MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library

Similar documents
MARINE HIGH PRESSURE CARBON DIOXIDE SYSTEMS Component Sheet Library

INERGEN. 150-BAR SYSTEMS Design, Installation, Recharge, and Maintenance Manual

Component Sheet Library

Instructions for Installation, Operation, Care and Maintenance

ARGONITE Fire Protection Systems

January 2007 Approval Guide Fixed Extinguishing Systems 5-57

HPCO 2. Fire Extinguishing System

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

P99 Pressure Reducing Regulator

Technical Data Sheet SEVO 1230 Clean Agent Cylinders

Automatic Roof Door Vents

Foam Chambers DATA SHEET. Features. Application. Flow Range. Description

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve

Alpha Series Systems

Alpha Series Systems

490 Series Actuators. 490 Series. Contents. Introduction

Features 1. Differential Latch-type, lightweight, dependable

55-Gallon Powder Drum Truck

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Protection Systems. 3-Way Directional Ball Valve P/Ns: X and X. A UTC Fire & Security Company FEATURES

A /20/30, LT-A /20/30 VEHICLE SYSTEMS Installation, Recharge, Inspection, and Maintenance Manual

TECHNICAL DATA 1-1/2 (dn40)

Protection Systems. 3-Way Directional Valve P/N: XX-00X. A UTC Fire & Security Company FEATURES

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Plumbing. Controls, Drains, Piping, Flanges, Couplings, Caps and Plugs

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

TL960 PARTS MANUAL. Fuel Section. Page 9-1. Fuel 09/97

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

COVER PLATES & ROLLERS

P70, P72, and P170 Series Controls for High Pressure Applications

Installation, Operation and Maintenance Manual

Type N550 Snappy Joe Emergency Shutoff Valves

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA CAUTION

P70, P72 and P170 Series Controls for High Pressure Applications

Zone Valves and Parts (Honeywell)

P70, P72, and P170 Controls for Low Pressure Applications

2 YEAR WARRANTY HOSE REELS. reelmaster Series heavy duty, quality hose reel engineered to save space

PIPING TO HAZARD PIPING TO HAZARD AGENT SOURCE AGENT SOURCE TOP VIEW TOP VIEW

DELUGE VALVE DATA SHEET

Distributed By: M&M Control Service, Inc Product Product Code Technical Instructions Page #

PARTS MANUAL. SERIAL NO: to BAND SAWING MACHINE

2500/2700 Series Gas Convection Oven

Worldwide Contacts.

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL

COVER PLATES & ROLLERS

Instructions for Installation, Operation, Care, and Maintenance

HYDROSTATIC TEST SYSTEM MANUAL

Baumann Mikroseal Control Valve

Auxiliary Equipment. Table of Contents. Auxiliary Equipment H-1. Product Product Code Technical Instructions Page #

Lifeline Medical Systems

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Castle Model TSM-35. Heavy Duty Screw Pocket Machine. For Models with Serial Number and Above Items Included with Machine

PARTS LIST GAS TILTING SKILLETS MODELS: ACGTS-30 ACGTS-40

TANK LIDS, REAR STEP AND WHEELS

Delivering Peak Performance. High-pressure liquid and gas flow control solutions for the oil and gas industry s harshest environments

TECHNICAL DATA. Q= C v P S

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

627 Series Pressure Reducing Regulators

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

AGCX Bulletin 519 C/Alfoz de Bricia nº4 P.l. Villalonquéjar Burgos (Spain) Tlfno: PAG 1 de 50

Ball Valves in investment cast stainless 2-way

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

PRESSURE GAUGES DIAL THERMOMETERS PRESSURE & TEMP. SWITCHES PRESSURE & TEMP. TRANSMITTERS PIPES, PIPE FITTINGS & FLANGES

Easy to assemble Available with long or short nut in wide range of styles and sizes 651 MALE ELBOW 5/16 O.D. TUBE 1/8 PIPE MALE CONNECTOR

Vertical Pre-Piped Bladder Tanks with Proportioner

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

Introduction. Installation. Maintenance. Bill of Materials

Table 1. Table 2. Table 3: Toxicology/Environmental FM-200 (UL/FM) 14A-07H SECTION 1 - INTRODUCTION. Agent Physical Properties FM-200

GENERAL PUMPA member of the Interpump Group

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

LAWN SPRINKLER, IRRIGATION PUMP

Cylinder Valve Assembly Series

Mueller Super Centurion 250 Fire Hydrant

Product Information. Brass Manifolds. Version A

ADVANCED FIRE SUPPRESSION TECHNOLOGIES STORED AFFF BULK SYSTEM 150/250/350

CHAPTER III SYSTEM DESIGN

Technical Data. UL Listing is based on the following criteria:

Horizontal Pre-Piped Bladder Tanks with Proportioner

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Instructions for Installation, Operation, Care and Maintenance

A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

Model 802 Center Mount Adapter For New Holland 9030 & TV140 Bi-Directional Tractors PARTS CATALOG

WEIGHT (lb) PART NO WITH ACCESS CONNECTION (ODS) BALL PORT DIAMETER WA WAS

Powers TM Controls VP 656 Powermite Three-way Mixing Valves (Flared Type)

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

Type 644 and 645 Differential Pressure Pump Governors

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

Fisher 644 and 645 Differential Pressure Pump Governors

Design Criteria for CSA Kitchen Suppression Assessments (CKH2 & FEKH2)

DANKO STOCK B DANKO XL SKID UNIT 250 Gallon UPF Defender Poly Tank

Type 289P Pilot-Operated Relief Valve

Marine Carbon Dioxide

Transcription:

MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 / www.ansul.com Copyright 2015 Tyco Fire Products LP. / All rights reserved. / Form No. PN426313-01 Component Sheets

Form No. Pages I. Components 1-1 1-51 Parts List for Ansul Marine INERGEN Systems 1-1 1-4 150-BAR CV-98 Valve/Cylinder Shipping Assembly f-98086-3 1-5 flexible Discharge Bend f-98107-2 1-6 Lever Release Actuator f-98092-4 1-7 Connecting Link f-98105-2 1-8 BLANK PAGE 1-9 Manual Pull Box f-98093-2 1-10a/b Combination Latch and Break Glass Pull Box f-98094-2 1-11 enclosed DOUBLE CABLE PULL Box f-99103-2 1-11.1 Cable with Swaged End FittinG f-98095-2 1-12a/b Corner Pulley f-98096-2 1-13 dual/triple Control Boxes f-98097-2 1-14 remote Cable Pull Equalizer f-98098-2 1-15 Marine Actuation Station Two-SteP f-98101-2 1-16a/b Marine Actuation Station One-SteP f-98102-2 1-17a/b extended DISTANCE MARINE ACTUATION METHOD TWO-STEP F-2005053-2 1-17.1 selector/isolation VALVE PNEUMATIC ACtuation f-2010259-1 1-17.2 Pilot Valve Actuation Adaptor f-98099-3 1-18 stainless Steel Actuation Hose f-98111-2 1-19 1/4 in. Pressure Bleeder Plug and 1/4 in. Vent FittinG f-98106-2 1-20 BLANK PAGE 1-21 BLANK PAGE 1-22 header Vent PluG f-98109-2 1-23 Manifold Relief Valve f-98110-2 1-24 time Delay Assembly f-98104-2 1-25 Check Valves Threaded f-98108-2 1-26a/b Check Valves Flanged f-98128-2 1-27a/b Globe Valves and Controls f-98087-2 1-28a/b selector Valves f-98088-3 1-29a/b Pressure Operated Stackable Actuator f-2001245-2 1-30 BLANK PAGE 1-31a single Mating Flanges f-99065-2 1-32 BLANK PAGE 1-33 Pressure Reducer/Union f-98112-3 1-34 Pressure Reducer/Nipple f-98113-3 1-35

Form No. Pages I. Components (Continued) BLANK PAGE 1-33 Pressure Reducer/Union f-98112-3 1-34 Pressure Reducer/Nipple f-98113-3 1-35 flanged Pressure Reducer f-99067-3 1-36a/b Orifice Plate f-99068-3 1-37 360 Discharge Nozzle f-98114-3 1-38 180 Discharge Nozzle f-98115-3 1-39 Pressure-Operated Siren f-2012070 1-40 Pressure Switch 3Pdt f-2012058 1-41 Pressure Switch DPDT Explosion Proof f-98118-2 1-42 BLANK PAGE 1-43 Pressure TriP f-98120-2 1-44 Cylinder BracketinG f-98116-2 1-45a/b Pressure Test Assembly f-98121-2 1-46 operating Instructions Pull Cable Operation f-98127-2 1-47 warning Plate Inside Room with AlarM f-98125-2 1-48 warning Plate Outside Room without AlarM f-98126-2 1-49 nameplate Main f-98123-2 1-50 nameplate Reserve f-98124-2 1-51

SECTION I U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 4 UL EX-4510 7-14-14 Page 1-1 Components Parts List for Ansul Marine INERGEN Systems Cylinder Shipping Assemblies Part No. 426147 200 cu ft INERGEN Cylinder with CV-98 Valve 426148 250 cu ft INERGEN Cylinder with CV-98 Valve 426149 350 cu ft INERGEN Cylinder with CV-98 Valve 426620 350 cu ft (LC) INERGEN Cylinder with CV-98 Valve 441665 350 cu ft (UN ISO) INERGEN Cylinder with CV-98 Valve 428646 435 cu ft INERGEN Cylinder with CV-98 Valve 426150 435 cu ft (LC) INERGEN Cylinder with CV-98 Valve 441661 435 cu ft (UN ISO) INERGEN Cylinder with CV-98 Valve Actuation Components Part No. 42484 Lever Release 423309 Lever Release 427207 Lever Release 42514 Connecting Link 41527 Type A Break Glass Pull Box 43827 Combination Latch/Break Glass Pull Box 45062 Latch Door Type Pull Box 42329 Type B Combination Latch/Break Glass Pull Box (Watertight) 41542 Mounting Legs for Pull Box 426312 Enclosed Double Cable Pull Box with Microswitch 45515 Corner Pulley Watertight 423250 Corner Pulley Aluminum 40696 Right and Left Hand Pulley Adaptor 42784 Dual/Triple Control Box Short 43166 Dual/Triple Control Box Long 42791 Remote Cable Pull Equalizer Short 43168 Remote Cable Pull Equalizer Long 42104 1/16 in. Pull Cable 50 ft (15.2 m) 42109 1/16 in. Pull Cable 100 ft (30.5 m) 42113 1/16 in. Pull Cable 150 ft (45.7 m) 45333 1/16 in. Cable Clamp 40060 Flared End Fitting 31809 16 in. Stainless Steel Hose 32335 20 in. Stainless Steel Hose 32336 24 in. Stainless Steel Hose 418731 Marine Actuation STA2 Step Actuation Components (Continued) Part No. 42175 1/4 in. Pressure Bleeder 31810 Male Elbow 31811 Male Tee 418359 Flared Tee 1/8 x 1/4 x 1/4 in. (3.18 x 6.35 x 6.35 mm) 32338 Male Straight Adaptor 73236 Pilot Valve Actuation Adaptor 32334 Male Elbow (for pilot valve act. adaptor) 436127 Pneumatic Actuation Line Kit Check Valves Part No. 25627 1/4 in. NPT Check Valve 40860 1/2 in. NPT Check Valve 40852 3/4 in. NPT Check Valve 41470 1 in. NPT Check Valve 41549 1 1/4 in. NPT Check Valve 41463 1 1/2 in. NPT Check Valve 40649 2 in. NPT Check Valve 40656 2 1/2 in. NPT Check Valve 40665 3 in. NPT Check Valve 40794 2 in. Flanged Check Valve 46095 2 1/2 in. Flanged Check Valve 40672 3 in. Flanged Check Valve Time Delays Part No. 54169 30 Second Time Delay 426170 60 Second Time Delay

SECTION I U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-2 Components Parts List for Ansul Marine INERGEN Systems (Continued) Globe Valves and Controls (for Pull Cable or Manual Operation) Part No. 41451 1/2 in. Globe Valve 40276 1/2 in. Sector 40238 1/2 in. Lever, Normally Closed 40248 1/2 in. Lever, Normally Open 41102 3/4 in. Globe Valve 40279 3/4 in. Sector 40239 3/4 in. Lever, Normally Closed 40267 3/4 in. Lever, Normally Open Selector Valves Part No. 427185 1 in. Selector Valve Threaded 427150 2 in. Selector Valve Threaded 57433 3 in. Selector Valve Flanged 57445 4 in. Selector Valve Flanged 180 Discharge Nozzles Part No. 426138 1/4 in. NPT Nozzle 426139 3/8 in. NPT Nozzle 426140 1/2 in. NPT Nozzle 426141 3/4 in. NPT Nozzle 426142 1 in. NPT Nozzle 426143 1 1/4 in. NPT Nozzle 426157 1 1/2 in. NPT Nozzle 426144 2 in. NPT Nozzle 426145 2 1/2 in. NPT Nozzle 426146 3 in. NPT Nozzle Actuation Components for Selector Valves Part No. 427207 Lever Release 428566 Pressure-Operated Stackable Actuator Remote Pressure Actuation Components Part No. 418731 Marine Actuation Station 2 Step 67686 Marine Actuation Station 1 Step 7012 LT-20-L Nitrogen Cartridge 52056 1/2 in. 14 NPT Pipe Plug 360 Discharge Nozzles Part No. 417908 1/4 in. NPT Nozzle 417723 3/8 in. NPT Nozzle 417362 1/2 in. NPT Nozzle 417363 3/4 in. NPT Nozzle 417364 1 in. NPT Nozzle 417365 1 1/4 in. NPT Nozzle 417366 1 1/2 in. NPT Nozzle 426155 2 in. NPT Nozzle 426156 2 1/2 in. NPT Nozzle 426137 3 in. NPT Nozzle

SECTION I U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 1 UL EX-4510 12-18-09 Page 1-3 Components Parts List for Ansul Marine INERGEN Systems (Continued) Nameplates Note: System operating instruction charts are provided to suit each individual system and have part numbers unique to each system. A prefix of S- will identify instruction chart part numbers. Part No. 41942 Nameplate Main 41943 Nameplate Reserve 416265 Warning Plate Inside Room with Alarm 416266 Warning Plate Outside Room without Alarm 41915 Operating Instructions Pull Cable Actuation 41925 Alarm Warning Plate 41927 Entrance Warning Plate 41908 Nameplate (Specify) 432150 Cylinder Actuation Instruction Plate 432151 Selector Valve Actuation Instruction Plate Cylinder Bracketing Components Part No. 45120 200 cu ft Cylinder Strap 45244 200 cu ft Cylinder Channel with Nuts and Bolts 45121 250 cu ft Cylinder Strap 45261 250 cu ft Cylinder Channel with Nuts and Bolts 45122 350 cu ft Cylinder Strap 45245 350 cu ft Cylinder Channel with Nuts and Bolts 427704 435 cu ft Cylinder Strap 427705 435 cu ft Cylinder Channel with Nuts and Bolts 79638 Back Frame Assembly 2 Cylinder 79639 Back Frame Assembly 3 Cylinder 79640 Back Frame Assembly 4 Cylinder 79641 Back Frame Assembly 5 Cylinder 79642 Back Frame Assembly 6 Cylinder 73257 Upright 73553 Single Row or Back-to-Back Row Bracket Foot Left Side 73554 Single Row or Back-to-Back Row Bracket Foot Right Side 73555 Double Row Bracket Foot Left Side 73556 Double Row Bracket Foot Right Side 418508 Center Upright Foot 79413 Connector 73250 10.5 in. Carriage Bolt with Nut 73251 11 in. Carriage Bolt with Nut 73252 12.5 in. Carriage Bolt with Nut 418502 13 in. Carriage Bolt with Nut 73253 21 in. Carriage Bolt with Nut 73254 22 in. Carriage Bolt with Nut 73255 26 in. Carriage Bolt with Nut 418503 27 in. Carriage Bolt with Nut 73091 Cylinder Clamp 2 Cylinders 73092 Cylinder Clamp 3 Cylinders 71683 Weigh Rail Support Single Row 71682 Weigh Rail Support Double Row 71684 Weigh Rail Support Back-to-Back Rows 423027 Bracket Upright Weigh Rail Support Back-to- Back Double Row

SECTION I U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-4 Components Parts List for Ansul Marine INERGEN Systems (Continued) Miscellaneous System Components Part No. 437900 Pressure Switch 3PDT 43241 Pressure Switch DPST-EXP-Proof 05156 Pressure Trip 423923 Pressure Test Assembly 437616 Pressure-Operated Siren 426823 2 1/2 in. Threaded Flanged Pressure Reducer 426824 3 in. Threaded Flanged Pressure Reducer 426825 4 in. Threaded Flanged Pressure Reducer 426847 2 1/2 in. Slip-on Flanged Pressure Reducer 426848 3 in. Slip-on Flanged Pressure Reducer 426849 4 in. Slip-on Flanged Pressure Reducer 426853 2 1/2 in. Weld Neck Flanged Pressure Reducer 426854 3 in. Weld Neck Flanged Pressure Reducer 426855 4 in. Weld Neck Flanged Pressure Reducer 417057 2 1/2 in. NPT Pressure Reducer/Nipple 417058 3 in. NPT Pressure Reducer/Nipple 416677 1/2 in. NPT Pressure Reducer/Union 416678 3/4 in. NPT Pressure Reducer/Union 416679 1 in. NPT Pressure Reducer/Union 416680 1 1/4 in. NPT Pressure Reducer/Union 416681 1 1/2 in. NPT Pressure Reducer/Union 416682 2 in. NPT Pressure Reducer/Union 418095 1/2 in. Replacement Orifice Plate 418096 3/4 in. Replacement Orifice Plate 418097 1 in. Replacement Orifice Plate 418098 1 1/4 in. Replacement Orifice Plate 418099 1 1/2 in. Replacement Orifice Plate 418100 2 in. Replacement Orifice Plate 426984 2 1/2 in. Replacement Orifice Plate 426985 3 in. Replacement Orifice Plate 426986 4 in. Replacement Orifice Plate 426856 2 1/2 in. Threaded Single Mating Flange 426857 3 in. Threaded Single Mating Flange 426858 4 in. Threaded Single Mating Flange 426859 2 1/2 in. Slip-on Single Mating Flange 426860 3 in. Slip-on Single Mating Flange 426861 4 in. Slip-on Single Mating Flange 426862 2 1/2 in. Weld Neck Single Mating Flange 426863 3 in. Weld Neck Single Mating Flange 426864 4 in. Weld Neck Single Mating Flange Miscellaneous System Components (Continued) Part No. 418378 1/2 in. Manifold Relief Valve 40309 Vent Plug 427082 Flexible Discharge Bend 437919 Gasket 42430 Gasket (for previous adaptor design) 426028 Bleed Down Device 42411 Plug for Actuation Port 423923 CV-98 Pressure Tester

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 4 UL EX-4510 7-14-14 Page 1-5a 150-Bar CV-98 Valve/Cylinder Shipping Assembly The cylinder is factory filled with INERGEN agent. A single cylinder may be used or multiple cylinders can be manifolded together to obtain the required quantity of agent for total flooding. The cylinder valve can be actuated automatically, pneumatically, and/or manually with approved valve actuation components. All valves are equipped with an anti-recoil feature. The cylinders are shipped with a maintenance record card and protective shipping cap attached to the threaded neck of each cylinder. This cap entirely encloses and protects the valve while in shipment. The friction loss through the valve (equivalent length) and flexible discharge bend is equal to 38 ft (11.6 m) of 1/2 in. Sch. 40 pipe. Component Material Specification Cylinders DOT Specification Steel 3AA2300 Meets TC3AM176 or TC3AAM176 UN Specification Steel ISO 9809-1 Valve Brass Safety Relief Valve Brass Valve/Cylinder UL Listed (EX-4510) Assembly Shipping Cap Steel Shipping Nominal Cylinder Actual INERGEN Approximate Assembly Size Agent Quantity Weight Dimension A Dimension B Part No. ft3 (m3) ft3 (m3) lb (kg) in. (mm) in. (mm) Shipping Assemblies Red Enamel Paint 426147 200 (DOT/TC) (5.7) 205 (5.8) 128 (58) 52.7 (1339) 8.5 (216) 426148 250 (DOT/TC) (7.1) 266 (7.5) 169 (77) 57.7 (1466) 9.3 (235) 426149* 350 (DOT/TC) (9.9) 355 (10.1) 217 (98) 60.0 (1516) 10.7 (272) 426620* 350 (DOT/TC) (9.9) 355 (10.1) 217 (98) 60.5 (1537) 10.5 (268) 441665 350 (UN) (9.9) 355 (10.1) 217 (98) 60.5 (1537) 10.5 (268) 428646* 435 (DOT/TC) (12.3) 439 (12.4) 260 (118) 66.0 (1676) 11.0 (279) 426150* 435 (DOT/TC) (12.3) 439 (12.4) 260 (118) 67.0 (1702) 11.0 (279) 441661 435 (UN) (12.3) 439 (12.4) 260 (118) 67.0 (1702) 11.0 (279) *These containers are special order: minimum order quantities apply, please call for delivery time. Record Tag Pressure Gauge Cylinder Shipping Cap Valve Shipping Cap Valve Pressure Gauge Fill Inlet Port Safety Relief Valve Height to Outlet Center A B 002251 002252

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 0 UL EX-4510 7-14-14 Page 1-5b CV-98 INERGEN Valve The valve requires no internal maintenance. The valve is sealed closed and must not be disassembled. If there is ever a malfunction of the CV-98 valve, the complete valve must be returned to Tyco Fire Protection Products. Note: Use Flexible Discharge Bend (Part No. 427082) when attaching valve to supply pipe or manifold. One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2014 Tyco Fire Products LP. All rights reserved. Form No. F-98086-04

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-6 Flexible Discharge Bend The valve Flexible Discharge Bend (Part No. 427082) is a 5/8 in. (16 mm) I.D. extra-heavy flexible hose which connects the valve discharge outlet to the fixed piping or header manifold. The discharge bend has a special female thread for connecting to the valve outlet and a male 1/2 in. NPT thread for connecting to the fixed piping or manifold. The discharge bend will withstand a pressure of 9000 psi (620.5 bar). Its flexible connection allows for easy alignment of multiple cylinder banks to fixed piping. Each bend has a built-in check valve that prevents loss of agent should the system discharge while any cylinder is removed. The equivalent length of the valve and hose is equal to 38 ft (11.6 m) of 1/2 in. Sch. 40 pipe. Shipping Assembly Part No. 427082 Flexible discharge bend 437919 Gasket 42430 Gasket (for previous adaptor design) Thread Size/Type Component Material Valve End Manifold End Approvals 5/8 in. Flexible SAE 100 R2 Special to 1/2 in. NPT Male UL Listed (EX-4510) Discharge Bend Hose Type AT mate with CV-98 Valve 18 7/8 IN. (479 mm) FEMALE ADAPTOR (SWIVEL, BRASS) CHECK WASHER SWAGE ON 1/2 IN. NPT MALE COUPLING VALVE END MANIFOLD END 000658 Note: The figures below identify the previous and current adaptor designs and required gasket part numbers. Previous Adaptor Design (Required Gasket Part No. 42430) New Adaptor Design (Required Gasket Part No. 437919) One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98107-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 4 UL EX-4510 4-16-12 Page 1-7 Lever Release Actuator The manual lever release actuator provides a manual means of actuating cylinder valves and selector valves. This can be accomplished by direct manual actuation of its pull lever or cable actuation when used in conjunction with a remote manual pull station. When used with a remote manual pull station, the pull station must contain the components necessary to meet the actuator lever traveling requirements of 7 in. (178 mm). The actuator is shipped with ring pin and chain attached. If the ring pin is not required, it must be removed. Failure to remove the ring pin/chain assembly will prevent system actuation if a remote cable pull actuation system is employed and the ring pin is accidentally installed in the actuator. Two actuators are available. Each is designed for a specific component. Component Materials Approvals All Manual Brass and UL Listed Cable-pull Stainless Steel (EX-4510) Actuators Shipping Assembly Part No. 423309 Lever Release (1 1/8-18 mounting thread) Mounts directly to a CV-98 electric actuator. Mounts directly to a CV-98 cylinder valve. 427207 Lever Release (1 1/8-18 mounting thread) Mounts directly to the 1 in., 2 in., 3 in., and 4 in. selector valves. Mounts directly to Pressure-Operated Stackable Actuator (Part No. 428566). Actuator has the handle painted red. PIN 3 7/8 IN.* (98 mm) 3 7/8 IN. (98 mm) 000897 DEPTH: 3 7/8 IN. (98 mm) * Add 1 9/16 in. (40 mm) to height when lever is in the straight up position. One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98092-04

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-8 Connecting Link The connecting link is used to connect two lever releases together when two pilot cylinders are required for actuation. The connecting link can be used on lever releases installed on CV-98 ANSUL valves. One size connecting link is available for all size cylinders. Shipping Assembly Part No. 42514 Connecting link for CV-98 lever release actuator Component Material Paint Connecting Link Steel Red Enamel PIVOT PIN FLEXLOCK HEX NUT 2 5/16 IN. (59 mm) 14 1/4 IN. (362 mm) 3/4 IN. (19 mm) 007978 001885 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98105-02

THIS PAGE INTENTIONALLY LEFT BLANK System Components U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-9

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-10a Manual Pull Box The pull box on an INERGEN system is used to provide mechanical release of the system from a manually operated remote station. Two types of pull boxes are available. The latched door type has a solid cast brass door which must be opened to reach the pull handle. The second type has a break glass window and a spring mounted handle which rotates forward for use when the glass is broken. A 3/8 in. female NPT opening is provided at the back of each enclosure for connection of the cable housing. Both types are painted red. A pulley elbow may be attached directly to the back of the pull box, if necessary, to provide immediate changes in pull cable direction. With this option, the pull box can be extended an additional 3 1/2 in. (89 mm) from the mounting surface by using support legs attached to the back of the pull box (one set for latched door type, two sets for breakglass type). Component Material Approvals Latch door Brass UL Listed (EX-4510) pull box (painted red) Break glass Brass UL Listed (EX-4510) window pull (painted red) box Support legs Brass UL Listed (EX-4510) (painted red) Shipping Assembly Part No. 45062 Latch door type pull box 41527 Break-glass window pull box 41542 Support legs Manual Pull Box Latched Door Type (Part No. 45062) LEAD AND WIRE SEAL BROKEN SIMULTANEOUSLY WHEN KNOB IS PULLED MOISTURE-PROOF JOINT KNOB TO OPEN PULL BOX DOOR HINGED DOOR (CAST BRONZE PAINTED RED) 4 3/16 IN. (106 mm) 3/8 IN. NPT STAINLESS STEEL PULL CABLE PULL HANDLE (BRASS) FOR FIRE OPEN DOOR PULL HANDLE HARD 4 1/8 IN. (104 mm) 3/8 IN. PIPE FOR ENCLOSING PULL CABLE BODY (CAST BRONZE PAINTED RED) 000684b 1 7/16 IN. (36 mm) 1 15/16 IN. (49 mm) 000684a

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-10b Manual Pull Box Break Glass Type A (Part No. 41527) 2 13/16 IN. (71 mm) 4 7/16 IN. (112 mm) 3 1/4 IN. (83 mm) PROTECTED HAZARD ENGRAVED IN NAMEPLATE (SPECIFY) 4 3/16 IN. MOUNTING HOLES SPRING FORCES HANDLE OUT INTO OPERATING POSITION WHEN GLASS IS BROKEN 3/8 IN. PIPE TO ENCLOSE PULL CABLE MOISTURE PROOF JOINT PULL HANDLE GLASS FRONT 3 IN. (76 mm) 4 7/8 IN. (123 mm) 3/8 IN. STAINLESS STEEL PULL CABLE STOWAGE SPACE FOR SPARE BREAK GLASS CAST BRASS HINGED COVER (PAINTED RED) IN CASE OF FIRE BREAK GLASS AND PULL HANDLE HARD UNTIL RED PAINT MARK ON CABLE SHOWS CAST BRASS BODY (PAINTED RED) 000676a BRASS HAMMER AND CHAIN SECURED TO BOX 000676b One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98093-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-11 Combination Latch and Break Glass Pull Box The pull box on an INERGEN system provides mechanical release of the system or directional valve from a manually operated remote station. To operate, release both latches and open the door. Break the glass with the hammer attached to side of box. When the glass is broken, a spring rotates the handle forward for a straight pull. Component Material Approvals Latch-type Brass UL Listed pull box (painted red) (EX-4510) Watertight latch- Brass UL Listed type pull box (painted red) (EX-4510) Shipping Assembly Part No. 43827 Latch type pull box 42329 Type B Latch type pull box (watertight) 3 1/8 IN. (79 mm) 6 3/4 IN. (171 mm) 3 1/4 IN. (83 mm) SPRING FORCES HANDLE OUT INTO OPERATING POSITION WHEN GLASS IS BROKEN MOISTURE PROOF JOINT LEVER TYPE LATCH PROTECTED HAZARD ENGRAVED IN NAMEPLATE (SPECIFY) 3/8 IN. CONDUIT TO ENCLOSE PULL CABLE 1/8 IN. STAINLESS STEEL PULL CABLE STOWAGE SPACE FOR SPARE BREAK GLASS PULL HANDLE GLASS FRONT CAST BRASS HINGED COVER O RING GASKET CAST BRASS HINGED FRONT WITH GLASS IN CASE OF FIRE RELEASE LATCHES, OPEN DOOR, BREAK GLASS AND PULL HANDLE HARD UNTIL RED PAINT MARK ON CABLE SHOWS 3 IN. (76 mm) 4 7/8 IN. (124 mm) CAST BRASS BODY (PAINTED RED) DRAIN HOLE 4 9/32 IN. DIAMETER MOUNTING HOLES BRASS HAMMER AND CHAIN SECURED TO BOX 000680 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98094-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-11.1 Enclosed Double Cable Pull Box with Microswitch The double pull box on an INERGEN system provides mechanical release of the pilot cylinders and the directional valve from a manually operated remote station. To reach the pull handles, release the cover latch and open the door. When the door opens, the microswitch activates the system alarm and system indicators or devices. Pull the CYLIN- DER RELEASE handle to open the pilot cylinders. Pull the VALVE RELEASE handle to open the selector valve to the protected space. Shipping Assembly Part No. 426312 Enclosed Double Cable Pull Box with Microswitch Component Material Approvals Double Pull Box Steel Cable Pull Brass Enclosed Assembly UL Listed (EX-4510) Part No. 426312 18 NPT 12 IN. (305 mm) 13 IN. (330 mm) SIDE VIEW OF CABLE PULL 004201 3 IN. (76 mm) 10 IN. (254 mm) INSIDE VIEW SHOWING CABLE PULLS AND MICROSWITCH 6 IN. (152 mm) DEEP One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-99103-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-12a Cable with Swaged End Fitting The 1/16 in. (2 mm) diameter cable is used to attach remote manual pull boxes to cylinder valves, pull equalizers and control boxes. The cable is constructed of stranded, stainless steel wire. The cable is available in lengths of 50, 100, and 150, (15.2, 30.5, and 45.7 m). The cable assemblies include a brass swaged end fitting for attaching to the remote pull box. The cable clamp is used to create a loop in the wire rope for attachment of the wire rope to a lever release actuator. The Flared End Fitting provides a smooth transition on the end of a pipe run for the pull cable. When the wire rope exits the pipe to connect to lever actuators on pilot cylinders, selector valves, or globe valves the fitting prevents chaffing of the wire rope due to sharp edges on the end of the pipe. Use the flared end fitting on pipe ends any time the wire rope extends beyond the piping. Shipping Assembly Part No. 42104 50 ft (15.2 m) 1/16 in. (2 mm) cable with swaged end fitting 42109 100 ft (30.5 m) 1/16 in. (2 mm) cable with swaged end fitting 42113 150 ft (45.7 m) 1/16 in. (2 mm) cable with swaged end fitting 45333 1/16 in. (2 mm) cable clamp 40060 Flared End Fitting Component Material Approvals Cable Stainless Steel Swaged Fitting Brass Cable Assembly UL Listed (EX-4510) SLOT IN COUPLING FOR INSTALLATION OF CABLE END FITTING HANDLE CABLE END (BRASS) 000689a COUPLING STAINLESS STEEL CABLE WITH SWAGED CABLE END FOR PULL BOX, CABLE END HAVING RED PAINT MARK 000689b Note: The strength of the end fitting exceeds the breaking point of the cable.

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-12b Cable Clamp (Part No. 45333) 1/2 IN. (13 mm) CABLE CLAMP 1/16 IN. CABLE 1/2 IN. (13 mm) 000693 ALLEN HEAD SET SCREW 1/4 IN. (6 mm) Flared End Fitting (Part No. 40060) 1 IN. (25 mm) 7/8 IN. HEX (22 mm) 3/8 IN. STANDARD PIPE THREAD 27/64 IN. (11 mm) 000691 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98095-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-13 Corner Pulley The corner pulley is required on an INERGEN system whenever a mechanical release pull cable run involves a change in direction. Corner pulleys are installed as part of the cable housing (pipe) and provide 90 direction changes with minimal force loss and no induced kinking. The corner pulley is made of forged brass and is threaded for 3/8 in. NPT pipe. The pulley is watertight and is designed for location inside or outside the protected space. Thread adaptors are available to simplify the installation. Forged Brass Watertight Corner Pulley, Sheave Type (Part No. 45515) 2 11/16 IN. (17 mm) 3/8 IN. NPT 1 5/32 IN. (29 mm) Thread Component Material Size/Type Approvals Corner Brass 3/8 in. NPT UL Listed Pulley (EX-4510) Shipping Assembly Part No. 45515 Brass corner pulley (brass wheel) 40696 Thread adaptor right/left hand (brass pulley only) 3/8 IN. PIPE REMOVABLE FACE FOR RUNNING CABLE 4 3/16 IN. (106 mm) LEAD-CLAD COPPER GASKET ADAPTOR 000690b 000690a One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98096-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-14 Dual/Triple Control Boxes The dual/triple control boxes allow manual actuation of a cylinder valve from two or three remote pull stations. Two styles of control boxes are available. Part No. 42784 is 13 3/4 in. (349 mm) and Part No. 43166 is 20 3/4 in. (527 mm) long. Both styles can be used for cylinder valve actuation. Only the longest control box (Part No. 43166) can be used for valves utilizing sectors (globe valves). The inlet and outlet connections are threaded for 3/8 in. pipe. Shipping Assembly Part No. 42784 Dual/triple control box (short) 43166 Dual/triple control box (long) Component Material Thread Size/Type Approvals Control Box (short) Steel 3/8 in. NPT Female UL Listed (EX-4510) Control Box (long) Steel 3/8 in. NPT Female UL Listed (EX-4510) Short Control Box (Shown without cover) (Part No. 42784) 13 3/4 IN. (349 mm) (OVERALL) REMOVABLE COVER CABLE PULL TO CYLINDER RELEASE 3/8 IN. PIPE 4 9/32 IN. (71 mm) MOUNTING HOLES 12 1/4 IN. (311 mm) CABLE CLAMP FLEXIBLE TRANSPARENT PROTECTION RING CLAMP WITHIN BLACK AREA 000685a DIRECTION OF PULL CABLE PULL FROM PULL-BOXES 1 IN. (25 mm) 2 3/4 IN. (69 mm) 3 1/4 IN. (82 mm) 5/8 IN. (15 mm) 1/2 IN. (12 mm) 11/16 IN. (17 mm) 1 7/8 IN. (47 mm) 000685b End View Long Control Box (Shown without cover) (Part No. 43166) 20 3/4 IN. (527 mm) REMOVABLE COVER CABLE PULL TO CYLINDER RELEASE 3/8 IN. PIPE 4 9/32 IN. (71 mm) MOUNTING HOLES 19 1/4 IN. (488 mm) CABLE CLAMP FLEXIBLE TRANSPARENT PROTECTION RING CLAMP WITHIN BLACK AREA 000685a DIRECTION OF PULL CABLE PULL FROM PULL-BOXES 1 IN. (25 mm) 2 3/4 IN. (69 mm) 3 1/4 IN. (82 mm) 5/8 IN. (15 mm) 1/2 IN. (12 mm) 11/16 IN. (17 mm) 1 7/8 IN. (47 mm) 000685b End View One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98097-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-15 Remote Cable Pull Equalizer The remote cable pull equalizer is used in systems where manual actuation of the cylinder valve and operation of a selector valve must be accomplished at the same time. The pull equalizer is mounted in the remote pull station cable line. By pulling the remote pull box, the cable attached to the pull equalizer will pull the internal cable clamp in the pull equalizer which in turn will pull the cables attached to the cylinder valve and selector valve, causing them to operate. Two styles of pull equalizers are available. Part No. 42791 is 13 3/4 in. (349 mm) long and Part No. 43168 is 20 3/4 in. (527 mm). Only the longest equalizer (Part No. 43168) can be used for valves utilizing sectors. The inlet and outlet connections are threaded for 3/8 in. pipe. Shipping Assembly Part No. 42791 Remote cable pull equalizer (short) 43168 Remote cable pull equalizer (long) Component Material Thread Size/Type Approvals Pull Equalizer (short) Steel 3/8 in. NPT Female UL Listed (EX-4510) Pull Equalizer (long) Steel 3/8 in. NPT Female UL Listed (EX-4510) Short Equalizer Box (Shown Without Cover) (Part No. 42791) 13 3/4 IN. (349 mm) (OVERALL) 12 1/4 IN. (311 mm) REMOVABLE COVER CABLE CLAMP DIRECTION OF PULL 1 7/8 IN. (47 mm) 11/16 IN. (17 mm) CABLE FROM CYLINDER AND VALVE RELEASES 4 9/32 IN. (71 mm) MOUNTING HOLES FLEXIBLE TRANSPARENT PROTECTION RING 001844a 3/8 IN. PIPE CABLE TO PULL BOX End View 1 IN. (25 mm) 2 3/4 IN. (69 mm) 3 1/4 IN. (82 mm) 001844b Long Equalizer Box (Shown Without Cover) (Part No. 43168) 20 3/4 IN. (527 mm) (OVERALL) 19 1/4 IN. (488 mm) REMOVABLE COVER CABLE CLAMP DIRECTION OF PULL 1 7/8 IN. (47 mm) 11/16 IN. (17 mm) CABLE FROM CYLINDER AND VALVE RELEASES 4 9/32 IN. (71 mm) MOUNTING HOLES FLEXIBLE TRANSPARENT PROTECTION RING 001844a 3/8 IN. PIPE CABLE TO PULL BOX End View 1 IN. (25 mm) 2 3/4 IN. (69 mm) 3 1/4 IN. (82 mm) 001844b One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98098-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-16a Marine Actuation Station Two Step (S.O.L.A.S.) The marine actuation station is used to release the system pilot cylinders by means of compressed nitrogen gas. This is accomplished by pulling the operating handle marked CYLINDER RELEASE which punctures the nitrogen cartridge, allowing the gas to flow to a pilot port located on the pilot cylinders, and pulling the operating handle marked VALVE RELEASE which punctures the nitrogen cartridge, allowing the gas to flow to a pressure operated selector valve. The marine actuation station comes equipped with 1/4 in. stainless steel compression fittings for attaching 1/4 in. OD stainless steel tubing. The enclosure is rainproof, constructed of 16 ga. galvanized steel and is equipped with a draw pull catch. Actuation pressure is achieved by means of an LT-20-L Nitrogen cartridge (Part No. 7012). Shipping Assembly Part No. 418731 Marine Actuation Station Two Step 7012 LT-20-L Nitrogen Cartridge Component Material Approvals Marine Actuation Steel UL Listed Station Two Step (EX-4510) INSTRUCTION CHART TO VALVE V A L V E R E L C Y L I N D E R R E L 13 IN. (330 mm) PULL CATCH 6 IN. (152 mm) 12 IN. (305 mm) NITROGEN CARTRIDGE COMPRESSION FITTING FOR 1/4 IN. OD S.S. TUBE 10 IN. (254 mm) TO CYLINDER 3 IN. (76 mm) 000694

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-16b MAXIMUM LENGTH RUN (FEET) 0 50 100 150 200 250 300 0.020 58 WALL THICKNESS (INCHES) 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.028 0.035 67 0.049 94 150 0.060 0.065 0.065 1/4 IN. STAINLESS STEEL TUBE 0.070 MAXIMUM LENGTH OF ACTUATION TUBING FROM REMOTE STATION TO CYLINDERS 001382 Note: Pressure Bleeder Plug (Part No. 42175) must be utilized in actuation line of pilot cylinder valve. One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98101-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-17a Marine Actuation Station One Step The marine actuation station is used to release the system pilot cylinders, or the INERGEN tank valve directly, should the system be installed in a space of 6,000 ft 3 (170 m 3 ) or less. Actuation is accomplished simply by pulling on the handle which allows pressurized nitrogen flow through 1/4 in. OD S.S. tube to a pressure actuator located on the carbon dioxide valve. The marine actuation station comes equipped with a 1/4 in. stainless steel compression fitting for attaching 1/4 in. OD stainless steel tube. The enclosure is 16 ga. galvanized steel, rainproof, and equipped with a draw pull catch. Actuation pressure is achieved by means of an LT-20-L nitrogen cartridge (Part No. 7012). Shipping Assembly Part No. 67686 Marine Actuation Station One Step 7012 LT-20-L Nitrogen Cartridge Component Material Approvals Marine Actuation Steel UL Listed Station One Step (EX-4510) INSTRUCTION CHART TO ACTUATE FIRE SUPPRESSION SYSTEM, PULL HANDLE PULL STATION 6 IN. (152 mm) 13 IN. (330 mm) 12 IN. (305 mm) COMPRESSION FITTING FOR 1/4 IN. O.D. S.S. TUBE NITROGEN CARTRIDGE 10 IN. (254 mm) 3 IN. (76 mm) 000695

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-17b 0.020 MAXIMUM LENGTH RUN (FEET) 0 50 100 150 200 250 300 WALL THICKNESS (INCHES) 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.028 0.035 58 67 0.049 94 150 0.060 0.065 0.065 1/4 IN. STAINLESS STEEL TUBE 0.070 MAXIMUM LENGTH OF ACTUATION TUBING FROM REMOTE STATION TO CYLINDERS 001382 Note: Pressure Bleeder Plug (Part No. 42175) must be utilized in actuation line of pilot cylinder valve. One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98102-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-17.1 Extended Distance Marine Actuation Method Two Step (Utilizing 200 cu ft INERGEN Cylinders) The extended distance marine actuation method is used to release the system pilot cylinders and open the selector valve by means of INERGEN agent when the distance between pilot cylinder/selector valve and the remote actuation location exceeds the limits of the marine actuation station. Actuation is accomplished by pulling the lever of each manual actuator located on top of each cylinder valve. One cylinder should be piped to the pilot cylinder valve and the other cylinder should be piped to the pressure operated selector valve. Utilizing a 200 cu ft INERGEN cylinder*, piped through 1/4 in. stainless steel tubing (0.028 in. minimum wall thickness), the maximum length of tubing allowed is 600 ft (182.9 m). See Page 1-18 for connection at the pilot cylinders. Instruction plates are available for mounting next to each cylinder. LEVER RELEASE ACTUATOR(S) TO PILOT CYLINDER 1/2 IN. NPT MALE THREAD BRACKET COMPONENTS TO SELECTOR VALVE** FLEXIBLE DISCHARGE BEND(S) Quantity Part No. 2 426147 200 cu ft INERGEN Cylinder Shipping Assembly* 2 427082 Flexible Discharge Bend 2 423309 Lever Release Actuator 2 79638 Back Frame Assembly (2 Cylinder) 2 73251 11 in. (279 mm) Carriage Bolt with Nut 2 73091 Cylinder Clamp (2 Cylinder) 200 CU FT INERGEN CYLINDER(S)* 006626 Note: Flexible discharge bend outlet is 1/2 in. NPT male thread. Adaptor (sup plied by others) must be used to connect to 1/4 in. stainless steel tube fitting. *Note: Alternate 250 cu ft INERGEN cylinders, Part No. 426148 can be used in place of the 200 cu ft cylinders. **Note: When connecting the pneumatic actuation line from 200 or 250 cu ft Extended Distance Marine Actuation Cylinders, a Bleeder Plug (Part No. 42175) should be installed in the pneumatic line near the stop or selector valve. One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-2005053-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 1 UL EX-4510 4-16-12 Page 1-17.2 Selector/Isolation Valve Pneumatic Actuation The selector valves and 3/4 in. isolation valve can be pneumatically actuated by the Marine Actuation Station. Use the Selector Valve Pneumatic Actuation Line Kit to control the pressure in the actuation line. One Selector Valve Pneumatic Actuation Line Kit is required for each pneumatic actuator and must be installed within 1 ft (0.3 m) of the pneumatic actuator/isolation valve. The Low Pressure Vent Plug and Safety Relief Valve are to be installed with a torque of 125 in.-lb (14 Nm). After system discharge, all pressure in the actuation line must be relieved by pulling the ring on the safety relief valve. Part No. 428566 Pressure Operated Stackable Actuator* 41702 3/4 in. Pressure Operated Isolation Valve 436127 Selector Valve Pneumatic Actuation Line Kit (Kit includes Low Pressure Vent Plug (Part No. 436085), Safety Relief Valve (Part No. 15677), 1/4 in. Close Nipple (Part No. 28484), and 1/4 in. Tee (Part No. 27350)) *Note: The Pressure Operated Stackable Actuator is only required on selector valves. SELECTOR VALVE PNEUMATIC ACTUATION LINE KIT (PART NO. 436127) PRESSURE OPERATED STACKABLE ACTUATOR (PART NO. 428566) TO MARINE ACTUATION STATION FOR ʻVALVE RELEASEʼ 008204 THE ACTUATION LINE KIT IS USED ONLY WHEN BEING PRESSURIZED FROM AN LT-20 CARTRIDGE OF A REMOTE MANUAL STATION. WHEN CONNECTED TO 200 OR 250 CU FT EXTENDED DISTANCE ACTUATION CYLINDERS, USE A BLEEDER PLUG (PART NO. 42175) IN PLACE OF THE ACTUATION LINE KIT. 1 IN., 2 IN., 3 IN., OR 4 IN. SELECTOR VALVE (4 IN. SHOWN) SELECTOR VALVE PNEUMATIC ACTUATION LINE KIT (PART NO. 436127) SAFETY RELIEF VALVE 008334 TO MARINE ACTUATION STATION 4 3/4 IN. (121 mm) LOW PRESSURE VENT PLUG 1/4 IN. TEE 1/4 IN. CLOSE NIPPLE 3/4 IN. PRESSURE ACTUATED ISOLATION VALVE (PART NO. 41702) 008246 1 3/4 IN. (44 mm) One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-2010259-01

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-18 Pilot Valve Actuation Adaptor The Pilot Valve Actuation Adaptor and fittings are used in large INERGEN systems requiring more than one pilot cylinder. This is required in systems where, because of the size of the union orifice, low manifold pressure can be produced which is not high enough to adequately operate the remaining cylinders on the manifold. To overcome this, additional pilot cylinders, pneumatically operated through the pilot actuation port, are required. Refer to system design to determine if additional pilot cylinders are required in the system. Note: Systems comprising three or more cylinders must use a minimum of two pilot cylinders. Shipping Assembly Part No. 73236 Pilot valve actuator adaptor 32334 Male elbow 418359 Flared tee Component Material Approvals Pilot valve Brass UL Listed (EX-4510) actuator adaptor Male elbow Brass UL Listed (EX-4510) Flared tee Brass UL Listed (EX-4510) 1/4 IN. CHECK VALVE (PART NO. 25627) TO MARINE ACTUATION STATION STRAIGHT ADAPTOR (PART NO. 32338) (OR ELBOW, PART NO. 31810) ADAPTOR (PART NO. 73236) (TYP.) MALE ELBOW (PART NO. 32334) (TYP.) TEE (PART NO. 418359) (TYP.) 16 IN. STAINLESS STEEL HOSE (PART NO. 31809) (TYP.) 003636 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98099-03

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-19 Stainless Steel Actuation Hose The Stainless Steel Actuation Hose is used to connect the actuation line compression tees between each agent tank. The hose has the same thread, 7/16-20, as the compression tees. The actuation hose allows flexibility between the rigid actuation piping and the tank valve. 24 IN. (610 mm) Shipping Assembly Part No. 31809 16 in. (406 mm) Stainless Steel Hose 32335 20 in. (508 mm) Stainless Steel Hose 32336 24 in. (609 mm) Stainless Steel Hose 7/16-20 7/16-20 000433 Component Material Thread Size Approvals Stainless Steel Stainless Steel Female 7/16-20 UL Listed (EX-4510) Hose (Both ends) Additional actuation fittings are available: Part No. 31810 Male Elbow (7/16-20 x 1/4 in. NPT) 31811 Male Tee (7/16-20 x 7/16-20 x 1/4 in. NPT) 32338 Male Straight Connector (7/16-20 x 1/4 in. NPT) 418359 Flared Tee (7/16 20 x 7/16 20 x 1/8 in. NPT) 73236 Pilot Valve Actuation Adaptor 32334 Male Elbow (7/16 20 Flare x 1/8 in. NPT) One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98111-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-20 1/4 in. Pressure Bleeder Plug The pressure bleeder plug can be used to relieve the pressure in closed actuation lines. The plug relieves the pressure through a small orifice. This slow relief of pressure does not affect the function of the actuation line. Shipping Assembly Part No. 42175 Pressure Bleeder Plug CAUTION Pressure Bleeder Plug (Part No. 42175) must not be installed anywhere in the directional/selector valve actuation line as the directional/selector valve may not remain open during a complete system discharge, potentially interfering with the ability of the system to suppress a fire. Component Material Thread Size/Type Approvals Pressure Bleeder Plug Brass 1/4 in. NPT Male UL Listed (EX-4510) 1/4 in. Pressure Bleeder Plug 3/8 IN. (9.5 mm) ORIFICE 1/4 IN. NPT 3/4 IN. (19 mm) 001839 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98106-02

THIS PAGE INTENTIONALLY LEFT BLANK System Components U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-21

THIS PAGE INTENTIONALLY LEFT BLANK System Components U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 1 UL EX-4510 4-16-12 Page 1-22

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-23 Header Vent Plug The header vent plug is used to release low pressure buildup that may occur in a closed system utilizing selector valves or check valves. The header vent plug should also be installed on the cylinder sides of the check valves on both main and reserve systems to relieve any pressure that may leak past the check valve and accidentally actuate the reserve system while the main system is discharging. Closing pressure is 30 psi (2.1 bar). Shipping Assembly Part No. 40309 Header vent plug CAUTION A header vent plug must be installed in all closed sections of the system manifold(s). The omission of a header vent plug may cause the manifold to build pressure. This could result in the actuation of a system cylinder, which would then cause all cylinders in that specific system to actuate. Component Material Thread Size/Type Approvals Vent Plug Body: Brass 1/2 in. NPT Male UL Listed (EX-4510) Spring: Seal: Bronze Neoprene STEM SPRING BODY CHECK SEAL WASHER CHECK CUP 7/8 IN. (22 mm) 29/32 IN. (23 mm) 1/2 IN. NPT 000707 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98109-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-24 1/2 in. Manifold Relief Valve The manifold relief valve will release pressure buildup in the manifold line. This slow release of pressure does not affect the function of the manifold line. Burst Pressure: 2,900 3,360 psi (200 232 bar) Shipping Assembly Part No. 418378 1/2 in. manifold relief valve 1/2 in. Manifold Relief Valve SAFETY DISK NUT Component Material Approvals 1/2 in. Manifold Brass UL Listed Relief Valve (EX-4510) 1 1/2 IN. (38 mm) 1/2 14 NPT 7/8 IN. (22 mm) 002740 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98110-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-25 Time Delay Assembly In some applications, the system discharge must be delayed for a short time following actuation. This is usually in areas where it is necessary to evacuate personnel prior to discharge. A manual release is incorporated on the time delay valve to allow instant override of the time delay. The length of delay is factory set and is not adjustable. The time delay assembly uses INERGEN pressure to power the factory-set delay mechanism. Install the assembly in the discharge piping, either directly after the control (pilot) cylinder or further along the piping. The assembly is reversible to accommodate right and left hand configurations and will operate in any mounting orientation. After the discharge is complete, pressure in the assembly slowly returns to normal and closes the time delay valve. Shipping Assembly Part No. 426170 60 Second time delay 54169 30 Second time delay Component Material Approvals Valve Brass Accumulator Steel (Sch. 80 Pipe) Time Delay UL Listed (EX-4510) Assembly 3/4 IN. 14 NPT BOTH SIDES 5 7/8 IN. (149 mm) 5 1/2 IN. (140 mm) 23 3/8 IN. (594 mm) 000699 CROSS SECTION OF VALVE 004372 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98104-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-26a Check Valves Threaded Check valves are used in main/reserve and selector valve systems. On main/reserve systems, the check valve prevents pressurization of the reserve system manifold by blocking the flow of INERGEN agent from the main system to the reserve system. The check valve allows gas flow from the reserve (if actuated) to pass through into the distribution piping. On selector valve systems, the check valve prevents the cylinders from the selected hazard from pressurizing the manifold of the cylinders required for protecting a separate hazard. Only the cylinders needed for the particular hazard are activated. The threaded check valves are available in sizes from 1/4 in. through 2 1/2 in. A BONNET SPRING CHECK DIRECTION OF FLOW B BODY 002737 Shipping Assembly Part No. 25627 1/4 in. check valve (pkg. of 2) 40860 1/2 in. check valve 40852 3/4 in. check valve 41470 1 in. check valve 41549 1 1/4 in. check valve 41463 1 1/2 in. check valve 40649 2 in. check valve 40656 2 1/2 in. check valve 1/4 in. Check Valve (Part No. 25627) Length:1 5/8 in. (41 mm) Width: 3/4 in. (19 mm) Height: 1 1/8 in. (27 mm) ARROW INDICATES DIRECTION OF FLOW 1/4 IN. 18 NPT FEMALE (BOTH ENDS) 000899 Check Valve Threaded Dimension A Dimension B Equivalent Length Valve Size in. (mm) in. (mm) Weight (Sch. 80 Pipe) 1/2 in. 3 (76) 2 5/8 (66) 2 lb (0.9 kg) 12.0 ft (3.7 m) 3/4 in. 3 5/8 (92) 3 1/8 (79) 4 lb (1.8 kg) 24.0 ft (7.3 m) 1 in. 4 1/8 (104) 3 3/4 (95) 7 lb (3 kg) 28.0 ft (8.5 m) 1 1/4 in. 5 (127) 4 1/2 (114) 10 lb (8.7 kg) 43.0 ft (13.1 m) 1 1/2 in. 5 1/2 (139) 5 1/8 (130) 13 lb (5.9 kg) 51.0 ft (15.5 m) 2 in. 6 1/2 (165) 6 7/16 (164) 15 lb (6.8 kg) 48.0 ft (14.6 m) 2 1/2 in. 8 (203) 6 3/4 (171) 34 lb (15.4 kg) 60.0 ft (18.3 m)

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-26b 2 1/2 in. Check Valve (Part No. 40656) B DIRECTION OF FLOW A 002739 Component Material Thread Size/Type Body Type Approvals Check Valve Brass 1/4 18 NPT Female Threaded UL Listed (EX-4510) Check Valve Bronze 1/2-14 NPT Female Threaded UL Listed (EX-4510) Check Valve Bronze 3/4-14 NPT Female Threaded UL Listed (EX-4510) Check Valve Bronze 1-11 1/2 NPT Female Threaded UL Listed (EX-4510) Check Valve Bronze 1 1/4-11 1/2 NPT Female Threaded UL Listed (EX-4510) Check Valve Bronze 1 1/2-11 1/2 NPT Female Threaded UL Listed (EX-4510) Check Valve Bronze 2-11 1/2 NPT Female Threaded UL Listed (EX-4510) Check Valve Bronze 2 1/2-8 NPT Female Threaded UL Listed (EX-4510) One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98108-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-27a Check Valves Flanged Check valves are used in main/reserve systems and on systems protecting multiple hazards of different volumes using selector valves to control the direction of agent flow. On main/reserve systems the check valve prevents pressurization of the reserve system manifold by blocking the flow of INERGEN from the main system. The check valve allows gas flow from the reserve (if actuated) to pass through into the distribution piping. On selector valve systems, the check valve prevents the cylinders from the selected hazard from pressurizing the manifold of the cylinders required for protecting a separate hazard. Only the cylinders needed for the particular hazard are activated. The weld neck flange style valves are supplied with two (2) 600 lb weld neck, flat faced, forged steel flanges, complete with bolts, nuts and gaskets. Threaded flanges with bolts, nuts, and gaskets are included with the 3 in. threaded flange valve. Component Material Thread Size/Type Body Type Approvals Check Valve Body: Bronze N/A 2 in. Weld UL Listed (EX-4510) Flange: Steel Neck Flange Check Valve Body: Bronze N/A 2 1/2 in. UL Listed (EX-4510) Flange: Steel Weld Neck Check Valve Body: Bronze N/A 3 in. Weld UL Listed (EX-4510) Flange: Steel Neck Flange Check Valve Body: Bronze 3 in. NPT Threaded UL Listed (EX-4510) Flange: Steel Flange Shipping Assembly Part No. Weight Equivalent Length 40794 2 in. check valve weld neck flange 40 lb (18 kg) 48 ft (14.6 m) 46095 2 1/2 in. check valve weld neck flange 45 lb (20 kg) 60 ft (18.3 m) 40672 3 in. check valve weld neck flange 125 lb (57 kg) 154 ft (46.9 m) 40665 3 in. check valve threaded flange 125 lb (75 kg) 154 ft (46.9 m)

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-27b Weld Neck Flange A Check Valve Weld Neck Flange Dimension A Dimension B Valve Size in. (mm) in. (mm) 2 in. 10 1/4 (260) 7 1/2 (191) 2 1/2 in. 10 3/4 (273) 8 11/16 (221) 3 in. 11 1/2 (292) 9 1/2 (241) B 000683 3 in. Threaded Flange Check Valve Threaded Flange B A BONNET SPRING Valve Dimension A Dimension B Dimension C Size in. (mm) in. (mm) in. (mm) 3 in. 11 1/2 (292) 15 (381) 9 1/2 (241) INLET OUTLET C CHECK BODY 001817 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98128-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-28a Globe Valves and Controls Globe valves are used to either manually control the flow of INERGEN agent into a hazard area or to manually control the flow into one of several hazards being protected by a common bank of INERGEN cylinders. These valves are operated manually, either by the use of a hand lever attached directly to the valve or by means of a remote manual pull box which will operate a sector attached to the valve. Globe valves can be used as a safety feature, keeping the flow of INERGEN from entering a hazard area, either because of a false discharge or to allow the occupants enough time to exit the area prior to the valve being manually opened. The valves are available in 1/2 in. and 3/4 in. sizes. Each size can be used with a hand lever or a sector. Component Material Thread Size/Type Approvals Globe Valve Forged Brass 1/2 in. NPT Female UL Listed (EX-4510) Globe Valve Forged Brass 3/4 in. NPT Female UL Listed (EX-4510) Shipping Assembly Part No. 41451 1/2 in. direction/stop valve (valve only) 41102 3/4 in. direction/stop valve (valve only) 40248 Handle normally open (for use with 1/2 in. valve) 40267 Handle normally open (for use with 3/4 in. valve) 40238 Handle normally closed (for use with 1/2 in. valve) 40239 Handle normally closed (for use with 3/4 in. valve) 40276 Sector (for use with 1/2 in. valve) 40279 Sector (for use with 3/4 in. valve)

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-28b C* D PIPE HANDLE IN OPEN POSITION HANDLE IN NORMALLY CLOSED POSITION B E 001427b A 001427a *THIS DIMENSION WITH VALVE IN OPEN POSITION A B C D E Valve Size in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) 1/2 in. 10 (254) 9 3/8 (238) 4 3/4 (121) 7/8 (22) 2 15/16 (74) 3/4 in. 14 (355) 12 3/4 (323) 5 5/8 (142) 1 1/8 (28) 3 5/8 (92) 4 3/4 IN. (121 mm) 1/2 IN. STAINLESS STEEL OR MONEL CABLE TO PULL BOX A 3/4 IN. FLARED END FITTING 7 11/16 IN. (195 mm) CABLE TO HAVE A SLIGHT SLACK WHEN VALVE IS IN CLOSED POSITION CABLE CLAMP 3 3/8 IN. (85 mm) B C D ATTACH CABLE IN FIGURE 8 (LOOP) BEFORE FASTENING CLAMP 6 13/16 IN. (173 mm) 000674b 30 PROVIDE A STOP FOR SECTOR AT THIS POINT 000674a A B C D Valve Size in. (mm) in. (mm) in. (mm) in. (mm) 1/2 in. 4 3/4 (121) 3 (76) 7/8 (22) 2 15/16 (74) 3/4 in. 5 5/8 (142) 3 5/8 (93) 1 1/8 (28) 3 5/8 (92) One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98087-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-29a Selector Valves Selector valves are used to direct the flow of INERGEN into the protected space(s). Every valve must have a lever actuator installed to it. Valves can be operated either pneumatically, manually, or by means of a remote cable pull station. When pneumatic actuation is required, a Stackable Actuator Assembly (Part No. 428566) must be ordered separately. Selector valves can be manually operated by mounting a lever actuator directly onto the valve. See Lever Release Actuator Component Sheet for correct actuator. Note: The Selector Valve Adaptor (Part No. 430832) can also be used to retrofit older model 1/2 in. through 2 1/2 in. selector valves (Part Nos. 57428-57433) when used in conjunction with Lever Release (Part No. 427207) and the Pressure-Operated Stackable Actuator (Part No. 428566). Component Material Thread Size/Type Approvals Equivalent Length (Sch. 80 Pipe) 1 in. Selector Valve Bronze 1 in. NPT Female UL (EX-4510) 1/2 in. 1.9 ft (0.6 m) (Used for 1/2 in., 3/4 in. 6.4 ft (1.9 m) 3/4 in. and 1 in. 1 in. 10.4 ft (3.2 m) pipe sizes) 2 in. Selector Valve Bronze 2 in. NPT Female UL (EX-4510) 1 1/4 in. 16.2 ft (4.9 m) (Used for 1 1/4 in., 1 1/2 in. 22.4 ft (6.8 m) 1 1/2 in. and 2 in. 2 in. 67.4 ft (20.5 m) pipe sizes) 3 in. Selector Valve Ductile 3 in. Flange UL (EX-4510) 2 in. 17 ft (5.2 m) Iron American Standard 2 1/2 in. 43 ft (13.1 m) Raised Face 3 in. 78 ft (23.8 m) 4 in. Selector Valve Ductile 4 in. Flange UL (EX-4510) 4 in. 111 ft (33.8 m) Iron American Standard Raised Face Shipping Assembly Part No. 427185 1 in. selector valve threaded 427150 2 in. selector valve threaded 57433 2, 2 1/2, 3 in. selector valve flanged 57445 4 in. selector valve flanged 428566 Pressure-operated stackable actuator

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-29b Note: A lever actuator or brass cap must be used with each selector valve. Valve will not operate properly without one of these on top of pressure actuator assembly. 1 1/8 18 UNEF 1 1/8-18 UNEF D D C C IF FLANGED A B 3 IN. AND 4 IN. FLANGED VALVE 007399 A 1 IN. AND 2 IN. THREADED VALVE 006035 A B C D Valve Size Body in. (mm) in. (mm) in. (mm) in. (mm) 1 in. Threaded 5 1/2 (140) 2 9/16 (67) 7 (178) 1 in. NPT female 2 in. Threaded 7 1/2 (191) 3 1/2 (89) 8 9/16 (218) 2 in. NPT female 3 in. Flanged 3 in. 13 (330) 5 3/4 (146) 6 1/8 (156) 15 (381) 4 in. Flanged 4 in. 16 (406) 5 3/4 (146) 8 3/4 (222) 17 3/16 (437) One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98088-03

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-30 Pressure-Operated Stackable Actuator The Pressure-Operated Stackable Actuator (Part No. 428566) is necessary when pneumatic actuation is required on any selector valve. This actuator is installed on top of the selector valve and a 1/4 in. pressure line must be attached to the 1/8 in. pressure port on the side of the actuator. The actuator must be manually reset. Installations which utilize the pressure-operated stackable actuator must incorporate a Selector Valve Pneumatic Actuation Line Kit (Part No. 436127) in the directional/ selector valve actuation line for each actuator. See Component Page 1-17.2 for kit details. 2.309 IN. (59 mm) 1 1/8 18 UNEF 2.926 IN. (74 mm) 1/8 IN. PRESSURE PORT 006036 1 1/8 18 UNEF One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-2001245-02

THIS PAGE INTENTIONALLY LEFT BLANK System Components U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-31a

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-32 Single Mating Flanges Single mating flanges are available for field assembly to the ANSUL selector valves and the ANSUL flanged pressure reducers. These single, flanged shipping assemblies are available in threaded, slip-on, and weld neck, in 2 1/2, 3, and 4 in. sizes. Each shipping assembly includes a flange, a stainless steel gasket, 8 bolts, and 8 nuts. Shipping Assembly Part No. 426856 2 1/2 in. Threaded Flange 426857 3 in. Threaded Flange 426858 4 in. Threaded Flange 426859 2 1/2 in. Slip on Flange 426860 3 in. Slip-on Flange 426861 4 in. Slip-on Flange 426862 2 1/2 in. Weld Neck 426863 3 in. Weld Neck 426864 4 in. Weld Neck Component Material Approvals Flange Forged Steel UL Listed (EX-4510) Flange Gasket Stainless Steel Bolts/Nuts Plated Steel, Grade 5 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-99065-02

THIS PAGE INTENTIONALLY LEFT BLANK System Components U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-33

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-34 Pressure Reducer/Union The pressure reducer/union is required to restrict the flow of INERGEN agent thus reducing the agent pressure down stream of the union. The 3000 psi (206.9 bar) NSCWP union contains a stainless steel orifice plate which is drilled to the specific size hole required based on the flow calculation.* The orifice plate provides readily visible orifice identification. The orifice union is available in six sizes: 1/2 in., 3/4 in., 1 in., 1 1/4 in., 1 1/2 in., and 2 in. NPT. All pressure reducer/unions must be installed in the piping with the orifice identification tab on the pressure inlet side of the system. The 1 1/4 in., 1 1/2 in. and 2 in. orifice unions must be installed per the direction of the flow arrow stamped on the body. DIRECTION OF FLOW C B VISIBLE ORIFICE IDENTIFICATION 002197 A Shipping Assembly A B C Part No. in. (mm) in. (mm) in. (mm) 416677 1/2 in. NPT pressure reducer/union 2.06 (52) 1.18 (29) 1.95 (49) 416678 3/4 in. NPT pressure reducer/union 2.38 (61) 1.50 (38) 2.38 (61) 416679 1 in. NPT pressure reducer/union 2.63 (67) 1.78 (45) 2.77 (70) 416680 1 1/4 in. NPT pressure reducer/union 2.94 (75) 2.04 (52) 3.31 (84) 416681 1 1/2 in. NPT pressure reducer/union 3.31 (84) 2.31 (59) 3.70 (94) 416682 2 in. NPT pressure reducer/union 3.56 (90) 2.85 (72) 4.39 (112) Component Material Thread Size Approvals Pressure Reducer/ Union Body: Forged Steel 1/2, 3/4, 1, 1 1/4, 1 1/2, 2 in. NPT UL Listed (EX-4510) Orifice Plate: Stainless Steel * Orifice diameter must be specified when placing order. Note: Refer to Nozzle/Pressure Reducer Range Chart in Design Section for detailed orifice range information. One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98112-03

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-35 Pressure Reducer/Nipple The pressure reducer/nipple is required to restrict the flow of INERGEN agent thus reducing the agent pressure down stream of the nipple. The nipple contains an orifice which is drilled to the specific size hole required based on the flow calculation.* The pressure reducer/nipple part number and orifice size are stamped on the body hex. The drilled orifice is on the inlet side of the nipple. The pressure reducer nipple is available in two sizes: 2 1/2 in., and 3 in. NPT. A Shipping Assembly Part No. 417057 2 1/2 in. NPT pressure reducer/nipple 417058 3 in. NPT pressure reducer/nipple A Nipple Size Hex Size in. (mm) 2 1/2 in. 3 in. 4 3/8 (111) 3 in. 3 1/2 in. 4 1/2 (114) 002198 Component Material Thread Size Approvals Pressure Reducer/Nipple Body: Brass 2 1/2 in., 3 in. NP UL Listed (EX-4510) * Orifice diameter must be specified when placing order. Note: Refer to Nozzle/Pressure Reducer Range Chart in Design Section for detailed orifice range information. One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98113-03

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-36a Flanged Pressure Reducer The flanged pressure reducer assembly is required to restrict the flow of INERGEN agent thus reducing the agent pressure down stream of the pressure reducer. The flanged pressure reducer assembly contains a stainless steel orifice plate which is drilled to the specific size hole required based on the flow calculation.* The orifice plate provides readily visible orifice identification. The flanged pressure reducer assembly is available in three sizes; 2 1/2, 3, and 4 in. Each size is available in threaded, slip-on, and weld neck flange. All orifice plates must be installed in the piping system with the orifice identification information on the tab facing the pressure inlet side of the system. Component Material Approvals Flange Forged Steel UL Listed (EX-4510) Flange Gasket Stainless Steel Orifice Plate Stainless Steel Bolts Plated Steel, Grade 5 Shipping Assembly E Part No. A B C D (8 Places) 426823 2 1/2 in Threaded 4.23 in. 7.50 in. 9.70 in. 5.88 in. 0.88 in. (107 mm) (191 mm) (246 mm) (149 mm) (22 mm) 426824 3 in. Threaded 4.10 in. 8.25 in. 10.46 in. 6.63 in. 0.88 in. (104 mm) (209 mm) (266 mm) (168 mm) (22 mm) 426825 4 in. Threaded 4.73 in. 10.75 in. 12.59 in. 8.50 in. 1.00 in. (120 mm) (273 mm) (319 mm) (216 mm) (25 mm) 426847 2 1/2 in. Slip-on 4.24 in. 7.50 in. 9.70 in. 5.88 in. 0.88 in. (108 mm) (191 mm) (246 mm) (149 mm) (22 mm) 426848 3 in. Slip-on 4.60 in. 8.25 in. 10.46 in. 6.63 in. 0.88 in. (117 mm) (209 mm) (266 mm) (168 mm) (22 mm) 426849 4 in. Slip-on 5.24 in. 10.75 in. 12.59 in. 8.50 in. 1.00 in. (133 mm) (273 mm) (319 mm) (216 mm) (25 mm) 426853 2 1/2 in. Weld Neck 7.23 in. 7.50 in. 9.70 in. 5.88 in. 0.88 in. (184 mm) (191 mm) (246 mm) (149 mm) (22 mm) 426854 3 in. Weld Neck 7.48 in. 8.25 in. 10.46 in. 6.63 in. 0.88 in. (189 mm) (209 mm) (266 mm) (168 mm) (22 mm) 426855 4 in. Weld Neck 8.98 in. 10.75 in. 12.59 in. 8.50 in. 1.00 in. (228 mm) (273 mm) (319 mm) (216 mm) (25 mm) * Orifice diameter must be specified when placing order. Note: Refer to Nozzle/Pressure Reducer Range Chart in Design Section for detailed orifice range information.

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-36b Weld Neck D C A E 003653 B 003654 Threaded Slip-On A A 003655 003656 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-99067-03

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-37 Orifice Plate Orifice plate shipping assemblies are available as replacement plates. Replacement plates may be required in situations where the piping and pressure reducer size can stay the same but because of some hazard change, the size of the orifice in the pressure reducer must change. The orifice size must be specified when ordering the orifice plate. Part No. 418095 1/2 in. Replacement Orifice Plate 418096 3/4 in. Replacement Orifice Plate 418097 1 in. Replacement Orifice Plate 418098 1 1/4 in. Replacement Orifice Plate 418099 1 1/2 in. Replacement Orifice Plate 418100 2 in. Replacement Orifice Plate 426984 2 1/2 in. Replacement Orifice Plate 426985 3 in. Replacement Orifice Plate 426986 4 in. Replacement Orifice Plate Note: Replacement orifice plates for orifice nipples are not available as the plate is a permanent fixture of the part. Note: Refer to Nozzle/Pressure Reducer Range Chart in Design Section for detailed orifice range information. One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98068-03

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-38 360 Discharge Nozzle Discharge nozzles are designed to direct the discharge of INERGEN agent using the stored pressure from the cylinders. Ten sizes of nozzles are available. The system design specifies the orifice size to be used for proper flow rate and distribution pattern*. The nozzle selection depends on the hazard and location to be protected. Standard nozzles are constructed of brass. Note: 2, 2 1/2 and 3 in. nozzles are not recommended in areas that are subject to damage by high velocity discharges. B C Shipping Assembly Part No. 417908 1/4 in. NPT nozzle 417723 3/8 in. NPT nozzle 417362 1/2 in. NPT nozzle 417363 3/4 in. NPT nozzle 417364 1 in. NPT nozzle 417365 1 1/4 in. NPT nozzle 417366 1 1/2 in. NPT nozzle 426155 2 in. NPT nozzle 426156 2 1/2 in. NPT nozzle 426137 3 in. NPT nozzle Component Material Thread Size Approvals Nozzle Body: 1/4, 3/8, 1/2, UL Listed Brass 3/4, 1, 1 1/4, (EX-4510) 1 1/2, 2, 2 1/2, 3 NPT A 002199 * Orifice diameter must be specified when ordering nozzle. Note: Refer to Nozzle/Pressure Reducer Range Chart in Design Section for detailed orifice range information. A B C Size in. (mm) in (mm) in. (mm) Hex 1/4 in. 5/8 (16) 1 9/16 (40) 21/32 (17) 5/8 3/8 in. 3/4 (19) 1 5/8 (41) 23/32 (18) 3/4 1/2 in. 15/16 (24) 1 31/32 (50) 27/32 (21) 15/16 3/4 in. 1 1/8 (29) 2 5/32 (55) 7/8 (22) 1 1/8 1 in. 1 13/32 (36) 2 9/16 (65) 1 (25) 1 7/16 1 1/4 in. 1 3/4 (44) 2 3/4 (70) 1 1/16 (27) 1 3/4 1 1/2 in. 2 (51) 2 31/32 (75) 1 1/16 (27) 2 2 in. 2 3/8 (60) 3 (76) 1 (25) 2 3/8 2 1/2 in. 3 (76) 3 1/2 (89) 1 (25) 3 3 in. 3 1/2 (89) 4 1/8 (105) 1 1/4 (32) 3 1/2 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98114-03

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-39 180 Discharge Nozzle Discharge nozzles are designed to direct the discharge of INERGEN agent using the stored pressure from the cylinders. Ten sizes of nozzles are available. The system design specifies the orifice size to be used for proper flow rate and distribution pattern*. The nozzle selection depends on the hazard and location to be protected. The 180 nozzle is commonly used when nozzle placement is at or near the bulkhead. Standard nozzles are constructed of brass. An index mark is stamped on the bottom of the nozzle to indicate aiming direction. * Orifice diameter must be specified when ordering nozzle. Note: Refer to Nozzle/Pressure Reducer Range Chart in Design Section for detailed orifice range information. Shipping Assembly Part No. 426138 1/4 in. NPT nozzle 426139 3/8 in. NPT nozzle 426140 1/2 in. NPT nozzle 426141 3/4 in. NPT nozzle 426142 1 in. NPT nozzle 426143 1 1/4 in. NPT nozzle 426157 1 1/2 in. NPT nozzle 426144 2 in. NPT nozzle 426145 2 1/2 in. NPT nozzle 426146 3 in. NPT nozzle Component Material Thread Size Approvals Nozzle Body: 1/4, 3/8, 1/2, UL Listed Brass 3/4, 1, 1 1/4, (EX-4510) 1 1/2, 2, 2 1/2, 3 NPT B 22.5 C INDEX MARK A 002743 002742 A B C Size in. (mm) in (mm) in. (mm) Hex 1/4 in. 5/8 (16) 1 9/16 (40) 21/32 (17) 5/8 3/8 in. 3/4 (19) 1 5/8 (41) 23/32 (18) 3/4 1/2 in. 15/16 (24) 1 31/32 (50) 27/32 (21) 15/16 3/4 in. 1 1/8 (29) 2 5/32 (55) 7/8 (22) 1 1/8 1 in. 1 13/32 (36) 2 9/16 (65) 1 (25) 1 7/16 1 1/4 in. 1 3/4 (44) 2 3/4 (70) 1 1/16 (27) 1 3/4 1 1/2 in. 2 (51) 2 31/32 (75) 1 1/16 (27) 2 2 in. 2 3/8 (60) 3 (76) 1 (25) 2 3/8 2 1/2 in. 3 (76) 3 1/2 (89) 1 (25) 3 3 in. 3 1/2 (89) 4 1/8 (105) 1 1/4 (32) 3 1/2 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98115-03

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-40 Pressure-Operated Siren The pressure-operated siren is used to warn personnel of a system discharge. The siren is operated with the nitrogen pressure from the pilot cylinder. The siren will operate at the start of the INERGEN system actuation and will continue through most of the discharge time. A pipe hanger or bracket must be installed within one foot of the siren. Component Material Approvals Siren Body: Brass UL EX-4510; Listed Grille: Steel for use with FM Screen: Stainless Approved systems Steel The design requirements are as follows: Maximum Pipe Length: 240 ft (73.2 m) of 3/4 in. Schedule 40 pipe 430 ft (131.1 m) of 1/2 in. Schedule 40 pipe 675 ft (205.7 m) of 3/8 in. Schedule 40 pipe Maximum Sirens: 5 Maximum Elbows: 30 Shipping Assembly Part No. 437616 Pressure-operated siren 0.34 IN. (9 mm) DIA. HOLE (2) 6.25 IN. (159 mm) 1/4 IN. NPT INLET 5.25 IN. (133 mm) 5.60 IN. (142 mm) 3.42 IN. (87 mm) 008806 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-2012070

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 3 UL EX-4510 4-16-12 Page 1-41 Pressure Switch 3PDT The pressure switch is operated by the INERGEN agent pressure when the system is discharged. The pressure switch can be used to open or close electrical circuits to shut down equipment (single or 3-phase) or turn on lights or alarms. The housing is constructed of 16 ga. steel, painted red, and is rated IP65 for dust and water ingress. The 3/8 in. NPT brass pressure inlet is used to connect the pressure switch to the suppression system. Shipping Assembly Part No. 437900 Pressure switch 3PDT Minimum operating pressure is 50 psi (3.5 bar). Component Material Thread Size/Type Electrical Rating Approvals Pressure Switch Switch: Nickel-plated Brass Conduit Inlets: 10A, 250 VAC UL Listed 3PDT Housing/Cover: C.R. 16 ga steel 3/4 in. and 1/2 in. 15A, 125 VAC (EX-4510) Plunger: Stainless Steel Pressure Inlet: 3/4 HP, 250 VAC Pressure Port: C37700 Brass 3/8 in. NPT Female 1-, 2-, and 3-phase 6.0 IN. (152 mm) 4.45 IN. (113 mm) 4.51 IN. (115 mm) 4.45 IN. (113 mm) 2.75 IN. (70 mm) 3.83 IN. (97 mm) 008978 5.25 IN. (133 mm) 008979 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-2012058

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-42 Pressure Switch DPDT Explosion-Proof The pressure switch is operated by the INERGEN agent pressure when the system is discharged. The pressure switch can be used to open or close electrical circuits to either shut down equipment or ventilation systems and turn on lights or alarms. The double pole, double throw (DPDT) pressure switch is constructed with an explosion-proof housing suitable for hazardous environments. A 1/4 in. NPT pressure inlet is used to connect the 1/4 in. pipe from the INERGEN system. The pressure switch can be installed either before or after the pressure reducer in the distribution piping. Minimum operating pressure is 100 psi (6.9 bar). Shipping Assembly Part No. 43241 Pressure switch DPDT Component Material Thread Size/Type Electrical Rating Approvals Pressure Switch Housing: Conduit Inlet: 3/4 in. NPT Female 10A - 125 VAC UL Listed (EX-4510) DPDT Malleable Iron Pressure Inlet: 1/4 in. NPT Female 5A - 250 VAC 1/4 IN. PIPE CONNECTION TO INERGEN SYSTEM 1/4 IN. UNION 3/8 IN. X 1/4 IN. BUSHING 3/4 IN. CONDUIT OUTLET 7 7/8 IN. (200 mm) 6 1/2 IN. (165 mm) 5 3/16 IN. (147 mm) 5 1/8 IN. (130 mm) NAMEPLATE 2 5/8 IN. (66 mm) 3 9/16 IN. (91 mm) 2 11/32 IN. MOUNTING HOLES 000454 5 5/8 IN. (142 mm) 3/4 IN. CONDUIT OUTLET 000455 Note: Suitable for hazardous locations, Class I, Division I, Groups C, D, and Class II, Division I, Groups E, F, G. One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98118-02

THIS PAGE INTENTIONALLY LEFT BLANK System Components U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-43

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-44 Pressure Trip The pressure trip is connected to the actuation or discharge line of an INERGEN system. By either pneumatic or manual actuation, the pressure trip can release spring or weight powered devices to close ventilation dampers, open fuel dump valves, close fire dampers or close fuel supply valves. The pressure trip is constructed of brass with two 1/4 in. NPT fittings for connection to discharge or actuation lines. The link on the pressure switch is released either pneumatically, by agent discharge pressure; or manually, by use of the pull ring. The link then releases the device which performs the auxiliary functions. Note: Operating pressure must be a minimum of 75 psi (5.2 bar) with a maximum load of 70 lb (31.8 kg). Shipping Assembly Part No. 5156 Pressure trip Component Material Thread Size/Type Approvals Pressure Trip Brass 1/4 in. NPT Female UL Listed (EX-4510) 3 3/4 IN. (95 mm) 1/4 IN. NPT 3 IN. (76 mm) 000452 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98120-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-45a Cylinder Bracketing The cylinder bracketing is designed to rigidly support the installed INERGEN agent cylinders. The bracketing components are constructed of heavy structural steel. Bracket assemblies are available in modules for two to six cylinders and can also be connected together for any combination over six. Bracketing can be assembled to support single row, double row or back-to-back rows of cylinders. Bracketing components are painted with a red enamel coating. Uprights and back frame assemblies can be bolted or welded together, which ever makes the installation more convenient. Component Material Approvals Bracketing Steel UL Listed (EX-4510) Shipping Assembly Part No. 45120 200 ft3 (5.7 m3) cylinder strap (single cylinder) 45244 200 ft3 (5.7 m3) cylinder channel with nuts and bolts (single cylinder) 45121 250 ft3 (7.1 m3) cylinder strap (single cylinder) 45261 250 ft3 (7.1 m3) cylinder channel with nuts and bolts (single cylinder) 45122 350 ft3 (9.9 m3) cylinder strap (single cylinder) 45245 350 ft3 (9.9 m3) cylinder channel with nuts and bolts (single cylinder) 427704 435 ft3 (12.3 m3) cylinder strap with padding (single cylinder) 427705 435 ft3 (12.3 m3) cylinder channel with nuts, bolts, saddle, and padding (single cylinder) 79638 Back frame assembly (2 cylinder) 79639 Back frame assembly (3 cylinder) 79640 Back frame assembly (4 cylinder) 79641 Back frame assembly (5 cylinder) 79642 Back frame assembly (6 cylinder) 73257 Upright for 200, 250, 350, and 435 ft3 cylinders (used either for right side, left side or center (center upright required when connecting seven or more cylinders in a row)) 73553 Single row or back-to-back row bracket foot (left side) 73554 Single row or back-to-back row bracket foot (right side) 73555 Double row bracket foot (left side) 73556 Double row bracket foot (right side) 418508 Center upright foot 79413 Connector (required to hook together back frames for seven or more cylinders) 73250 10.5 in. (267 mm) carriage bolt with lockwasher and nut (for single row 200 ft3 (5.7 m3) cylinders) 73251 11 in (279 mm) carriage bolt with lockwasher and nut (for single row 250 ft3 (7.1 m3) cylinders) 73252 12.5 in. (318 mm) carriage bolt with lockwasher and nut (for single row 350 ft3 (9.9 m3) and 425 ft3 (12.0 m3) cylinders) 418502 13 in. (330 mm) carriage bolt with lockwasher and nut (for single row 435 ft3 (12.3 m3) cylinders) 73253 21 in. (533 mm) carriage bolt with lockwasher and nut (for double row 200 ft3 (5.7 m3) cylinders) 73254 22 in. (559 mm) carriage bolt with lockwasher and nut (for double row 250 ft3 (7.1 m3) cylinders) 73255 26 in. (660 mm) carriage bolt with lockwasher and nut (for double row 350 ft3 (9.9 m3) and 425 ft3 (12.0 m3) cylinders) 418503 27 in. (686 mm) carriage bolt with lockwasher and nut (for double row 435 ft3 (12.3 m3) cylinders)

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-45b Shipping Assembly Part No. 73091 Cylinder clamp (2 cylinders) 73092 Cylinder clamp (3 cylinders) 71683 Weigh rail support single row 71682 Weigh rail support double row 71684 Weigh rail support back-to-back rows 423027 Weigh rail support back-to-back double row Multi-Cylinder Single Cylinder UPRIGHT BACK FRAME* CYLINDER CLAMP* CARRIAGE BOLT WITH NUT AND LOCKWASHER RIGHT BRACKET FOOT CHANNEL CLAMP LEFT BRACKET FOOT 004386 * Note: Two sets of cylinder clamps and back frame assemblies are required to secure cylinders. One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98116-02

U.S.C.G. APPROVAL NO. 162.162/1/0 REV. 2 UL EX-4510 4-16-12 Page 1-46 Pressure Test Assembly The Pressure Test Assembly (Part No. 423923) is required to properly perform the semi-annual pressure check per NFPA 2001. The pressure test assembly consists of a calibrated gauge, adaptor, and handwheel. The assembly is attached to the fill port of the INERGEN valve. As the handwheel is turned in, the fill port is opened and the pressure is read on the gauge. After verifying the pressure in the cylinder, the handwheel is turned out, closing the fill port and venting the pressure. With the pressure vented, the assembly can be removed. Shipping Assembly Part No. 423923 Pressure Test Assembly Component Material Approvals Handwheel Cast Zinc Alloy UL Listed (EX-4510) Body Brass Adaptor Brass Gauge Stainless Steel Case Laminated Safety Glass Lens 002744 One Stanton Street +1-715-735-7411 Marinette, WI 54143-2542 www.ansul.com Copyright 2012 Tyco Fire Products LP. All rights reserved. Form No. F-98121-02