Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Similar documents
Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Series ITV1000/2000/3000

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

4 Note 1) Value for communications type. (PROFIBUS DP)

Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only.

Series ITV009. Compact Vacuum Regulator ITV IITV00 02 n. RoHS. How to Order

Series AV2000/3000/4000/5000

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Air Filter. Best Pneumatics 4. Equipment. Air Line

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

Pressure Control Equipment

Standard Specifications

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Standard Specifications

Series 10-ZSE40A(F)/10-ISE40A

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

2-Color Display High-Precision Digital Pressure Switch

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

E22 Proportional Technology

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

Vacuum pump system type

Compact Proportional Solenoid Valve

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Related vacuum products

Manifold Specifications

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

Digital display Pressure range ON/OFF output Linear output Model

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

2-Color Display Digital Pressure Switch

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure,


Series ISA. Air Catch Sensor. For Detection of Work Presence

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Power Valve Precision Regulator

2-Color Display High-Precision Digital Pressure Switch

Soft Start-up Valve. AV2000/3000/4000/5000 Series

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

2-Color Display Digital Pressure Switch

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS.

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

Vacuum Equipment. Application. Series

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

MULTISTAGE MICRO EJECTORS

Low Differential Pressure Sensor ±1% F.S.

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Non-Contact Sensor for Workpiece Placement Verification

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Digital Flow Switch (Sensor Part) Operation Manual

2-Color Display Digital Pressure Switch

25% reduction in volume * PB1013A/Air-operated type without foot

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

Model Pressure range ON/OFF output Linear output

2-Color Display Digital Flow Switch

Small size flow sensor

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

Series PSE560 Pressure Sensor For General Fluids... 90

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

0.35 W (Without light)

DPS280 / DVS280 Series

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in)

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder

AN 00/AN 02/AN 03/25/AN

Rubber Seal VP300/500/700

Booster Regulator/Air Tank Increase factory air pressure by up to twice as much! Air-only operation requires no power supply, reduces

Ready for outdoor use too!

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

Vacuum Module. Series ZX. Ejector System/Vacuum Pump System

We're everywhere you need us to be! Valves. OBSOLETE PRODUCT Check availability. on Proportional Regulator E22 Series

3 Port Solenoid Valve Direct Operated Poppet Type

Model Pressure range ON/OFF output Linear output

Compact Vacuum Ejector

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

For material handling and clamping of small workpieces

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Transcription:

000 Electro-Pneumatic Regulator Electronic Vacuum Regulator Series Series Model Set pressure range Port size Page Series 000 Controls air pressure steplessly in proportion to an electric signal. 0 05 to MPa 0 05 to MPa /4, /8.- Electro Pneumatic Regulator Series 000 Controls air pressure steplessly in proportion to an electric signal. 05 0 05 to 0.9MPa 05 to MPa 0 05 to MPa /4, /8, /.- 05 05 to 0.9MPa Electronic Vacuum Regulator Series 09 Controls vacuum pressure steplessly in proportion to an electric signal. 09. to 80kPa /4.-.-0

000 Electro-Pneumatic Regulator Series 000/000 Standard Specifications Symbol Straight type Right angle type Model Minimum supply pressure Maximum supply pressure Regulating pressure range Voltage Power supply Current consumption Input signal Input impedance () Output signal (monitor output) Output pressure display Weight Current type Voltage type Preset input Current type Voltage type Preset input Sensitivity Temperature characteristics Accuracy Minimum unit Ambient and fluid temperature Enclosure Analog output Switch output 0 0 () 0 0 0 0 Set pressure +MPa MPa MPa 05 to MPa 05 to MPa 05 to 0.9MPa 4V DC ±0%, to 5V DC Power supply voltage 4V DC type: A or less Power supply voltage to 5V DC type: 8A or less 4 to 0mA, 0 to 0mA 0 to 5V DC, 0 to 0V DC 4 points 50Ω or less Approx. 6.5kΩ Approx..7kΩ 05 05 to 5V DC (load impedance: kω or more) 4 to 0mA (sink type) (load impedance: 50Ω or less) NPN open collector output: Max. 0V, 0mA PNP open collector output: Max. 0mA Within ±% (full span) Within % (full span) Within ±% (full span) Within % (full span) Within ±% (full span)/ C ±% (full span) MPa:, kgf/cm :, bar:, PSI: (), kpa: 0 to 50 C (with no condensation) IP65 equivalent 50g 645g Note ) wire type 4 to 0mA is not available. Power supply voltage (4V DC or to 5V DC) is required. Note ) Select either analog output or switch output. Further, when switch output is selected, select either NPN output or PNP output. Note ) The minimum unit for 05 is PSI. AC AV AU AF AR IR VEX SRP AW AMR AWM AWD VBA AL How to Order Power supply voltage 0 0 4 Option Model 000 000 4V DC to 5V DC Monitor output None (for preset input) Analog output to 5V DC Switch output/npn output Switch output/pnp output Analog output 4 to 0mA 0 0 Pressure range 5 MPa MPa 0.9MPa 0 4 Option Input signal Current 4 to 0mA Current 0 to 0mA Voltage 0 to 5V DC Voltage 0 to 0V DC Preset input Thread type N T F Option Rc(PT) NPT NPTF (PF) 0 F Port size 4 /4 (000, 000) /8 (000, 000) / (000) S 4 5 Option Cable connector type S L N Option Q Pressure display unit Straight type m Right angle type m Without cable connector Bracket B C Option Without bracket Flat bracket L-bracket MPa kgf/cm bar PSI kpa.-

000 Series 000/000 tspacer Specification Combinations Specifications : Standard specifications : Combination possible Blank: Combination not possible Applicable model Symbol 0 0 Approx. 89 Approx. 78 qaf000 wafm000 e000 el-bracket rt-bracket 000 Set pressure max. MPa Set pressure max. MPa Set pressure max. 0.9MPa Connection Rc(PT) /4 Connection Rc(PT) /8 Connection Rc(PT) / Bracket Accessories Bracket Connection NPT/4 Connection NPT/8 Connection NPT/ Connection (PF) /4 Connection (PF) /8 Connection (PF) / Standard specifications Optional specifications 5 0 0 04 B C N0 N0 N04 F0 F0 F04 Modular Connection Part Numbers Attachments Description Air filter Mist separator L-bracket T-bracket Spacer Spacer with L-bracket Spacer with T-bracket 0 AF000 AFM000 B0L B0T Y0 Y0L Y0T 0 AF4000 AFM4000 B40L B40T Y40 Y40L Y40T Modular Products and Accessory Combinations Applicable products and accessories q Air filter w Mist separator e L-bracket r T-bracket t Spacer y Spacer with L-bracket u Spacer with T-bracket Applicable model 0 0 AF000 AF4000 AFM000 AFM4000 B0L B40L B0T B40T Y0 Y40 Y0L Y40L Y0T Y40T Accessories (Optional)/Part Numbers Description Flat bracket L-bracket Part No. 0 0 P004 INI-98-0-6 Dimensions Flat bracket 60 0 L-bracket 6 7 7 50 6.6 4 X ø5.5 40 5 5 5 7 70 Approx. 4 Approx. 7 4 qaf4000 wafm4000 e000 4 X ø5.5 6 84 4 X ø7. (0) (7) 0 6 50 R.5.-

Electro-Pneumatic Regulator Series 000/000 Working Principles When the input signal rises, the air supply solenoid valve () turns ON, and the exhaust solenoid valve () turns OFF. Therefore, supply pressure passes through the air supply solenoid valve () and is applied to the pilot chamber (). The pressure in the pilot chamber () increases and operates on the upper surface of the diaphragm (4). As a result, the air supply valve (5) linked to the diaphragm (4) opens, and a portion of the supply pressure becomes output pressure. This output pressure feeds back to the control circuit (8) via the pressure sensor (7). Here, a correct operation functions until the output pressure is proportional to the input signal, making it possible to always obtain output pressure proportional to the input signal. Working Principle Diagram Block diagram Power supply Input signal () Air supply solenoid valve (4) Diaphragm (6) Exhaust valve (5) Supply valve SUP Pressure display (8) Control circuit Supply pressure Output signal () Exhaust solenoid valve (7) Pressure sensor () Pilot chamber EXH OUT EXH AC AV AU AF AR IR VEX SRP AW AMR AWM AWD VBA AL Input signal + (8) Control circuit () Air supply solenoid valve () Exhaust solenoid valve (4) Diaphragm Pilot valve Output pressure (7) Pressure sensor.-

Series 000/000 Series 0 0 9 8 7 6 5 4 0 0 5 50 75 Out Return 0 5 50 75 0 4 6 8 Count 0 Pressure characteristics Set pressure: 5MPa Flow characteristics 5 Supply pressure: MPa Relief flow characteristics 5 Supply pressure: MPa Set point 0 5 0 5 0 5 0 00 400 600 0 0 00 400 600 800 Supply pressure (MPa) Series 0 0 9 8 7 6 5 4 0 0 5 50 75 Out Return 0 5 50 75 0 4 6 8 Count 0 Pressure characteristics Set pressure: 5MPa Flow characteristics 5 Supply pressure: MPa Relief flow characteristics 5 Supply pressure: MPa Set point 0 5 0 5 0 5 Supply pressure (MPa) 0 0 500 0 500 000 0 0 500 0 500 000.-4

Electro-Pneumatic Regulator Series 000/000 Series 0 0 5 50 75 Pressure characteristics Supply pressure (MPa) Series 0 0 5 50 75 0 5 50 75 Set pressure: MPa Set point Flow characteristics 0 500 0 500 000 Out Return 0 5 50 75 Out Return Supply pressure: MPa 0 4 6 8 Count Relief flow characteristics 0 500 0 500 000 0 4 6 8 0 Supply pressure: MPa Count 0 AC AV AU AF AR IR VEX SRP AW AMR AWM AWD VBA AL Pressure characteristics Set pressure: MPa Set point Flow characteristics Supply pressure: MPa Relief flow characteristics Supply pressure: MPa Supply pressure (MPa) 0 0 000 000 4000 50006000 0 0 000 000 4000 5000.-5

Series 000/000 Series 05 0.9 0 5 50 75 Out Return 0 5 50 75 5 0 5 0 4 6 8 Count 0 Pressure characteristics Set pressure: MPa Set point. Supply pressure (MPa) Flow characteristics 0.9 Supply pressure: MPa 0 500 0 500 000 500 Relief flow characteristics 0.9 Supply pressure: MPa 0 500 0 500 000 500 Series 05 0.9 0 5 50 75 Out Return 0 5 50 75 0 4 6 8 Count 0 Pressure characteristics Set pressure: MPa Set point. Supply pressure (MPa) Flow characteristics 0.9 0 0 000 000 4000 5000 60007000 Supply pressure: MPa Relief flow characteristics 0.9 0 0 000 000 4000 5000 6000 Supply pressure: MPa.-6

Electro-Pneumatic Regulator Series 000/000 Dimensions 0.5 M X Cable connection threads () EXH M5 AC 000 AV Solenoid valve EXH M5 9.5 OUT Rc(PT) /4 Exhaust port EXH () SUP () OUT () 9 AU AF AR IR Flat bracket P004 (optional) x Rc(PT) /4, /8 Port size 6 4 x M5 thread depth 6mm through Mounting hole VEX SRP AW AMR AWM OUT AWD 9 6 5 5 R.5 7 VBA -Rc(PT) /4, /8 SUP port, OUT port L-bracket INI-98-0-6 (optional) (0) 0 (7) 6 AL Cable connector (4 wire) Cable connector (4 wire) Right angle type Note) Straight type () 50 4 x ø7 Mounting hole RESET 000 000 UNLOCK SET LOCK 40 5 Note) Do not attempt to rotate, as it does not turn. 84.-7

Series 000/000 Dimensions 0.5 M X Cable connection threads () Solenoid valve EXH 000 5.7 8 OUT 5 Rc(PT) / Exhaust port EXH () x Rc(PT) /4, /8, / Port size Flat bracket P004 (optional) 6 4 SUP () OUT () 4 x M5 thread depth 6mm through Mounting hole OUT 5 7 0 5 6 5 R.5 x Rc(PT) /4, /8, / SUP port, OUT port L-bracket INI-98-0-6 (optional) (0) 0 (7) 6 Cable connector (4 wire) Right angle type Note) Cable connector (4 wire) Straight type 66 () 50 4 x ø7 Mounting hole RESET SET 40 5 000 000 UNLOCK LOCK Note) Do not attempt to rotate, as it does not turn. 84.-8

Series 000/000 Made to Order Specifications Contact regarding detailed dimensions, specifications and delivery times. Order Made Ozone Resistant Specifications Fluoro rubber is used for the rubber parts of seals. 80 Standard part number Ozone resistant specifications Manifold Specifications (Except Series 000) through 8 station manifold. How to Order Manifolds I0 0 5 OUT port size 0 0 /4 /8 Connection thread type N F PT NPT PF Valve stations stations 8 8 stations How to Order Manifold Assemblies Example Electro-pneumatic regulator 00-S-X6 UNLOCK LOCK SET RESET Blanking plate assembly P9800- UNLOCK LOCK SET RESET Electro-pneumatic regulator 050-S-X6 AC AV AU AF AR IR VEX SRP AW AMR AWM AWD VBA AL Stations Manifold base ( stations) I0-0- () I0-0- set ( station manifold base part no.) 00-S-X6 set (Electro-pneumatic regulator part no.) () P9800- set (Blanking plate assembly part no.) 050-S-X6 set (Electro-pneumatic regulator part no.) () The is the symbol for mounting. Add the symbol at the beginning of part numbers for electro-pneumatic regulators, etc. to be mounted on the base. Note ) Electro-pneumatic regulators are counted starting from station on the left side with the OUT ports in front. Note ) The port size for mounted electro-pneumatic regulators is Rc(PT)/4 only. Note ) When there is a large number of stations, use piping with the largest possible inside diameter for the supply side, such as steel piping. Note 4) The use of the straight type cable connector is recommended..-9

Series 000/000 Precautions Be sure to read before handling. Refer to p.0-6 and 0-7 for Safety Instructions and p.- and - for precautions. Warning Caution Air Supply qinstall an air filter near this product on the supply side. Select a filtration degree of 5µm or less. wcompressed air containing large amounts of drainage can cause malfunction of this product and other pneumatic equipment. As a countermeasure, install an aftercooler, air dryer or Drain Catch, etc. eif large amounts of carbon dust are generated by the compressor, it can accumulate inside this product and cause malfunction. For details on the above compressed air quality, refer to 's "Air Preparation Equipment". Caution Oprating Environment qin locations where there is contact with spatter from water, oil or solder, etc., implement suitable protective measures. Handling qdo not use a lubricator on the supply side of this product, as this can cause malfunction. When lubrication of terminal equipment is necessary, connect a lubricator on the output side of this equipment. wif electric power is shut off while pressure is being applied, pressure will be retained on the output side. However, this output pressure is held only temporarily and is not guaranteed. If exhausting of this pressure is desired, shut off the power after reducing the set pressure, and discharge the air using a residual pressure exhaust valve, etc. eif power to this product is cut off due to a power failure, etc. when it is in a controlled state, output pressure will be retained temporarily. Handle carefully when operating with output pressure released to the atmosphere, as air will continue to flow out. Caution Handling rif supply pressure to this product is interrupted while the power is still on, the internal solenoid valve will continue to operate and a humming noise may be generated. Since the life of the product may be shortened, shut off the power supply also when supply pressure is shut off. tin this product, the output side pressure cannot be completely relieved within the range of 05MPa or less. If it is desired to reduce the pressure completely to 0MPa, install a way valve or other device on the output side to exhaust the pressure. ythis product is adjusted for each specification at the time of shipment from the factory. Avoid careless disassembly or removal of parts, as this can lead to malfunction. uthe optional cable connector is a 4 wire type. When the monitor output (analog output or switch output) is not being used, keep it from touching the other wires as this can cause malfunction. iplease note that the right angle cable does not rotate and is limited to only one entry direction. otake the following steps to avoid malfunction due to noise. ) Remove power supply noise during operation by installing a line filter, etc. in the AC power line. ) Install this product and its wiring as far as possible from strong electric fields such as those of motors and power lines, etc. ) Be sure to implement protective measures against load surge for induction loads (solenoid valves, relays, etc.).!0due to the large volume of the output side, a loud exhaust noise will be produced when being used for the purpose of a relief function. Therefore, install a silencer ( Series AN00 or AN400) on the exhaust port (EXH port). The port sizes are Rc/4 and Rc/.!For details on the handling of this product, refer to the instruction manual which is included with the product..-0

Precautions Series 000/000 Be sure to read before handling. Refer to p.0-6 and 0-7 for Safety Instructions and p.- and - for common precautions. Brown Blue White Black 4 Caution Body Note) Current signal type Voltage signal type Wiring diagram Current signal type Vs A Brown White Blue Black Power supply Input signal ND(COMMON) Monitor output Brown Blue White Black Wiring Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple. : (Blue) : (Brown) 4: (Black) : (White) Voltage signal type Vs Vin RESET Preset input type 4 Brown White Blue Black Power supply Input signal ND (COMMON) Input signal Note) A right angle type cable is also available. The entry direction for the right angle type connector is to the left (SUP port side). Never turn the connector as it is not designed to turn. Brown Blue White Black AC AV AU AF AR IR VEX SRP AW AMR AWM AWD VBA AL Vs: Power supply 4V DC to 5V DC A : Input signal 4 to 0mA DC 0 to 0mA DC Vs: Power supply 4V DC to 5V DC Vin: Input signal 0 to 5V DC 0 to 0V DC Preset input type Vs S S Brown Blue White Black Vs: Power supply 4V DC to 5V DC One of the preset pressures P through P4 is selected by the ON/OFF combination of S and S. S S Preset pressure OFF OFF P ON OFF P OFF ON P ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to 0MPa..-