BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

Similar documents
21", 33", 45", & 61" Installation & Operation Manual

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

MINISTICK TM UV Germicidal Ultraviolet Light

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

Installer s Manual. PCO/UV N-Duct Model

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WARNING Risk of property damage, injury, or death.

HARDWARE KIT INSTALLATION GLOVES

INSTALLATION INSTRUCTIONS

UV-AIRE AIR PURIFYING SYSTEM

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Installation Instructions

UV-AIRE AIR PURIFYING SYSTEM

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Installation & Maintenance of the Fresh-Aire UV Tubular Rack System for Commercial Air Handler Systems

COILCARE PM. Installation Instructions and Operating Manual. CoilCare Series BioZone Scientific International, Inc.

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

PHOTO-CATALYTIC AIR PURIFIER SYSTEMS

Installation Instructions

EXPERIENCE THE NEW IAQ REFRESH YOUR AIR

CAUTION: Read manual carefully for proper procedures and operation.

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

PUSH BUTTON KEY CABINET

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

Ultraviolet Systems RXIU-A02A, RXIU-A03A TREATMENT SYSTEMS

Model 8144NC Fresh Air Ventilator

UV100A Ultraviolet Systems UV100A1000 AND UV100A1018 AIR TREATMENT SYSTEMS UV100A1059 AND UV100A2008 SURFACE TREATMENT SYSTEMS

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

AQUA2000 From O3PURE

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

MaxLite LED Linear HighBay Fixtures

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

Installation Instructions

MODEL 950C-NP-UV Installation and Owners Manual

Further information: Berriman Associates Model 850P.2 Owners Manual

MCI. SynAIRgPURE. Owner s Manual

Automatic Emergency Light

Submersible Pond Pump with UV 800 Gallons Per Hour

INSTALLATION, MAINTENANCE & OPERATION GUIDE. MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER. ITEM # Sanuvair S V EN

SUBMERSIBLE MINI-PUMP

Installation / Operation Instructions Sunnex ORION Series Exam Lights

EBS PRODUCTS

Air Curtain. Installation, Operating and Maintenance Instructions

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

Illumifalls Patio Pond

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

INSTALLATION TEMPLATE

BEFORE YOU BEGIN LIST OF COMPONENTS. Isopropyl SWITCH SCOTCH-BRITE PAD ALCOHOL PREP PAD SWITCH HARNESS REVOLVER PCM COVER STICKER

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

AEROMOTIVE Part # & Mustang 5.0L Stealth Fuel System Kit INSTALLATION INSTRUCTIONS

Model G14SD Vapor Management System

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

LED LARGE WALL PACK (CUTOFF & STANDARD)

INSTALLATION INSTRUCTION & OWNER S MANUAL

NANOpure Infinity UV Module Upgrade

Owner s Manual & Safety Instructions

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

HQUA. UV Water Sterilizer Instruction Manual. Contents

110 Volt/12 Volt Portable Inflator

USER S MANUAL & WARRANTY INFORMATION

StormPro BA Series Sump Pump

UNPACKING THE UNIT. Alcohol cleaning pad

Dispenser & Warmer RIC-1909 RIC-1909EXP

14.4 CORDLESS DRILL ASSEMBLY AND OPERATING INSTRUCTIONS

CTFRP Series Power Supplies

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Use and Care Guide.

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

12 Volt Heavy-Duty Air Inflator

LIGHTNING PLUS 120 WATT / 6 OUTLET VOLT POWER SUPPLY & STROBE LIGHT KIT 6 Different Light Patterns 8006 SERIES INSTALLATION INSTRUCTIONS

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

INFINITY-1 HALOGEN LIGHT BAR INSTALLATION MANUAL 7000 SERIES

INFINITY-3 STROBE LED BAR INSTALLATION MANUAL 7700 SERIES

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

6 OFF ROAD LIGHT BAR

AEROMOTIVE Part # Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

Thank you for purchasing a 911EP GALAXY Light Bar! Every light bar is carefully inspected for defects prior to shipment.

IMPORTANT: SAFETY INSTRUCTIONS

Customer Support

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

Page Number. Contents: Product Features 2. Physical Data 2. Nomenclature. 3. Blower Performance 3. Electrical Data 4. Warranty.. 6

37SCENE 46SCENE 79SCENE

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

CAMBELT TENSION GAUGE

StormPro BCV400 Sewage Ejector Pump

Installation & Operation Manual Chef Base

RESPA -SD or Gideon HVAC Fresh Air Filtration System Installation Guidelines for John Deere 450J, 550J, 650J, 700J, 750J, 850J Crawlers

Users Manual Certified Series Direct Drive Pump 1-7 LPM

Spotlight 1,000,000 Power Series Cordless Rechargeable

Transcription:

ON OFF ON OFF 250V/3 Amp Fuse Only BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems Installation & Operation Manual STD O3 Model 1S14 #06400 #06403 Model 1S16 #06401 #06404 Model 1S20 #06402 #06405 250V/3 Amp Fuse Only STD O3 Model 2S14 #06406 #06409 Model 2S16 #06407 #06410 Model 2S20 #06408 #06411 GENERAL This product is designed to help disinfect the internal surfaces of heating, ventilation, and air conditioning systems. Bacteria and viruses that are in the air stream that passes through the system will also be reduced. The result is an improved level of indoor air quality for occupants and improved system hygiene. The Bio-Fighter emits ultraviolet(uvc) radiation at a frequency of 254 nanometers, which has been proven effective in damaging the DNA of microorganisms such as viruses, bacteria, yeast and molds. This process either destroys the microorganism or neutralizes its ability to reproduce. FEATURES Reduces or prevents mold growth on HVAC coils, allowing them to operate at peak efficiency. Also significantly reduces bacteria, viruses, fungi, and yeasts in the ductwork. Remote and/or fixed lamp configurations. Multi-voltage electronic ballast. 6-ft lamp cables. INCLUDED INSIDE BOX Bio-Fighter Triad FlexMount UV light system UV lamp(s) Power cord Sheet metal screws AHU viewport (2S models) Gaskets Installation & operation manual UV warning label for duct Registration card TOOLS REQUIRED FOR INSTALLATION Electric drill Phillips screw bit or screwdriver 1" drill bit or holecutter Eye protection 1/2" drill bit (2S models) BEFORE INSTALLING Read all instructions carefully. Failure to do so could damage the equipment or cause harm to yourself or others. Acknowledge all warnings. Only qualified technicians should perform the installation. 2006 Dust Free All rights reserved. 212852-00 Rev. 2A 1/06 PO Box 519 Royse City, TX 75189 PH: 1-972-635-9564 Http://www.dustfree.com 2002554 ETL LISTED CONFORMS TO UL STD 1598 CERTIFIED TO CSA STD C22.2 NO. 250.0

BIO-FIGHTER TRIAD FLEXMOUNT 1S, 2S INSTALLATION & OPERATION MANUAL Dimensions Device Base - 6 3 /4"L x 11"W x 2"H Remote Lamp Housing - 3 5 /8"L x 3"W x 1 1 /4"H Weight: Triad FlexMount - 4 1 /2 lbs. Electrical: 120V-240V, 50/60Hz, 1PH. 3 amp-250v fuse. Listings: FIFRA - File # 73316 (Federal Insecticide Fungicide Rodentcide Act) ETL Safety Agency - File #2002554 U.S. Patent Nos. 5,334,347, 5,817,276, 6,245,293, 6,267,924, 6,280,686, 6,313,470, 6,627,000, 6,539,727, 6,932,494, 6,550,257. Specifications subject to change without notice. IMPORTANT: The device must be installed in compliance with all national and local electrical and mechanical codes. Failure to do so will void ETL safety listing and Dust Free warranty. SELECTING A LOCATION This device installs in the air handling system. Select a mounting location with enough clearance for the lamp to be installed and replaced easily. Allow approximately 20" depending on lamp length. Nearby access to 120V or 240V power is required. Any modification to the supplied power cord will void ETL safety listing and Dust Free warranty. 2" 6.75" 3" 11" REMOTE LAMP HOUSING (2S models) 1.25" 3.6" 2 SPECIAL INSTALLATION NOTES Do not install in closet return grille applications. Do not install in outdoor applications. Do not expose wiring or plastic parts to UV-C light. Do not install where UV-C light can be seen after installation. Do not install beneath a humidifier. If the UV device is installed on the inlet side (return air side) of a coil, make sure that the HVAC system is configured such that the blower is located between the return air filter and the inlet side (return air side) of the coil, such as would be found in a traditional upflow, or horizontal furnace with the coil placed after the heat exchanger. If the UV device is installed near an air filter, check with filter manufacturer for UV-C resistance properties. If the desired UV installation location is intended to irradiate an air filter, to neutralize the microbiological matter on the air filter surface, such as would be found in the return air drop of a basement application or in the return plenum of a horizontal system in an attic; take precautions as described in note above, and make sure the UV fixture is placed on the return side of the filter. DO NOT INSTALL THE UV FIXTURE ON EITHER SIDE OF THE FILTER IN HALL / CLOSET RETURN AIR APPLICATIONS. (See ATTEN- TION! Warning sheet #212945-00).

The FlexMount may be installed in a fixedlamp and/or remote-lamp configuration. BASE MOUNTING (Fig.1) Remove the cover of the device and mount the base to the air handling system using the included sheet metal screws. Fixed-lamp Only: Using the mounted base as a template, use a 1" bit or holecutter to make the lamp hole(s) required. Viewport shield(s) must be removed prior to drilling. INSTALLING THE FIXED-LAMP (Fig.2 ) To maximize the efficiency and life of the UVC lamp, clean each lamp prior to installation. Use isopropyl alcohol and cotton cloth to wipe dust and fingerprints from the lamp. Gently insert the lamp into the lamp hole. Slide the bracket over the he retaining lip of the lamp and tighten the two knurled nuts until the lamp is securely fastened. The lamp seals against the base of the unit using a rubber grommet which prevents air leaks. Repeat for each lamp of the installation. Drill the lamp and viewport holes for fixed-lamp configuration. Fig. 1 Mount the device using included sheet metal screws. CAUTION UVC Light May Degrade Plastic and Rubber. Shield exposed plastic drain pans, wire insulation, flex duct, or other plastic/rubber components from UVC light. CAUTION Clean lamp(s) prior to installation. Failure to remove dirt and fingerprints from the lamp(s) could shorten their lifespan. Fig. 2 Lamp is secured with a sliding bracket tightened with two knurled nuts. CONNECTING THE FIXED-LAMP HARNESS (Fig.3 ) After lamp has been installed, attach electrical harness. The harness connector is asymmetrical and can only be attached one way. If the harness does not attach easily, rotate 90 degrees and try again. UV-C Light Hazard. UV-C light can cause temporary or permanent loss of vision, and sunburn. Take precautions to protect eyes and skin from direct exposure. CAUTION Sharp Edge Hazard. Be careful of sharp edges on device and HVAC equipment while installing the device. Personal injury may result. 3 Fig. 3 Attach electrical harness to lamp.

REMOTE LAMP BASE MOUNTING (Fig.4) Remove the remote lamp housing from the remote lamp base by removing the knurled nuts. Then install the remote lamp base to the surface with the includes mounting screws. Using the remote lamp base as a template, drill a 1" hole for the lamp. INSTALLING THE REMOTE-LAMP (Fig.5 ) To maximize the efficiency and life of the UVC lamp, clean each lamp prior to installation. Use isopropyl alcohol and cotton cloth to wipe dust and fingerprints from the lamp. Gently insert the lamp into the lamp hole. Slide the bracket over the he retaining lip of the lamp and tighten the two knurled nuts until the lamp is securely fastened. The lamp seals against the base of the unit using a rubber grommet which prevents air leaks. Repeat for each lamp of the installation. Fig. 4 Lamp is secured with a sliding bracket tightened with two knurled nuts. Fig. 5 Lamp is secured with a sliding bracket tightened with two knurled nuts. UVC Light Hazard. UVC light can cause temporary or permanent loss of vision, and sunburn. Take precautions to protect eyes and skin from direct exposure. REMOTE LAMP HOUSING (Fig.6 ) After lamp has been installed, reinstall the remote lamp housing using the knurled nuts. The remote lamp housing must be in place prior to attaching the electrical harness. Mercury Hazard. Do Not Break. Each UVC lamp contains a small amount of Mercury. May cause redness or irritation. Use proper disposal techniques in case of breakage. See page 6. CAUTION Clean lamp(s) prior to installation. Failure to remove dirt and fingerprints from the lamp(s) could shorten their lifespan. 4 Fig. 6 Reinstall lamp housing.

CONNECTING THE HARNESS (Fig.7) With the lamp housing in place attach the connector to the lamp. Hold back the protective boot to expose the harness connector. The harness connector is asymmetrical and can only be attached one way. If the harness does not attach easily, rotate 90 degrees and try again. After the harness connector is attached, slide the protective boot over the lamp/connector. The protective boot fits snugly over the lamp and seals the connection from moisture, dust, etc. CONNECT POWER AND CHECK OPERATION Reattach the base cover and connect the device to proper power. If optional whip-type power cord (#06303) is used see fig. 8 for power connection. The device power switch must be turned on and device checked for operation using the viewport. The lamp(s) should be radiating a bright blue light. Whip-type Power Cord Option Connect green wire to ground. Connect black and white wires to proper power. Fig. 8 Optional whip-type power cord. Fig. 7 Attach lamp harness to lamp. The plastic boot slips over the lamp and seals the connection from moisture. INSTALLING THE AHU (2S models) The FlexMount 2S comes with a UV-C safe viewport that must be installed separately. To install the viewport, select a location near the lamp installation and drill a 1/2" hole in the duct. Then press the viewport into the hole. OPERATION Under normal conditions the device should be operated continuously to extend the life of the lamp(s), and to increase the effectiveness in disinfecting the location selected. A convenient power switch is located on the device, and should be turned off before any maintenance on the device or HVAC system is performed. UV-C Light Hazard. UV-C light can cause temporary or permanent loss of vision, and sunburn. Take precautions to protect eyes and skin from direct exposure. 5 IF THE LAMP DOES NOT ILLUMINATE Check that the lamp connector is securely attached to lamp. Check that base cover is properly in place. A safety interlock prevents device operation when cover is not properly in place. Check that the fuse is in good working order. Replace if necessary. Check that proper power is being supplied to the device, and that switch lights when turned on.

ON OFF 250V/3 Amp Fuse Only ON OFF 250V/3 Amp Fuse Only BIO-FIGHTER TRIAD FLEXMOUNT 1S, 2S INSTALLATION & OPERATION MANUAL INSTALL REMOTE LAMP KIT (Optional) The optional remote lamp kit (part #06412) converts a single fixed-lamp FlexMount into a remote-lamp model, and a dual fixed/remotelamp FlexMount into a dual remote-lamp model. (See fig.9) 1. Disconnect power cord and remove cover. 2. Remove desired knockout plug (1S models) or remaining knockout plug (2S models). 3. Insert fitting into knockout hole and secure with nut. (See fig.10) 4. Remove outer finish nut from fitting and insert lamp cord through finish nut and fitting. Tighten finish nut to secure lamp cord. (See fig.11) 5. Locate lamp connector and insert 4 lamp cord leads as shown. (See fig.12) 6. Plug lamp connector into the electrical harness connector. The harness connector is asymmetrical and can only be attached one way. If the harness does not attach easily, rotate 90 degrees and try again. (See fig.13) 7. Replace cover. 8. Install remote lamp base as shown on pages 4-5. 9. Connect power cord and check operation. Fig. 10 Insert fitting into knockout hole and secure with nut. Fig. 11 Insert lamp cord through fitting nut and fitting. Secure with fitting nut. Yellow Blue Red Black Fig. 12 Insert lamp cord leads into lamp connector. From ballast. From lamp. Fig. 9 Single and dual lamp FlexMounts in full-remote configurations. Fig. 13 Plug lamp connector into electrical harness. 6

FIXED-LAMP REPLACEMENT(Annually) The lamp should be replaced annually even if it appears to be operating normally. UVC energy production diminishes over time. 1. Obtain the correct replacement lamp for your model. 2. Disconnect power to the equipment. 3. Open the cover of the device. Allow lamp to cool 10 minutes before touching. 4. Disconnect the electrical connector to the lamp. 5. Unscrew the two knurled nuts of the lamp retaining bracket and slide the bracket away from the lamp retaining lip. 6. Carefully remove the UV lamp and replace it with the new lamp. Be sure to clean the lamp of dust and fingerprints prior to installation. 7. Slide the retaining bracket back in place and tighten knurled nuts. 8. Reconnect electrical connector to the lamp. 9. Close the cover of the device. 10. Reconnect power. 11. Verify operation. REMOTE-LAMP REPLACEMENT(Annually) The lamp should be replaced annually even if it appears to be operating normally. UV-C energy production diminishes over time. 1. Obtain the correct replacement lamp for your model. 2. Disconnect power to the equipment. 3. Open the cover of the device. Allow lamp to cool 10 minutes before touching. Mercury Hazard. Do Not Break. Each UVC lamp contains a small amount of Mercury. May cause redness or irritation. Use proper disposal techniques in case of breakage. 7 REMOTE-LAMP REPLACEMENT(Cont'd) 4. Disconnect the electrical connector to the lamp. 5. Remove the remote lamp housing. 6. Unscrew the two knurled nuts of the lamp retaining bracket and slide the bracket away from the lamp retaining lip. 7. Carefully remove the UV-C lamp and replace it with the new lamp. Be sure to clean the lamp of dust and fingerprints prior to installation. 8. Slide the retaining bracket back in place and tighten knurled nuts. 9. Reattach the remote lamp housing. The remote lamp housing must be in place prior to attaching the electrical connector. 10. Reconnect electrical connector to the lamp. 11. Reconnect power. 12. Verify operation. FUSE REPLACEMENT 1. Disconnect power cord. 2. Unscrew the knob marked "Fuse" and remove fuse. 3. Install new fuse and screw knob back in place. Only use a 250V/3 amp fuse. 4. Reconnect power cord. PROPER CLEAN-UP TECHNIQUE IN CASE OF LAMP BREAKAGE Wear protective gloves, eyewear and mask. Sweep the broken glass and debris into a plastic bag, seal the bag, and dispose of properly. Contact your local waste management office for proper disposal. Do not use a vacuum cleaner. Do not incinerate. Burn Hazard. During replacement, allow lamps to cool 10 minutes before removing them. Personal injury may result.

TROUBLESHOOTING Maintenance and troubleshooting should be performed by a qualified technician. Device fails to operate. (On/Off switch light is not lit.) 1. Check that device is connected to proper power. 2. Check that fuse is in good working order. Replace with 250V/3A fuse if necessary. 3. Check that safety switch is activated. Device fails to operate. (On/Off switch light is lit.) 1. Check that device is connected to proper power. 2. Check that ballast is receiving correct power. Replace ballast if necessary. 3. Check continuity of lamp filaments. (Replace lamp if necessary.) 4. Check that lamp is properly connected to lamp connector. 5. Check that wires are properly connected to lamp and ballast. Replacement Parts Part No. UVC Lamp - 14".............. 06413 UVC Lamp - 16".............. 06417 UVC Lamp - 20".............. 06421 UVC-O3 Lamp - 14"............ 06415 UVC-O3 Lamp - 16"........... 06419 UVC-O3 Lamp - 20"........... 06423 Ballast - Multi-Voltage.......... 06426 Power Cord (120V)............ 06309 Power Cord (240V)............ 06215 Power Cord Whip-Type......... 06303 Power Cord Receptacle....... 212106-00 Cover Interlock Switch........ 212108-00 Slide Bracket Springs (2)..... 210-0005-001 Slide Bracket............... 210929-00 Knurled Nuts (2)............. 210226-00 Lighted On/Off Switch....... 750-0026-001 Fuseholder................. 212225-00 Fuse..................... 750-0108-001 For information on the dealer in your area call: 1-972- 635-9564. Visit us at http://www.dustfree.com LAMP DISPOSAL Dispose of your spent UVC lamps at your local recycling center. You may also send your spent lamps in the same container you received your replacement lamps to: Dust Free Lamp Reclamation 1112 Industrial Drive Royse City, TX 75189 8

LIMITED LIFETIME WARRANTY Dust Free, LP warrants this Bio-Fighter UV-C Light to be free from defects in materials and workmanship under normal use and service, for as long as it is owned by the original purchaser. This warranty does not cover UV-C lamp(s), which carry a one (1) year warranty from the date of installation, or the ballast(s) which carry(s) a three (3) year warranty. This warranty does not cover cosmetic damage, damage due to acts of God, damage as a result of handling or shipment, negligence, misuse, connection to improper voltage, improper maintenance, or abuse. This warranty is void if defect(s) result from failure to have this unit installed by a qualified, properly licensed, heating and air conditioning contractor in compliance with all local building and construction codes. Dust Free, LP's exclusive obligation under this warranty shall be to supply, without charge, a replacement for any covered component of the Bio-Fighter UV Light which is found to be defective within the parameters defined herein. Dust Free, LP reserves the right to replace or repair the defective part or component. Dust Free, LP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. (Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.) THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE AND Dust Free, LP EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES, WHETHER WRITTEN OR ORAL, IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY, WORKMAN- SHIP, OR FITNESS FOR A PARTICULAR USE. If the limited warranty is void due to failure to use a qualified contractor all disclaimers of implied warranties shall be effective upon installation. How to make a warranty claim or have questions answered: Should you have a warranty claim or questions about the warranty policy, contact the distributor or dealer from which you purchased the product. Proof of original purchase and proof of identity that the original purchasing party is filing the claim is required in order to initiate a warranty claim. Defective parts must be returned no later than thirty (30) days after the failure to the installing contractor together with the model number, serial number, and date of installation. All service and removal must be performed by a licensed HVAC contractor. You must pay shipping charges and all other costs of warranty service. Warranty is only valid the United States and Canada. THIS WARRANTY SHALL NOT OBLIGATE THE MANUFACTURER FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY THE INSTALLING CON- TRACTOR AS CONTRASTED TO DEFECTS IN THE GERMICIDAL LIGHT ITSELF. NOTE: Do not return any products or parts to the factory without a factory issued Return Authorization number issued by the Dust Free, LP customer service department. In the event you have any questions concerning the use and care of this product or this warranty which have not been answered to your satisfaction by the distributor or dealer, please call or write the factory. Dust Free PO Box 519 1112 Industrial Drive Royse City, TX 75189 1-972-635-9565 9