Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Similar documents
How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Series ITV009. Compact Vacuum Regulator ITV IITV00 02 n. RoHS. How to Order

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

4 Note 1) Value for communications type. (PROFIBUS DP)

Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only.

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Vacuum pump system type

Related vacuum products

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Series 10-ZSE40A(F)/10-ISE40A

Series ITV1000/2000/3000

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure,

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

Compact Proportional Solenoid Valve

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Compact Vacuum Ejector

2-Color Display High-Precision Digital Pressure Switch

Transmitters: Relay Valve VR4151/4152

Specifications. Fluid Ambient and fluid temperature ( C)

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

2-Color Display High-Precision Digital Pressure Switch

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

Model Pressure range ON/OFF output Linear output

3 Port Solenoid Valve

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance.

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

Low Differential Pressure Sensor ±1% F.S.

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

Digital display Pressure range ON/OFF output Linear output Model

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Series ISA. Air Catch Sensor. For Detection of Work Presence

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Series AV2000/3000/4000/5000

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS.

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)


SentronicPLUS IO-Link CLASS A Electronic Pressure Regulator. Installation Manual

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

2-Color Display Digital Pressure Switch

Vacuum Ejector with Solid State Timer

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

Sentronic PLUS 614 Series

25% reduction in volume * PB1013A/Air-operated type without foot

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Power Valve Precision Regulator

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Manifold Specifications

Model Pressure range ON/OFF output Linear output

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Non-Contact Sensor for Workpiece Placement Verification

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Soft Start-up Valve. AV2000/3000/4000/5000 Series

THE INSIDE STORY OF THE QPV OR MPV:

Sentronic D 608 Series and 609 Series

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Small size flow sensor

Digital Flow Switch (Sensor Part) Operation Manual

Flow sensor for compressed air

2-Color Display Digital Pressure Switch

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

3 Port Solenoid Valve Direct Operated Poppet Type

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Ejector Valve Unit Series ZYY/ZYX

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Precision Clean Regulator

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Series VQ Port Solenoid Valve

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

Vacuum / Release Unit

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-Color Display Digital Pressure Switch

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in)

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Transcription:

Compact Electro-pneumatic Regulator Series For single unit and single unit for manifold Pressure range 9 Option. MPa. MPa.9 MPa kpa Option How to Order N Power supply voltage 24 VDC ±% 2 to VDC Option Input signal Current type 4 to 2 m A DC Current type to 2 m A DC 2 Voltage type to VDC Voltage type to VDC Built-in One-touch fittings type For single unit Nil Manifold I 2 n 2 Stations 2 stations stations stations U Nil U Symbol Metric size (Light gray) Inch size (Orange) For manifold Symbol Metric size (Light gray) Inch size (Orange) SUP z OUTx (VAC) ø4 ø/2" SUP z OUTx (VAC) ø6 ø/4" ø4 ø/2" Option If a DIN rail longer than the specified stations is required, specify the appli cable stations in two digits. (Maximum stations) Example) I--7 Note) A DIN rail with the length specified by the number of stations is attached to the manifold. For dimensions of the DIN rail, refer to the external dimensions. EXH c (ATM) EXH c (ATM) ø6 ø/4" Nil M Cable connector (Option) N S L Without cable connector Straight type m Right angle type 2 m Bracket/ Option for single unit only Nil Without bracket B C Base type Flat Bracket L-bracket For single unit For manifolds How to Order Manifold Assembly (Example) Indicate the part numbers of electro-pneumatic regulators and options to be mounted below the manifold part number. Example) Due to the common supply/exhaust feature, note that different pressure range combinations are not available. I- set (Manifold part no.) -MS 2 sets (Electro-pneumatic regulator part no. (, 2 stations)) -ML set (Electro-pneumatic regulator part no. ( stations)) Indicate part numbers in order starting from the first station on the D side. Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. The asterisk ( ) specifies mounting. Add an asterisk ( ) at the beginning of electro-pneumatic regulator part numbers to be mounted. VY D side 2 DIN rail -MS -ML 4-8-

Series Specifications Model Min. supply pressure Max. supply pressure Regulating pressure range Maximum flow rate.2 MPa. MPa. to. MPa. to. MPa. to.9 MPa. l/min(anr) (Supply pressure:.2 MPa) Set pressure +. MPa 6 l/min(anr) (Supply pressure:.6 MPa) 6 l/min(anr) (Supply pressure:.6 MPa) 9 Set pressure kpa kpa to kpa 2 l/min(anr) (Supply pressure: kpa) Option Bracket Flat bracket assembly P9822 Voltage Power supply Current consumption Voltage type Input signal Current type Voltage type Input impedance Current type Analog put signal output Linearity Hysteresis Sensitivity Temperature characteristics Operating temperature range Enclosure Connection type Connection size () For single unit Manifold Metric size Inch size Metric size Inch size 24 VDC ±%, 2 to VDC to VDC, to VDC 4 to 2 madc, to 2 madc Approximately kω Approximately 2 Ω Within ±% (Full span) Within.% (Full span) Within ±.% (Full span) Within.2% (Full span) Within ±.2% (Full span)/ C to C (With no condensation) IP6 equivalent Built-in One-touch fittings Weight g or less (without options) Note ) Indicates the weight of a single unit. For I-n Total weight (g) Stations (n) x + (Weight of end block A, B assembly) + Weight (g) of DIN rail Note 2) Specifications other than the following are optional. Pressure range:. MPa,. MPa,.9 MPa, Power supply voltage: 24 VDC, Input signal: to VDC Note ) When there is a downstream flow consumption, pressure may become unstable depending on piping conditions. When using under the conditions equivalent to IP6, connect the fitting or tube to the breathing hole prior to use. (For details, refer to page 4-8- in Specific Product Precautions.) Cable connector Straight type M8-4DSXM4 Power supply voltage 24 VDC type:.2 A or less Power supply voltage 2 to VDC type:.8 A or less to VDC (Load impedance: kω or more) put accuracy: Within ±6% (Full span) z, x, c: ø4 z, x, c: ø/2" z, c: ø6, x: ø4 z, c: ø/4", x: ø/2" L-bracket assembly P982 Right angle type ELWIKA-KV448 PVC2 2M Tighting torque when assembling is. N m. 4-8-4

Compact Electro-pneumatic Regulator Series Working Principle When the input signal rises, the air supply soloenoid valve q turns ON. Due to this, part of the supply pressure passes through the air supply solenoid valve q and changes to output pressure. This product pressure feeds back to the control circuit r via the pressure sensor e. Here, pressure corrections continue until output pressure becomes proportional to the input signal, enabling output pressure that is proportional to the input signal. Diagram of working principle Power supply Input signal Power supply and error LED indication r Control circuit put signal q Air supply solenoid valve w Exhaust solenoid valve e Pressure sensor SUP EXH OUT VY Block diagram Supply pressure Input signal + r Control circuit q Air supply solenoid valve w Exhaust solenoid valve put pressure Discharged to atmosphere e Pressure sensor 4-8-

Series Series Linearity, Hyteresis.8.6.4.2.2.4.6.8 2 7 Input signal (%F.S.).. 2 4 Count With % of signal input Pressure Characteristics Set pressure:. MPa Flow Characteristics 2 Supply pressure:.2 MPa....6.7.8.9 Supply pressure (MPa).2 Set pressure (kpa) 8 6 4 2.. 2 2.. Flow rate (l/min (ANR)) kpa 8 kpa 6 kpa 4 kpa 2 kpa kpa 4 Series Linearity, Hyteresis.8.6.4.2.2.4.6.8 2 7 Input signal (%F.S.).. 2 4 Count With % of signal input Pressure Characteristics.. Set pressure:.2 MPa.2..4..6.7.8.9 Supply pressure (MPa). Flow Characteristics Set pressure (kpa) 6 4 2 Supply pressure:.6 MPa 2 4 6 Flow rate (l/min (ANR)) kpa 4 kpa kpa 2 kpa kpa kpa 7 4-8-6

Compact Electro-pneumatic Regulator Series Series Linearity, Hyteresis.8.6.4.2.2.4.6.8 2 7 Pressure Characteristics...4.6.8. Series 9 Linearity, Hyteresis.. Input signal (%F.S.) Supply pressure (MPa) Set pressure:.4 MPa.2.. 2 4 Flow Characteristics Set pressure (kpa) With % of signal input Supply pressure:. MPa 9 9 kpa 8 kpa 8 7 7 kpa 6 6 kpa kpa 4 4 kpa kpa 2 kpa 2 kpa kpa 2 4 6 7.. Count Flow rate (l/min (ANR)) With % of signal input VY 2 7 Input signal (%F.S.) 2 4 Count Pressure Characteristics.. Set pressure: kpa Flow Characteristics Set pressure (kpa) kpa 2 kpa 2 4 kpa 4 6 kpa 6 8 kpa 8 kpa 2 8 6 4 Supply pressure (kpa) 2.. 2 2.. Flow rate (l/min (ANR)) 4 4-8-7

Series Dimensions For Single Unit 4-ø6 2-ø6 L-bracket (Option) M8 x Cable connection thread Flat bracket (Option) No. SUP OUT EXH 9 VAC ATM Note) When useing under the conditions equivalent to IP6, connect the fitting or tube to the bleed hole prior to use. (For details, refer to page 4-8- in Specific Product Precautions.) Note) Breathing hole (M x.) OUT port (ø4, ø/2") 2 8 88 OUTx 6 89 SUPz VACz EXHc ATMc SUP, VAC port (ø4, ø/2") EXH, ATM port (ø4, ø/2") 9 L-bracket (Option) 2-M x. thread depth. Bracket mounting hole 6-ø. Flat bracket (Option) 74 9 2-ø. 27 9 64 + (.9) 28 Minimium bending radius 8 4 Cable connector (4-wire) Straight type (Option) 8.7 9.9 7 4 Cable connector (4-wire) Right angle type (Option) 6. 8. ø.2 Minimium bending radius 8 27 6.9 Port Location z x c 9.7.7.7 82 Body Body ø4. 4-8-8

Compact Electro-pneumatic Regulator Series Dimensions Single unit for manifold 6 84 Note) Breathing hole (M x.) 2 OUT port (ø4, ø/2") OUTx Bushing assembly M8 x Cable connection thread 86 Note) When useing under the conditions equivalent to IP6, connect the fitting or tube to the bleed hole prior to use. (For details, refer to page 4-8- in Specific Product Precautions.) 9.7 26. 8. 8 2.7 VY Note) For dimensions of the cable connector, refer to single unit on page 4-8-8. 4-8-9

Series Dimensions Manifold 4 2 4 2 4-M x. thread depth Mounting hole Port Location No. z x c SUP OUT EXH 9 VAC ATM Note) Stations are counted starting from the D side. 2 9. L2 L 9. 6 D side 2 stations U side 9 (8) Dimensions in inch are noted in parentheses. 6. 6. SUP, VACzport (ø6, ø/4") 82 89. EXH, ATMcport (ø6, ø/4") 4 2 2 4 2 2 2 OUTxport (ø4, ø/2").7 Note) For dimensions of the cable connector, refer to single unit on page 4-8-8. Manifold stations n L L2 2 6. 7 2 4 9 48 6. 6 2 7 7 8. 8 98 9 6 22 (mm) 8 2. Note) Breathing hole (M x.) Note) When using under the conditions equivalent to IP6, connect the fittings or tubing to the bleed hole prior to use. (For details, refer to Specific Product Precautions on page 4-8-.) 4-8-

Compact Electro-pneumatic Regulator Series Precautions Be sure to read before handling. Refer to pages 4-2- to 4-2-4 for Safety Instructions and Common Precautions. Caution. Install an air filter near this product on the supply side. Select a filtration degree of µm or less. 2. Compressed air containing large amounts of drainage can cause malfunction of this product and other pneumatic equipment. As a countermeasure, install an aftercooler, air dryer or Drain Catch, etc.. If large amounts of carbon dust are generated by the compressor, it can accumulate inside this product and cause malfunction. For details on the above compressed air quality, refer to 4-4-2. Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple. Blue White Black Terminal no. Lead wire color Wiring Caution 2: (White) 4: (Black) : () Wiring diagram : (Blue) Current signal type Vs A Power supply 2 4 White Blue Black Signal COM Monitor Blue White Black Note) Vs : Power supply 24 VDC 2 to VDC A : Input signal 4 to 2 ADC to 2 ADC Monitor output wiring diagram Analog output, voltage type Air Supply Wiring Voltage signal type Blue Vs White Black Vin Vs : Power supply 24 VDC 2 to VDC Vin : Input signal to VDC to VDC Blue Body Note) A right angle type is also available. The entry directions for the right angle type connector is downward (OUT port side). Never turn the connector as it is not designed to turn. If forced, it will damage the connector port. Caution Handling. Do not use a lubricator on the supply side of this product, as this can cause a malfunction. When lubrication of terminal equipment is necessary, connect a lubricator on the output side of this regulator. 2. If electric power is shut off while pressure is being applied, output pressure will be maintained. However, this output pressure is held only temporarily and is not guaranteed. If exhausting of this pressure is desired, shut off the power after reducing the set pressure, and discharge the air using a residual pressure exhaust valve, etc.. If power supply to this regulator is cut off due to a power failure, etc., when it is in a regulated state, output pressure will be maintained temporarily. Handle carefully when operaing with output pressure released to the atmosphere, as air will continue to flow out until reaching atmospheric pressure. 4. If supply pressure to this regulator is interrupted while the power is still on, the internal solenoid valve will continue to operate and a humming noise may be generated. Since the life of the solenoid valve may be shortened by this, be sure to shut off the power supply when supply pressure is shut off.. This product is adjusted for each specification at the time of shipment from the factory. Avoid unnecessary disassembly or removal of parts, as this can lead to a malfunction. 6. The optional cable connector is a 4-wire type. When the monitor output (analog output) is not being used, keep the monitor output wire (black) from touching the other wires as this can cause a malfunction. 7. Use caution that the right angle cable does not rotate and is limited to only one entry direction. 8. Take the following steps to avoid malfunction caused by noise. ) Remove power supply noise during operation by installing a line filter, etc. in the AC power line. 2) Install this product and its wiring as far as possible from strong electric fields such as those of motors and power lines, etc. ) Make sure to take protective measures against load surge for an induction load (solenoid valves, relays, etc.). 9. Characteristics are limited only to the static state, and when air is consumed on the output side, pressure may fluctuate.. For details on the handling of this product, refer to the instruction manual included with the product.. In locations where the body is exposed to water, dust, etc., there is a possibility that they can enter into the body throught the breathing hole. Use a fitting/tube (M-- fitting and TIU - tube are recommended), extend the piping to the location where there is no water, dust, etc. 2. When using in an enclosed environment, like an inspection box, etc., make sure to install a fan or other such device to prevent from overheating. VY Monitor output voltage White Black Breathing hole M x. 2 4-8-