Automatic concealed bollards 275 H600 and 275 H800 with pit

Similar documents
Automatic concealed bollards 275 H600 and 275 H800 Control station

EC DECLARATION OF CONFORMITY

Installation Manual. Swing Gate System. Leading the way...

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

Automatic hidden traffic bollards 275 H600 and 275 H800 with pit

INDEX CE DECLARATION OF CONFORMITY FOR MACHINES... 2 WARNINGS FOR THE INSTALLER DESCRIPTION AND TECHNICAL SPECIFICATIONS...

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

FORCE SPD 800/1500/2000

CE DECLARATION OF MACHINE CONFORMITY

Automation Swing Gate Opener

IMPORTANT NOTICE FOR THE INSTALLER

Index. 4 DESCRIPTION... p. 5 5 PRELIMINARY CHECKS... p. 5 6 ASSEMBLY... p. 6

Index. 4. DESCRIPTION... p PRELIMINARY CHECKS... p ASSEMBLY... p. 6

Typical Installation Schematic

J SERIES BOLLARDS Solutions for vehicle access control and city traffic

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

INSTRUCTIONS FOR INSTALLATION

Index. 4. DESCRIPTION... p PRELIMINARY CHECKS... p ASSEMBLY... p. 6

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

TECHNICAL DATA HYDRAULIC UNIT

RETRACTABLE BOLLARD PILOMAT PASS PM 127/P-800 A TECHNICAL INSTRUCTIONS. Manuale tecnico PILOMAT 127P-800 A PZ.doc Pagina 1 di 22

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

INSPECTIONS AND MAINTENANCE

BULL 424 ESA BULL 624 ESA

J275/600 HA J275/800 HA

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

BISON 20 OM BISON 25 OTI

CE DECLARATION OF CONFORMITY FOR MACHINES

CE DECLARATION OF CONFORMITY OF MACHINES. Warnings for the installer General safety obligations

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

SLIDE NEW CONTROL BOARD

INSTALLATION MANUAL (cod )

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

Instruction Manual for the. E-SL 1800 Series. Warning! Read all instructions before beginning installation or use of this door opener.

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

I - Libretto di istruzioni GB - Instructions manual F - Notices de montage

ISTRUCTION MANUAL Italian Movements Italian Movements

Ditec LUXO Swing gates automation (Original instruction)

WARNINGS FOR THE INSTALLER

A B O U T FA A C C A N A D A

BARRY BARRIER GATE AUTOMATION

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

E R A I GATE AUTOMATION DIVISION

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

Ditec CUBIC Swing gates automation

Featuring. Manufactured by

Ditec DOD Industrial sectional door automations

Instruction Manual for the

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

IGEA LB INSTALLATION AND USER'S MANUAL. MONTAGE- und BEDIENUNGSANLEITUNG INSTRUÇÕES DE USO E DE INSTALAÇÃO

CE DECLARATION OF CONFORMITY INSTALLATION WARNINGS

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Instructions manual. Below ground oil-hydraulic operator for swinging gates. pages 17-32

Ditec BOX Balanced up and over doors

AUTOMATIC BOLLARD ASSEMBLY AND OPERATING MANUAL

Swing Piston Compressors and Vacuum Pumps

FITTING AND CONNECTION INSTRUCTIONS

Mod: KLD6-12/35XLAS-N

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

ARACHNE 230V 24V- 12V

HIGH SPEED SLIDING GATE OPENER

VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT

Pan and Tilt Head CDD2416-T

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

SPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

The House of Gate Automation

INSTALLER AND USER S MANUAL. v4.0 REV. 01/2019

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

CE DECLARATION OF CONFORMITY IMPORTANT NOTICE FOR THE INSTALLER

GB Instructions Manual

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

ECONOMISER SERIES E2T USER MANUAL

Instruction Manual for the

FEATURES AND SPECIFICATIONS

TITANO 400V SLIDING GATE OPENER

Installation Manual for Heavy Duty Carriage Door Opener

Instruction Manual for the. Heavy Duty Series Carriage Door Instructions. Warning!

BAYT 980. Oil-hydraulic Road Traffic Barrier. BAYT 980 painted version BAYT 980 stainless steel version inox

Oil-hydraulic operator for swinging gates

Midi Traffic Light installation manual TRAFFIC CONTROL ACCESSORIES

EC DECLARATION OF CONFORMITY

DOCUMENT TYPE = FITTING INSTRUCTIONS ORIGINAL LANGUAGE = ENGLISH. Maximum door weight = 40kg per leaf total system 80kg

Oil-free piston compressors KK and piston vacuum pumps KV

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Installation and Maintenancee Manual

Transcription:

Automatic concealed bollards 275 H600 and 275 H800 with pit

Technical installation manual CE Declaration of conformity Warnings for the installer Bollard technical data Preparing and installing the bollard Electric connection of bollard to 462DF equipment and relevant settings Installation of safety inductive loops Manual lowering operation Maintenance procedures

CE DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/CE) Manufacturer: FAAC S.p.A. Address: Declares that: Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALIA The FAAC CITY model operator is built to be incorporated into a machine or to be assembled with other machinery to create a machine under the provisions of Directive 98/37/CE; conforms to the essential safety requirements of the other following EEC directives: 73/23/EEC and subsequent amendment 93/68/EEC. 89/336/EEC and subsequent amendment 92/31/CEE and 93/68/EEC Furthermore, the manufacturer declares that the machinery must not be put into service until the machine into which it will be incorporated or of which it will become a part has been identified and its conformity to the conditions of Directive 98/37/CE has been declared. Bologna, 01 January 2005 The Managing Director A. Bassi

WARNINGS FOR THE INSTALLER - GENERAL SAFETY OBLIGATIONS 1 IMPORTANT! To ensure the safety of people, it is important that all the instructions be carefully observed. Incorrect installation or incorrect use of the product could cause serious harm to people. 2 Carefully read the instructions before beginning to install the product. 3 Packing materials (plastic, polystyrene, etc.) must not be left within the reach of children, because these materials are potential danger sources. 14 Make sure that the earthing system is workmanlike built and connect the metal parts to it. 15 The automated system consists of an intrinsic anti-crushing safety device controlling the torque. However, you must check its action threshold as mentioned in the Regulations in point 10. 16 Safety devices (EN 12978 standard) protect possible danger areas against Mechanical movement risks. e.g. crushing, carrying away and shearing. 4 Keep the instructions for future reference. 17 Use of at least one warning light is recommended for every system (e.g. a built-in flashing light on the bollard head), a warning sign, in addition to the devices mentioned in point "16". 5 This product was designed and built exclusively for the use indicated in this documentation. Any other use not expressly indicated could compromise the integrity of the product and/or be a source of danger. 6 FAAC S.p.A. declines any responsibility due to improper use or use other than the use for which the automated system is intended. 7 Do not install the equipment in an explosive atmosphere. the presence of gas or inflammable fumes is a serious danger to safety. 8 For non-eu countries, to achieve an adequate safety level, the above mentioned standards must be observed in addition to the national standard references. 9 FAAC S.p.A. is not responsible for the non-observance of good workmanship in installing FAAC CITY products and the relevant accessories, or for any deformation which may occur through use. 10 The installation must be carried out by observing the current regulations in force. 11 Before attempting any action on the system, cut out the electrical power supply. 12 Install an all-pole switch on the electricity supply line for the automated system, with contact opening distance of 3 mm or more. We advise you to use a 6A differential thermal breaker with all-pole switching. 13 Make sure that a differential switch with a threshold of 0.03A is installed upstream of the system. 18 For maintenance, strictly use original FAAC S.p.A. parts. 19 FAAC S.p.A. declines all responsibility on the safety and efficient operation of the automated system, if system components not produced by FAAC S.p.A. are used. 20 Do not in any way modify the components of the FAAC CITY automated system. 21 The installer must supply to the user Customer, all the information about the manual lowering of the bollard in case of an emergency, and must hand over to the System User the warning handbook which accompanies the product. 22 Do not allow children or persons to stay near the bollard, especially while it is in operation. 23 Keep radio controls or other pulse generators away from children, to prevent the automated system from being activated involuntarily. 24 The FAAC CITY bollard must be transited over only when the device is completely lowered. 25 The User must not in any way attempt to repair or to take direct action and must contact qualified authorised personnel only. 26 Anything not expressly specified in these instructions is not permitted.

TECHNICAL SPECIFICATIONS FOR FAAC CITY 275 H600 AND 275 H800 Motion criterion Hydraulic Driven cylinder Fe37 *1 steel - thickness 6 mm Treatment of drive cylinder Polyester powder paint, dark grey metallised colour *2 Driven cylinder diameter 275 mm. Driven cylinder stroke 600mm (275 H600) and 800 mm. (275 H800) Cylinder top part (head) Anticorodal case hardened aluminium Cylinder surface treatment Polyester powder paint, light grey metallised colour Descent time 9 sec. (275 H600) - 12 sec. (275 H800) Rise time 9 sec. (275 H600) - 12 sec. (275 H800) Hydraulic pump Power supply 230V +6/-10% 50Hz Protection class IP 67 Capacitor for pump 16 µf Absorption Work frequency Refracting adhesive band 220W Intensive use Standard height 80 mm Operating temperature - 40 C + 70 C * 3 Total weight with pit Kg. 180 Manual lowering operation YES * 4 Impact resistance 6,000 joule (FE37 steel thickness 6 mm.) Dimensions of pit to be walled in 560 x 560 x 1020 (275 H600) 560 x 560 x 1220 (275 H800) Standard length of connected cable 10 mt. * 5 * 1 optional article: FE37 10 mm thick steel or 6 mm thick AISI 304 stainless steel * 2 optional article: customised sprayed paint in RAL colour scale * 3 optional article: heating elements (recommended for temperatures below -15 C to limit ice forming on the cylinder) * 4 optional article: automatic lowering device in case of a black-out * 5 optional article: lengths up to 30 mt to order.

AUTOMATIC BOLLARDS WITH PIT FAAC CITY 275 H600 and 275 H800 INSTALLATION LAY-OUT 1) Make sure that the installation point of the FAAC CITY bollard is not in a valley zone. In a situation of this kind, the FAAC CITY bollard must be partially protected, by surrounding it with a drainage channel, equipped with a covering grating. 2) Excavate down to a depth of about 1.30 m (275 H600) or about 1.50 m (275 H800); the crosssection must have a side of about 1 m (fig. 1 and fig. 2). 3) Make sure that the soil has good drainage capacity: pour about 40 litres of water in the excavation and check if it empties within 30 minutes. If it does not, construct the rain water discharge by using a 60 mm diameter pipe connected to the sewage system or, alternatively, connected to a pit, equipped with an emptying system (an electric pump for example) of greater depth than the FAAC CITY pit, which collects and discharges rain water. 4) Distribute gravel (with grain diameter of about 8-20 mm) to a thickness of about 30 cm, taking care to compact it well, to avoid future "settling shrinkage". 5) Lay the metal pit complete with sub-frame, taking care to place it perfectly vertical. The top level of the sub-frame must be positioned about 10 mm higher than the tread surface (to limit entry of rainwater into the pit). Position the pit, checking the position of the reference on the sub-frame in relation to the transit direction (fig.1 and fig. 2). 6) When the pit has been installed, lay a flexible sheath (with 45 mm inside diameter) from the electrical connection in the pit to the motion control station. 7) Distribute concrete all around the pit, up to about 10cm from the tread surface dimension, making sure that the rag-bolts supplied with the pit are appropriately positioned. When the pit has been installed, finish the road surface with the same type of material (fig. 3 and fig. 4). 8) Lay the pipes required for connecting the management station to any additional equipment (e.g. 'traffic lights' - inductive loops - card reader etc.) and to any other bollards present, and prepare the electrical and earthing connections (fig. 5). N.B.: all pipes must be laid observing regulations in force.

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

CONNECTION LAY-OUT FOR PIT - EQUIPMENT 462DF PE 1 C4 2 3 5 PE 1-6 RL1 25 3 R4 R1 C1 23 4 R2 RL2 C2 22 2 nc nc nc NOT CONNECTED nc nc nc nc 24 RL1 27 nc = not connected RL2 C3 R3 7 8 Fig. 6

CONNECTION TO EQUIPMENT 462DF To control FAAC City with 462DF, the external components indicated below (not supplied) must be connected, observing the lay-out of fig. 6: R1 = R2 = R3 = 100ohm 1/4W R4 = 68ohm 1W C1 = C2 = C3 = 0,1µF 400Vac C4 = Capacitor 16 µf 450Vac (supplied standard) RL1 = Relay (24 Vdc coil) N.C. contact RL2 = Relay (230Vac coil) N.O. contact The following registers must be modified on the 462DF equipment: REG. 14 = hex: 0001XXXX - special indicator light function - (XXXX = the value of these bits depends on other functions) REG. 46 = 2 - Pre-flashing before raising (optional) To connect the accessories and for programming, consult the instructions for 462DF and the Faactotum programmer. HOW TO POSITION THE SAFETY INDUCTIVE LOOPS Any inductive loops on the system must be laid according to specific instructions for the detector. Two laying examples are shown in the following figures. Fig. 7 shows the laying of a loop providing perimetric protection of the bollard. Fig. 8 shows the laying of two loops for protecting a very large gate. 80cm min 80cm min 50-100cm Fig. 7

140cm max 80cm min 100cm min Fig. 8 MANUAL LOWERING OPERATION In case of an emergency or fault, manually controlled bollard lowering is possible with the following procedure: Unfasten the Allen screw located on the base, until you remove it from its seat. Press the key under the screw's seat, using the Allen wrench. The bollard descends for as long as you hold the key down. When the bollard has been lowered, re-fasten the screw on the base. The manual lowering device is not supplied on FAAC CITY models with the automatic lowering device. FINAL OPERATIONS When you have finished the installation, check the efficiency of the bollard, especially as regards any safety devices which may be installed.

STANDARD 6-MONTHLY ROUTINE MAINTENANCE PROCEDURE FOR MOBILE CONCEALED BOLLARD FAAC CITY 275 H600 AND 275 H800: This is the standard routine maintenance sequence: Clean the pit, exhausting the deposited materials by suction Clean the water drainage discharge points on the bottom of the pit Clean and lubricate the central sliding guide Check (and replace if necessary) the lower contact point seals Check and, if necessary, remedy any oil leaks from the motion piston. Run a general tightness check of the bollard's screws Generally clean the driven cylinder and touch up the paint if necessary Check the hydraulic power-pack, top up with oil if necessary, and check the operating pressure setting. Check and, if necessary, set the efficiency of the safety pressure switch (40 Kg.) ALSO RUN THE FOLLOWING CHECKS: Check the efficiency of the flashing light incorporated into the bollard head Check the efficiency of the inductive safety loops Check the efficiency of the radio control receiver Visually check the electronic control unit

FAAC S.p.A. Via Benini, 1 40069 Zola Predosa (BO) - ITALIA Tel.: 051/61724 - Fax: 051/758518 www.faac.it Distributor s Stamp: The descriptions and illustrations contained in the present manual are not binding. FAAC reserves the right, whilst leaving the main features of the equipments unaltered, to undertake any modifications it holds necessary for either technical or commercial reasons, at any time and without revising the present publication. 732868 rev. A