XMC0 Series. Definite Purpose Contactors. Description. Features. Type model nomenclature - Ordering Information

Similar documents
Cross reference. Definite Purpose Contactors

4. Heavy duty Silver Metal Oxide contacts to provide long electrical endurance.

2. No tools required for snap-on accessories require that make modification quick and easy.

XMC0 Series DEFINITE PURPOSE CONTACTORS

XMC0 Series. Definite Purpose Contactors

UEW5 series intelligent air circuit breaker

Data Sheet Definite Purpose Contactors Ex9CK Series

30C30 definite purpose contactor

Table of Contents. HCC Contactor Nomenclature

C E R T I F I C A T E O F C O M P L I A N C E

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

AF40... AF96 3-pole contactors Technical data

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

F-Series. Circuit Breaker

F-Series. Circuit Breaker

Definite purpose contactors

Safety Limit Switch

4.1. Definite Purpose Contactors and Starters. Contents

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

HOW TO ORDER SPECIFY AS SHOWN BELOW EXAMPLE #1

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

C E R T I F I C A T E O F C O M P L I A N C E

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Definite Purpose Contactors and Starters

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Prewired position switches FF series

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Safety Limit Switch

ASL09..S 3-pole Contactors - Spring Terminals

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Application Description

Safety Interlock Switches

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

3. Coils shall be of molded construction

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

UMBW-UL489 and UL1077 Listed

Definite Purpose Contactors and Starters

Industrial Contactors CTX 3 3P 185A - 800A

2NC (slow-action) Direct. Model. opening

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

D4GS-N CSM_D4GS-N_DS_E_7_2

BC Mini Contactor VDC

Switches Unlimited Phone: * Fax:

Ordering Information. Text PCB Power Relay G5LE

Page 2-4 Page 2-8. Page Page 2-13

Ktec Contactors and thermal overloads

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Solenoid Locking Safety Switches

Technical Information

Essential equipment for all your requirements

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Bussmann series Quik-Spec Power Module Switch elevator disconnect

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

Definite Purpose Contactors and Starters

B Mini Contactor V Hz

Safety rope switches with reset for emergency stop

Definite Purpose Contactors and Starters

Description. Positive safety relays

4 - Miniature controls

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

General Purpose Relay

AF series contactors (9 2650)

Small Limit Switch D4V

Model Number Structure

Prewired position switches FF series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

UL 508 Non-Fusible Disconnect Switches

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Enclosures. See Section Typical Description

2NC (slow-action) Direct. Model. opening

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Manual Reset Limit Switch

Features and benefits. Normally open, normally closed contact logic

D4BS CSM_D4BS_DS_E_8_4

Definite Purpose Contactors Types DP, DPA, and SYD Class 8910

Micro Contactor MA Series

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Safety switches for hinged doors

JARD by MARS JARD by MARS

Safety-door Switch. Ordering Information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Thermal Overload Relays

Meta Solution. Contactors and Overload relays

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Safety rope switch with reset for emergency stop

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Transcription:

XMC0 Series Definite Purpose Contactors Description HOMER XMC0 series high performance definite purpose contactors (1 pole, 1pole+shunt, pole, pole(optional Auxiliary Contact Blocks or Microswitch Blocks available, from 5A to 90A ) are ideal for (HVAC) air conditioning, refrigeration, heating, data processing, welding, elevators, hoists & cranes, washing machine, lighting, pools & spas and food service equipments. XMC0 series definite purpose contactors meet IEC 609474 1, GB 14048.4 and UL508 standard. Features 1. Toolsfree accessories make quick & easy snap on.. Various terminal optional for specific application.. Universal mounting plate allows an easy replacement other brands. 4. Heavy duty Silver Metal Oxide composition contacts with longer electrical endurance. 5. Coils are Class F (155 ) temperature insulated with wide range of voltages and 50/60Hz ratings. 6. Different with main competitors,our1&p contactors have the options to add coil cover to effectively protect the coil from being damaged by outer force. 7. UL and CCC approved, some models SEMKO, KETI or TÜV plus. Type model nomenclature Ordering Information XM C 0 5. E B B C 0 F Q 1 4 5 6 7 8 9 10 11 1 1 14 15 Number digit 1: Manufacturer s code XM Xiamen Hongmei Electronic Co., Ltd. Number digit : Product Type C Contactor Number digit : Design Sequence Number 0 1

Number digit 4: Full Load Amperes (FLA) 5,, 40, 50, 6, 75 or 90 5 5A A 40 40A 50 50A 6 6A 75 75A 90 90A Number digit 5: Number of Poles 1,,, A, 7 Number digit 5 1 A 7 pole Number of poles 1pole+shunt pole pole 1pole (at p frame) Number digit 6: Coil Voltage E, F, I, L, N Number digit 6 E F I L N Coil voltage 50Hz 4VAC 11010VAC 080VAC 80415VAC 60Hz 4VAC 11010VAC 08VAC 77VAC 440VAC Number digit 7: Mounting plate A, B (B: Normal) A Plastic base(for 540FLA only, not recommend) B Metal plate Number digit 8: Cover A, B (B:Normal) A Long cover(for 540FLA only, not recommend) B Short cover Number digit 9: Terminal A, B, C, D, E, F A Screw w/ quick connect (For 540FLA only) B Sems clamp w/ quick connect (For 540FLA only) C Slotted & Hex head washer w/ quick connect D Box lug w/ quick connect E Box lug w/ quick connect (Line side) Slotted & Hex head washer w/ quick connect (Load side)

F Slotted & Hex head washer w/ quick connect (Line side) Box lug w/ quick connect (Load side) Number digit 10: Auxiliary Contact Blocks or Microswitch Blocks (for pole) (Left & Right) side (SPDT is Microswitch) 0, 1,, 4, 5, 6, 1P, P, 4P, 5P, 6P, L, L1, L, R, R1, R Aux. contact Blocks or Microswitch Blocks on left side Aux. contact Blocks or Microswitch Blocks on right side 0 None (Standard Type) 0 None (Standard Type) 1 1NC+1NO, 0.50 quick connect terminal 1 1NC+1NO, 0.50 quick connect terminal 1NC, 0.50 quick connect terminal 1NC, 0.50 quick connect terminal 4 1NO, 0.50 quick connect terminal 4 1NO, 0.50 quick connect terminal 5 NC, 0.50 quick connect terminal 5 NC, 0.50 quick connect terminal 6 NO, 0.50 quick connect terminal 6 NO, 0.50 quick connect terminal 1P 1NC+1NO, pressure plate screw 1P 1NC+1NO, pressure plate screw P 1NC, pressure plate screw P 1NC, pressure plate screw 4P 1NO, pressure plate screw 4P 1NO, pressure plate screw 5P NC, pressure plate screw 5P NC, pressure plate screw 6P NO, pressure plate screw 6P NO, pressure plate screw L SPDT R SPDT L1 1 SPDT, left side(position 1) of microswitch block R1 1 SPDT, left side(position 1) of microswitch block L 1 SPDT, right side(position ) of microswitch block R 1 SPDT, right side(position ) of microswitch block For example: 4P 1NC pressure plate screws w/ quick connect on left side, 1NO pressure plate screws on right side 56 NC pressure plate screws w/ quick connect on left side, NO pressure plate screws w/ quick connect on right side LR1 SPDT on left side, 1SPDT(position 1) on right side R 1NC pressure plate screws w/ quick connect on left side, 1SPDT(position ) on right side Note: If 00 will be the final digit(s) in selection, omit from model nomenclature. Number digit 11: Coil terminals Blank, F Blank Dual terminals without screws in 1 and pole models and Single terminals with screws in pole models F Dual terminals with screws in pole models Number digit 1: Power quick terminals Blank, G, Q Blank Quad terminals in 1and pole models and Dual terminals in pole models G Without any terminals Q Dual terminals at the side near coil terminal and Quad terminals at the other side in pole 540FLA models

Number digit 1: Nameplate Blank, T Blank Nameplate shows actual product rating T Nameplate shows derated product rating Number digit 14: Contact construction style (for 50/6 FLA) Blank, Z Blank Flat construction in shape Z Bend construction in shape (new design) Number digit 15: Option Customer assigned suffix X where X may be any alphanumeric character or any combined alphanumeric character. Characteristics Conforming to standard IEC6094741, GB14048.4, UL508 Approvals UL(USR/CNR) and CCC Some models SEMKO, KETI or TÜV plus Protective treatment Total climate tropical use TH Operating position Vertical or Horizental (Metal/Plastic base mounting) Ambient operation 5 ~+70 temperature storage 40 ~+70 Relative humidity 9095%RH at 40 Pollution degree Performance XMC0 Poles 1 A 7 Rated insulation voltage V 690 Rated operating voltage V,, (60Hz) or 0,400 (50Hz) Rate current(ac8a) A 5 40 50 6 75 90 Conventional free air thermal current (Ith) A 40 50 6 80 94 10 Full Load Ampere(FLA) A 5 40 50 6 75 90 Resistive Amps Rating(RES) A 5 40 50 6 75 94 10 Switching frequency op/h 60 Electrical endurance(ari 780/790) cycle 00,000 Mechanical life (ARI 780/790) cycle 500,000 4

Pole Characteristics Full Load Amps(FLA)/ Rated operation Amps(AC8a) Poles 5 1 1 40 1 40 1 5 40 5 40 50 6 75 90 Voltage Locked Rotor Amps (LRA) 150 180 150 10 00 150 15 100 180 150 10 00 160 150 15 100 180 150 10 00 160 00 50 00 60 00 450 75 00 540 450 60 Resistive Amps Rating (RES) Conventional free air thermal current(ith) Maximum Horsepower(HP) Voltage Single Phase Three Phase 5 40 40 50 50 50 50 Catalog Number XMC057* XMC051* XMC07* XMC01* XMC0407* XMC0401 XMC0407*H XMC0401*H 5 XMC05* 40 40 XMC0* 50 50 XMC040* 5 40 40 50 50 6 6 75 80 94 94 10 10 5 5 7.5 15 15 5 7.5 10 7.5 10 15 10 15 0 15 0 5 0 5 0 5 40 40 0 50 50 XMC05A* XMC05* XMC0A* XMC0* XMC040A* XMC040* XMC050A* XMC050* XMC06A* XMC06* XMC075A* XMC075* XMC090A* XMC090* Note: All the models also could be marked or used for the actual applications which have less contact ratings than the certificated ratings. The rating can be Voltage, FLA, LRA or RES. 5

Auxiliary contacts block characteristics Conventional thermal current (A) 10 Rated insulation voltage (V) 690 Rated operational current (A) A(AC15) 0/80V /1.9 N(DC1) 110/0V./1.1 Microswitch Blocks characteristics Contact Rating(SPDT) 10A or 11A, 1/ HP, 15 or 50 VAC 1/A, 15 VDC; 1/4A, 50 VDC 4A 10 VAC on Lamp Load Coil characteristics @ 5 (Cold state) Part number Inrushed VA Sealed VA Sealed Watts Voltage 60Hz 50Hz 60Hz 50Hz 60Hz Pickup Dropout XMC0 1/7 40 55 7.5 10 XMC0 45 55 8 10.5.5 XMC0 /A 80 90 1 16 5 XMC050/6 145 160 17.6 7 0.8Us 0.Us XMC075/90 00 5 5 46 1 Notes:Us=4VAC 50/60Hz( E coil) or 10VAC 50/60Hz( F coil) or 0VAC/50Hz, VAC/60Hz( I coil) or 77VAC/60Hz( L coil) or 415VAC/50Hz, VAC/60Hz( N coil). Inrushed VA and Sealed VA test at Us. Dimensions & Wiring diagram 6

7

8

9

10

11

1

1

14

Remarks 1) Torque for Screws 5 lbin/lugs 5 lbin for 540FLA types; Torque for Screws 45 lbin /Lugs 50 lbin for 506FLA types; Torque for Screws 50 lbin /Lugs 60 lbin for 7590FLA types; Torque for Screws 8 lbin for Auxiliary Contact Blocks; Torque for Coil Screws 8 lbin for pole 540FLA types and 1 lbin for 5090FLA types; ) For QC wiring, the female connector should meet IEC60760, necessary to ensure the reliability of connection between female connectors and QC terminals. ) If the actual condition differs from this specification, please contact us for further discussion. 15