USERS MANUAL MCD REMOTE OPERATOR

Similar documents
Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

MCD Pump Application Module

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10

MCD 200 Series Soft Starters

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

MAKING MODERN LIVING POSSIBLE. Service Manual VLTp Soft Starter - MCD500 *MG17L402*

RVS-DX Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter

1.1 Caution Statements

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Contents. MCD 200 Design Guide. Contents

825-P Modular Protection System for motors Specification Guide

RVS-AX Instruction Manual

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Operating Instructions VLT Soft Starter MCD 500


CTi Automation - Phone: Fax: Web:

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

Application Engineering

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Soft Starter - MCD500

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

AuCom - Soft Starters

DC Variable Speed Drive Panel

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Design Guide. VLT MCD 200 Soft Starter. Phone: Fax: Web: -

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP. Catalog. Edition 03/ / EN

Section 0.0 Warnings... 2 Section 1.0

User Manual Solar Charge Controller 3KW

TRIPS AND FAULT FINDING

HIB Enclosed Inverter User Guide

Section 1.0 Warnings Section 2.0. Section 3.0. Section 4.0. MCD3000 Inside Delta Connection Kits. Contents

Application Engineering

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

J1000 D E F I 1000 J1000 J1000 J1000 J1000

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

GS2 Series - Introduction

HVAC Products. Introducing the SED2 Variable Frequency Drives

Design Guide. VLT Soft Start Controller MCD 100

INTECH Micro 2300-RTD6

AC drive has detected too high a Check loading

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Pocket Guide VLT Soft Starter the single speed drive

PowerOhm Installation Manual for LG ATV Series Braking Modules

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

Low voltage AC drives

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

AUCOM NORTH AMERICA. Complete range of motor starting solutions

PowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter

SAX Electronic Valve Actuator

Application Description

MAKING MODERN LIVING POSSIBLE. Instruction Manual VLT AutomationDrive FC 300

Application Engineering Europe

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

Application example of a motor controlled by MCD100 and protected by a circuit breaker

J1000. Compact Inverter Series.

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

INSTALLATION INSTRUCTIONS

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

SDS Enclosed Star-Delta Starter User Guide

User Guide. Digistart CS. 7.5kW - 110kW (18A - 200A) 200V, 400V, 575V

Reduced Voltage Starters

MATRIX LLC LEVEL CONTROL PANEL

Operating Guide. VLT Soft Starter MCD 600

PowerOhm Installation Manual for BM R Series Braking Modules

PowerOhm Installation Manual for BM R Series Braking Modules

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

Technical Documentation

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

RVS-DN Digital Soft Starter A, V Instruction Manual

BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Open Chassis Star-Delta Starter User Guide

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

RVS-DX Instruction Manual

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

User Manual. Solar Charge Controller 3KW

Operating Instructions. Drives Solutions.

VSD Series II Variable Speed Micro Drives

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

60 Series Engine Controls

Transcription:

USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3 Mounting...3 Connection...3 Grounding and Shielding...3 Termination Resistors...3 For Use with MCD 3000...3 For Use with MCD 200 Series...4 Specifications...5 General Technical Data...5 Dimensions...5 Operation...6 Functionality Range...6 Operation...6 Trip Codes...7 4-20 ma Analogue Output...8 Overview...8 Calibration...8 Programming...8 Programming Procedure...8 Programmable Parameters...8 Troubleshooting...9 General Faults...9 MG.17.E4.02 - VLT is a registered Danfoss trademark 1

Introduction Introduction Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice. Symbols Used in this Manual When reading this manual you will come across different symbols that require special attention. The symbols used are the following: Indicates something to be noted by the reader Use all internationally recognised standard practice for RS485 communications when installing and using this equipment. The information contained in this manual is subject to change at any time and without prior notice. In no event will responsibility or liability be accepted for direct, indirect or consequential damages resulting from the use or application of this equipment. Indicates a general warning Indicates a high voltage warning General Description The Remote Operator allows remote operation of MCD 3000 and MCD 200 Series soft starters, and offers the following functionality: Operational control (Start, Stop, Quick Stop and Reset) Starter status monitoring (Start, Run and Trip) Performance monitoring (motor current and motor temperature) Trip code display 4-20 ma analogue output (motor current) Optional RS485 network connection The Remote Operator can act as a gateway device for connection to an RS485 serial communications network, allowing remote control of a motor from an RS485 network using Modbus RTU or standard AP ASCII communications protocol. For further information, please refer to the Modbus Module Instructions. This manual makes reference to MCD 200, MCD 201, MCD 202 and MCD 203. The MCD 200 designation is used when referring to characteristics common throughout the MCD 201, MCD 202 and MCD 203. In all other cases the text refers to the specific range. 2 MG.17.E4.02 - VLT is a registered Danfoss trademark

Installation This section describes how to install the Remote Operator for basic control and monitoring of a soft starter. The Remote Operator is pre-configured to control a soft starter once control supply power is applied to both devices. For basic operation, no parameter adjustments are required on the Remote Operator or the soft starter. In order to use the Remote Operator's 4-20 ma analogue output to monitor motor current, follow the instructions in the section 4-20 ma Analogue Output on page 8. Connection The Remote Operator requires a minimum of three electrical connections - the external power supply, the chassis earth and the RS485 Starter port to the soft starter. All external wiring, except the chassis earth (M4 stud provided), is connected to spring operated clamp connector terminals with a maximum wire size of 2.5 mm 2. No special tools are required. Once the Remote Operator is mounted, connect it to the starter as illustrated below. Installation Mounting The Remote Operator is rated IP54 or NEMA 12 when mounted correctly in accordance with these instructions. It is intended for use on the flat surface of a panel, with all external wiring connected from behind the panel. The Remote Operator is supplied with a mounting bracket and four fasteners. The built-in gasket seal guarantees protection from outside the panel. Select the panel location of the Remote Operator. The required panel cutout is 92 mm x 92 mm. Place the Remote Operator through the cutout and locate the mounting bracket at the rear of the panel onto the four studs. Use the four fasteners to tighten the mounting bracket up to the rear of the panel. For use on a flat surface of a NEMA 1 or NEMA 12 enclosure. Grounding and Shielding Twisted pair data cable with earth shield is recommended. The cable shield should be connected to a GND device terminal at both ends and one point of the site protective earth. Termination Resistors In long cable runs prone to excessive noise interference, termination resistors should be installed between B1 (-) and B3 (+) of the soft starter and the Remote Operator. This resistance should match the cable impedance (typically 120 Ω). Do not use wire wound resistors. For Use with MCD 3000 To connect the Remote Operator to an MCD 3000 soft starter: MCD 3000 REMOTE OPERATOR Fasteners (x 4) Mounting bracket RS485 SERIAL PORT 4-20 ma RS485 STARTER RS485 NETWORK POWER SUPPLY + GND - + - - GND + - GND + ~/+ ~/- 68 61 69 B10 B11 B1 B2 B3 B6 B7 B8 1 2 177HA375.10 177HA374.11 Universal panel cutout (92 mm x 92 mm) Remote Operator 4-20 ma ANALOGUE OUTPUT (MOTOR CURRENT) SUPPLY VOLTAGE (18 ~ 30 VAC/VDC In order for the Remote Operator to operate correctly, the MCD 3000 must be in Local mode (set Parameter 20 = 2: Local Control Only). MG.17.E4.02 - VLT is a registered Danfoss trademark 3

Installation For Use with MCD 200 Series In order to use the Remote Operator with MCD 200 Series soft starters, a Remote Operator Module must first be installed to the starter using the following steps: For the Remote Operator to operate correctly, a link must be fitted across terminals A1-N2 on the starter. 1. Remove control power and mains supply from the MCD 200. 2. Attach the Remote Operator Module to the side of the MCD 200 as illustrated. 177HA264.10 RS485 Remove control power and mains supply from the soft starter before attaching or removing accessories. Failure to do so may damage the equipment. Once the Remote Operator Module has been installed, wire between the Remote Operator and the module as follows: MCD 200 A1 N2 REMOTE OPERATOR 177HA265.11 REMOTE INTERFACE RS485 4-20 ma RS485 RS485 SERIAL PORT MCD NETWORK + GND - + - - GND + - GND + 68 61 69 B10 B11 B1 B2 B3 B6 B7 B8 POWER SUPPLY ~/ ~/ - 1 2 4-20 ma ANALOGUE OUTPUT (MOTOR CURRENT) SUPPLY VOLTAGE 18 ~ 30 VAC / VDC 4 MG.17.E4.02 - VLT is a registered Danfoss trademark

Specifications General Technical Data Enclosure Front Panel Height... 120 mm Front Panel Width... 120 mm Inside Panel Depth (when mounted)... 30 mm (max) Panel Cutout... 92 mm 2 Weight... 450 g Power Supply Voltage... 18-30 VDC/VAC (50/60 Hz) Consumption... 250 ma (max) Connection (Terminals 1, 2)... 2 pole spring clamp connector terminals RS485 Serial Network Port (Optional) RS485 Network Interface... AP ASCII or Modbus RTU protocol (selectable) Connection (Terminals B6, B7, B8)... 3 pole spring clamp connector terminals RS485 Serial Starter Port (Soft Starter Connection) RS485 Soft Starter Interface... AP ASCII protocol as standard Connection (Terminals B1, B2, B3)... 3 pole spring clamp connector terminals Analogue Output Motor Current Monitoring Interface... 4-20 ma (max burden 200 Ω) Connection (Terminals B10, B11)... 2 pole spring clamp connector terminals Sundry Enclosure Rating... IP54 or NEMA 12 when correctly panel mounted Pollution Degree... Pollution Degree 3 Operating Temperature... - 5 o C / + 60 o C Relative Humidity... 5 to 95% (max non-condensing) This product has been designed as Class A equipment. Use of this product in domestic environments may cause radio interference, in which case the user may be required to employ additional mitigation methods. Standards Approvals CE... IEC 60947-4-2 UL and C-UL... UL 508 C... IEC 60947-4-2 Specifications Dimensions 7.0 177HA266.11 AMPS TEMP CODE START RUN TRIP RS485 120 85.0 START STOP + RESET DATA PROG SOFT STARTER 120 37.5 mm (inch) MG.17.E4.02 - VLT is a registered Danfoss trademark 5

Operation Operation Functionality Range The Remote Operator provides the following range of functions: Description Operational control (Start, Stop, Reset, Quick Stop) Starter status monitoring (Ready, Starting, Running, Stopping, Tripped) Performance monitoring (motor current, motor temperature) Trip code display 4-20 ma analogue output Operation MCD 201 MCD 202 MCD 203 The Remote Operator performs all soft starter functions except programming of the soft starter. The Remote Operator can only be used to program its own parameters. Soft starter parameters must be adjusted locally at the soft starter or through the serial communications network if connected. 177HA325.11 START RUN TRIP RS485 START STOP + Display AMPS TEMP CODE RESET DATA PROG Display Mode Status LEDs MCD 3000 Simultaneously pressing the Stop/+ and Reset/- pushbuttons initiates a quick stop, which immediately removes voltage from the motor, ignoring any soft stop time set on the starter. Feedback Display Mode: Indicates the data type shown on the display: Motor current Motor temperature Trip code Display: Indicates the value of the selected data. Status LEDs: Indicate the status of the starter, and of the RS485 link between the Remote Operator and the starter. The Start LED (Green) indicates that the soft starter is starting, running or stopping. The Run LED (Green) indicates that the soft starter is providing full voltage to the motor. The Trip LED (Red) indicates that the soft starter has tripped. The RS485 Status LED shows the condition of the serial link between the Remote Operator and the soft starter. When this is illuminated the connection is healthy. When the LED is flashing there has been loss of communication. Motor current and motor temperature information is only available from MCD 202 and MCD 3000 starters. If connected to an MCD 201 open loop soft starter or MCD 203 compressor starter, the display will show 2222 instead of motor current and 1.11 instead of motor temperature. SOFT STARTER Start Pushbutton Stop Pushbutton Pushbuttons Data/Prog Pushbutton Reset Pushbutton Start pushbutton: Starts the motor. Stop/+ pushbutton: Stops the motor. Reset/- pushbutton: Resets the starter. Data/Prog pushbutton: Selects the data type to be shown on the display (motor current or motor temperature), or accesses Programming Mode. 6 MG.17.E4.02 - VLT is a registered Danfoss trademark

Trip Codes If the soft starter trips, the CODE and TRIP LEDs illuminate and the relevant trip code is reported on the Remote Operator display. Some trip codes are not available from all starter models - see the table below. Trip Codes If the soft starter has an internal problem indicated by a Code E (EEPROM Read/Write Failure) or Code U (CPU Error) on its display, the soft starter will not communicate with the Remote Operator. The Remote Operator display will show four dashes and the RS485 LED will flash. Code Description MCD 201 MCD 202 MCD 203 MCD 3000 1-0 Shorted SCR 1-1 Excess start time 1-2 Motor overload 1-3 Motor thermistor 1-4 Phase imbalance 1-5 Supply frequency 1-6 Phase rotation 1-7 Instantaneous overcurrent 1-8 Power circuit 1-9 Undercurrent 1-b Bypass overload 1-C Communications failure between module and starter 1-E EEPROM read/write failure 1-F Heatsink overtemperature 1-H Forced communications trip from the network master 1-J Auxiliary trip 1-L FLC out of range 1-P Invalid motor connection 1-U CPU error 1-Y Incorrect main control module MG.17.E4.02 - VLT is a registered Danfoss trademark 7

4-20 ma Analog Output 4-20 ma Analogue Output Overview The Remote Operator has a 4-20 ma analogue output for monitoring motor current. The 4-20 ma output is available on terminals B10, B11. The analogue output signal spans from 4 ma when the motor current is zero (when the soft starter is not running) to 20 ma when the motor current is 125% of the Motor FLC setting in the Remote Operator (Parameter 6). 3. Use the Stop/+ and Reset/- pushbuttons to adjust parameter values. Programming Mode closes when the Data/Prog pushbutton is pressed after Parameter 8. There is a 20 second timeout when the Remote Operator is in Programming Mode. Programming Mode will automatically close if no input is registered for 20 seconds. Any changes already made will be saved. Calibration The 4-20 ma output is available only when the Remote Operator is connected to MCD 3000 or MCD 202 models. The Remote Operator Motor FLC parameter (Parameter 6) must be adjusted to match the Motor FLC setting in the soft starter. The lower end of the analogue output signal can be calibrated using the Remote Operator Analogue Output 4 ma Offset parameter (Parameter 7). This is set to give a 4 ma output signal when the motor current is zero. The 4-20 ma analogue output must only be used for motor current monitoring and metering. It is not designed for process signal control use. Programming The Remote Operator uses only one Motor FLC setting. This function is not suitable for MCD 3000 applications using two parameter sets. When the 4-20 ma output is being used, the Remote Operator's Motor FLC and Analogue Output 4 ma Offset parameters (Parameters 6 and 7) must be set appropriately (see Calibration above). Programming can only be carried out while the soft starter is not running. Programming Procedure 1. To enter Programming Mode, hold down the Data/Prog pushbutton for four seconds. The default value of the first parameter will be displayed. 2. Use the Data/Prog pushbutton to advance to the next parameter. Programmable Parameters Par. No. Description 1 RS485 Network Baud Rate 2 RS485 Network Satellite Address 3 RS485 Network Timeout 4 RS485 Network Protocol 5 Modbus Protocol Parity Default Setting 4 20 0 1 0 Adjustable Range 6 Motor FLC (A) 10 1 to 2868 7 Analogue Output 4 ma Offset (%) 100 80 to 120 8 Start, Stop, Quick Stop function disable 0 0 = Remote Operator start, stop, quick stop function enabled. 1 = Remote Operator start, stop, quick stop function enabled. 2 = Remote Operator start, stop, quick stop function disabled. 3 = Remote Operator start, stop, quick stop function disabled. Parameters 1 to 5 are not relevant for the 4-20 ma output. See the Modbus Module Instructions for details. Remote Operator Reset/- pushbutton is always enabled. 8 MG.17.E4.02 - VLT is a registered Danfoss trademark

Troubleshooting General Faults The Remote Operator Display and Status LEDs can indicate abnormal operating or system conditions. This troubleshooting guide gives details of these conditions. Display Indication Problem Possible Solution No display No control supply voltage Check that correct voltage is present at terminals 1, 2. AMPS or TEMP LED flashing Four dashes on display and RS485 LED flashing Soft starter in restart delay mode The Remote Operator has detected a loss of communication on the RS485 link to the soft starter - Incorrect or no 4-20 ma analogue output signal Wait for the restart delay (programmed in the soft starter) to elapse. Verify and solve the cause for loss of communication. If communication is restored before the soft starter registers a Communications Failure, the display will return to active status and the RS485 LED will illuminate. If communications are restored after the soft starter registers a Communications Failure, the display will indicate a trip code. Use the Reset/- pushbutton to reset the soft starter fault. Check the correct voltage is present at terminals 1, 2. Check that correct polarity is used at terminals B10, B11. Check that the Motor FLC and Analogue Output 4 ma Offset parameters are set correctly. - The motor cannot be started Check that control voltage is connected to the starter. If connected to a MCD 200 starter, check that terminals A1-N2 are linked. Troubleshooting MG.17.E4.02 - VLT is a registered Danfoss trademark 9

Notes 10 MG.17.E4.02 - VLT is a registered Danfoss trademark