Margaret M. Alkek Building for Biomedical Research Baylor College of Medicine. Appendix A Runaround Loop Component Information

Similar documents
ADVANCE. 2 Pole Impeller PUMPS PUMPS

Submersible Turbine Pumps

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

Appendix A. Cooling Coil

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

FCVC Series VERTICAL FAN COILS

Fluid Coils. Desaturation Coils. Hot Water Coils

Fluid Coils. Desaturation Coils. Hot Water Coils

2015 A Series Catalog

SARAVEL MINI AIR-HANDLING UNIT

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

Nomenclature. Nomenclature Distributing coil types

Consider The Possibilities...

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

LK-FCTB August 2010 (Replaces LK-FCTB,April 2007) FPO. Direct Drive Fluid Coolers Technical Guide. Models PFG & RF6

Air-Cooled Fluid Cooler

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

Prepared By : Checked By : Approved By : Page 1 out of 6

SOLUTION AIR HANDLING UNIT PERFORMANCE SPECIFICATION

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

Complete HVAC Capability

Contents and Nomenclature

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

5 to 100 Ton Capacity Custom Capacities Available

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Commercial Blower Coil Air Handlers

CAT PAU 99(2) SUPERSEDES CAT.NO SARAVEL PACKAGED AIR CONDITIONING UNITS

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

Nomenclature. Contents. Air Handling Unit SR AH 250 LP HS

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

DPS. The SSV Dual Pump System

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

EQUIPMENT TECHNICAL SUBMITTAL FOR APPROVAL DATE SUBMITTED APPROVED AS NOTED: NOT APPROVED PLEASE RESUBMIT

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

Steam Coils. Connections. Vents & Drains. Standard on all coils

D Series. Centrifugal Pumps. Pump End Kits. Features: PAGE: CP-435 DATE: June 5, 2006

JE1, JE1 4 SERIES CONTENTS: Stainless Steel Construction Closed impeller Flow: 8 to 95 GPM Head: to 144 ft. Range of HP: to 3 HP

High Performance Fan Coils FCHG Genesis Series Horizontal

VAHU Vertical Air Handling Unit

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

Engineers Without Borders

INSTRUCTIONS. complete drawings to: or Fax to: (610)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

Dolan Mechanical, Inc. 638 Johnson Road, PO Box 326 Sicklerville, NJ (856) FAX (856) NO EXCEPTION TAKEN

FDCLP2 Constant Volume Series Flow, Low Profile

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

WATER SOURCE HEAT PUMPS

dppumps-usa.com Excellence in Multistage Vertical Pumps Represented exclusively in North America by:

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

CDU. Model CDU Contents. EBARA Stainless Steel Centrifugal Pumps

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

System One Pumps Selecting Centrifugal Pumps S1-201

Series. NV Vertical Multistage Booster Pump

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1442 Page 1442.

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

C O I L M A S T E R CMC-110

Fan Powered Terminal Units FPV, FDV Series Variable Volume Parallel Flow

GENERAL ELECTRIC FAN COIL UNITS

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

LIST PRICES WAC AIR CURTAINS

Product Data. S Single-stage scroll compressor S Multi-speed constant torque blower motor Control

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

BAC, BAF, BAH Central Station Air Handlers

Address: VTS Clima L.L.C.

FCX TECHNICAL BOOKLET

WE MAKE INDOOR AIR BETTER

Submittal. Front View Side View

BSM ROTARY GEAR PUMPS

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

The World Leading Air-conditioning Company

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Remote Air Cooled Condenser

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

Waterfall Pumps Manufacturing

RBV Engineering Guide

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

Basic Hydraulic Features. Basic Mechanical Features

BHH Product Specifications

EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating.

Product Data. Features/Benefits. 36CBAC,AE,AF,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

HCH6. Product Specifications

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

PHCD-Series. Catalog

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

Transcription:

Justin Mulhollan Spring 06 Mechanical Option Margaret M. Alkek Building for Biomedical Research Baylor College of Medicine Houston, TX Appendix A Runaround Loop Component Information 47

Pump Data Sheet - MEPCO PSU Name: Justin Date: 3/30/06 Pump: Size: RP06-15 Type: IN-LINE Synch speed: 30 rpm Curve: PC1147 Speed: 30 rpm Dia: 5.25 in Impeller: Specific Speeds: Ns: --- Nss: --- Dimensions: Suction: 1.5 in Discharge: 1.5 in Search Criteria: Flow: 51 US gpm Head: 92.5 ft Near miss: 5 % of Head Fluid: Water Temperature: F Density: 62.25 lb/ft³ Vapor pressure: 0.2563 psi a Viscosity: 1.5 cp Atm pressure: 14.7 psi a NPSHa: ft Pump Limits: Temperature: --- F Pressure: --- psi g Sphere size: --- in Power: --- hp Eye area: --- in² Motor: Standard: NEMA Enclosure: TEFC Sizing criteria: Max Power on Design Curve Size: 3 hp Speed: 30 Frame: 182T Flow: Head: ---- Data Point ---- 51 US gpm 93 ft Eff: 57% Power: NPSHr: 2.05 hp 6.25 ft ---- Design Curve ---- Shutoff head: Shutoff dp: Min flow: BEP: 116 ft.3 psi --- US gpm % @ 61.1 US gpm NOL power: 2.38 hp @ 78 US gpm 1 125 75 6 in 5.25 in 4.5 in 55 55 55 55 -- Max Curve -- Max power: 3.36 hp @ 84 US gpm 25 0 30 30 70 90 1 1 0 4 30 70 90 1 1 2 0 30 70 US gpm 90 1 1 Performance Evaluation: Flow Speed Head Efficiency Power NPSHr US gpm rpm ft % hp ft 61.2 30 85.6 2.2 7.93 51 30 93 57 2.05 6.25.8 30 54 1.89 4.59 30.6 30 6 48 1.7 3.33.4 30 1 38 1.53 2.99 Selected from catalog: Mepco Pumps. Vers: 1

Heatcraft CERTIFIED DRAWING Customer: Date: 3/29/06 Job: Return MODEL NUMBER ITEM QTY TYPE FPI ROWS FIN FH (IN) FL (IN) HAND Supply 1 5WS 08 06 A 30.00.00 Universal MATERIALS OF CONSTRUCTION OPTIONS Fins.0075 Aluminum Casing Type Flanged Label Kit No Tubes.0 Copper Vent/Drain. FPT on End Cap Corrosion Resistant Yes Casing Galvanized Steel Mounting Holes No Connection 2 MPT Carbon Steel Turbospirals No Drain Headers No Vent/Drain Location DIMENSIONAL DATA (IN) CONNECTION FLANGES SIZE A B C D E F H I J L M N R S T W 2 1.753 1.75 2.51 4.76 2.51 4.76 33.00 87. 3.00 83.00 5.00 2. 1. 1. 1..00 Notes: 1. All dimensions are in inches. 2. One intermediate tube support fabricated from heavy gauge stock of the same material as the fins will be provided. 3. Cap all unused connections. 4. The supply line should be connected to the lower connection on the leaving air side for counterflow operation. 5. Coils will vent and drain through factory-installed vent and drain fittings when mounted level for horizontal flow. GENERAL NOTES 6. Connection location other than standard could affect vent and drain locations. Consult factory. Copyright 03 Outokumpu Heatcraft Confidential and Proprietary. This design is for the exclusive and confidential use of Outokumpu Heatcraft and its client. Any duplication Page 1

Heatcraft CERTIFIED DRAWING Customer: Date: 3/29/06 Job: Return MODEL NUMBER ITEM QTY TYPE FPI ROWS FIN FH (IN) FL (IN) HAND Exhaust 1 5WS 08 06 A 30.00.00 Universal MATERIALS OF CONSTRUCTION OPTIONS Fins.0075 Aluminum Casing Type Flanged Label Kit No Tubes.0 Copper Vent/Drain. FPT on End Cap Corrosion Resistant Yes Casing Galvanized Steel Mounting Holes No Connection 2 MPT Carbon Steel Turbospirals No Drain Headers No Vent/Drain Location DIMENSIONAL DATA (IN) CONNECTION FLANGES SIZE A B C D E F H I J L M N R S T W 2 1.753 1.75 2.51 4.76 2.51 4.76 33.00 87. 3.00 83.00 5.00 2. 1. 1. 1..00 Notes: 1. All dimensions are in inches. 2. One intermediate tube support fabricated from heavy gauge stock of the same material as the fins will be provided. 3. Cap all unused connections. 4. The supply line should be connected to the lower connection on the leaving air side for counterflow operation. 5. Coils will vent and drain through factory-installed vent and drain fittings when mounted level for horizontal flow. GENERAL NOTES 6. Connection location other than standard could affect vent and drain locations. Consult factory. Copyright 03 Outokumpu Heatcraft Confidential and Proprietary. This design is for the exclusive and confidential use of Outokumpu Heatcraft and its client. Any duplication Page 2

Heatcraft DIMENSIONS SCHEDULE Customer: Date: 3/29/06 Job: Return CP 63same_end_universal Item Qty Model FH x FL Hand Conn Size A B C D E F H I J L M N R S T W Supply 1 5WS06A 30.00x.00 U 2.00 1.75 1.75 2.51 4.76 2.51 4.76 33.00 87. 3.00 83.00 5.00 2. 1. 1. 1..00 Exhaust 1 5WS06A 30.00x.00 U 2.00 1.75 1.75 2.51 4.76 2.51 4.76 33.00 87. 3.00 83.00 5.00 2. 1. 1. 1..00 Copyright 03 Outokumpu Heatcraft Confidential and Proprietary. This design is for the exclusive and confidential use of Outokumpu Heatcraft and its client. Any duplication made for the purpose of disclosing this design or any part of the design to a competitor of Outokumpu Heatcraft is in direct violation of this confidentiality. Any duplication must Page 3

Heatcraft FLUID RUN AROUND Customer: Date: 3/29/06 Job: Return Season: Winter Three Way Valve Required: No SUPPLY EXHAUST 62.5 37.9 62.5 37.9 UOM SUPPLY COIL EXHAUST COIL Item Supply Exhaust Coils per Bank 3 3 Allow Opposite End No No Tube OD 5/8 5/8 Coil Duty Heat-Return Bend Cool-Standard Fins Per Inch 8 8 Rows 6 6 Circuiting Single Single Fin Surface A A Fin Height x Finned Length IN 30.00 x.00 30.00 x.00 Turbospirals No No Tube wall thickness & Material 0.0 Copper 0.0 Copper Fin thickness & Material 0.0075 Aluminum 0.0075 Aluminum Connection Quantity & Size IN (1) 2 (1) 2 Fluid Type Ethylene Ethylene Percent Glycol 30 30 Entering Fluid Temp. F 62.46 37.93 Fluid Flow Rate GPM 51.00 51.00 Altitude FT.00.00 Air Flow Rate SCFM/SCFM 95,000.00 95,000.00 Face Velocity FPM 1,900.00 1,900.00 Entering Air Temp. DB / WB F.00 / N/A 75.00 / 63.94 Model Number 5WS06A 5WS06A Total / Sensible Capacity MBH 573.48 / N/A 572.81 / 497. Leaving Air Temp. DB / WB F 25.57 / N/A 70.21 / 62.06 Air Pressure Drop IN WG 3. 3. Leaving Fluid Temp. F 37.91 62.46 Fluid Pressure Drop FT H.98.99 Fluid Flow Rate GPM 51.00 51.00 Fluid Velocity FPS.92.92 Weight - (Dry) / (w/fluid) LB 302.16 / 432.44 302.16 / 432.47 Notes BCEL BEL B) Rated In Compliance With ARI 4. C) Coil Not Within Certified ARI Directory. E) Specified Condition(s) Out Of ARI Range. L) Coil rating valid for Heatcraft coils only. Copyright 03 Outokumpu Heatcraft Confidential and Proprietary. This design is for the exclusive and confidential use of Outokumpu Heatcraft and its client. Any duplication Page 1

Pump Data Sheet - MEPCO PSU Name: Justin Date: 3/30/06 Pump: Size: RB06-15 Type: BASE-MOUNTED Synch speed: 30 rpm Curve: PC13 Speed: 30 rpm Dia: 5 in Impeller: Specific Speeds: Ns: --- Nss: --- Dimensions: Suction: 2 in Discharge: 1.5 in Search Criteria: Flow: 85 US gpm Head: 92.5 ft Near miss: 5 % of Head Fluid: Water Temperature: F Density: 62.25 lb/ft³ Vapor pressure: 0.2563 psi a Viscosity: 1.5 cp Atm pressure: 14.7 psi a NPSHa: ft Pump Limits: Temperature: --- F Pressure: --- psi g Sphere size: --- in Power: --- hp Eye area: --- in² Motor: Standard: NEMA Enclosure: TEFC Sizing criteria: Max Power on Design Curve Size: 5 hp Speed: 30 Frame: 184T Flow: Head: ---- Data Point ---- 85 US gpm 95.5 ft Eff: 63% Power: NPSHr: 3.25 hp 6.71 ft ---- Design Curve ---- Shutoff head: Shutoff dp: Min flow: BEP: 5 ft 45.2 psi --- US gpm 67% @ 119 US gpm NOL power: 3.9 hp @ 146 US gpm -- Max Curve -- Max power: 8.93 hp @ 2 US gpm 0 175 1 125 75 25 6.25 in 5 in 4.5 in 65 67 1 68 1 70 71 1 1 70 0 68 65 2 0 1 1 1 1 0 2 5 0 1 US gpm 1 1 1 0 2 Performance Evaluation: Flow Speed Head Efficiency Power NPSHr US gpm rpm ft % hp ft 2 30 90.6 65 3.54 8.09 85 30 95.5 63 3.25 6.71 68 30 98.8 57 2.95 5.53 51 30 1 49 2.65 4.6 34 30 2 38 2.35 3.92 Selected from catalog: Mepco Pumps. Vers: 1

Notes: Heatcraft CERTIFIED DRAWING Customer: BCM Date: 3/29/06 Job: Thesis Return MODEL NUMBER ITEM QTY TYPE FPI ROWS FIN FH (IN) FL (IN) HAND Supply 1 5WS 08 06 A 30.00.00 Universal MATERIALS OF CONSTRUCTION OPTIONS Fins.0075 Aluminum Casing Type Flanged Label Kit No Tubes.0 Copper Vent/Drain. FPT on End Cap Corrosion Resistant Yes Casing Galvanized Steel Mounting Holes No Connection 2.000 MPT Carbon Steel Turbospirals No Drain Headers No Vent/Drain Location DIMENSIONAL DATA (IN) CONNECTION FLANGES SIZE A B C D E F H I J L M N R S T W 2.00 1.753 1.75 2.51 4.76 2.51 4.76 33.00 67. 3.00 63.00 5.00 2. 1. 1. 1..00 1. All dimensions are in inches. 2. Corrosion Resistant coated coils require a longer lead-time since they must be re-tested after coating. 3. One intermediate tube support fabricated from heavy gauge stock of the same material as the fins will be provided. 4. Cap all unused connections. 5. The supply line should be connected to the lower connection on the leaving air side for counterflow operation. GENERAL NOTES 6. Coils will vent and drain through factory-installed vent and drain fittings when mounted level for horizontal flow. 7. Connection location other than standard could affect vent and drain locations. Consult factory. Copyright 03 Outokumpu Heatcraft Confidential and Proprietary. This design is for the exclusive and confidential use of Outokumpu Heatcraft and its client. Any duplication Page 1

Heatcraft CERTIFIED DRAWING Customer: BCM Date: 3/29/06 Job: Thesis Return MODEL NUMBER ITEM QTY TYPE FPI ROWS FIN FH (IN) FL (IN) HAND Exhaust 1 5WS 08 06 A 30.00.00 Universal MATERIALS OF CONSTRUCTION OPTIONS Fins.0075 Aluminum Casing Type Flanged Label Kit No Tubes.0 Copper Vent/Drain. FPT on End Cap Corrosion Resistant Yes Casing Galvanized Steel Mounting Holes No Connection 2 MPT Carbon Steel Turbospirals No Drain Headers No Vent/Drain Location DIMENSIONAL DATA (IN) CONNECTION FLANGES SIZE A B C D E F H I J L M N R S T W 2 1.753 1.75 2.51 4.76 2.51 4.76 33.00 67. 3.00 63.00 5.00 2. 1. 1. 1..00 Notes: 1. All dimensions are in inches. 2. One intermediate tube support fabricated from heavy gauge stock of the same material as the fins will be provided. 3. Cap all unused connections. 4. The supply line should be connected to the lower connection on the leaving air side for counterflow operation. 5. Coils will vent and drain through factory-installed vent and drain fittings when mounted level for horizontal flow. GENERAL NOTES 6. Connection location other than standard could affect vent and drain locations. Consult factory. Copyright 03 Outokumpu Heatcraft Confidential and Proprietary. This design is for the exclusive and confidential use of Outokumpu Heatcraft and its client. Any duplication Page 2

Heatcraft DIMENSIONS SCHEDULE Customer: BCM Date: 3/29/06 Job: Thesis Return CP 63same_end_universal Item Qty Model FH x FL Hand Conn Size A B C D E F H I J L M N R S T W Supply 1 5WS06A 30.00x.00 U 2.00 1.75 1.75 2.51 4.76 2.51 4.76 33.00 67. 3.00 63.00 5.00 2. 1. 1. 1..00 Exhaust 1 5WS06A 30.00x.00 U 2.00 1.75 1.75 2.51 4.76 2.51 4.76 33.00 67. 3.00 63.00 5.00 2. 1. 1. 1..00 Copyright 03 Outokumpu Heatcraft Confidential and Proprietary. This design is for the exclusive and confidential use of Outokumpu Heatcraft and its client. Any duplication made for the purpose of disclosing this design or any part of the design to a competitor of Outokumpu Heatcraft is in direct violation of this confidentiality. Any duplication must Page 3

Heatcraft FLUID RUN AROUND Customer: BCM Date: 3/29/06 Job: Thesis Return Season: Winter Three Way Valve Required: No SUPPLY EXHAUST 64.1 37.6 64.1 37.6 UOM SUPPLY COIL EXHAUST COIL Item Supply Exhaust Coils per Bank 3 3 Allow Opposite End No No Tube OD 5/8 5/8 Coil Duty Heat-Return Bend Cool-Standard Fins Per Inch 8 8 Rows 6 6 Circuiting Single Single Fin Surface A A Fin Height x Finned Length IN 30.00 x.00 30.00 x.00 Turbospirals No No Tube wall thickness & Material 0.0 Copper 0.0 Copper Fin thickness & Material 0.0075 Aluminum 0.0075 Aluminum Connection Quantity & Size IN (1) 2 (1) 2 Fluid Type Ethylene Ethylene Percent Glycol 30 30 Entering Fluid Temp. F 64.12 37. Fluid Flow Rate GPM 85.00 85.00 Altitude FT.00.00 Air Flow Rate SCFM/SCFM 163,000.00 163,000.00 Face Velocity FPM 3,2.00 3,2.00 Entering Air Temp. DB / WB F.00 / N/A 76.00 / 64.79 Model Number 5WS06A 5WS06A Total / Sensible Capacity MBH 1,031.82 / N/A 1,032.04 / 882.79 Leaving Air Temp. DB / WB F 25.84 / N/A 71.05 / 62.85 Air Pressure Drop IN WG 7.71 7.71 Leaving Fluid Temp. F 37.62 64.12 Fluid Pressure Drop FT H 2.44 2.47 Fluid Flow Rate GPM 85.00 85.00 Fluid Velocity FPS 1.54 1.54 Weight - (Dry) / (w/fluid) LB 302.16 / 432.42 302.16 / 432.46 Notes BCEL BEL B) Rated In Compliance With ARI 4. C) Coil Not Within Certified ARI Directory. E) Specified Condition(s) Out Of ARI Range. L) Coil rating valid for Heatcraft coils only. Copyright 03 Outokumpu Heatcraft Confidential and Proprietary. This design is for the exclusive and confidential use of Outokumpu Heatcraft and its client. Any duplication Page 1