SL. Moulded Case Circuit Breaker

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

Spectra SP. Range of SD & SDF 32A to 800A

GE Consumer & Industrial Power Controls ACB. Spare Parts Manual

Motor Protection Circuit Breaker

cor Long Run Experience

Range : 7.5kW to 630/800kW

01 Spectra Plus - Introduction

ML 1.5 SS91851 ML 2 SS A 25 A 40 A 13.5 A 17 A 37 A 37 A. 6.3 A 15.5 A 15.5 A 12.5 A 23 A 23 A 19 A 830 V 415 V 500 V 3 kvar 120 A

DRX. MCCBs for residential and commercial SYSTEMS FOR ELECTRICAL INSTALLATIONS & INFORMATION NETWORKS.

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

DMX 3 -I 2500 switch disconnectors

Goldline Miniature Circuit Breakers

DRX 125 Circuit breaker (not adjustable)

Switch-Disconnector-Fuse HRC Fuse-links Bolted Type

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DRX 100 B/N/H Circuit breaker (not adjustable)

DPX Thermal magnetic and trip-free switches DPX 3 -I 630


Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

HRC Fuse-links Bolted Type HG 2 A - 32 A HQ 2 A A

DPX 1600 Electronic release

DRX 250 B/N/H Circuit breaker (not adjustable)

Auxiliary Relay. Type RXP8n, RXPQ8n

A9K. MCB, RCCB, Isolator

3 - Protection components Motor circuit-breakers

Indoor Metal Clad Switchgear Type:Cubicle VHA 36 SF6 Circuit Breaker HPA 36 Rated Voltage: ABB Power Distribution

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

DPX moulded case circuit breakers

DPX 630 Electronic release

Thermal magnetic and trip-free switches

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

Memshield - ACB Ratings & Specifications

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Price List. Power Factor. With effect from June 15, Correction Products. With effect from January 03, 2012

iaccl AUTOMATIC CHANGEOVER WITH CURRENT LIMITER

Single Phase Submersible Pump Starters

Bistable Relay. Types PSU6n, PSU14n.

DPX earth leakage DPX 3 -I earth leakage

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

K50H004UP cam changeover switch - 4-pole A - screw mounting

Energy Saving HRC Fuse-Links

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

DC MOTORS. Crompton Greaves EVERYDAY SOLUTIONS

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Auxiliary Relay. Type P8n, PQ8n, PN8n

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

DPX Electronic + earth leakage

OUTDOOR OFF LOAD DISCONNECTORS HCB/HDB Range

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

3VU13, 3VU16 Circuit-Breakers

Energy Saving HRC Fuse-Links

The most widely used motors from the world leaders

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

MEDIUM VOLTAGE SWITCHGEAR

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Protection components

Moulded Case Circuit Breakers New DU Series 20 A to 250 A

Liebert GXT-MT 1-3kVA UPS. Power Protection for Business Critical Continuity

C -5 to +55 (0.8 to 1.1Uc) Permissible o

LV- Power Quality Products and Systems

SWITCH FUSES 3KL71 from 32A to 800A Description


Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Auxiliary Relay. Type CV2

max pole for t=15 ms

LV- Power Quality Products and Systems

DPX Magnetic only

C60H-DC C curve. Catalogue numbers

K30H001YP cam star-delta switch - 3-pole A - screw mounting

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.

Molded Case Circuit Breaker

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Catalog. Low voltage General performance IE3 efficiency cast iron motors

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.

LET THE SUN POWER YOUR HOME

SPnorm & SPbloc Self Priming Centrifugal Pumps

Harmony Ø 22 Control and Signalling units

Thermal overload relays Type TA Class 10

Vistop TM isolating switches 63 to 160A

Essential equipment for all your requirements

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

Motor Protection Circuit Breakers

Quality Products, Prompt Service, Trustful Relationships.

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Transcription:

Spectronic- Air Circuit Breaker Circuit Breakers 800 to 2500A Series Rated Short circuit breaking capacity : lcs 50 to 55KA ( 4 15V) Complete range Fixed with manual control 3 or 4 poles Electrical control and withdrawable version (available on request) The ECTRONIC range combines the legendary reliability of our air circuit breakers with: A design adapted to the new panel boards Static protection release: LMZ 7 Main advantages Rated short-circuit breaking capacity Following lec 947-2 (415V) Icu (ka) 60 55 800 1000 1250 1600 2000 2500 Clever design combining longevity and reliability Maximum service: total selectivity is ensured, even at Closing on short circuit Simple and efficient servicing on site Safety ensured by fully visible breaking. 0 800 1000 1250 1600 2000 2500 1th (A) Conformity The circuit breakers are built according to the following standards: IEC 947-2, BS, CEI, NBN, NFC and VDE. Certification: Bureau Veritas, Lloyd's Register of Shipping, ASEFA. Certification: Germanischer Lloyd (in accordance with IEC 157.1) Tropicalisation Class 1 (standard): Relative humidity of 80% at 400c (Hot and dry or damp climate of temperature zones). Class 11: Relative humidity of 95% at 450C (Hot and damp climate). Anti-corrosion treatment For special atmospheres, consult us. 02

Spectronic- Air Circuit Breaker Characteristics Circuit Breakers 800 1000 1250 1600 2000 2500 Rated insulation voltage Ui (V) 1000 1000 1000 10000 1000 1000 Rated impulse voltage Uimp (kv) 8 8 8 8 8 8 (4) Rated maximum nominal voltage Ue (V) 690 690 690 690 690 690 Rated thermal current 1th 0 40 C (A) 800 1000 1250 1600 2000 2500 0 50 C (A) 800 1000 1250 1600 2000 2500 0 60 C (A) 800 1000 1250 1500 1900 2350 Rated ultimate short-circuit breaking capacity 1cu Alternating current 50/60 Hz 240/ 415 V (ka) 55 55 55 55 60 60 500 V (ka) 35 35 35 35 35 35 (1) 690 V Rated services short-curcuit breaking capacity lcs (ka) 40 40 40 40 40 40 Alternating current 50/60 Hz 240/ 415 V (ka) 50 50 50 50 55 55 500 V (ka) 35 35 35 35 35 35 (1) 690 V (ka) 40 40 40 40 40 40 Rated services short circuit breaking capacity (max) 1cm (ka peak) 120 120 120 120 130 130 Rated short time withstand current 1cw: 1 sec. 415 V (ka eff.) 50 50 50 50 55 55 500 V (ka eff.) 35 35 35 35 35 35 Utilization category B B B B B B Number of poles 3-4 3-4 3-4 3-4 3-4 3-4 Suitable for isolation (visible breaking indication) Endurance (number of operating cycles) Mechanical (total) #operating cycles 10000 10000 10000 10000 10000 10000 Electrical (at 415 V) (2) #operating cycles 10000 10000 10000 10000 5000 3500 Mean time between maintenances #operating cycles 1500 1500 1500 1500 1500 1500 Power dissipation (withdrawable, 3 poles) (W) 150 200 300 400 450 500 4 th pole conventional current (A) 800 1000 1250 1600 1250(3) 1250(3) Pollution degree 3 3 3 3 3 3 Dimensions in mm (fixed version) 3 poles Height (mm) 462 462 462 462 462 462 width (mm) 370 370 370 370 464 464 Depth (mm) 273.5 273.5 273.5 273.5 273.5 273.5 4 poles Height (mm) 462 462 462 462 462 462 Width (mm) 458 458 458 458 52562 Depth (mm) 273.5 273.5 273.5 273.5 273.5 273.5 (1) On request. (2) To guarantee this number of operations, it is necessary to check the spark Arresters and the arc chutes as shown in the table above (Replace them when necessary) This can be done easily on site (3) Neutral reduced to the le f t (4) Standard operating Voltage at 500V, 690V with Special arc chutes 03

Spectronic- Air Circuit Breaker LMZ 7: Protection unit for 800 to 2500 Standard protection - Overload protection (LT) - Short-circuit protection (ST) - EF protection (GF) Setting ranges Setting points LT (x ln) 0.5 0.6-0.7 0.8 0.9 1 LTD (S) 3s delay at 6 lr ST, l >> (x lr) 3-4 - 5 6 8 9 ST delay,t >> (ms) lnst 200 300 400 GF, lo (x ln) 0.2 0.3 0.4 0.5 0.6 0.7 Time delay (ms) 200ms + ST delay (t >>) setting lr = k x ln k = L.T.setting Note For GF protection in 3 Phase 4 wire system, the fourth CT must be used Description The LMZ release is static unit which meets the requirement of the IEC 60947-2/IS 13947-2 standard. This unit is self powered (thru CTs) and performs all the necessary three or four pole protections. Configuration LMZ 7 is available in two configurations: - 3 pole or 4 pole protections. - 3 pole or 4 pole with ground fault. Features: Inverse square time-current characteristics for closer thermal protection Self-powered trip device. No. need for auxiliary supply Completely static device, hence no derating due to ambient temperature Test facility available Settings easily adjustable by push wheel switches No moving parts in the relay Maintenance free The 3-phase over-current element is designed to be used in single phase applications also Three phases adjusted simultaneously with one control High accuracy, reliability and repeatability Total integration and protection of circuit breaker in a single release Inbuilt earth fault protection Optional: 1. Distinct fault signaling (LT, ST-1, GF) displayed thro LPGS. 04

Spectronic- Air Circuit Breaker LMZ 7: Protection unit for 800 to 2500 Setting and operating current values. 1000 100 Tripping Time (Seconds) 10 1 0.1 0.01 1 10 100 1000 Multiples of current setting 05

LMZ 7: protection and monitoring unit Spectronic- Air Circuit Breaker Diagram showing de-energised circuits, open circuit breaker, connected, reset, handles not inserted. Secondary disconnector Fault Option Protection unit Faults signaling by relay Faults contacts Legend Overcurrent releases BA Overload and short-circuit fault contact K1 Fault signaling relay R1 Booster voltage for 220V S1 Fault cancelling push-button GF Ground fault indicator lamp ST-1 Instantaneous or short duration (short - circuit) tripping indicator lamp LT Long time trip (overload) tripping indicator lamp Voltmetric releases C41 Trip contact UVR - UVRD C43 Undervoltage contact UVR -UVRD C31 Trip contact EA Ra-R6 Booster resistor for certain direct current voltages S1 Optional disconnecting switch UVR -UVRD (break out of service) Operation with energy storage M Motor FCA Resetting limit switch Manual setting CA 1-8 Auxiliary contacts EF Closing coil S2 Remote tripping control S5 Remote closing control S3 Remote closing and tripping control changeover switch C22 Reset contact of the spring C20 Contact coupled with local reset tripping Push-button FE Closing prevention device Withdrawable C51.52 Contacts 'connected' position C61.62 Contacts 'withdrawn' position C71 Pre-trip contact couple with insertion control 06

Spectronic- Air Circuit Breaker Fixed circuit breaker Rear horizontal connections Neutral D B B C E Door Gasket 4X 9 20.5 87 15 462 420 254 237 27 26 34 14 278 A 14 22 26 22 4X 9 200 273.5m in 320 99.5 Panel cut out for fitting gasket Rear horizontal connections 800-1000 13 30 15 300 25 50 3 Sp 1250-1600 neutral of 2000-2500 3 13 352 30 15 25 50 12.5 Legend Type Number Of poles A B C D Sp 800 to 1600 3 318 98 75-2000-2500 3 412 130 90-4 510 130 90 114 2000-2500 E= minimum clearance distance above the arc chutes. Ue < - 500V Ue < - 690V I= Insulating screen 150mm 150mm M= Metallic screen 150mm 200mm 07

REGIONAL OFFICES BRANCH OFFICES NORTH 71/1, Shivaji Marg New Delhi - 110 015 Tel: 011-2592 8185 / 86 / 87 Fax: 011-2592 8088 CHANDIGARH SCO 145-146, 2nd Floor Cabin - 17, Madya Marg Sector 8-C Chandigarh - 160 008 Tel: 0172-2549 416/417 Fax: 0172-2545 249 JAIPUR 448, 4th Floor Ganapati Plaza, M.I. Road Jaipur - 302 001 Tel: 0141-2368 872 / 8040/ 2388 675 Fax: 0141-5112 802 LUCKNOW 101, Ace Business Center 19, Vidhan Sabha Marg Lucknow - 226 001 Tel/Fax: 0522-2237 564 LUDHIANA SCO-137, Feroz Gandhi Market Ludhiana - 141 001 Tel: 0161-5011 193 / 2772 985 Fax: 0161-2773 867 EAST Berger House, 4th Floor 129, Park Street Kolkata - 700 017 Tel: 033-2227 7006 / 7007 Fax: 033-2227 7003 BHILAI 25/1, SBI Colony Motilal Nehru Nagar (W) Bhilai - 490 020 Tel: 0788-5040 462 Fax: 0788-5036 116 BHUBANESHWAR 252 / A, Lewis Road, 2nd Floor, Behind Goutam Petrol Bunk Bhubaneshwar - 751 016 Tel: 0674-441 538 Fax: 0674-443 033 GUWAHATI Ganesh Bhavan 2nd Floor Rajgarh Road Guwahati - 781 001 Tel: 0361-2452 481 Fax: 0361-2459 060 JAMSHEDPUR House No. 330, Road No.7 Sonari New West Layout Jamshedpur - 831 O11 Ph: 0657-3120 525 Fax: 0657-424 056 SOUTH Temple Towers, 6th Floor, 476, Anna Salai, Nandanam Chennai - 600 035 Tel: 044-2432 9179 / 80 53776 / 769 Fax: 044-2433 7325 BANGALORE No: 42/1 & 45/14 Electronic City, Phase II Bangalore - 560 100 Tel: 080-2852 8355 Fax: 080-2852 8366 COIMBATORE Chenny's Chambers 1st Floor No:81, Off Dr. Nanjappa Road Coimbatore - 641 018 Tel: 0422-5393 520 Fax: 0422-5393 529 KOCHI Mayur Business Centre Chittur Road Pullepady Junction Kochi - 682 035 Tel: 0484-2364 139 Fax: 0484-2354 262 SECUNDERABAD 2nd Floor, 5-4-187 / 3&4 /10 Pearl "N" Necklace Complex, Karabala Maidan M. G. Road Secunderabad - 500 003 Tel: 040-5531 1264 Fax: 040-2754 3162 WEST Solitaire Corporate Park Bidg., No. 5, 6th Floor, 151, M. Vasanji Road Chakala, Andheri (E) Mumbai: 400 093 Tel: 022-2826 4819 / 2825 5420 Fax: 022-2825 5410 INDORE 838, 8th Floor, Industry House 15, AB Road Indore - 452 001 Tel: 0731-5066 838 Fax: 0731-5066 859 PUNE Office No. 203, 2nd Floor Sohrab Hall, Sasoon Road Pune - 411 001 Tel: 020-2605 9361 / 2605 9585 Fax: 020-2605 9666 NAGPUR Flat No. 101, Atharva Aptms Nelco Society Subhash Nagar Nagpur - 440 022 Tel: 0712-5646 232 Fax: 0712-2240 992 AHMEDABAD 405-406, Kirtiman Complex Kinariwala House, Behind Citibank, Off. C.G. Road Ahmedabad - 380 009 Tel: 079-5542 7386 Fax: 079-2646 0637 BARODA Pan Asia Executive Centre 606, Citadel, R.C. Dutta Road Windsor Plaza Complex, Alkapuri Baroda - 390 007 Tel: 0265-2331 578 / 2359 038 Fax: 0265-2331 505 / 2341 316 We are committed to continuous development and improvement of our products and the specifications are subject to change without notice. Please contact our nearest sales office for confirmation. KP/AM/S/02 05 No: 42/1 & 45/14 Electronic City - Phase II Bangalore - 560 100, India. Tel: 080-2852 8355 Fax: 080-2852 8366 E-mail: gepc.components@geind.ge.com www.gepowercontrols.com/india