inpond 5 in 1 waterfall 6 in 1 DESIGN INNOVATIVE

Similar documents
MINIPOND 700/900 Mk2 THE POND MASTERS GUIDE TO. Blagdon - The Pond Masters The name you can rely on

inpond all-in-one with UVC 1400

inpond 5-in-1 moving water & clarity 300 Congratulations on buying a Pennington 5-in-1.

PRO UVC PRO UVC PRO UVC PRO UVC MOD THE POND MASTERS GUIDE TO. Blagdon - The Pond Masters The name you can rely on

Leaflet Code: AG Filters 2-a. Produced exclusively by. Gravity Filter Aquagarden THE POND MASTERS GUIDE TO GUIDE TO

pond and garden 3 x 1 watt / 5 x 1 watt

Amphibious Pump Leaflet 2.qxd 30/3/06 13:32 Page 1 THE POND MASTERS GUIDE TO AMPHIBIOUS A2500/A3000 A3500/A4000

SUBMERSIBLE WATER PUMPS

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE PUMP HSE RANGE

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

SUBMERSIBLE PUMP HSE RANGE

Mechanical Filter Pump Kit Up to 500 gallons

garden PUMP kit 1 Depth A & B must be less than 9m Max Depth C must be less than 9m Max GardenPump Inst 6/11/07 12:52 Page 1

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE WATER PUMP

INSTALLATION AND USER INSTRUCTIONS

Mechanical Filter Box Kit

SUBMERSIBLE DIRTY WATER PUMP

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

Car Battery Charger Instructions for Use

SUBMERSIBLE WATER PUMP

POND PUMP Model Nos:SPP3 & SPP6 0200

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

WATERFEATURE PUMP HOTLINE 1300 AQUATEC INSTRUCTION MANUAL VERSION JUNE 2016 MODEL 02PV030 - PV650 02PV050 - PV PV075 - PV PV077 - PV3000

Submersible Pond Pump with UV 800 Gallons Per Hour

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

8000 / 10,000 / 12,000

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

Submersible Pond Pump with UV 800 Gallons Per Hour

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Pressurized Pond Filter Up to 850 gallons

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

28W WORK LAMP Model: CTL28 Part No:

12 amp RMS Battery Charger

OPERATION MANUAL SUBMERSIBLE FOUNTAIN PUMP PM2 600LV PM2 900LV PM2 1500LV PM2 2400LV PM2 4500LV

FiberSource Q150. user manual P/N

1 ELECTRIC WATER PUMP

Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

Owners Manual: - Pumps

Complete Pond Kit REMINDER CALL BEFORE RETURNING TO STORE. PLEASE CALL BEFORE RETURNING TO THE STORE.

LED Twister II. User manual UK Version 1.0

Installation manual wall-mounted distributor

OWNER S MANUAL FOR THE PROTECTEAT TEAT SPRAY SYSTEM

MICROFLOCKER. Operating Instructions

PIL0478 ISSUE 01/ 07/16

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

PRO-MAX ULTRAVIOLET STERILIZER

OWNERS MANUAL ECODIVER

ORIGINAL INSTRUCTIONS

SUBMERSIBLE WATER PUMP

Operating Instructions

SUNC3000 / Item #40885

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

Illumifalls Patio Pond

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

MP V 8A Electronic Smart Charger. Instruction and Information Manual

1100W PORTABLE GENERATOR

OPERATION INSTRUCTIONS

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS

Installation manual portable distributors

AQUA2000 From O3PURE

Compact Security FloodLight

1200W INVERTER GENERATOR

Instruction Manual. * We reserve the right to amend specification without prior notice.

Roller Door Operator

Instruction Manual. * We reserve the right to amend specification without prior notice.

OPERATION & MAINTENANCE INSTRUCTIONS

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

200 / 300 Overflow / By-Pass Kits

GARDEN HOSE UTILITY PUMP

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

PRESSURIZED DIATOMACEOUS EARTH FILTER SYSTEM

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Battery Charger JCB-FCH20LI2

Reverse Polarity MANUAL. Surechlor S3500

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

Safety, Installation and Service Manual Models 1952, 1953 & 1972

OPERATION & MAINTENANCE INSTRUCTIONS

SELF PRIMING CHEMICAL SERVICE PUMPS

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

24V DC - 1/2 SQUARE DRIVE IMPACT WRENCH KIT

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Transcription:

Established over 50 years ago, Blagdon are committed to producing a comprehensive range of high quality and easy to use water gardening equipment. We have an on-going programme of research and development that ensures excellent product performance and value for money for our customers. Our products are brought together with half a century of expertise and knowledge so you can be assured of a successful and creative water garden. INNOVATIVE DESIGN inpond 5 in 1 3000 6000 waterfall 6 in 1 9000 Interpet, Vincent Lane, Dorking, Surrey, RH4 3YX Interpet.co.uk Blagdonwatergardening.co.uk Leaflet Code: 26/11/15 www.interpet.co.uk www.blagdonwatergardening.co.uk

CONTENTS inpond 3000 6000 9000 Getting to know your Inpond 3000 Parts Descriptions / spares codes - with exploded diagram Getting to know your Inpond 6000/9000 Parts Descriptions / spares codes - with exploded diagram Pump performance / flow chart Specification chart Installation Electrical Installation Installing Inpond Installing UVC UVC Electrical Installation 2 2,3 & 4 5 5, 6 & 7 7 8 9 9 10, 11, 12, 13, 14 15 18-19 20-21 Congratulations on buying an inpond 5 in1 Manufactured with advanced technology to create a clean and healthy pond for your fish. IMPORTANT Please attach proof of purchase to this manual and file in a safe place. Maintenance and cleaning Cleaning Step by Step guides Routine Maintenance Annual Maintenance Winter storage Troubleshooting Troubleshooting and maximise performance Faults - problem procedure Consumer advice contact details Guarantee 17, 18-23 23-24 18 18 24 24 25 25, 26 & 27 27 28 27 & 28 1

GETTING TO KNOW YOUR INPOND 3000 GETTING TO KNOW YOUR INPOND 3000 1 2 3 4 5 6 7 8 53 12 9 21 10 11 13 47 46 45 44 43 48 49 14 15 16 17 18 19 20 50 44 52 51 50 49 47 46 45 41 40 39 38 31 44 43 54 29 42 37 36 35 34 33 22 23 24 25 26 27 28 30 32 No. Part Description Spare Code 1. Locking Handle N/A 2. Filter Lid N/A 3. Coarse Foam 1051170 4. Medium Foam 1051170 5. Polymer Wool Cartridge N/A 6. Polymer Wool Pad 1051166 7. UVC Viewing Window N/A 8. UVC Contact Chamber Screws N/A 9. UVC Magnet N/A 10. Ceramic Media 1051187 11. Filter Body N/A 12. IPX7 Starter UVC N/A 13. UVC Mains Cable N/A 14. UVC Electronics & Cap N/A 15. UVC Body N/A 16. UVC Quartz Sleeve Yellow Lock Cap N/A 17. UVC O ring N/A 18. UVC Quartz sleeve Holder N/A 19. PL 5w UVC Lamp 1041041 20. 5w Quartz Sleeve N/A 21. Outlet Locking Nut N/A 22. Double threaded attachment N/A 23. 1 1/2" Connecting Pipe N/A 24. Pump Locking Nut N/A 25. 1 1/2" Impellor Cover N/A 26. O ring N/A 27. Impellor Complete 1017800 28. Pump motor unit N/A 29. Low Voltage Transformer N/A 30. Pump Cable Low Voltage N/A 31. Light Level Sensor - Photo Sensor N/A 32. Optional Sensor Cover N/A 33. Automatic LED Spot Light Body N/A 34. Automatic LED Spot Light O ring N/A 35. LED Lamp 0.76w 1051330 36. LED Lamp cover clear N/A 37. LED Lamp Screw Cap N/A 2 3

GETTING TO KNOW YOUR INPOND 3000 GETTING TO KNOW YOUR INPOND 6000 / 9000 No. Part Description Spare Code 38. Ball Joint Connector N/A 39. Ball Joint N/A 40. Ball Joint O ring N/A 41. Extension Pipe Connector N/A 42. 30cm Telescopic Extension pipe N/A 43. Control Valve & Diverter N/A 44. Screw on hosetails 1/2" 12.5mm N/A 45. Daisy 1017763 46. Super Daisy 1017763 47. Water Bell Large 1017763 48. New Fountain Adapter N/A 49. Complete Ball Joint N/A 50. Screw on hosetails 1/2" 12.5mm N/A 51. 1/2" 12.5mm Silicon Hose; not included N/A 52. 1/2" 12.5mm Control Valve hose attachment N/A 53. UVC Contact Chamber N/A 54. 20cm Extension Pipe N/A 1 2 3 4 5 6 53 54 52 51 50 2nd way of connection 53 54 52 50 51 49 55 49 48 47 7 8 56 46 45 30 44 9 12 10 11 43 42 41 40 38 37 31 36 35 34 13 39 33 32 14 24 25 26 27 28 29 15 17 16 18 19 20 21 22 23 4 5

GETTING TO KNOW YOUR INPOND 6000 / 9000 GETTING TO KNOW YOUR INPOND 6000 / 9000 No. Part Description Spare Code 1. Locking Handle N/A 2. Filter Lid N/A 3. Coarse Foam 1051774 4. Medium Foam 1051774 5. Polymer Wool Cartridge N/A 6. Polymer Wool Pad 1051166 7. UVC Viewing Window N/A 8. UVC Contact Chamber Screws N/A 9. UVC Contact Chamber N/A 10. UVC Magnet N/A 11. Ceramic Media N/A 12. IPX7 Starter UVC N/A 13. UVC Mains Cable N/A 14. Filter Body N/A 15. UVC Electronics & Cap N/A 16. UVC O ring N/A 17. UVC Body N/A 18. UVC Quartz Sleeve Yellow Lock Cap N/A 19. UVC Quartz sleeve O ring N/A 20. UVC Quartz sleeve Holder N/A 21. PL 9w UVC Lamp N/A 22. Lamp Rubber Holder N/A 23. 9w Quartz Sleeve N/A 24. 1 1/2" Connecting Pipe N/A 25. Pump Locking Nut N/A 26. 1 1/2" Impellor Cover N/A 27. Pump O ring N/A 28. Inpond 6000 Impellor Complete 1051781 Inpond 9000 Impellor Complete 1050333 29. Inpond 6000 Pump motor unit N/A Inpond 9000 Pump motor unit N/A 30. Inpond 6000 Low Voltage Transformer N/A 31. Pump Cable Low Voltage N/A 32. Light Level Sensor - Photo Sensor N/A 33. Optional Sensor Cover N/A 34. Automatic LED Spot Light Body N/A 35. Automatic LED Spot Light O ring N/A No. Part Description Spare Code 36. LED Lamp 0.76w 1051330 37. LED Lamp cover clear N/A 38. LED Lamp Screw Cap N/A 39. 18.75mm (3/4") Hose Fitting N/A 40. 25mm (1") Hose Fitting N/A 41. 12.5mm (1/2") Hose Fitting N/A 42. Inpond 6000 T-piece N/A Inpond 9000 T-piece N/A 43. T-piece Connector N/A 44. Ball Joint N/A 45. Ball Joint O ring N/A 46. Extension Pipe Connector N/A 47. 30cm Telescopic Extension pipe N/A 48. 20cm Extension pipe N/A 49. Jet Housing N/A 50. Bell Jet N/A 51. Tulip Jet N/A 52. Daisy jet N/A 53. Triple Jet N/A 54. Jet Housing N/A 55. Fountain adapter N/A 56. Complete Ball Joint N/A Pump performance / flow chart 1.5m 79 ltrlhr 200 ltrlhr 835 ltrlhr 1.0m 300 ltrlhr 870 ltrlhr 1626 ltrlhr 0.5m 520 ltrlhr 1250 ltrlhr 2371 ltrlhr 0m 700 ltrlhr 1500 ltrlhr 3000 ltrlhr MODEL 3000 6000 9000 6 7

GETTING TO KNOW YOUR INPOND INSTALLATION Technical data - Pump Pump 3000 6000 9000 Max Flow 700 1500 3000 Max Head 1.25m 1.3m 2.0m Voltage 12V 12V 230V Hertz 50Hz 50Hz 50Hz Weatherproof transformer IP68 IP68 IP68 Approved Approved Approved Approved Cable 10m 10m 10m Watts 10w 26.5w 49.5w Technical data - UVC Pump 3000 6000 9000 Voltage 230 Volt 230 Volt 230 Volt Hertz 50Hz 50Hz 50Hz UVC Lamp 5 Watt 9 Watt 9 Watt Weatherproof transformer IP68 IP68 IP68 Approved Approved Approved Approved Cable 10m 10m 10m The power supply must meet the specification of the product. Inpond Pump The cores in the supply cable are coloured in accordance with the following code: Brown = Live, Blue = Neutral. The electric cable is permanently connected and sealed in the motor body. If the supply cable is damaged the pump must not be used. Do not use the supply cable to lift the pump as this may cause damage. WARNING - All Inpond models must be used with an RCD A Residual Current Device (RCD), also know as the Residual Current Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be nstalled in the supply circuit. A means of disconnection from the supply having a contact separationof at least 3mm in all poles must be incorporated in the fixed wiring. For permanent installations to the mains supply, it is necessary to conform to the regulations of the local electricity authority and this would include the use of a metal or plastic conduit to protect the cable. Specification chart Model & Pond Size Category 3000 STANDARD POND 6000 MEDIUM POND 9000 LARGE POND Deep without fish 3000 ltrs 660 gals 6000 ltrs 1320 gals 9000 ltrs 1980 gals Deep with fish 2000 ltrs 440 gals 4000 ltrs 880 gals 6000 ltrs 1320 gals Shallow with fish 1500 ltrs 330 gals 3000 ltrs 660 gals 4500 ltrs 990 gals Deep with fish in full sun 1500 ltrs 330 gals 3000 ltrs 660 gals 4500 ltrs 990 gals Shallow with fish in full sun 1125 ltrs 247 gals 2250 ltrs 495 gals 3375 ltrs 742 gals Shallow with Koi in full sun 562 ltrs 123 gals 1125 ltrs 247 gals 1687 ltrs 371 gals Filter & Waterfall N/A N/A 14cm (5 5 ) 2685 ltrs 590 gals Fountain, Filter & Waterfall N/A N/A 10cm (3 9 ) 1879 ltrs 413 gals Attention has been drawn to the fact that special rules may exist concerning the installation of your pond pump (i.e. local building regulations). These pumps must not be used in swimming pools, or areas where people are in contact with the water. Always disconnect the mains electricity supply whilst the equipment is being installed, repaired, maintained or handled. Consult a qualified electrician if in any doubt about wiring this product to the main supply. Warning - The Inpond pump is provided with a thermal cut out that temporarily switches off the pump in case of overheating and the pump may automatically restart. 8 9

Locating your Inpond INSTALLATION The Inpond pump and filter should be located on a firm and level basein the pond/water feature in a depth of at least 10cm, but no more than 1.25m for the 3000 model and 1.5m for the 6000/9000 models. Convenient Installation INSTALLATION Installation guide: Inpond 3000 The inpond 5 in 1 can be installed either powering a fountain or feature. Fountain FOUNTAIN OPTION FEATURE OPTION Make sure there is ample cable from the transformer. Place product in desired location. Using the telescopic pipe adjust so the fountain head is above the surface of the pond. Fountain height can now be adjusted, see Adjusting flow control diagram below. See Getting to know your Inpond for parts and descriptions. FOUNTAIN OR WATER FEATURE Inpond 3000 Inpond 6000/9000 Adjusting Flow Control Turn clockwise to increase anti-clockwise to reduce flow. The flow control valve is fitted with a diverter to ensure there is always pond circulation. Bell Fountain Adjust bell by moving head higher for small bell and lower for a wider bell shape. Adjusting Dual Control T Piece and telescopic riser pipe 1. Adjust height by unlocking collar then pushing or pulling 30cm telescopic riser pipe. Optional additional 20cm extensions can be added to increase the height. 2. Outlet Flow Control Valve Supply water features, waterfalls and filters by adding 1 3/4 1/2 fittings and hose. Adjust flow by turning flow control valve. 3. Fountain Flow Control Valve Adjust fountain jet flow by turning flow control valve. 4. Fountain Ball Joint Adjust the collar of the ball joint to enable the extensions to be moved compensating for an uneven pond floor. 1 2 4 3 INPOND INPOND Installation guide: Inpond 6000 The inpond 5 in 1 can be installed either powering a fountain or feature, or both. INPOND, FOUNTAIN AND/OR FEATURE OPTION FOUNTAIN WATER FEATURE HOSE Tip: Ensure that any fountain or feature fitted does not empty water out of pond/water feature. INPOND HOSE 10 11

INSTALLATION Installation guide: Inpond 9000 The waterfall inpond can be installed either powering a fountain, a waterfall or both. Inpond 3000 INSTALLATION INPOND 5 IN 1 RUNS A FOUNTAIN OR FEATURE AND LED SPOTLIGHT FOUNTAIN OPTION FOUNTAIN INPOND WATERFALL OPTION WATER RETURNED TO POND VIA WATERFALL INPOND FOUNTAIN & WATERFALL OPTION Fully adjustable fountain control. Adjusts fountain height and width. 5w UVC lamp LED Spotlight 20 +/- ball joint adjustment to compensate for uneven pond floor 20cm extension pipe 30cm adjustable telescopic extension pipe FOUNTAIN WATER RETURNED TO POND VIA WATERFALL INPOND Water Feature 12 13

INSTALLATION INSTALLATION Inpond 6000 INPOND 5 IN 1 RUNS A FOUNTAIN AND/OR FEATURE AND LED SPOTLIGHT Inpond 9000 TO RUN WATERFALLS/FEATURES AND/OR A FOUNTAIN AND LED SPOTLIGHT 20cm extension pipe LED Spotlight 20 +/- ball joint adjustment to compensate for uneven pond floor Fully adjustable fountain control. Adjusts fountain height and width. 20cm extension pipe LED Spotlight 20 +/- ball joint adjustment to compensate for uneven pond floor Fully adjustable fountain control. Adjusts fountain height and width. 30cm adjustable telescopic extension pipe Interchangeable 1 /25mm, 3/ 4 /19mm, 1/ 2 12.5mm hose fittings 9w UVC lamp Fully adjustable flow control for water feature Hose 30cm adjustable telescopic extension pipe Interchangeable 1 /25mm, 3/ 4 /19mm, 1/ 2 12.5mm hose fittings 9w UVC lamp Fully adjustable flow control for water feature Hose Water Feature or Waterfall 14 15

INSTALLATION MAINTENANCE & CLEANING Waterfall Installation Important The outlet hose should be smooth bore (not corrugated) pipe installed over as short a distance as possible with no kinks or bends. Connecting Outlet Hoses Installing the waterfall or feature 3000 6000/9000 IMPORTANT - Failure to carry out routine maintenance leaving the pump under reduced or no flow conditions for long periods will result in a shorter pump life and will invalidate the guarantee. The Blagdon Inpond 5 in 1 is centrifugal with a magnetic impellor movement driven by a watertight synchronous motor. They require minimum cleaning, only periodic cleaning of the impellor is necessary. Routine Maintenance 1. Switch off electricity 2. Remove Inpond from pond using carry handle (do not use the cables to lift the Inpond) How it works - Flow detail The recommended hose size for your Inpond Filter is stated in the filter performance and specification chart. On Page 8 Always secure with a Jubilee clip Warming the hose in a bucket of boiling water can aid fitting. Use the shortest possible hose lengths to minimise flow restrictions. Avoid folds and kinks in the hose, which will reduce flow and filter performance. To feature or waterfall The water flows through the top of the filter cage down through the filter foams and ceramic media then through the UV chamber ready to exit via the pump. Locking Handle Doubles as a carry handle for easy removal from pond Inlet Grills High surface area, ideal for general pond use Course/Medium Foam Open cell foam in two reducing grades catching dead algae, dirt and waste giving a crystal clear pond. Green Water UV Clarifier Built in light guarantees algae free clear water Safety Switch Built in automatic magnetic safety OFF switch for the UV Automatic LED Spotlight Saving time and money Pump Polymer Wool Pad Cartridge Polishes the water quickly removing particles that create cloudiness Ceramic Biomedia Supports large populations of friendly bacteria, creating a clear and healthy pond 16 17

MAINTENANCE & CLEANING UVC INSTALLATION Opening and locking filter handle Easy lift integrated locking handle Warning - 1) Always turn off the power before any maintenance to the UVC section 2) Always view the UVC lamp through the viewing window on the UVC Chamber 3) Direct exposure to UVC light can damage your eyes and skin. Caution - Inpond UVC has been fitted with a magnetic safety switch. 1) Do not remove unit with power turned on 2) Do not place near strong magnetic fields. UVC Lamps & quartz sleeve maintenance The UVC lamp must be replaced every six months / once a season. It is recommended that the lamp is replaced in the spring. 1. Handle in the locked position 2. Handle is in the central position. This will enable the filter and pump to be carried in and out of the pond. *Ensure the filter is not carried by the pump cable. The Quartz sleeve can become coated in lime scale build up in hard water areas. This should be carefully removed from the quartz sleeve and cleaned with a soft cloth. A wet test must be carried out after maintenance to ensure there are no leaks before the UVC is reconnected. pond/water feature. Wet testing the UVC 3. Close handle down to open position 4. The handle is in the unlocked position allowing the filter media to be removed and cleaned. IMPORTANT - A wet test of the UVC under operating conditions must be carried out before the UVC or electrical supply is installed. Connect the UVC to the Inpond following all installation instructions. After running for 24 hours check for leaks. Testing/replacing the UVC lamp IMPORTANT - Ensure that the mains supply is switched off and the power is isolated before removing the UVC cover. Foams may be cleaned vigorously in a bucket of pond water. Adding Blagdon Bio Start after filter maintenance will help replenish these beneficial bacterial populations and is highly recommended during the first two months of operation when the filter is slowly being colonised. Ceramic bio media These will only need very occasional cleaning (once per year), but must be rinsed in pond water to prevent damaging the beneficial bacteria which help maintain a healthy pond. See Page19 for illustration 1. Unlock the green UVC electronics cap. 2. Inspect the UVC cap and Quartz sleeve for water leaks. 3. Then unlock the yellow quartz sleeve end cap and unplug the lamp to replace if desired 18 19

UVC INSTALLATION UVC ELECTRICAL INSTALLATION 4. If there are no signs of leakage reverse the procedure ensuring that the quartz sleeve O-ring is in place. See alignment diagram. 5 5. Ensure the yellow quartz sleeve cap and the green UVC electronics cap are firmly ser cured by making sure the two looked positions are in direct line of each other. See diagram on page 18, section 5. 6. The unit is protected by a magnetic safety switch that prevents the UVC light from illuminating when the cover is removed even if the power is on. 7. In order to check that the UVC lamp is operating see page 23 on how to view your UVC lamp. ALIGN ARROWS Warning - Direct exposure to UVC light can damage your eyes and skin. Electrical installation - UVC Inpond UVC The cores in the supply cable are coloured in accordance with the following code: Brown = Live, Blue = Neutral. Green / Yellow = Earth In accordance with EN60335-2-109:2010 1 4 3 2 Warning - A Residual Current Device (RCD), also known as the Residual Current Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be installed in the supply circuit. A means of disconnection from the supply having a contact separation of at least 3mm in all poles must be incorporated in the wiring 2 If there has been any damage to the unit please return to the point of purchase for inspection. Important: Please note all electrical work on garden lighting and power installations must comply with part P of the building regulations. Failure to comply is a criminal offence. If the installation of this product is not carried out by a competent electrician who is registered under the Part P self-certification scheme then you must notify the local building control department before work begins. For further information and guidance on this matter and other electrical installations in your home that might be covered by the relevant legislation, contact your local authorities building control department. 20 21

UVC ELECTRICAL INSTALLATION For permanent installations to the mains supply, it is necessary to conform to the regulations of the local electricity authority and this would include the use of a metal or plastic conduit to protect the cable. Attention has been drawn to the fact that special rules may exist concerning the installation of your pond UVC (i.e. local building regulations). This UVC must not be used in swimming pools, or areas where people are in contact with the water. Polymer wool cartridge MAINTENANCE & CLEANING The polymer wool pad may be washed a limited number of times before it starts to lose efficiency and block rapidly. Replacement packs of polymer wool are availible from your retailer and are quick and easy to replace. See page 15 On how to remove the cartridge easiliy from the Inpond. Always disconnect the mains electricity supply whilst the equipment is being installed, repaired, maintained or handled. Consult a qualified electrician if in any doubt about wiring this product to the mains supply. Active hinge Polymer wool cartridge WARNING: Electrical Safety UVC warning: Dangerous Ultra Violet Radiation. The rays from the UVC lamp are harmful to eyes and skin. Always turn off UVC electrical supply before any maintenance. To protect the UVC starter; never immerse in water. Locate the UVC starter (Inpond 3000 part 12 & Inpond 6000/9000 part 11) 1 metre minimum from pond edge. Polymer wool pad Removing led Lamp Replacing or removing the lamp can be easiliy done by unscrewing the lamp screw cap, then the clear cover can come apart. Allowing the LED lamp to be disconnected. See getting to know your Inpond for part descriptions. Pump IMPORTANT - Ensure that the mains supply is switched off and the power isolated before removing the lamp cover. 22 23

LED Automatic Photo Sensor - detects when light levels are low/dusk The LED automatic sensor is positioned on top of the motor body between the outlet and the lamp. Ensure this is kept clean from dirt and algae as it needs sufficent light to activate correctly. MAINTENANCE & CLEANING This extremely effcient lamp uses less than 1 watt of electricity which automatically turns on at dusk and off at dawn. Annual maintenance of the filter Check for wear. Once a year you should dismantle your Inpond. Dismantle the filter examining all the parts for wear or damage, replacing any parts showing obvious signs of wear and/or damage (see getting to know your filter for replacement codes and parts descriptions on pages 2, 3, 4 & 5) Annual maintenance of the pump Check for wear. Once a year you should service your pump. Dismantle pump and examine all parts for wear or damage, replacing any parts that show obvious wear and/or damage (see getting to know your Inpond for parts/description and replacement codes). Particular care should be taken to examine the cable entry points. Annual maintenance of the UVC Check for wear. Once a year you should dismantle your Inpond UVC section. Ensure you have disconnected the mains supply before carrying out any maintenance or cleaning. Dismantle the UVC containing all the parts for wear and damage, replacing any parts that show obvious signs of wear and damage (see getting to know your Inpond for parts/ description and replacement codes). Winter Storage Automatic LED spot light Ball joint LED automatic sensor Pump If the LED light is not required you can permentently remove the lamp. Inpond comes complete with a rubber cover that can be used to keep the LED light on permenantly. See instruction sticker on the pump for more information. The Inpond can be run in the pond during the winter but care should be taken to ensure that it is fully immersed and cannot freeze solid. If the Inpond is not used during the winter follow the annual maintenance procedure and store frost-free in the house or garage until spring. Inpond Filter TROUBLESHOOTING Cloudy/brown water The flow rate / pond turnover is to high or to low. Check that you have correctly calculated the pond volume and that pump flow rate is within limits. The filter is not being supplied with water 24 hours a day. Do not turn off your Inpond. Continuous running is needed to maintain a clean and healthy pond. The filter foam pads are insufficiently blocked to trap the fine waste. Treat with Blagdon Clear Pond treatment. The water is extremely dirty, remove pond waste and leaves - carry out a partial water change. Filter is incorrectly sized - refer to filter performance and specification chart. The filter foams have not been positioned or replaced correctly, ensure that the foams fit tightly within the filter chamber. UVC leaks Check that the UVC O-ring has been correctly assembled. Check that the UVC cap is correctly locked with the yellow quartz sleeve section. Arrows on both caps should be correctly aligned when fitted. See page 16 & 17 on how to correctly install and remove UVC section. Inpond Pump Problem Low flow from pump 1. Follow routine cleaning procedure if no improvement. 2. Follow monthly cleaning procedure. 3. Ensure pipe work is not blocked, leaking or is laid so that it gets crushed or kinked. 4. Keep the height that water is to be pumped from the water surface (called Head) to a minimum. The higher the head the lower the flow rate and the more wear on the pump. 5. Use the largest diameter, smoothest bore pond hose over the shortest distance and keep hose fittings to a minimum. This removes frictional loss of flow and so increases pump flow rates. 24 25

TROUBLESHOOTING TROUBLESHOOTING & IMPORTANT Poor Fountain performance Reduced height. Jets blocked. Clean flow adjusters and fountain head. Wash under a tap or hose. Pond Pump Cleaner should be used to remove lime scale build-up/waste (see diagram) for improved results. DAISY To clean, remove head and rinse. Or in hard water areas, use Pond Pump Cleaner No flow from pump 1. Check power supply is on. 2. Check fuse and wiring (SEE ELECTRICAL INSTALLATION). 3. Follow low flow procedure as above. If none of the above works contact Interpet (Blagdon) Consumer Advice Department (See Faults problem procedure Page 25). Green water Settlement test the water to ensure that there is no sediment suspended in the water. If there is, follow the brown cloudy water troubleshooting guide. In order to check that the UVC lamp is operating: Open the filter unit (see page 15) remove the filter foams and cartridge. Positioned on top of the yellow UVC contact chamber will be a round viewing window where you should see a faint blue light. This operation may need to be carried out at dusk as UVC lamps emit a dim blue light under normal operation. Turning the lamp on and off may aid visual identification. (Ensure the UVC lamp is not more than 6 months old). The UVC may be working effectively but the filter foam/media is too clean and is unable to remove the fine coagulated waste. Treat the pond with Clear Pond and do not clean the foams/media until they are blocked. The filter is too small for the pond, check your filter selection chart. The UVC quartz sleeve is dirty or coated in lime scale. Gently remove the quartz sleeve and clean. Follow all cloudy water trouble shooting points. UVC light not illuminated Check all fuses / RCD and electrical connections follow electrical installation Faults - Problem Procedure Before returning your Inpond to your dealer or contacting our Consumer Advice Department, please carry out the following steps. This will solve most problems quickly and easily. 1. Ensure electrical procedures have been followed fully. Check fuses and any cable connectors/switch boxes. 2. (a) Follow routine maintenance procedure fully. (b) Check location and connecting your pump details including flow rates. (c) Ensure that your pond volume and pump flow rate meet the maximum pond size recommended for the filter model on the filter performance and specification chart. (d) Follow troubleshooting guide. 3. If there is a mechanical breakdown of the filter or UVC, return to the point of purchase for inspection and advice (You will need proof of purchase). Guarantee UV & FILTER This product is guaranteed against defects in material and workmanship for 3 years from the date of purchase, under normal usage. The guarantee DOES NOT APPLY in case of improper use, negligence, lack of maintenace or accidental damage to either the filter or UVC. If the filter or UVC fails due to a manufacturing fault within this period it will be either repaired or replaced free of charge. Liability is limited to replacement of the faulty product only; no other costs will be reimbursed. The guarantee is not transferable and does not affect your statutory rights. This guarantee does not confer any rights other than those expressly set out above. This guarantee does not cover the filter foams or UVC bulb, which will need replacing when worn or every 6 months. If any parts are needed, spares are availible from your retailer. 26 27

IMPORTANT PUMP & LIGHT This product is guaranteed against defects in material and workmanship for 3 years from date of purchase, under normal usage. This guarantee DOES NOT APPLY in case of improper us, negligence, lack of maintenace or accidental damage either to the pump or the impeller shaft. If the pump fails due to a manufacturing fault within this period it will be either repaired or replaced free of charge. Liability is limited to replacement of the faulty product only, no other costs will be reimbursed. The guarantee is not transferable and does not affect your statutory rights. This guarantee does not confer any rights other than those expressly set out above. Excludes the pump impellor & LED lamp which may require replacing annually. If any parts need replacing, spares are availible from your retailer. You can help protect the environment. Please remember to respect the local regulations: hand in the non-working electrical equipments to an appropriate waste disposal centre. inpond 3000 6000 9000 Clearwater Guarantee The Clearwater guarantee will be honoured for 1 year after proof of purchase. Clearwater is guaranteed to a depth of 1m, so that fish are clearly visible. Clearwater is guaranteed provided: You follow all instructions as above. Your filter is within the performance guidelines stated. You consult the Consumer Advice Email and follow any advice to correct the situation. See details below. Refunds can only be authorised by Interpet Blagdon. Consumer Advice contact details Interpet (Blagdon) Consumer Advice Department Interpet, Vincent Lane, Dorking, Surrey RH4 3YX England Telephone: 0845 226 7437 (Monday to Friday 10am to 4pm except Bank Holidays - Time may vary) Fax: 01306 876712 E-mail: customercare@interpet.co.uk Manufactured with advanced technology to create a clean and healthy pond for your fish. IMPORTANT Please attach proof of purchase to this manual and file in a safe place. www.blagdonwatergardening.co.uk www.interpet.co.uk 28