Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Similar documents
Sentinel D-Box Twin Fan

Sentinel D-Box Single Fan

NEW Slimpak EC Box Fan (SLPT EC)

NEW Acoustic In-Line Fans (ACQ)

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Acoustic Twin Fans (ATQ)

Square Mixed Flow Fans (MFQ)

Mixed Flow Roof Fans (RMH)

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

QUIETSCROLL TWIN FAN RANGE

Mixed Flow Roof Fans (RMH)

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Sabre Plate Mounted Sickle Fans (VSP)

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

HIGH TEMPERATURE TWIN SQUIF FANS

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Bifurcated Case Axial Fans (BIFA)

Performance. Sound Levels. Impellers. Motors. Accessories

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

BOX BLB Centrifugal Box Fan

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

TWINFLOW STDR Product Brochure

Vent-Axia Sabre Sickle Roof Fans (VSR)

ifan Copford Box Range

BATHROOM EXTRACT FANS DECOR-100 Series

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

GigaBox centrifugal fans Product specific information

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

ACOUSTIC CABINET FANS CVB / CVT Series

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

ACOUSTIC CABINET FANS CVAB / CVAT Series

Uniclass L7534. Manufacture controlled to ISO9001

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

MegaBox Product-specific information

CENTRIFUGAL IN-LINE FANS VENT Series

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

SILENT MV Ultra Quiet In-line Fans

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

QUBE SQU-HT(S) Product Brochure

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

MAJAX-2 GENERAL SPECIFICATION

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

DIRECT-AIR ILB / ILT Series Rectangular duct fans

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

TD-ECOWATT AND DECOR-ECOWATT Series

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

TD-SILENT Series (160 to 1000 models)

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

AXUS HIGH TEMPERATURE AXIAL FANS

ZOO FAN SDF Destratification Ceiling Mounted Fan

WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS.

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

Sapphire Horizontal Waterside Control Fan Coil Units

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

Series VTI Quiet Cased Twin Extract Fan Unit

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

Compact Design BB101 & 93

Axial fans. What s more, non-stock models are normally available within two weeks.

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Centrifugal fan with highly efficient EC drive motor

BIFURCATED AXIAL FLOW FANS

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

MULTIFLOW SEL Product Brochure

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

BESB and BESF Box fans for extraction and air supply jobs BESB - backward curved vanes BESF - forward curved vanes

MIRUVENT. Power roof ventilator with 27 different airflow variants up to 24,000 m 3 /h

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

AC Commercial Fans Edition. ErP ready

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

In-line rectangular fans. Technical Catalogue

ISEO IMF Product Brochure

Transcription:

Twin and Single Inline Fans Offers a range of flexible installation and application options, including auto-changeover on the Twin range

2 Version 3.1

Breathing Buildings Inline Box Fans Demand Control Ventilation 3 Inline Box Fans with Demand Control Ventilation Designed for energy efficient supply or extract ventilation, our range of inline fans provide full Demand control ventilation. The inline fan range maintains low noise levels and is compact enough to be discreetly installed above a false ceiling or on the roof. The Twin models offer auto-changeover functionality for toilets and other rooms where % standby is required. Product Information Features Duct Sizes mm - Airflow.1 to 1.6m 3 /s, Pressure up to 6Pa Demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc construction suitable for internal or external mounting Manufactured controlled to BS EN ISO 91 tested to BS848 Part 1 & 2 Available as single or twin fan models Twin fans incorporate duty sharing auto changeover control as standard Product Description Available as single or twin models and internally treated with O Class rated acoustic foam for high sound absorption. Weatherproof external units incorporate an additional controller shroud. The housing is designed to be as compact as possible for concealed false ceiling applications. The unit is suitable for ceiling or floor mounting, non-return dampers can be easily rotated on site to suit. Controls Hierarchical Control The system is controlled by on-board electronics, with an LCD display showing fan status and allowing for simple commissioning and installation, whether as a local sensor control unit or linked into a building management system. 1. Switched on/off or minimum/maximum level control. In an environment such as an office the system is activated and runs between minimum and maximum levels by a choice of sensors. AQS Air Quality Sensor PIR Detector Thermostat Humidistat Time Clock BMS (remote enable) 2. Hierarchical maximum demand multi-sensor input. Used with a combination of sensors, with a defined level of priorities to simultaneously control a number of atmospheric conditions within a room, such as a meeting room. CO 2 /temperature room mounted CO 2 duct mounted Manual speed adjuster Building Management System (-1V)

4 Inline Box Fans with Demand Control Ventilation Construction and Impellers All units feature a low energy, Class 1, EC/DC external rotor motor and backward curved impeller assembly specifically chosen for performance and non-overloading characteristics. The assembly is dynamically balanced to DIN ISO 194 Grade 6.3. Models with a duct size of mm are rated IP54, all other sizes are rated IP44 according to BS EN 6529. Ball bearings are greased for life. Insulation is Class B (from - C to +6 C). All models incorporate internal electronic overload protection and soft start function. Electrical Every unit is fitted with a purpose designed PCB controller with alphanumerical display and 4 button membrane keypad for fan status & commissioning set up. The enclosure is fitted with a 4-pole 1A isolator that is suitable for fitting a locking device to prevent accidental operation. The twin unit controller features automatic 6hr duty/share and run/standby in the event of motor failure. s are single phase 23V +/- 1% / /6Hz / 1ph (size -mm) or V +/- 1% / /6Hz / 3ph (size mm), (4 wire systems only). 24V DC power is provided from the controller for powering the matched range of switches and sensors. Sound Extensively tested to BS848 parts 1 & 2. Published db(a) figures are free field sound pressure levels at with spherical propagation at reference level of 2x1-5 Pa. The inlet/outlet sound power level spectra figures are db with a reference of 1 12 Watts. System Overview The system is made up of 3 parts: EC/DC Fan, Integral Control Unit, Sensors and Controls. The ventilation demands of the room are detected by the wall, ceiling or duct mounted sensors/switches. These communicate with the control unit, which in turn drives the fan to the required speed to deliver the airflow. As the ventilation is provided to the room the sensors continuously feedback to the control unit, driving the fan motor to the exact level required in the room at any one time. System Technology Demand ventilation is a closed loop controlled ventilation system. Employing a range of sensors to manage the system, demand is sensed by PIR, temperature, humidity, air quality or carbon dioxide sensors. Depending on the levels in the rooms, fan speed is ramped up or down to control

Breathing Buildings Inline Box Fans Demand Control Ventilation 5 the parameters within the required limits. If the room is unoccupied, the system switches off, saving energy and cost to the business. Available in single or twin fan configurations, with twin allowing for load sharing or standby for extra reliability. EC/DC Energy Saving Fan Technology These fans utilise the latest EC/DC motor technology, which provides energy saving benefits even over DC motors. This technology is also infinitely speed controllable and offers increased energy savings across the complete speed control range when compared with conventional inverter drive solutions. The result is higher efficiency, reduced noise, accurate controllability, better speed control drawing less power and as a result better overall system performance. The unit is designed for use in a hierarchal system where maximum demand, for example temperature and/or CO 2 gives priority control of the fan speed.

6 Inline Box Fans Demand Control Ventilation - Single MV - -IL Dimensions (mm) AIRFLOW H SPIGOT C OFFSET L C D E G A F B Weight Model A B C D E F G H kg MV-IL 3 443 275 192 36 62 8.5 MV12-IL 3 443 1 275 192 36 62 8.5 MV1-IL 3 443 1 275 192 36 62 8.5 MV-IL 435 531 33 453 287 36 6 12.5 MV-IL 435 531 33 453 287 36 35 13 MV315-IL 71 8 315 54 661 458 568 43 34 MV-IL 71 8 54 661 458 568 43 36 MV-IL 898 996 735 858 577 765 59 55

Breathing Buildings Inline Box Fans Demand Control Ventilation - Single 7 MV - -IL Accessories Model Flex connection A/V mounts Duct heater (electric) Attenuator (9mm) MV-IL FLEX AVM HTR ATT MV12-IL FLEX1 AVM HTR12 ATT12 MV1-IL FLEX1 AVM HTR1 ATT1 MV-IL FLEX AVM HTR ATT MV-IL FLEX AVM HTR ATT MV315-IL FLEX315 AVM HTR315 ATT315 MV-IL FLEX AVM HTR ATT MV-IL FLEX AVM HTR ATT Model In-room CO 2 sensor In-duct CO 2 sensor PIR MV-IL 11 Duct CO2 PIR MV12-IL 11 Duct CO2 PIR MV1-IL 11 Duct CO2 PIR MV-IL 11 Duct CO2 PIR MV-IL 11 Duct CO2 PIR MV315-IL 11 Duct CO2 PIR MV-IL 11 Duct CO2 PIR MV-IL 11 Duct CO2 PIR

8 Inline Box Fans Demand Control Ventilation - Single MV-IL Pressure (Pa) % 4 % % %.2.4.6.8.1.12.14 Air Volume (m 3 /s) phase m³/s.4 1 SFP.18 Watts.1 m³/s.7.6.4 1 SFP.29.33. Watts.2.2.2 m³/s.11.1.9.7.4 1 SFP.42.47.52.66 1.13 Watts.5.5.5.5.5 m³/s.13.12.11.9.7.5.3 1 SFP.62.68.74.9 1.16 1.6 2.53 Watts.8.8.8.8.8.8.8.8.15.5.72 63 1 1k 2k 4k 8k Breakout 44 39 35 27 24 22 23 29 17 Inlet 43 43 4 35 26 22 22 29 19 Outlet 46 4 41 35 29 23 22 3 2 Breakout 48 47 37 32 29 26 3 23 Inlet 48 52 62 54 41 34 28 3 35 Outlet 49 52 67 57 48 44 38 31 39 Breakout 55 58 56 48 42 41 38 33 31 Inlet 55 58 67 67 53 47 41 35 45 Outlet 56 59 68 68 61 56 51 42 47 Breakout 64 63 6 55 47 46 44 38 36 Inlet 57 62 68 71 58 52 47 41 48 Outlet 57 63 71 72 66 62 55 48 52

Breathing Buildings Inline Box Fans Demand Control Ventilation - Single 9 MV12-IL Pressure (Pa) % % 4 % %..5.1.15.2 Air Volume (m 3 /s) phase m³/s.5 1 SFP.14 Watts.1 m³/s.9.7.5 1 SFP.21.27.38 Watts.2.2.2 m³/s.14.13.11.9.6.2 1 SFP.35.39.47.58.83 2.2 Watts.5.5.5.5.5.4 m³/s.16.15.14.11.9.7.4 1 SFP.51.54.58.75.92 1.17 2. Watts.8.8.8.8.8.8.8.9.18.51.72 63 1 1k 2k 4k 8k Breakout 49 4 34 28 26 24 23 29 18 Inlet 46 44 41 35 27 22 22 28 2 Outlet 47 47 42 36 33 27 22 29 21 Breakout 53 49 49 39 34 28 23 29 24 Inlet 56 58 53 43 37 31 29 33 Outlet 56 58 53 43 37 31 29 37 Breakout 55 55 58 46 39 31 31 33 Inlet 54 64 68 64 55 49 43 36 44 Outlet 56 67 72 66 64 6 55 45 49 Breakout 62 58 59 57 52 46 37 33 37 Inlet 58 69 7 7 6 56 48 42 49 Outlet 58 7 71 73 7 67 6 52 54

1 Inline Box Fans Demand Control Ventilation - Single MV1-IL 7 % % % %.2.4.6.8.1.12.14.16.18 phase m³/s.5 1 SFP.14 kw.1.1 m³/s.1.8.6 1 SFP.19..35 kw.2.2.2 m³/s.15.14.12.1.6.1 1 SFP.31.34.41.51.85 4. kw.5.5.5.5.5.5 m³/s.17.16.15.12.1.7.4 1 SFP.47.51.54.68.81 1.16 2. kw.8.8.8.8.8.8.8.8.16.48.74 63 1 1k 2k 4k 8k Breakout 46 43 36 28 26 23 24 29 18 Inlet 46 45 42 37 3 24 23 29 21 Outlet 43 45 42 37 35 31 22 28 22 Breakout 4 35 28 24 29 Inlet 56 6 56 46 41 36 3 35 Outlet 51 59 61 56 53 51 46 33 38 Breakout 53 57 57 51 48 42 36 31 33 Inlet 57 65 71 66 58 52 44 42 46 Outlet 56 67 75 67 65 63 56 Breakout 62 61 59 6 54 49 43 37 39 Inlet 59 68 72 76 64 58 51 48 54 Outlet 59 7 74 76 71 7 64 58 56

Breathing Buildings Inline Box Fans Demand Control Ventilation - Single 11 MV-IL 7 % 4 % % %..5.1.15.2..3 phase 7 m³/s.6 1 SFP.13 kw.1 m³/s.14.11.8 1 SFP.19..34 kw.3.3.3 m³/s.22.2.18.13.9.4 1 SFP.37.42.46.65.88 2 kw.8.8.8.8.8.8 m³/s.28.26..21.18.14.11.7.2 1 SFP.54.61.65..93 1.2 1.54 2.41 7.75 kw.15.16.16.17.17.17.17.17.16.8.16.5.72 63 1 1k 2k 4k 8k Breakout 48 41 39 3 29 26 24 31 2 Inlet 52 49 43 34 32 24 3 26 Outlet 46 55 48 43 39 42 29 3 28 Breakout 55 53 55 42 41 37 34 32 29 Inlet 54 57 67 62 51 44 47 4 41 Outlet 55 59 67 62 58 56 55 46 44 Breakout 66 63 63 52 47 46 45 44 37 Inlet 63 66 68 77 64 57 56 53 54 Outlet 65 68 66 76 71 69 65 61 56 Breakout 63 69 66 6 53 51 42 Inlet 68 71 72 77 7 63 61 57 56 Outlet 7 72 69 76 76 72 65 62

12 Inline Box Fans Demand Control Ventilation - Single MV-IL 7 7 Sentinel Single Fan.28.24.2 % % % % 4 % % %..5.1.15.2..3..35..5.1.15.2..3.35 Phase phase m³/s m³/s.7.7 1 SFP SFP.11.11 kw kw.1.1 m³/s m³/s.15.15.11.11.7.7 1 SFP SFP.15.15.22.22.34.34 kw kw.2.2.2.2.2.2 m³/s m³/s.24.24.22.22.19.19.13.13.7.7 1 SFP SFP.26.26.3.3.36.36.52.52 1 kw kw.6.6.7.7.7.7.7.7.7.7 m³/s m³/s.33.33.3.3.28.28.24.24.19.19.15.15.9.9.1.1 1 SFP SFP.37.37.44.44.49.49.59.59.77.77.97.97 1.48 1.48 3.7 3.7 kw kw.12.12.13.13.14.14.14.14.15.15.15.15.13.13.4.4 %.16.12.8.4 Absorbed Power kw.7.7.2.2 1 1.38 1.38 63 1 1k 2k 4k 8k Breakout 42 42 37 31 29 26 31 19 Inlet 48 49 42 38 35 24 24 29 22 Outlet 47 46 41 37 41 29 24 29 24 Breakout 52 48 53 43 37 36 34 3 27 Inlet 55 57 65 58 49 43 45 38 39 Outlet 53 57 62 58 54 55 51 36 41 Breakout 54 56 57 57 48 46 45 36 36 Inlet 63 65 69 76 62 54 53 49 53 Outlet 63 66 69 72 69 68 62 55 54 Breakout 61 63 62 62 55 54 52 45 42 Inlet 68 71 72 68 62 59 56 58 Outlet 68 71 7 78 75 75 68 63 6

Breathing Buildings Inline Box Fans Demand Control Ventilation - Single 13 MV315-IL % % % %.1.2.3.4.5.6 phase m³/s.12 1 SFP.6 kw.1 m³/s.26.17.6 1 SFP.1.16.42 kw.3.3.3 m³/s.44.39.32.18 1 SFP.18.21.26.46 kw.8.8.8.8 m³/s.57.53.48.37.26.15 1 SFP.27.3.34.44.62 1.9 kw.15.16.16.16.16.16.8.19. 1.36 63 1 1k 2k 4k 8k Breakout 45 42 44 32 3 26 31 21 Inlet 47 43 4 31 28 22 23 29 19 Outlet 47 44 42 37 33 27 29 21 Breakout 54 56 48 46 36 3 26 31 27 Inlet 61 63 54 47 44 39 32 3 31 Outlet 6 63 55 55 51 49 42 31 37 Breakout 57 68 6 49 45 42 36 32 38 Inlet 62 78 67 59 55 51 45 4 44 Outlet 62 82 68 66 64 61 55 46 Breakout 62 69 69 56 53 47 43 36 44 Inlet 67 78 79 66 61 58 53 45 51 Outlet 66 78 78 73 7 68 63 55 56

14 Inline Box Fans Demand Control Ventilation - Single MV-IL 7 % % % %.1.2.3.4.5.6.7.8.9 1. phase m³/s.24 1 SFP.7 kw.2 m³/s..42.32 1 SFP.14.19. kw.7.8.8 m³/s.74.71.65.51.37.19 1 SFP.27.29.33.43.58.96 kw.2.21.21.22.21.18 m³/s.95.9.85.75.64.52.38.2 1 SFP.42.45.49.58.69.84 1.9 1.79 kw.4.41.42.44.44.44.42.36.13.59 1. 2.47 63 1 1k 2k 4k 8k Breakout 44 4 46 35 29 26 24 31 21 Inlet 48 48 39 3 23 24 3 23 Outlet 51 48 47 42 38 28 29 Breakout 56 68 54 45 41 34 26 3 33 Inlet 69 74 65 56 52 48 38 33 41 Outlet 68 72 65 62 61 57 48 39 45 Breakout 63 73 68 57 52 44 38 32 42 Inlet 74 82 78 68 64 61 56 47 53 Outlet 75 87 77 75 73 7 64 55 58 Breakout 67 73 76 63 58 44 4 48 Inlet 78 83 87 73 69 66 61 54 59 Outlet 78 85 92 79 75 69 61 65

Breathing Buildings Inline Box Fans Demand Control Ventilation - Single 15 MV-IL 7 % % % %.2.4.6.8 1 1.2 1.4 1.6 phase 7 m³/s.46.23 3 SFP.8.18 kw.4.4 m³/s.89.76.65.39 3 SFP.18.21.27.42 kw.16.16.17.16 m³/s 1.39 1.26 1.17.99.85.63.32 3 SFP.3.34.36.46.56.76 1.4 kw.41.43.42.45.47.48.45 m³/s 1.6 1.49 1.41 1.27 1.15 1.2.88.71.41 3 SFP.46.49.53.62.73.86 1.1 1.19 1.6 kw.74.73.74.79.84.88.89.85.66.21.67 1.6 2.1 63 1 1k 2k 4k 8k Breakout 57 49 43 36 42 26 33 Inlet 69 55 47 45 42 29 32 29 Outlet 68 56 53 49 39 31 32 33 Breakout 65 69 6 51 48 37 31 32 36 Inlet 7 78 67 63 53 49 42 41 45 Outlet 7 76 7 68 65 6 52 46 49 Breakout 69 78 71 61 57 49 42 42 46 Inlet 75 89 78 74 64 61 54 48 56 Outlet 76 86 83 77 71 66 59 62 Breakout 7 79 75 66 61 52 47 43 49 Inlet 77 86 83 77 68 64 58 53 58 Outlet 78 87 84 83 79 73 69 61 64

16 Inline Box Fans Demand Control Ventilation - Twin TMV - -IL Dimensions (mm) Ø C E D G A F B Model Duct diameter mm a b c d e f g Weight Kg TMV-IL 61 75 591 717 6 622 26 TMV12-IL 61 75 1 591 717 6 622 26 TMV1-IL 61 75 1 591 717 6 622 26 TMV-IL 1 896 73 83 343 734 39 TMV-IL 9 12 798 9 354 829 48 TMV315-IL 15 1353 315 1145 1272 536 1176 88 TMV-IL 15 1353 1145 1272 536 1176 9 TMV-IL 1492 159 1533 1661 675 1564 175

Breathing Buildings Inline Box Fans Demand Control Ventilation - Twin 17 TMV - -IL Accessories Model Flex connection A/V mounts Attenuator (9mm) TMV-IL FLEX AVM ATT TMV1-IL FLEX1 AVM ATT12 TMV1-IL FLEX1 AVM ATT1 TMV-IL FLEX AVM ATT TMV-IL FLEX AVM ATT TMV315-IL FLEX315 AVM ATT315 TMV-IL FLEX AVM ATT TMV-IL FLEX AVM ATT Model Temperature & CO 2 sensor Duct CO 2 sensor PIR TMV-IL 11 Duct CO2 PIR TMV1-IL 11 Duct CO2 PIR TMV1-IL 11 Duct CO2 PIR TMV-IL 11 Duct CO2 PIR TMV-IL 11 Duct CO2 PIR TMV315-IL 11 Duct CO2 PIR TMV-IL 11 Duct CO2 PIR TMV-IL 11 Duct CO2 PIR

18 Inline Box Fans Demand Control Ventilation - Twin TMV-IL 7 % % % %.2.4.6.8.1.12.14 phase m³/s.3.1 1 SFP.3.9 kw.1.1 m³/s.6.5.4 1 SFP.38.44.53 kw.2.2.2 m³/s.9.8.7.5.3.1 1 SFP.61.69.79 1.8 1.7 4.9 kw.6.6.6.5.5.5 m³/s.11.1.9.8.6.5.4 1 SFP.75.83.92 1.4 1.38 1.66 2.8 kw.8.8.8.8.8.8.8.8.16..69 63 1 1k 2k 4k 8k Breakout 45 39 35 27 23 23 3 17 Inlet 45 38 41 29 21 22 29 18 Outlet 43 39 34 28 24 22 23 28 17 Breakout 47 55 47 35 28 24 24 29 23 Inlet 48 43 37 32 28 22 28 22 Outlet 47 52 46 42 38 35 26 29 Breakout 55 64 58 45 38 35 32 32 32 Inlet 54 58 54 51 44 4 31 3 32 Outlet 51 61 59 56 49 4 34 37 Breakout 65 69 61 42 4 37 36 36 Inlet 55 63 56 53 49 45 38 34 35 Outlet 53 65 59 58 54 55 48 39 4

Breathing Buildings Inline Box Fans Demand Control Ventilation - Twin 19 TMV12-IL Guide % % % %.2.4.6.8.1.12.14 phase m³/s.4 1 SFP. kw.1 m³/s.7.6.4 1 SFP.31.37.55 kw.2.2.2 m³/s.12.1.9.7.5.2 1 SFP.45.54.61.79 1.6 2.45 kw.5.5.6.6.5.5 m³/s.13.12.11.9.8.6.3 1 SFP.63.68.75.92 1.4 1.35 2.6 kw.8.8.8.8.8.8.8.9.18.51.72 63 1 1k 2k 4k 8k Breakout 48 39 35 28 23 24 3 18 Inlet 46 41 34 27 24 21 22 29 17 Outlet 44 41 36 29 21 22 28 17 Breakout 49 56 48 35 33 3 Inlet 49 56 4 34 31 23 29 26 Outlet 49 6 56 45 4 37 27 29 3 Breakout 56 66 59 45 35 31 31 32 33 Inlet 48 6 56 51 44 4 31 3 33 Outlet 53 66 61 56 52 51 45 34 39 Breakout 59 72 64 52 41 36 35 36 39 Inlet 52 66 66 56 51 47 38 39 39 Outlet 54 69 64 61 57 57 52 43 44

2 Inline Box Fans Demand Control Ventilation - Twin TMV1-IL % % % %.2.4.6.8.1.12.14.16 phase m³/s.4 1 SFP.23 kw.1 m³/s.8.6.4 1 SFP..35.53 kw.2.2.2 m³/s.12.11.9.7.4 1 SFP.4.45.58.76 1.3 kw.5.5.5.5.5 m³/s.14.13.12.1.8.5.2 1 SFP.58.63.69.83 1.3 1.6 3.85 kw.8.8.8.8.8.8.8.8.17.48 t.71 63 1 1k 2k 4k 8k Breakout 46 4 35 27 26 23 23 29 17 Inlet 45 39 36 28 27 24 22 29 18 Outlet 47 43 36 3 26 23 22 28 21 Breakout 48 52 49 37 31 26 23 29 24 Inlet 47 55 48 41 33 3 23 29 Outlet 49 59 56 44 42 4 32 29 3 Breakout 55 58 58 49 45 41 38 32 33 Inlet 54 62 64 52 45 41 33 32 36 Outlet 55 67 66 57 53 53 47 38 41 Breakout 6 63 62 59 51 47 42 41 39 Inlet 58 66 66 59 46 39 36 4 Outlet 6 71 67 64 61 61 55 49 47

Breathing Buildings Inline Box Fans Demand Control Ventilation - Twin 21 TMV-IL 7 % % % %.5.1.15.2..3 phase 7 m³/s.5 1 SFP.2 kw.1 m³/s.11.8.6 1 SFP..35.47 kw.3.3.3 m³/s.19.17.15.11.7.4 1 SFP.42.47.54.74 1.16 2. kw.8.8.8.8.8.8 m³/s..24.23.2.17.13.1.7.4 1 SFP.64.68.72.83.98 1.29 1.69 2.39 4.3 kw.16.16.17.17.17.17.17.17.16.9.2 1.7 1.4 63 1 1k 2k 4k 8k Breakout 47 45 37 4 37 32 31 23 Inlet 44 48 36 36 32 22 29 21 Outlet 47 49 37 37 33 36 23 3 23 Breakout 52 54 54 43 38 41 26 32 29 Inlet 56 59 56 49 41 34 34 31 31 Outlet 52 61 54 53 47 46 41 33 34 Breakout 62 64 6 58 45 43 32 35 37 Inlet 55 64 59 64 54 47 42 38 42 Outlet 62 7 61 69 61 58 55 51 48 Breakout 67 69 64 63 51 45 38 4 42 Inlet 58 7 63 68 62 55 51 49 47 Outlet 68 75 65 67 67 64 6 58

22 Inline Box Fans Demand Control Ventilation - Twin TMV-IL 7 % % % %.5.1.15.2..3 phase m³/s.5 1 SFP.18 kw.1 m³/s.12.9.5 1 SFP.21.3.54 kw.3.3.3 m³/s.23.2.17.11.6 1 SFP.29.35.43.66 1.1 kw.7.7.7.7.7 m³/s.3.27..2.15.11.7.1 1 SFP.47.53.57.69.91 1.26 2.1 12.1 kw.14.14.14.14.14.14.14.12.9.2.92 1.4 63 1 1k 2k 4k 8k Breakout 45 41 34 28 26 24 31 18 Inlet 47 41 35 33 27 23 24 31 19 Outlet 45 42 36 34 32 23 3 2 Breakout 49 51 39 31 28 31 Inlet 53 51 48 41 33 29 31 29 Outlet 51 55 49 54 45 43 33 31 33 Breakout 56 59 58 51 42 36 3 32 33 Inlet 59 62 58 62 52 43 42 36 4 Outlet 58 63 59 67 6 58 53 46 46 Breakout 61 64 61 6 49 42 36 35 39 Inlet 64 68 61 69 6 47 47 Outlet 63 69 62 78 66 67 61 57 56

Breathing Buildings Inline Box Fans Demand Control Ventilation - Twin 23 TMV315-IL Guide 7 4 % % % %.5.1.15.2..3.35.4.45.5 phase m³/s.9 1 SFP.11.9 kw.1 m³/s.21.13.1 1 SFP.12.22 2.4.2 kw.3.3.2 m³/s.34.29..14 1 SFP.2.23.28.51.6 kw.7.7.7.7 m³/s.46.43.39.32.24.14 1 SFP.3.33.36.46.62 1.4 1.4 kw.14.14.14.15.15.15 63 1 1k 2k 4k 8k Breakout 48 42 37 3 27 24 3 19 Inlet 44 42 34 28 23 22 22 29 17 Outlet 47 4 35 32 27 24 23 29 18 Breakout 57 44 42 3 26 3 24 Inlet 53 53 42 4 34 28 24 3 24 Outlet 54 56 47 58 42 38 29 3 35 Breakout 61 66 55 44 37 33 27 3 32 Inlet 58 72 56 52 45 39 35 32 37 Outlet 61 79 61 6 55 53 44 4 45 Breakout 66 72 71 51 44 38 36 32 43 Inlet 63 74 65 59 52 46 43 4 42 Outlet 66 76 68 69 63 61 53 45 49

24 Inline Box Fans Demand Control Ventilation - Twin TMV-IL 7 % % % %.1.2.3.4.5.6.7.8.9 phase m³/s.16 1 SFP.13 kw.2 m³/s.44.34.21 1 SFP.16.21.34 kw.7.7.7 m³/s.69.6.54.43.27.1 1 SFP.31.35.39..73 1.81 kw.21.21.21.22.2.18 m³/s..73.68.59..4.27.1 1 SFP.49.53.56.63.73.93 1.46 3.93 kw.39.39.38.37.36.37.39.39.19.77 2.2 2.86 63 1 1k 2k 4k 8k Breakout 56 41 41 31 27 24 31 2 Inlet 46 44 41 35 27 22 23 29 2 Outlet 48 45 41 38 32 24 24 29 21 Breakout 65 62 55 44 38 31 26 3 3 Inlet 6 66 55 46 38 3 31 33 Outlet 64 67 59 57 53 48 41 35 39 Breakout 74 75 68 56 49 43 38 4 42 Inlet 69 67 62 57 45 41 46 Outlet 72 81 72 71 66 62 55 48 52 Breakout 78 77 75 61 55 48 46 41 48 Inlet 73 82 73 66 62 53 45 Outlet 75 85 78 77 73 69 63 55 58

Breathing Buildings Inline Box Fans Demand Control Ventilation - Twin TMV-IL 7 % % % %.2.4.6.8 1 1.2 1.4 phase m³/s.35.12 3 SFP.13.37 kw.5.4 m³/s.7.59.48.21 3 SFP.22.28.35.7 kw.16.16.17.15 m³/s 1.14 1.7 1..83.65.48.23 3 SFP.35.38.43.53.68 1. 1.77 kw.4.41.43.44.44.48.41 m³/s 1.34 1.26 1.19 1.4.9.75.59.39 3 SFP.45..54.64.76.93 1.21 1.82 kw.6.63.64.67.68.7.71.71.39.67 1.6 2.1 63 1 1k 2k 4k 8k Breakout 59 45 45 34 29 24 3 22 Inlet 49 45 43 38 33 23 24 31 22 Outlet 48 42 45 42 37 27 31 24 Breakout 66 64 54 48 39 32 26 32 32 Inlet 6 63 58 54 45 4 35 4 35 Outlet 66 6 64 6 54 51 39 41 41 Breakout 72 75 66 59 43 37 4 42 Inlet 67 75 7 65 57 51 47 46 Outlet 75 74 76 73 66 61 53 51 53 Breakout 74 79 69 62 54 46 4 41 46 Inlet 69 74 7 61 55 51 51 Outlet 78 78 82 78 7 65 6 54 58

Contact us: w: www.breathingbuildings.com e: info@breathingbuildings.com t: 1223 46 f: 1223 461 a: 15 Sturton Street Cambridge CB1 2SN skype: twitter: breathingbuildings @breathingbuild @natventnews