INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Similar documents
INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Connection Diagram (48" - 60" Widths) (Front View) Connection Diagram (54" - 66" Widths)

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48" - 60" Widths)

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

ISLAND RANGE HOOD SPECIFICATIONS

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

UNDER CABINET RANGE HOOD SPECIFICATIONS

Viking Installation Guide

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

INSTALLATION INSTRUCTIONS

Viking Installation Guide

! FOR DOMESTIC COOKING ONLY!

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

Pro Island Ventilation Hoods

NUTONE RANGE HOOD NTM SERIES

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE. By Vent-A-Hood

Hood. warning. warning. caution

Type of Motor & Blower

Installation Instructions

Installation Instructions

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

Designer Wall Range Hood Installation. Installation Tutorial Video

FADE Series Wall Axial Fans

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

WhispAire Range Hood Quiet Hood

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

HP190SL Series Slimline Radon Fans

Self-Cleaning Range Hoods

Viking Installation Guide

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25

Installation. Professional Indoor & Outdoor Hoods

www. TheRangeHoodStore.com

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

! FOR DOMESTIC COOKING ONLY!!

Viking Installation Guide

All (-4) Models 390CFM Code Compliant

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

Viking Installation Guide

ceiling & inline/cabinet ventilators

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

CEILING & INLINE/CABINET VENTILATORS

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

WhispAire Range Hood Quiet Hood

brisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number:

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

Installation Guide. Professional Indoor and Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

KEES, INC. BALANCING MANUAL

VENT FLASHINGS GALVANIZED STEEL

Safety & Installation Instructions

Multi-Port Centrifugal Fans for Round Duct

MODERN-AIRE. For the professional or the everyday gourmet, Modern-Aire Ventilating. Range Hoods

Filtered Kitchen Supply Packaged Ventilator

Viking Installation Guide

IMPORTANT SAFETY INSTRUCTIONS

Model ND-2 Specification

VENTING & COMBUSTION AIR GUIDE

SD-1250 and SD-1600 Series Smoke Dampers

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento.

Ceiling and Inline Fans

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

Model U102E ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

ISLAND INSTALLATION WALL INSTALLATION

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

Installation GUIDE. 5 SERIES Professional Indoor Hoods EVWH53048, EVWH53648, EVWH54848

SQUARE INLINE CENTRIFUGAL FANS

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

Transcription:

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including firerated construction. Switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally during installation. B. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. C. Ducted fans must always be vented to the outdoors. D. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local code authorities. E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to a maximum of 15 per 100 square feet of occupiable space, unless a back drafting test is performed or make-up air is provided. Consult a local HVAC engineer for make-up air evaluation. WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK Page 1 C U L R US

Ducting Do s and Don ts General Requirements Observe local codes regarding special duct requirements and placement of duct against combustibles. Using Vent-A-Hood transitions (back page) will ensure proper efficiency. Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. Where possible, seal joints with duct tape. The hood must be ducted to the outdoors without restrictions. Blower Requirements The island dual blower unit (T200) requires round duct or equivalent (50 square inches). Blower Combined Duct Dize Sq. Inch Area Vent-A-Hood Transition Island Dual (T200) 8" round or equivalent 50 sq. in. VP565 (Included) Ducting Requirements NEVER reduce the duct size. When combining ducts together, the square inch area must reflect the total square inch area of the ducts being combined. Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance. Only use smooth, galvanized, metal duct. Make the duct run as short and as straight as possible with as few turns as possible. Avoid sharp-angled turns. Instead, use smooth, gradual turns such as adjustable elbows or 45 degree angled turns. For duct runs over 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree elbow is equal to 5 feet of duct. Termination Requirements Airflow must not be restricted at the end of the duct run. A wall louver or roof jack is required for each duct run. Every wall louver or roof jack must include a gravity damper to prevent back drafts. Do not use screen wire or spring-loaded doors on wall louvers or roof jacks. Do not terminate venting into an attic or chimney. YES Smooth Duct Smooth Gradual Turn Proper Combining of Two Ducts NO Flexible Duct Sharp Angled Turns Page 2 Improper Combining of Two Ducts

Installation Details 1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only. Custom hoods may require additional specification consideration. 2) When installing an island range hood, it is recommended that the bottom edge of the hood be located no more than 30 above the cooking surface for optimum performance. 3) Load-bearing framework in the ceiling is necessary for installation. Additional framework construction may be required. Do not attach an island hood to a structure that cannot support twice the weight of the hood. If applicable, remove the duct cover from its packaging and remove the hood-mounting screws from the base of the duct cover. Install the duct cover to the load-bearing framework in the ceiling using appropriate hardware through the four inside corner mounting flanges on the top of the duct cover. 1 ½ 1 ½ 5 1 Dia. Island Duct Cover Mounting Holes 4) Install the duct(s) from the outside of the home down to the location of the exhaust outlet(s) on the top of the transition plus 1. This will allow the transition to engage 1 inside of the duct. Consult the connection diagrams (on next page) for further details on exhaust outlet placement. Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is listed on the back page of this instruction sheet. Transition height is as follows: Island Dual Blower (T200): round duct connects to 9 tall VP565 transition (included). 5) Prepare a protective surface on the floor or countertop for the hood. Remove the hood from its packaging and place it upside-down on the protective surface for access to the inside of the hood. Page 3

Installation Details Continued 1 Tall Island Connection Diagram (3-54 Widths) Of Hood 8" Round 8" Round Of Hood ¾ 2 1 5 x 1 9" Electrical Transition 550 T200 Dual Blower 5" VP565 Standard Transition (Included) 16" 1 Tall Island Connection Diagram (60-6 Widths) 11" 11" 3" Of Hood 2 1 ¾ 5" x 16" 18" Electrical (2) Of Hood 1100 T2+ 200 Dual Blowers 8" Transition Transition Installed (Side View) 30 Tall Island Connection Diagram (3-54 Widths) 8" Round 8" Round 5 x 1 9" Electrical 6 ½ Transition 550 T200 Dual Blower 5" VP565 Standard Transition (Included) 16" 30 Tall Island Connection Diagram (60-6 Widths) 9" 5 x 1 30" Electrical (2) 6 ½ Transition 1100 T2+ 200 Dual Blowers Transition Installed (Side View) Page 4

Installation Details Continued 6) Remove the shipping tape that is securing the E-Z Clean shields inside the hood. Remove the E-Z Clean shields by lightly pulling each toward the end of the hood. Gently close the back draft dampers from the top side of the hood. To remove the blower housings, unsnap the suitcase latches (one on each side of the housing). The housings should be pulled forward and gently tipped to clear the blower wheels and then out of the hood. Warning: Make sure power is off and locked at the service disconnecting means on the service panel during installation. 7) FOR HOODS WITH REMOVABLE BLOWER MOUNTING ASSEMBLIES ONLY. IF HOOD DOES NOT HAVE A REMOVABLE BLOWER MOUNTING ASSEMBLY, PROCEED DIRECTLY TO STEP 9. Remove each blower deck assembly by removing the 12 screws around the blower mounting plate. Unplug the electrical connector and set the blower assembly aside, taking care not to damage blower wheels. 8) Install an appropriate 1/2 UL listed electrical wire clamp through the electrical strap(s) on the top of the hood deck. Install electrical wiring from the service panel to the hood location for each blower assembly. Consult the connection diagrams (previous page) for further details on electrical placement. Support the hood under the location where it will hang and feed the electrical wire(s) through the wire clamp(s). Tighten the clamp(s). SKIP STEP 9. PROCEED DIRECTLY TO STEP 10. Model Volts Amps* Hz RPM SP@0.0" 9) FOR HOODS WITH NON-REMOVABLE BLOWER MOUNTING ASSEMBLIES ONLY. IF HOOD HAS A REMOVABLE BLOWER MOUNTING ASSEMBLY, PROCEED DIRECTLY TO STEP 10. Remove the three screws retaining each blower motor. Unplug and remove the motors, taking care not to damage the blower wheels. It is not necessary to remove the blower wheels from the motors. Equivalent SP@0.1" SP@0.2" SP@0.3" Minimum Round Duct Size T200 Island Dual 115 2.9 60 1550 550 900 507 471 431 8" (50 in. 2 ) 6.0 * Add 0.5 amp for each halogen light. Because the Magic Lung blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung blower can handle cooking equipment with higher cubic feet per minute () requirements and can deliver equivalent much more efficiently than other than other filtration systems. When comparing the Magic Lung with other blower units made by other manufacturers, use the Equivalent. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. Attach the transition to each dual blower assembly and seal with duct tape. The transition must fit inside the exhaust collar on the blower assembly. Install an appropriate 1/2 UL listed electrical wire clamp through each motor box electrical opening on top of the hood. Install electrical wiring from the service panel to the hood location for each motor box. Consult the connection diagrams (previous page) for further details on electrical placement. Feed the electrical wire(s) through the wire clamp(s). Tighten the clamp(s). SKIP STEP 10. PROCEED DIRECTLY TO STEP 11. Sones # Page 5

Installation Details Continued 10) FOR HOODS WITH REMOVABLE BLOWER MOUNTING ASSEMBLIES ONLY. IF HOOD DOES NOT HAVE A REMOVABLE BLOWER MOUNTING ASSEMBLY, PROCEED DIRECTLY TO STEP 11. Raise the hood to its final position and attach it to the load-bearing framework in the ceiling using appropriate hardware or to the duct cover(s) using the screws previously removed in Step 3. From inside the hood, using UL listed wire nuts, attach the neutral wire(s) to the white lead(s), the hot wire(s) to the black lead(s), and the ground wire(s) to the green lead(s). SKIP STEP 11 AND 12. PROCEED DIRECTLY TO STEP 13. Warning: Do not operate hood without proper ground connection. 11) FOR HOODS WITH NON-REMOVABLE BLOWER MOUNTING ASSEMBLIES ONLY. IF HOOD HAS A REMOVABLE BLOWER MOUNTING ASSEMBLY, PROCEED DIRECTLY TO STEP 12. While taking care to properly align the duct connection between the transition(s) and the duct(s) in the ceiling, raise the hood to its final position and attach it to the load-bearing framework in the ceiling using appropriate hardware or to the duct cover(s) using the screws previously removed in Step 3. 12) From inside the hood, using UL listed wire nuts, attach the neutral wire(s) to the white lead(s), the hot wire(s) to the black lead(s), and the ground wire(s) to the green lead(s). Plug the motors into the hood and reinstall the blower motors using the three retaining screws that were previously removed in Step 9. Note: The side of the motor box where the black motors mount is labeled to ensure the motors are installed back into the hood in the proper position. PROCEED DIRECTLY TO STEP 14. Warning: Do not operate hood without proper ground connection. 13) FOR HOODS WITH REMOVABLE BLOWER MOUNTING ASSEMBLIES ONLY. IF HOOD DOES NOT HAVE A REMOVABLE BLOWER MOUNTING ASSEMBLY, PROCEED DIRECTLY TO STEP 14. Attach the transition(s) to each deck blower assembly and seal with duct tape. The transition must fit inside the exhaust collar on the blower assembly. Reconnect the electrical connector for each blower deck assembly. For assemblies with two connectors, connect the right harness to the front connector and the left harness to the back connector. While taking care to properly align the duct connection between the transition and the duct in the ceiling, reinstall the blower deck assembly into the hood using the 12 screws previously removed in Step 7. 14) Replace the blower housings and the blower shields. Make sure that the dampers open and close smoothly. 15) Refer to Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light functions to ensure they are operating properly. Page 6

VENTING WALL LOUVER WALL LOUVER WALL LOUVER ACCESSORIES RECTANGULAR WALL LOUVER 8 5 Back View 1 ½ Flange Back View 1 ½ Flange 13 13 Back View 1 ½ Flange 8 ½ 1 ½ FLANGE 2 FLANGE VP526 VP527 VP528 Round Round Round (MAXIMUM 4/12 PITCH) VP554 Round (MAXIMUM 4/12 PITCH) VP555 Round (MINIMUM 4/12 PITCH) VP538 VP560 x 8 ½ x (MINIMUM 4/12 PITCH) 6 ½ 22 ½ 10 ½ 6 ½ 22 ½ 10 ½ 20 ¾ 20 ¾ VP539 Round VP540 Round VP541 Round ADJUSTABLE ELBOW VP513-8 ½ VP514-9 9 1 VP515-10 5 VP552 VP553 Round Round BACK/SIDE VENT ELBOW 8 ½ VP539-HP Round VP540-HP Round VP541-HP Round x BACK VENT ELBOW 14 4 ¼ VP552-HP VP553-HP x TO TRANSITION Round Round 7 ½ VP513 Round VP514 Round VP515 Round MULTI-BLOWER TRANSITION Round 1 VP561 to x 8 ½ M1200 STANDARD TRANSITION VP559 x STANDARD ISLAND TRANSITION VP521 x to CLUSTER BLOWER TRANSITION VP562-17 ½ VP563-16 ½ 9 9 11 ¼ VP562-2 VP563-30 ½ VP562 VP563 & to & to 21 VP566 21 x to 1 5 VP565 5 x 1 to 18 ½ VP564 & to OFFSET L & R TRANSITION FOR ISLAND BLOWERS SIDE VENT TRANSITION L & R FOR ISLAND BLOWERS 19 OFFSET KIT - ROUND OFFSET KIT - RECTANGULAR 10 ½ VP542 VP543 5 1 Top Left Top Right VP544 VP545 1 5 Left Side Right Side VP529 1 Rnd to Rnd 1 VP550 Rnd to x Y TRANSITION ROUND DUCT PIPE RECTANGULAR DUCT PIPE RECTANGULAR DUCT PIPE 1 3 30 1 24 8 ½ VP517 VP518 VP551 & to & to & to VP500 VP501 VP502 Round Round Round VP504 VP505 VP506 x x x 1 VP507 x 8 ½ Page 7