Pulsar Evolution 2200/3000/3000 XL

Similar documents
Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

Pulsar EXtreme CLA 1500C

Pulsar EXtreme 2200C / 3200C

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual FR/AA - Page 1

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

Installation and user manual. Tower models 5P 750 5P P P 850G 5P 1550G

5P 650 AU 5P 650i R 5P 850 AU 5P 850i R 5P 1150 AU 5P 1150i R 5P 1550 AU 5P 1550i R. User's guide

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

5P 1500 RT 5P 2200 RT 5P P 3000 RT 5P Installation and user manual ENGLISH. Copyright 2012 EATON All rights reserved.

Eclipse Plus VA UPS and Surge Suppressor User s Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

3000VA 120/208/230VAC

Powerware Vdc Extended Battery Cabinet User s Guide.

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Uninterruptible Power Supply

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

General Precautions. Personnel Precautions

HPE T750 G5 UPS, T1000 G5 UPS, and T1500 G5 UPS User Guide

Liebert GXT MT+ User Manual VA Installer/User Guide

User Manual V1.0 MaxiFlex 3000

USER MANUAL. Uninterruptible power supply MODEL: 53965,

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Foreword

PR1000ELCD / PR1500ELCD User s Manual

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

POWERWARE User s Guide VA.

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Uninterruptible Power System

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

3 Uninterruptible Power Systems

Pulsar TM EX10Rack / EX15Rack EXB10Rack

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

USER MANUAL ONLINE UPS

HP 1U UPS User Guide. Abstract. Part Number: November 17, 2014 Edition: 1

Informer Compact Series

USER MANUAL DN / DN

Cruising Charger Series OWNER S MANUAL

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

User Manual Rittal PMC UPS 6kVA

XPRT 6kVA & 10kVA Online UPS

USER MANUAL MPS 1-5KW SERIES

SAVE THESE INSTRUCTIONS

Uninterruptible Power System

Extended Battery Cabinet for Nfinity

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

3 Uninterruptible Power Systems

1. Important Safety Warning

HP R/T3000 G4 and HP R/T2200 G4 UPS User Guide

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

User manual Digital Energy Uninterruptible Power Supply GT Series UPS 6-10 kva

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

OPERATING INSTRUCTION UPS PROTECT A. PROTECT A PROTECT A. 1400

Battery Unit BHM60PC/BHM100PC Instruction Manual

USER MANUAL English / Español

Intelligent Charging System Series

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

Liebert PSA VA. Installer/User Guide

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

Liebert PowerSure PSI

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

1. INTRODUCTION. Features:

User Manual / Manuel utilisateur

User Manual. Hybrid PV Inverter. Version: 2.1

User Manual 1KVA-5KVA INVERTER / CHARGER

CP900EPFCLCD User s Manual K

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

User Manual. PF0.9 6K/10K Online UPS

Liebert PowerSure PSI UPS

Back-UPS CS Back-UPS CS 350

OPERATIONAL MANUAL .TYPE - ONLINE UNINTTERRUPTIBLE POWER SUPPLY

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

Electrical Installation

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

Transcription:

www.mgeups.com Pulsar Evolution 2200/3000/3000 XL Installation and user manual

MGE UPS Systems 1660 Scenic Avenue Costa Mesa, CA 92626 (714) 557-1636 For service call 1-800-438-7373 www.mgeups.com IMPORTANT SAFETY INSTRUCTIONS Read before installing product SAVE THESE INSTRUCTIONS. This manual contains important instructions for 89347, 89348, and 89349 that should be followed during installation and maintenance of the UPS and batteries. Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar Evolution range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the environmental impact of its products. Measures that have made Pulsar Evolution a reference in environmental protection include: The eco-design approach used in product development, recycling of Pulsar Evolution at the end of its service life. To discover the entire range of MGE UPS SYSTEMS products and the options available for the Pulsar Evolution range, we invite you to visit our web site at www.mgeups.com or contact your MGE UPS SYSTEMS representative. This manual contains important instructions for Pulsar Evolution Models that must be followed during installation, operation and maintenance of the UPS and batteries. The Pulsar Evolution UPS Models that are covered in this manual are listed below. Pulsar Evolution 2200, 3000, 3000XL The normal battery voltage for all models is as follows: Pulsar Evolution 2200-72V, 3000-72V The Pulsar Evolution UPS is intended for installation in a temperature within 0 to 40º C, free of conductive contaminant s. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Page 2-3400723100/AD

Introduction CAUTION: Safety of persons The UPS has its own internal power source (the battery). Consequently, the power outlets may be energized even if the UPS is disconnected from the AC-power source. Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. The UPS must be properly earthed. Measurements are required to ensure that the total leakage current of the UPS and the protected equipment does not exceed 3.5 ma by checking their characteristics (maximum leakage current of the UPS = 2 ma). The battery supplied with the UPS contains small amounts of toxic materials. To avoid accidents, the directives listed below must be observed: - Never burn the battery (risk of explosion). - Do not attempt to open the battery (the electrolyte is dangerous for the eyes and skin). - Comply with all applicable regulations for the disposal of the battery. - Batteries constitute a danger (electrical shock, burns). The short-circuit current may be very high. Precautions must be taken for all handling: remove watches, rings, bracelets and any other metal objects, use tools with insulated handles. - Do not lay tools or metal parts on top of batteries. CAUTION: Product safety The UPS connection instructions and operation described in the manual must be followed in the indicated order. UPS must be connected to a nearby wall outlet that is easily accessible. The UPS can be disconnected from the AC-power source by removing the power cord. Check that the indications on the rating plate correspond to your AC-power system and to the actual electrical consumption of all the equipment to be connected to the UPS. Never install the UPS near liquids or in an excessively damp environment. Never let a foreign body penetrate inside the UPS. Never block the ventilation grates of the UPS. Never expose the UPS to direct sunlight or source of heat. If the UPS must be stored prior to installation, storage must be in a dry place. The admissible storage temperature range is -25ºC to +55ºC. Special precautions All handling operations will require at least two people (unpacking, installation in rack system). Once installed and connected to the AC power source for the first time, the battery will start to charge. Full charging to obtain the rated battery backup time requires at least 8 hours. Before and after the installation, if the UPS remains de-energized for a long period, the UPS must be energized for a period of 24 hours, at least once every 6 months (for a normal storage temperature less than 25 C). This charges the battery, thus avoiding possible irreversible damage. During the replacement of the battery module, it is imperative to use the same type and number of element previously mounted in the UPS, in order to maintain an identical level of performance and safety. In case of doubt, don t hesitate to contact our after sales department (for more information, refer to the web site www.mgeups.com). 3400723100/AD - Page 3

Foreword Using this document Information may be found in two ways, using: the contents; the index. Pictograms IMPORTANT: Important instructions that must always be followed. NOTE: Information, advice, help. WARNING: Indicates present eminent danger, precautionary action required. CAUTION: Indicates to proceed with caution, precautionary action required. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Page 4-3400723100/AD

Contents 1. Presentation 1.1 Overall view... 7 Tower position...7 Rack position...7 1.2 Back... 8 1.3 Control panel...9 2. Installation 2.1 Unpacking and parts check...10 2.2 Upright installation (tower position)...11 2.3 Flat installation (rack position)...12 2.4 Connecting the protected equipment...13 2.5 Connection to the RS232 or USB communications port (optional)...14 2.6 Connection to the data-line protection port (optional)...14 2.7 Installation of the communications-card option...15 3. Operation 3.1 Start-up...16 3.2 Shift to booster or fader mode (during voltage variations in the AC-input power)...16 3.3 Operation on battery power (following failure of AC-input power)...17 Transfer to battery power...17 Threshold for the low-battery warning...17 3.4 Personalization (optional)...18 Function...18 ON / OFF conditions tab...18 Battery tab...18 Voltage-thresholds tab...19 Sensitivity tab...19 4. Maintenance 4.1 Trouble-shooting...20 4.2 Replacement of the battery module...21 5. Environment...23 3400723100/AD - Page 5

Contents 6. Appendices 6.1 Technical data...24 Simplified diagram...24 Technical characteristics...25 Examples of battery backup times...26 6.2 Glossary...27 6.3 Index...28 Page 6-3400723100/AD

1. Presentation 1.1 Overall view Tower position Evolution 2200 Dimensions in inches (W x H x D) Evolution 3000 17.24 (19") x 3.56 (2U) x 25.2 Evolution 3000 XL Weight in lbs Evolution 2200 75 Evolution 3000 82 Evolution 3000 XL 46 P U L S A R Evolution 3 0 0 0 Rack position D H P U L S A R Evolution 3 0 0 0 W 3400723100/AD - Page 7

RS232 TO BATTERY CABINET RS232 TO BATTERY CABINET Pb 3 battery cabinets max 72Vdc, 7Ah Pb 3 battery cabinets max for 3000 12 battery cabinets max for 3000XL Only for 3000 72Vdc, 9Ah BATTERY CONNECTOR Volt: 72Vdc 40A U.S. PAT. No. 6,094,363 BATTERY CONNECTOR Volt: 72Vdc 40A U.S. PAT. No. 6,094,363 AC Input AC Output Volt 120V~1O Amps 16A MAX Hertz 50/60 Hz Volt 120V~1O Hertz 50/60 Hz W/VA 1540W/1920VA AC Input AC Output Volt 120V~1O Amps 24A MAX Hertz 50/60 Hz Volt 120V~1O Hertz 50/60 Hz W/VA 2000W/2800VA for 3000 2000W/2568VA for 3000 XL AC Output AC Output 5-30P R 34Z5 U.P.S. R 34Z5 U.P.S. 1. Presentation 1.2 Back Pulsar Evolution 2200 SITE WIRING FAULT 344-50282-00 Data line protection IN OUT WARNING Programmable 2 Programmable 1 1 2 5-20P AC Input 1 2 3 USB communications port. RS232 communications port. Connector for automatic detection of an additional battery module. 1 2 3 5 4 6 8 9 10 Pulsar Evolution 3000 / 3000 XL 4 5 6 Data-line protection. Slot for communications-card option. Connector for an additional battery module. 7 Output circuit breakers. Data line protection SITE WIRING FAULT 344-50297-00 IN OUT WARNING 1/2 B A AC OUTPUT BRANCH PROTECTOR (15Amp max/plug) Programmable 2 Programmable 1 1 2 B A L5-30 AC Input 8 9 Six receptacles for direct connection of protected equipment. Two programmable receptacles (1 and 2). 1 2 3 5 4 6 7 8 9 10 EXB additional battery module 11 3 11 13 10 11 12 13 Input power cords for connection to AC-power source; 2200/5-20P and 3000/L5-30. Battery module connectors (to the UPS or to other battery modules). Connectors for automatic detection of additional battery modules. Circuit breaker for battery ON/OFF and protection. Page 8-3400723100/AD

1. Presentation 1.3 Control panel 15 Illuminated ON/OFF button for the receptacles. 16 17 Operation on battery power. UPS fault. 1 2 18 19 20 21 Battery fault. Overload. Group 1 programmable receptacles supplied with power. Group 2 programmable receptacles supplied with power. Booster or fader mode. % % 22 Bar graph indicating percent load at output. 23 Bar graph indicating the battery charge level. 76 to 100%. 51 to 75%. 26 to 50%. 0 to 25%. 3400723100/AD - Page 9

2. Installation 2.1 Unpacking and parts check 26 25 27 28 29 30 P U L S A R Evolution 3 0 0 0 31 32 26 27 28 29 RS232 communications cable for Windows Operating Systems. For UNIX/Linux Operating Systems, please order, for free, the following part number: 66090 USB communications cable. Telescopic rails for mounting in 19" bay with mounting hardware. Two securing systems for equipment power cords. 30 CD-ROM with the Solution-Pac and UPS Driver software. 31 32 Product documentation. Two supports for the upright position. Page 10-3400723100/AD

2.2 Upright installation (tower position) Connect the two supports for the upright position. 2. Installation P U L S A R Evolution 3 0 0 0 P U L S A R Evolution 3 0 0 0 3400723100/AD - Page 11

P U L S A R Evolution 3 0 0 0

R 2.4 Connecting the protected equipment 2. Installation CAUTION: Check that the indications on the rating plate on the back of the UPS correspond to your AC-power system and to the actual electrical consumption of all the equipment to be connected to the UPS. U.S. PAT. No. 6,094,363 BATTERY CONNECTOR Volt: 72Vdc 40A 1 - Remove the power cord supplying the equipment to be protected. - Pulsar Evolution 2200/3000/3000 XL: Connect the supplied input power cord 10 to the AC power wall receptacle. AC Output AC Output AC Input Volt 120V~1O Amps 16A MAX Hertz 50/60 Hz Volt 120V~1O Hertz 50/60 Hz W/VA 1540W/1920VA Programmable 2 Programmable 1 1 2 AC Input 34Z5 U.P.S. 360 Rotation Plug 9 8 29 2 - Connect the protected equipment to the UPS using the rotation power cord 25. It is advised to connect priority loads to the four standard receptacles 8 and any nonpriority loads to the two programmable receptacles 9. If the UPS is connected to a computer running MGE communications software, it is possible to program the interruption of power to the programmable receptacles 9 during operation on battery power, thus reserving backup power for the priority loads. 25 10 3 - Lock the connections using the securing system 29. As soon as the UPS is energized, the battery begins charging. Eight hours are required to charge to the full rated backup time. NOTE: Pulsar Evolution 3000 XL: At least one EXB additional battery module must be connected to the UPS because it does not have internal batteries. See the EXB battery-module installation manual (Doc. no. 3400711600) for information on making the connections. 3400723100/AD - Page 13

Pb Pb 2. Installation 2.5 Connection to the RS232 or USB communications port (optional) TO BATTERY CABINET 344-50297-00 72Vdc, 9Ah Only for 3000 max for 3000XL max for 3000 12 battery cabinets SITE WIRING FAULT WARNING 3 battery cabinets OUT RS232 2 IN 1 Data line protection 26 27 CAUTION: The RS232 and USB communications ports cannot operate simultaneously. 1 - Connect the RS232 26 or USB 27 communications cable to the serial port or the USB port on the computer. 2 - Connect the other end of the communications cable 26 or 27 to the RS232 2 or USB 1 communications port on the UPS. The UPS can now communicate with all MGE UPS SYSTEMS supervision, set-up or safety software. 2.6 Connection to the data-line protection port (optional) TO BATTERY CABINET 344-50297-00 72Vdc, 9Ah Only for 3000 max for 3000XL max for 3000 12 battery cabinets SITE WIRING FAULT WARNING 3 battery cabinets OUT RS232 IN Data line protection The data-line protection function on the UPS eliminates overvoltage flowing on the computer-network lines. Simply connect the line to be protected to the UPS using the data-line protection connectors (IN and OUT) as indicated opposite (RJ45 cables not supplied). Page 14-3400723100/AD U.S. PAT. No. 6,094,363 BATTERY CONNECTOR Volt: 72Vdc 40A

Pb 2. Installation 2.7 Installation of the communications-card option RS232 1 - Remove the slot cover 5 secured by two screws. TO BATTERY CABINET 2 - Insert the card in the slot. 344-50297-00 72Vdc, 9Ah Only for 3000 max for 3000XL max for 3000 12 battery cabinets SITE WIRING FAULT WARNING 3 battery cabinets OUT IN Data line protection 5 Slot for the communications-card option. 3 - Secure the cover with the two screws. It is not necessary to shut down the UPS to install the communications card. 3400723100/AD - Page 15

3. Operation 3.1 Start-up 1 2 15 16 17 Press the ON / OFF button 15. The buzzer beeps and all the LEDs come ON. The buzzer beeps twice during the self-test, then button 15 remains ON, indicating that the receptacles are supplied with power. - AC power is present: Only button 15 is ON. The protected equipment is supplied by the AC-power source. - AC power is absent: Button 15 and LED 16 are ON. The protected equipment is supplied by the UPS, operating on battery power. % % All the connected equipment is supplied with power. 1 2 % % Page 16-3400723100/AD

3. Operation 3.3 Operation on battery power (following failure of AC-input power) Transfer to battery power 16 The AC-input power is out of tolerances, LED 16 goes ON. During operation on battery power, the buzzer beeps every ten seconds. The equipment connected to the UPS is supplied by the battery. 1 2 % % Threshold for the low-battery warning 16 When the threshold is reached, the buzzer beeps every three seconds. The low-battery warning threshold can be set by the user, with the UPS Driver software. There is very little remaining battery backup time. Close all applications because UPS automatic shutdown is imminent. 1 2 When the battery reaches the end of its backup time, the UPS shuts down and all the LEDs go OFF. % % The equipment is no longer supplied with power. The UPS automatically restarts when power returns. NOTE: If the UPS does not restart, check that the automatic restart when power returns function has not been disabled (see section 3.4 Personalization). 3400723100/AD - Page 17

3. Operation 3.4 Personalization (optional) Function Personalization parameters can be set and modified using the UPS Driver software installed on a computer that is connected to the UPS (see section 2.5 Connection to the RS232 or USB communications port). Check that the RS232 26 communications cable is connected. UPS Driver installation: 1 - Insert the Solution-Pac CD-ROM containing the UPS Driver software in the drive of a PC running Windows. 2 - Open the Windows File manager or Explorer and select the CD-ROM drive. 3 - Double-click "\Emb\Evolutio\Config\Setup.exe". Once UPS Driver has been installed, UPS parameters can be modified in a window containing a number of tabs, each presenting a set of parameters : ON / OFF conditions tab Configurable function Automatic restart Cold start Forced reboot Energy saving UPS ON / OFF via software Default setting Enabled Enabled Enabled Disabled Enabled Options Disabled Disabled Disabled Enabled Disabled Battery tab Configurable function Interval between automatic battery tests Low-battery warning threshold Configuration of additional battery modules Protection against deep discharges Default setting Once a week 20% of the remaining battery backup time Display the number of standard EXB modules connected to the UPS Enabled Options Every day Once a month No test 10 to 40% of the remaining battery backup time Back-up time for non-standard batteries (for 3000XL only) Disabled Page 18-3400723100/AD

3. Operation Voltage-thresholds tab Configurable function Output voltage on battery power Upper threshold for transfer to battery power Fader-mode cut-in threshold Booster-mode cut-in threshold Lower threshold for transfer to battery power Maximum input-voltage range Default setting 120 V 151 V 132 V 102 V 89 V Disabled Options 100 V - 127 V 141 V to 153 V 127 V to 138 V 92 V to 108 V 80 V to 94 V Enabled (1) Lower threshold for transfer to battery mode = 70 V Sensitivity tab Configurable function UPS sensitivity level Default setting Normal Options High or low NOTE: For more information about these settings, refer to the Help function of the "UPS Driver" software. 3400723100/AD - Page 19

4. Maintenance 4.1 Trouble-shooting Troubleshooting not requiring MGE UPS SYSTEMS after-sales support (all versions) Indication LED 18 flashes and the buzzer beeps once. LED 17 flashes. Signification UPS overload. The power drawn by the connected equipment exceeds UPS capacity. A battery fault was detected during the automatic battery test. Correction Check the power drawn by the equipment and disconnect any non-priority devices. Replace the battery module (see section 4.2). Troubleshooting requiring MGE UPS SYSTEMS after-sales support Indication LED 17 goes ON and the buzzer sounds continuously. Signification UPS electronics have detected a UPS fault. The connected equipment is no longer supplied. The equipment connected to the UPS is no longer protected. Correction Call the after-sales support department. Page 20-3400723100/AD

3400723100/AD - Page 21

4. Maintenance F - Remove the screw securing the battery cover. G - Remove the cover. F G H I - Disconnect the battery module. - Remove the battery module. H I Battery Replacement Chart Component Manufacturer Manufacturer s Catalog Number 12V 7Ah (in 2200VA) Panasonic LC-R127 12V 7Ah (in 3000VA ) Panasonic LC-R129 Installation of the new battery module Carry out the above operation in reverse order. CAUTION: risk of electric arc when connecting the battery. To maintain an identical level of performance and safety, use a battery module identical to that previously mounted in the UPS. Press the two parts of the battery connector tightly together to ensure proper connection. Page 22-3400723100/AD

5. Environment This product has been designed to respect the environment: It does not contain CFCs or HCFCs. UPS recycling at the end of service life: MGE UPS SYSTEMS undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products recovered at the end of their service life (contact your MGE branch office). Packing: UPS packing materials must be recycled in compliance with all applicable regulations. WARNING: This product contains lead-acid batteries. Lead is a dangerous substance for the environment if it is not properly recycled by specialized companies. Web site: www.mgeups.com 3400723100/AD - Page 23

6. Appendices 6.1 Technical data Simplified diagram Filter Booster / fader transformer Input Output Inverter Charger Battery Page 24-3400723100/AD

6. Appendices Technical characteristics Pulsar Evolution 2200 Pulsar Evolution 3000 Pulsar Evolution 3000 XL Output rating 1920 VA / 1540 W (1) 2880 VA / 2000 W 2568 VA / 2000 W AC-input power Voltage Frequency Output power (operation on battery power) Voltage Frequency Single phase, 80 V to 153 V (1) 47 Hz to 70 Hz (50 Hz system) or 56.5 Hz to 70 Hz (2) (60 Hz system) Single-phase, 120 V (3) (+ 6% / - 10%) 50/60 Hz +/- 1 Hz Battery 6 x 12 V, 7 Ah, sealed leadacid, maintenance free 6 x 12 V, 9 Ah, sealed lead-acid, maintenance free external Environment Noise level (operation on AC-input power) Operating temperature Relative humidity <40 dba 0 to 40 C 20 to 90% (without condensation) (1) The upper and lower thresholds may be set using the UPS Driver software. (2) Or 40 Hz in low-sensitivity mode (may be set using the UPS Driver software). (3) Adjustable from 100 to 127 V using the UPS Driver software. 3400723100/AD - Page 25

6. Appendices Examples of battery backup times Pulsar Evolution 2200 1 data server + 1 hard disk 2 distributed servers + 1 hub 8 rack-mounted servers 0 5 10 15 20 25 30 t (min) Pulsar Evolution 3000 1 data server + 1 hard disk 4 distributed servers + 1 hub + 1 router 12 rack-mounted servers 0 5 10 15 20 25 30 35 t (min) Pulsar Evolution 3000 XL + 3 EXB 1 telecom device 1 set of telecom devices 1 large set of telecom devices 0 100 200 300 400 500 t (min) Page 26-3400723100/AD

6. Appendices 6.2 Glossary Backup time Bar graph Battery module (additional) Booster mode De-energized Equipment Fader mode Input circuit breaker Output circuit breaker Personalization RS232 communications port Programmable receptacles Receptacles Solution-Pac UPS UPS Driver USB communications port Time that the connected equipment can operate on battery power if AC-input power fails. Device on the front panel indicating the percent remaining backup time or the percent load. Additional battery modules connected in parallel to increase the UPS backup time. Automatic UPS operating mode whereby the input-power voltage is increased if it drops below a value set in the personalization parameters, thus avoiding a battery discharge. The UPS must be physically disconnected from the AC-input power. Devices and systems connected to the UPS output. Automatic UPS operating mode whereby the input-power voltage is decreased if it rises above a value set in the personalization parameters, thus avoiding a battery discharge. Circuit breaker protecting the upstream distribution system against UPS faults. Circuit breaker protecting the UPS against high overloads or faults on the connected equipment. The parameters for a number of UPS functions may be modified using the UPS Driver software to adapt UPS operation to user needs. For UPS connection to a computer via the serial port. Pulsar Evolution has two programmable receptacles. They may be used for sequential start-up of protected equipment, shedding of non-critical loads during operation on battery power or management of operating priorities to provide the most critical devices with more backup time before battery power runs out. These receptacles may be programmed using the Solution-Pac software on the CD-ROM supplied with the UPS. Receptacle that allows you to connect the equipment you want to protect. MGE UPS SYSTEMS safety, set-up and supervision software suite on the CD-ROM supplied with the UPS. Uninterruptible Power Supply. Communications software on the CD-ROM supplied with the UPS. It may be used to personalize the default settings. For UPS connection to a computer via the USB port. 3400723100/AD - Page 27

6. Appendices 6.3 Index A Automatic start...18 B Bar graph...9 Battery Additional modules...8 Backup time...26 End of backup time...17 Fault...9 Personalization...18 Recycling...23 Replacement...21, 22 Threshold for low-battery warning...17 Transfer to battery power...9, 17 Buttons...9 Buzzer...17 C Circuit breakers Battery circuit breaker...8 Input circuit breaker...8 Output circuit breaker...8 Communication Cards...8, 15 Ports...8, 14 Connections Data-line protection...14 RS232 communications port...14 USB communications port...14 D Dimensions...7 E Environment...23 F Fault (UPS)...9 L LEDs...9 M Mode Booster mode...9, 16 Fader mode...9, 16 Sleep mode (automatic start)...18 O Overloads...9, 20 P Personalization...18 Battery...18 ON / OFF conditions...18 Output...19 Ports RS232...8, 14 USB...8, 14 Programmable receptacles...8, 9 S Safety...21 Start-up...16 T Technical characteristics...25 Temperature (excessive ambient)...25 U UPS Driver...16, 17, 18, 25 UPS ON / OFF via software...18 W Web site...23 Weight...7 Page 28-3400723100/AD

1660 Scenic Avenue Costa Mesa, CA 92626 USA www.mgeups.com