GAS CHROMATOGRAPHY LGC-A1 SERIES

Similar documents

Agilent 6850 Series II Network GC System G2630A Performance Specifications

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

DANI Transformer Oil Gas Analyzer

S-PRO 3200 GC System for Sulfur Analysis

C2, C3, C4 Monomer Analysis

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

ANTEK APPLICATED Turn-Key GC solutions

GC Instruments GC Columns GC Accessories

Beverage Grade Carbon Dioxide

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

GC Method Compliance and Large Valve Oven Application

Deans Switch Microfluidics

Setting up SilFlow for BackFlush in your GC

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

CP-3800 GAS CHROMATOGRAPH

Closed Cup Flash Point Tester

6890 Installing ¼ Glass Columns

Agilent 7890 Series Gas Chromatograph

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

Using the PSD for Backflushing on the Agilent 8890 GC System

I SO9001 I SO14001 CE

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS

Mistral LC-MS Evolution Specification

performance productivity reliability

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Technical Procedure for Gas Chromatography (GC-FID)

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS

Choose for Your Instrument

Method Development for Capillary GC Systems. Slide 1

Agilent 7693A Automated Liquid Sampler

Application Note. Abstract. Authors. Environmental Analysis

Experience the Difference

Agilent Multimode Inlet for Gas Chromatography

Agilent 7820A Gas Chromatograph

Refrigerated. Centrifuge.

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

Agilent and ASTM. Update on Recent Activities. Page 1

Antek Gas Chromatography Products: A Guided Tour Through Industry

Application. Gas Chromatography June 1995

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. PGC1000 Meeting the needs of NGL plants

29 Installation Step 1. Unpacking the GC Cable diagrams Step 2. Placing the GC system on the benchtop Step 3. Turning the power on

THC Heated FID 3-300A

ii) PC based works station with monitor and printer having below mentioned specifications:

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

INTEREST OF HPTLC FOR FOSSIL DERIVED PRODUCTS ANALYSIS : A SIMPLE APPROACH TO HYDROCARBON GROUP TYPE ANALYSIS

Agilent 6890 Gas Chromatograph

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA

Installing a Purged Packed Inlet

HIGH PRESSURE SUPERCRITICAL CARBON DIOXIDE EFFICIENCY IN REMOVING HYDROCARBON MACHINE COOLANTS FROM METAL COUPONS AND COMPONENTS PARTS

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

HIGH SPEED CENTRIFUGE

Mineral Turpentine Adulterant in Lubricating Oil

SUPPORTING INFORMATION

Installing a Purged Packed (PP) Inlet

Thermo Scientific TRACE GC Ultra Multi-channel gas chromatograph. Performance Beyond Limits

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Analysis of Petroleum Fractions by ASTM D2887

DIONEX ELUENT GENERATOR CARTRIDGE DIONEX EGC 500 K 2 CO 3 HIGH PRESSURE ELECTROLYTIC PH MODIFIER (DIONEX EPM 500) Quick Start

4001 Transesterification of castor oil to ricinoleic acid methyl ester

HIGH SPEED CENTRIFUGE

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Service Manual. Agilent G2350A Atomic Emission Detector. Released: MAY 2000 G2350A AED Service Manual 1

Is there still a need for selective GC detectors?

Agilent 7693A Automated Liquid Sampler

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Stability, Linearity and Repeatability of Nitrogen Determination by Flash Combustion using Argon as Carrier Gas

Status Report of the VIAQ (Vehicle Interior Air Quality) Informal Working Group

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

ASTM D 6730 Detailed Hydrocarbon Analysis

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Thermo Scientific. TRACE GC Ultra UFM. Ultra Fast Module Device Instruction Manual. PN , Revision May 2010

Rosemount Analytical Model 500 Process Gas Chromatograph

GC-101. Testing of Biodiesel Using Gas Chromatography. by Bob Armantrout. Presented at: Local Biodiesel: A Biodiesel Coop Conference

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS

GC Instruments GC Columns GC Accessories

Agilent G3348B Flame Photometric Detector

Transcription:

GAS CHROMATOGRAPHY LGC-A1 SERIES www.labtron.com info@labtron.com

Gas Chromatography LGC-A1 Series Gas chromatography LGC-A10 Gas chromatography system LGC-A10 comes with different detectors and each detector individually controls the temperature of the system. This gas chromatography comes with packed column injectors, split/split less injectors, capillary and cool-on column. It is possible to achieve lower limit of detection using these unique injector system. It gives accurate, high precision control, reliable results. Features 7 steps temperature rising function LCD display to view test parameters Individual temperature controlling detectors Self-diagnosis, keyboard locking function Data storage during power off Different detectors with high stability and sensitivity for selection Stable and speedy program for furnace heating Unique injectors system for detection of lower limit Applications Used in the analysis of oil extraction and refining industry, petrochemical analysis, gas industry and in quality control of medicines, food and chemicals.

Chromatography column type Chromatography column length Chromatography column diameter Temperature operating range Maximum programmed heating speed Programmed temperature steps Temperature setting precision Programmed heating rate Furnace dimension Injectors Detectors FID TCD FPD Capillary and Packed column 100 to 500 mm 0.2 to 0.5 mm Higher than the room temperature of 5 0 C to 450 0 C 120 0 C/min 7 steps 1 0 C 0.1 to 120 0 C/min (increment of 0.1 0 C) 280 300 180 mm LGC-A10 Packed column injectors, split/split less capillary column injectors, cool on-column injectors Following detectors can be selected as per the requirement Maximum temperature control: 400 0 C LOD: 5 10 12 g/s [n-c 16] Linear dynamic range: 10 7 Drift: 5 10-13 A/30 min Noise: 2 10-13 A Maximum temperature control: 400 0 C LOD: 10000 mv.ml/mg [n-c 16] Linear dynamic range: 10 4 Drift: 10 µv/30 min Noise: 20 µa Maximum temperature control: 250 0 C LOD: 2 10-13 g/s (P), 5 10-11 g/s (S Linear dynamic range: 10 3 (P), 10 2 (S) Drift: 4 10-11 A/30min Noise: 2 10-12 A

LGC-A10 ECD NPD PDHID Maximum temperature control: 350 0 C LOD: 1 10-14 g/ml (y-666) Linear dynamic range: 10 4 Drift: 5 µv/30min Noise: 20µA Maximum temperature control: 400 0 C LOD: 5 10-13 g/s (P), 1 10 12 g/s (N) Linear dynamic range: 10 3 (P), 10 3 (N) Drift: 2.5 10-12 A/30min Noise: 4 10-13 A LOD: 5ppb

Gas Chromatography LGC-A1 Series Gas chromatography LGC-A11 Gas chromatography system LGC-A11 is equipped with superior quality, high-precision electronic flow/ pressure control system. This gas chromatograph system has accurate tracking design and accurate programmed heating control system for the furnace temperature. Incorporated with safe and reliable functions of self-ignition and hydrogen leakage self-protection. Features EPC controlled injector flow, column carrier flow and detector gas flow 7 steps temperature rising function LCD display to view test parameters Different detectors with high stability and sensitivity for selection Quick heating and cooling system Gas circuit technology with blowback function Adopted with imported valve configuration system Use of 8 digit auto injector Six individual controlling heating areas Applications Used in quality supervision of medicines, foods and chemicals, oil extraction and refining industry, petrochemical industry, electronic high-purity gas industry and scientific research institutes.

Chromatography column type Chromatography column length Chromatography column diameter Temperature operating range Maximum programmed heating speed Programmed temperature steps Temperature setting precision Programmed heating rate The longest method run time Furnace dimension Heating area Detectors FID TCD FPD Capillary or Packed column 100 to 300 mm 0.2 to 0.5 mm 120 0 C/min 7 steps 0.1 0 C 0.1 to 120 0 C/min (increment of 0.1 0 C) 999.99 min 280 300 180 mm LGC-A11 Higher than the room temperature of 5 0 C to 450 0 C, Liquid nitrogen cold trap: -80 0 C to 400 0 C, Dry ice cold trap: -55 0 C to 400 0 C Six individual controlling heating areas Maximum temperature in auxiliary heating area: 300 0 C Following detectors can be selected as per the requirement Maximum using temperature: 450 0 C Minimum LOD: 2.5 pg C/s [n-c16] Linear dynamic range: 10 7 (±10%) Data collection frequency: Maximum 100 Hz Maximum using temperature: 400 0 C Minimum LOD: <400 pg C3H8 /ml (He) Linear dynamic range: 10 5 (±5%) Data collection frequency: Maximum 100 Hz Maximum using temperature: 250 0 C Minimum LOD: <4 pg S/sec, <1 pg P/sec Linear dynamic range: >10 3 S, >10 4 P Optional: 10 5 g S/g C, 10 6 g P/g C

LGC-A11 ECD Maximum using temperature: 400 0 C Type of gas compensation detector: 5% methane, argon, nitrogen Minimum LOD: >10 7 S, >10 7 P Linear dynamic range: 5 10 5 Data collection frequency: Maximum 100 Hz Radioactive source: <12 m Ci 63Ni NPD Maximum using temperature: 450 0 C Minimum LOD: <0.2 pg N/sec, <0.2 pg P/sec Minimum LOQ: < 3 pg/sec Linear dynamic range: 10 5 N, 10 5 P