Series variation. Auxiliary valve. Quick exhaust, and circuit switchover valves, etc. are available. Port size (Rc) Page. Model Product appearance

Similar documents
Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure,

R1000/R3000/R4000/R8000 Series

New Products. Speed Control Valve with Adjusting Dial. DSC series SPEED CONTROL VALVE WITH ADJUSTING DIAL DSC SERIES. Visible Flow Rate!

Flowsensor for compressed air

Free position locking flat and compact cylinder UFCD Series

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

HMV/HSV. Manual selector valve. 4-port valve CONTENTS

Flow sensor for compressed air

Series variation. Speed control valve SC* For 2.5 to 450 cylinders. * Refer to page 854 for line type.

Flow sensor for compressed air

ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance.

Vacuum pump system type

HN B G1/US B G2/US B G3

Light weight clamp cylinder CAC-N32/40 Series Light weight position locking clamp cylinder UCAC-N32/40 Series

INSTRUCTION MANUAL FOR

CVE2/CVSE2 CVE3/CVSE3

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption

Mechanical power cylinder

F1000/F3000/F4000/F8000 Series

New Products. 3 Port Solenoid Valve with Spool Position Detection SNP Series

HMV/HSV. Manual switching valve. 4 port valve

Compact direct acting precision regulator

Energy efficiency and Flow

Ready for outdoor use too!

Design & Selection. Installation & Adjustment

Exhaust Throttle (Needle) Valve ET

2 port pilot operated solenoid valve

Push-In Fitting Type Quick Exhaust Valve

Compact direct acting precision regulator

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center)

F.R.L. unit modular type

Speed Controller High Flow

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Standard Specifications. Fluid Standard specifications. VH600 Ambient and fluid temperature Operating angle Lubrication. Optional Specifications

Features. Maintenance is simplified with the separable scraper section adapter.

Specifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/8 NPT 1/4

ROD SLIDERS INDEX ACTUATORS GENERAL CATALOG. Characteristics 779. Handling Instructions, and Precautions 783

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!

Balancing Unit BBS Series

SD Bendix M-21 and M-22 AntiLock Modulator Assembly DESCRIPTION M-21 MODULATOR M-22 MODULATOR

Specifications. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Related vacuum products

Two Hand Control Valve

Super-Mini Complete with Easy-to-Use Functions. Guided Cylinder. STM Series GUIDED CYLINDER STM SERIES CC-884A 1

PD3/PDV3-20A/25A/40A Series

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.

Specifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard

Discrete air operated 2 port valve (compact cylinder valve) NC (normally closed) type

GUIDED CYLINDER STG SERIES

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

Throttle (Needle) Valve PP Series

ACTUATORS GENERAL CATALOG

Soft Start-up Valve. AV2000/3000/4000/5000 Series

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

Miniature Regulator Series ARJ310

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Electronic pressure switch for air

Modular design SELEX F.R.L. Components for air preparation / pressure adjustment / F.R.L. unit CONTENTS. Modular design (rotary actuator F.R.L.

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

TECHNICAL DATA 1-1/2 (dn40)

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard

Multi-Circuit Rotary Block

EV2000 Series. Specifications. Descriptions Working fluid Max. working pressure Min. working pressure Withstanding pressure

Guide Table. ø40, ø63, ø100

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

Selection according to the system

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

Low Maintenance Filter

Doc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME:

Air Operated Valve Control Valve

SUB-LINE FILTERS CONTENTS

Technical information for LFU20-Z07-3A-X2

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

ACTUATORS GENERAL CATALOG

L1000/L3000/L4000/L8000-W Series

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

ARM1000/2000. Standard Specifications

MULTISTAGE MICRO EJECTORS

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Vacuum / Release Unit

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B

SD Bendix SR-5 Trailer Spring Brake Valve DESCRIPTION PORTS. 1-1/2" or 3/4" NPT Spring Brake Reservoir Mounting (SPR BK RES)

How to Order. Body size

Model Pressure range ON/OFF output Linear output

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

SD Bendix MV-1 Modutrol DESCRIPTION

Pilot operated 2 port valve for dust collector control (pulsejet valve) Common specifications Air operated type. Solenoid valve mounted type Item OUT

ACTIVAL Two-way Ball Valve with Threaded-end Connection

INSTRUCTION MANUAL HEAVY DUTY TYPE PNEUMATIC CYLINDER 10A-2V2 (K2) SERIES

YT-520S YT-520D YT-525S YT-525D YT-530S YT-530D YT-535S YT-535D

Low Maintenance Filter

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

Transcription:

Series variation Quick exhaust, and circuit switchover valves, etc. are available Model Product appearance Model no. Port size (Rc) Page 4 dia. dia. M /8 /4 /8 / /4 /4 / QEV-A Quick exhaust valve QEV-8A QEV-0 QEV- QEV-0 QEV- 0 SHV-A Shuttle valve SHV-8A SHV-0 SHV- SHV-0 4 SHV- Small check valve with push in joint CHL-M4 CHL-H44 CHL-H 8 CHV- CHV-8-J CHV-8 CHV-0-J CHV-0 CHV- CHV-0 0 CHV- CHV- CHV-40 4

Pneumatic components (auxiliary valve) Safety Precautions Read this before starting use. Please refer to Intro 4 for general details on the pneumatic components, and to " Precautions" in this section for detailed cautions pertaining to each series. Safety Refrigerating Desiccant High polymer membrane dryer CAUTION Use this product within the proper specified range. Contact CKD when using the product outside specifications or for special applications. If used outside specifications, product functions may not be attained and safety cannot be guaranteed. There are cases when this product cannot be used for special applications or in special environments. These include special applications requiring safety including nuclear energy, railroad, aviation, vehicle, and medical devices or applications coming into contact with beverages or food, amusement equipment, emergency shutoff circuits, press machines, brake circuits, and safety devices. Check that the product can withstand the working environment. This product cannot be used in an environment where functional obstacles could occur. This includes high temperatures, a chemical atmosphere, or where chemicals, vibration, moisture, water drip or gas are present, or an environment where ozone is generated. Do not use this product where cutting oil, coolant, or spatter could contact. Fully understand characteristics of compressed air before designing the pneumatic circuit. If instantaneous stopping and holding are required during an emergency stop, functions equivalent to mechanical, hydraulic or electrical methods cannot be anticipated. Pop out, ejection, and leaks are caused by air compressibility and expansion. Design & Selection 4 This product cannot be used as a stop valve with zero leakage. Slight leakage is allowed in product specifications. Install a "pressure switch" and "shut-off valve" on the device's compressed air supply side. The pressure switch is used to disable operation if set pressure cannot be reached. The shut-off valve exhausts compressed air in the pneumatic circuit, and prevents accidents caused by operation of the pneumatic devices by residual pressure. Indicate the maintenance conditions in the device's instruction manual. The product's function can drop markedly with working status, working environment, and maintenance, and can prevent safety from being attained. With correct maintenance, the product functions can be used to the fullest. 7 Rubber parts deteriorate and life is shortened if very dry air is used. Air filter Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer / others Joint / tube F. generator auxiliary / pad Mechanical dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water 47

Pneumatic components (auxiliary valve) Safety Precautions Read this before starting use. Please refer to Intro 4 for general details on the pneumatic components, and to " Precautions" in this section for detailed cautions pertaining to each series. Safety Piping CAUTION Do not remove the package or seal cap on the piping port until just before piping the product. If the piping port cap seal is removed before piping work is started, foreign matter could enter the pneumatic component and result in failure or malfunction. When connecting pipes, wrap sealing tape in the opposite direction from threads starting mm inside from the end of piping threads. If sealing tape protrudes from pipe threads, it could be cut when screwed in. This could cause the tape to enter the solenoid valve and lead to faults. Installation & Adjustment 4 Always flush just before piping pneumatic component. Any foreign matter that has entered during piping must be removed so it does not enter the pneumatic component. When supplying compressed air for the first time after connecting pipes, do not apply high pressure suddenly. Piping connection could be dislocated or the piping tube fly off, leading to accidents. When supplying compressed air for the first time after connecting pipes, confirm that no air is leaking from any pipe connections. Apply a leakage detection agent on pipe connections with a brush, and check for air leaks. 7 Tighten pipes with the appropriate torque. Pipes must be connected with the appropriate torque to prevent air leakages and screw damage. Handling push in piping joints and tubes Refer to WARNGs and CAUTIONs for the joint and tube (pages 7 to 77) for details on handling push in piping joints and tubes. First tighten the screw by hand to prevent damage to screw threads, then use a tool. Do not retighten while pressure is applied. [Recommended tightening torque] Set screw Tightening torque N m M.0 to. Rc/8 to Rc/4 to 8 Rc/8 to Rc/ to 8 Rc/4 9 to 40 Rc 4 to 70 48

Refrigerating Desiccant High polymer membrane dryer Air filter CAUTION 8 Pipe so that piping connection does not deviate by the device's movement, vibration, tension, etc. Control of actuator speed will be disabled if piping on the exhaust side of the pneumatic circuit is disengaged. When using the chuck holding mechanism, the chuck will be released creating a hazardous state. 9 Secure sufficient space around pneumatic components for installation, removal, and piping work. 0 Install an air filter just before the circuit using the pneumatic components. WARNG Stop air and confirm that there is no residual pressure before replacing the tube. Installation & Adjustment During use & Maintenance Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer / others Joint / tube F. generator auxiliary / pad Mechanical dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water 49

Quick exhaust valve QEV Series Increased speed of exhaust from cylinder, etc. High efficient air circuit will be realized. Port size: Rc/8 to Rc JIS symbol CAD DATA AVAILABLE. Specifications Descriptions Working fluid Max. working pressure MPa Min. working pressure MPa Withstanding pressure MPa Cracking pressure MPa Ambient temperature C / Port size Rc Product mass g QEV-A QEV-8A QEV-0 QEV- QEV-0 QEV- Compressed air.0 0.0. 0.0 to 0 /8 /4 /4 /4 /8 / / / /4 80 0 000 Effective sectional mm area 8 9 7 79 7 0 How to order QEV A A Port size A 8A 0 0 Rc/8 Rc/4 Rc/8 Rc/ Rc/4 Rc Flow characteristics QEV-A QEV-8A QEV-0 /... m/min.. 0. 0. Primary pressure MPa 0. 0. 0. 0. 0.. 4... m/min.. 0. 0. Primary pressure MPa 0. 0. 0. 0. 0. 0 9 8 7 9 8 7 m/min 4 4 XH Primary pressure MPa 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0 QEV-0 / 40 0 m/min 0 0 0 0 0 Primary pressure MPa 0. 0. 0. 0. 0. 0. 0. 0. 0. 0.

Internal structure and parts list QEV-A / 8A QEV-0 to 4 QEV Series Internal structure and parts list 4 Refrigerating Desiccant High polymer membrane dryer Air filter Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer No. Parts name Material No. Parts name Material Main body Aluminum die casting 4 O ring Nitrile rubber Plug Valve Aluminum die casting Nitrile rubber Hexagon socket head cap screw Steel Spring washer Steel Operational explanation EXT EXT Precautions The valve closes (exhaust port) by compressed air entered from, and the air flows to passing through around the packing seal. If pressure of side is dropped, the valve closes port, while opens (exhaust port) to exhaust air from side. Applications No. Parts name Material No. Parts name Material Main body Aluminum die casting 4 O ring Nitrile rubber Hexagon socket Plug Aluminum die casting head cap screw Steel Packing seal Nitrile rubber Spring washer Steel () Usage to increase exhaust speed of air cylinder. Air cylinder Exhaust () Usage to increase exhaust speed of clutch (or brake). Clutch (or brake) Quick Quick exhaust valve Quick exhaust valve exhaust valve port valve port valve The installation attitude is free, however in the range where differential pressure is small (0.0MPa or less), the action may slow. So, care should be taken. / others Joint / tube F. generator auxiliary / pad Mechanical dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water Quick exhaust valve

QEV Series Dimensions QEV-A / 8A (File name: Page 7 or Ending ) Serial no. label. Rc/8, /4 40 4 Rc/4. Label Rc/8, /4. QEV-0 / (File name: Page 7 or Ending ) 4 7 0 40 8 dia. QEV-0 / (File name: Page 7 or Ending ) 4. 0. 4 0 0 90 dia. Model no. / QEV-A QEV-8A QEV-0 QEV- QEV-0 QEV- Rc/8 Rc/4 Rc/8 Rc/ Rc/4 Rc Rc/4 Rc/ Rc