Series variation Quick exhaust, and circuit switchover valves, etc. are available Model Product appearance Model no. Port size (Rc) Page 4 dia. dia. M /8 /4 /8 / /4 /4 / QEV-A Quick exhaust valve QEV-8A QEV-0 QEV- QEV-0 QEV- 0 SHV-A Shuttle valve SHV-8A SHV-0 SHV- SHV-0 4 SHV- Small check valve with push in joint CHL-M4 CHL-H44 CHL-H 8 CHV- CHV-8-J CHV-8 CHV-0-J CHV-0 CHV- CHV-0 0 CHV- CHV- CHV-40 4
Pneumatic components (auxiliary valve) Safety Precautions Read this before starting use. Please refer to Intro 4 for general details on the pneumatic components, and to " Precautions" in this section for detailed cautions pertaining to each series. Safety Refrigerating Desiccant High polymer membrane dryer CAUTION Use this product within the proper specified range. Contact CKD when using the product outside specifications or for special applications. If used outside specifications, product functions may not be attained and safety cannot be guaranteed. There are cases when this product cannot be used for special applications or in special environments. These include special applications requiring safety including nuclear energy, railroad, aviation, vehicle, and medical devices or applications coming into contact with beverages or food, amusement equipment, emergency shutoff circuits, press machines, brake circuits, and safety devices. Check that the product can withstand the working environment. This product cannot be used in an environment where functional obstacles could occur. This includes high temperatures, a chemical atmosphere, or where chemicals, vibration, moisture, water drip or gas are present, or an environment where ozone is generated. Do not use this product where cutting oil, coolant, or spatter could contact. Fully understand characteristics of compressed air before designing the pneumatic circuit. If instantaneous stopping and holding are required during an emergency stop, functions equivalent to mechanical, hydraulic or electrical methods cannot be anticipated. Pop out, ejection, and leaks are caused by air compressibility and expansion. Design & Selection 4 This product cannot be used as a stop valve with zero leakage. Slight leakage is allowed in product specifications. Install a "pressure switch" and "shut-off valve" on the device's compressed air supply side. The pressure switch is used to disable operation if set pressure cannot be reached. The shut-off valve exhausts compressed air in the pneumatic circuit, and prevents accidents caused by operation of the pneumatic devices by residual pressure. Indicate the maintenance conditions in the device's instruction manual. The product's function can drop markedly with working status, working environment, and maintenance, and can prevent safety from being attained. With correct maintenance, the product functions can be used to the fullest. 7 Rubber parts deteriorate and life is shortened if very dry air is used. Air filter Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer / others Joint / tube F. generator auxiliary / pad Mechanical dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water 47
Pneumatic components (auxiliary valve) Safety Precautions Read this before starting use. Please refer to Intro 4 for general details on the pneumatic components, and to " Precautions" in this section for detailed cautions pertaining to each series. Safety Piping CAUTION Do not remove the package or seal cap on the piping port until just before piping the product. If the piping port cap seal is removed before piping work is started, foreign matter could enter the pneumatic component and result in failure or malfunction. When connecting pipes, wrap sealing tape in the opposite direction from threads starting mm inside from the end of piping threads. If sealing tape protrudes from pipe threads, it could be cut when screwed in. This could cause the tape to enter the solenoid valve and lead to faults. Installation & Adjustment 4 Always flush just before piping pneumatic component. Any foreign matter that has entered during piping must be removed so it does not enter the pneumatic component. When supplying compressed air for the first time after connecting pipes, do not apply high pressure suddenly. Piping connection could be dislocated or the piping tube fly off, leading to accidents. When supplying compressed air for the first time after connecting pipes, confirm that no air is leaking from any pipe connections. Apply a leakage detection agent on pipe connections with a brush, and check for air leaks. 7 Tighten pipes with the appropriate torque. Pipes must be connected with the appropriate torque to prevent air leakages and screw damage. Handling push in piping joints and tubes Refer to WARNGs and CAUTIONs for the joint and tube (pages 7 to 77) for details on handling push in piping joints and tubes. First tighten the screw by hand to prevent damage to screw threads, then use a tool. Do not retighten while pressure is applied. [Recommended tightening torque] Set screw Tightening torque N m M.0 to. Rc/8 to Rc/4 to 8 Rc/8 to Rc/ to 8 Rc/4 9 to 40 Rc 4 to 70 48
Refrigerating Desiccant High polymer membrane dryer Air filter CAUTION 8 Pipe so that piping connection does not deviate by the device's movement, vibration, tension, etc. Control of actuator speed will be disabled if piping on the exhaust side of the pneumatic circuit is disengaged. When using the chuck holding mechanism, the chuck will be released creating a hazardous state. 9 Secure sufficient space around pneumatic components for installation, removal, and piping work. 0 Install an air filter just before the circuit using the pneumatic components. WARNG Stop air and confirm that there is no residual pressure before replacing the tube. Installation & Adjustment During use & Maintenance Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer / others Joint / tube F. generator auxiliary / pad Mechanical dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water 49
Quick exhaust valve QEV Series Increased speed of exhaust from cylinder, etc. High efficient air circuit will be realized. Port size: Rc/8 to Rc JIS symbol CAD DATA AVAILABLE. Specifications Descriptions Working fluid Max. working pressure MPa Min. working pressure MPa Withstanding pressure MPa Cracking pressure MPa Ambient temperature C / Port size Rc Product mass g QEV-A QEV-8A QEV-0 QEV- QEV-0 QEV- Compressed air.0 0.0. 0.0 to 0 /8 /4 /4 /4 /8 / / / /4 80 0 000 Effective sectional mm area 8 9 7 79 7 0 How to order QEV A A Port size A 8A 0 0 Rc/8 Rc/4 Rc/8 Rc/ Rc/4 Rc Flow characteristics QEV-A QEV-8A QEV-0 /... m/min.. 0. 0. Primary pressure MPa 0. 0. 0. 0. 0.. 4... m/min.. 0. 0. Primary pressure MPa 0. 0. 0. 0. 0. 0 9 8 7 9 8 7 m/min 4 4 XH Primary pressure MPa 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0 QEV-0 / 40 0 m/min 0 0 0 0 0 Primary pressure MPa 0. 0. 0. 0. 0. 0. 0. 0. 0. 0.
Internal structure and parts list QEV-A / 8A QEV-0 to 4 QEV Series Internal structure and parts list 4 Refrigerating Desiccant High polymer membrane dryer Air filter Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer No. Parts name Material No. Parts name Material Main body Aluminum die casting 4 O ring Nitrile rubber Plug Valve Aluminum die casting Nitrile rubber Hexagon socket head cap screw Steel Spring washer Steel Operational explanation EXT EXT Precautions The valve closes (exhaust port) by compressed air entered from, and the air flows to passing through around the packing seal. If pressure of side is dropped, the valve closes port, while opens (exhaust port) to exhaust air from side. Applications No. Parts name Material No. Parts name Material Main body Aluminum die casting 4 O ring Nitrile rubber Hexagon socket Plug Aluminum die casting head cap screw Steel Packing seal Nitrile rubber Spring washer Steel () Usage to increase exhaust speed of air cylinder. Air cylinder Exhaust () Usage to increase exhaust speed of clutch (or brake). Clutch (or brake) Quick Quick exhaust valve Quick exhaust valve exhaust valve port valve port valve The installation attitude is free, however in the range where differential pressure is small (0.0MPa or less), the action may slow. So, care should be taken. / others Joint / tube F. generator auxiliary / pad Mechanical dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water Quick exhaust valve
QEV Series Dimensions QEV-A / 8A (File name: Page 7 or Ending ) Serial no. label. Rc/8, /4 40 4 Rc/4. Label Rc/8, /4. QEV-0 / (File name: Page 7 or Ending ) 4 7 0 40 8 dia. QEV-0 / (File name: Page 7 or Ending ) 4. 0. 4 0 0 90 dia. Model no. / QEV-A QEV-8A QEV-0 QEV- QEV-0 QEV- Rc/8 Rc/4 Rc/8 Rc/ Rc/4 Rc Rc/4 Rc/ Rc