Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Similar documents
Heat Meter Integrator

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

zelsius Installation and operating manual All that counts EnergyMetering

zelsius Installation and operating manual All that counts. EnergyMetering

Datasheet PDCSY-AV-W PDCSY-AV-W. Technical Overview. Features. Product warranty and total quality commitment.

SonoMeter 30 Energy Meters

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

RAY COMPACT ENERGY METER MECHANICAL

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Fluidic Oscillation Compact Heat Meter

SonoMeter 30 Energy Meters

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

HYDRUS ULTRASONIC METER

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

Superstatic 440. Static Heat- and Cooling Meter. Application

Compact Static Heat Meter of High-Tech Composite

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

HYDRUS ULTRASONIC METER

WESAN WPV E ELECTRONIC METER WOLTMAN

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

Superstatic 749. Fluidic Oscillation Compact Heat Meter

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Supercal 539. Compact thermal energy meter

Supercal 539 Universal compact heat meter

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

WZMC-402 Ultrasonic Apartment Energy Meters

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

ULTRASONIC FLOW SENSOR IFX-M4-01

Measuring capsule heat meter G54 / G55

CORONA E ELECTRONIC METER MULTI-JET

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

Residential. Ultrasonic Cooling Meter ULTRACOLD T350 (2WR6...) A customer tailored cooling meter designed for residential needs and easy billing

ULTRASONIC METER FOR HEATING AND COOLING SKU-03

CORONA ER ELECTRONIC METER MULTI-JET

F 90 Heat Meter Warmly recommended to cool-headed economisers

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

SHARKY FS 473 ULTRASONIC FLOW SENSOR

Paddle-wheel flow controller for On/Off control

Metering systems 0483EN October 2013 Metering units for sanitary or service water

Heating Cost Allocation Valve with local acquisition of the flow temperature

EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

TOPAS PMW-basic. Customer benefits. Product features

tprime TM Series 280T

REQUIRED TOOLS 3 mm screw driver Wrench Crosstip screwdriver

Paddle-wheel flow controller for On/Off control

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

ULTRASONIC HEAT METER

Heat meter (E1) θ: 2 C C. DK-0200-MI qp, p/l: See display. S/N: /K8/17 Type: 603C219. Pt500-EN Battery, 1 x D-cell

CONTOIL VZFA/VZOA , versions for higher requirements / applications

Ultrasonic heat meter

SonoSensor 30 Ultrasonic flow sensor

MULTICAL 6M2. Data sheet

Paddle-wheel flow controller with optical principle for On/Off control

DKG-114 MANUAL AND REMOTE START UNIT

M-bus impeller type heat and heat/refrigeration meters

Horizontal Distribution Units - HDU Multi-port

Electronic Heat Meters

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Operating Instructions

Parker Hannifin GmbH & Co. KG Tube Fittings Division Europe Am Metallwerk 9, Bielefeld Phone Fax

SITRANS FUE950 *085R9430* Energy calculator type SITRANS FUE950. Operating Manual Edition 09/ Revision 03

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

User Manual Rittal PMC UPS 6kVA

aquaconcept Product features Customer benefits

Temperature sensors. and accessories for heat and cooling measurement points. Applications. Benefits. Features

Positive displacement batch controller

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Design and application

OPTISWITCH 6500 C Technical Datasheet

DC Energy Measurement for EV Charging Stations

Operating Instructions. Angle Seat Control Valve. Type 7020

WATERFLUX 3070 Quick Start

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating Instruction for Electronic Pressure Switch. Model: PDD

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

zelsius C5-ISF Installation and operating manual All that counts. EnergyMetering

Electronic Water Meters

Installation & User Guide. Multical 801. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

Electronic Limit Switch Type

User Manual Solar Charge Controller 3KW

TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual

Solenoid valves MHJ, fast-switching valves

Infocal 9 Energy calculator for heating and cooling applications

ECONOMISER SERIES E2T USER MANUAL

Service instructions. MAGNA Series 2000

Magnetic-Inductive Flow Meter FMI

Operating instructions Binary level sensor. LI214x /00 04/2016

INTECH Micro 2300-RTD6

Evaluation Certificate

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Important instructions

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

Transcription:

Datasheet Ultrasonic Flow Sensors & Integrator Technical Overview Ultrasonic flow sensors have no moving parts in the volume flow, this makes them almost wear free and noiseless. They measure the flow by using the transit time principle, one ultrasonic signal is launched in the flow direction and one against the flow direction. The flow rate is concluded by the delay time measured, this information is then transmitted to the calculator by the way of electronic pulses. The calculator uses the latest innovative technology to calculate heat usage from heating systems. With its dynamic measuring cycle even the smallest energy consumptions are reliably collected. The large multifunction display permanently shows the heat consumption total, and by using the button is it possible to scroll through the display to show all data. Features Simply operation Long life ultrasonic flow meter Integral wall and DIN-rail mounting bracket Pulsed or M-Bus output options Product warranty and total quality commitment Our products carry a two-year warranty. Distech Controls is an ISO 9001 registered company. 1/11

General Information Initial verification The PDCSY-MW-MD is produced and tested in compliance with the new European measuring instruments directive (MID). According to this directive, devices do no longer carry an initial verification stamp, but rather the year of the device s declaration of conformity (recognizable on the front of the device, for example: M09). The MID controls the use of heat meters up to the moment they are placed on the market resp. their first putting into use. After this, the national regulations for devices subject to legal verification apply within the EU. The duration of initial verification validity in Germany remains 5 years for heat meters. After this period has expired, the measuring device may no longer be used for billing in commercial use. The regulations resp. validity period may vary in other countries of the EU. Electro-magnetic interference The PDCSY-MW-MD fulfils the national and international requirements for interference resistance. To avoid malfunctions due to other interferences, do not install fluorescent lamps, switch cabinets or electric devices such as motors or pumps in the immediate vicinity of the meter (minimum distance 1 m). Cables leaving the meter should not be laid parallel to live cables (230V, minimum distance 0.2 m). Care instructions Clean plastic surfaces with a damp cloth only. Do not use any scouring or aggressive cleaning agents! The device is maintenance-free during the service life. Repairs can only be made by the manufacturer. Declaration of Conformity Sontay Ltd declares that this product with the number of the EC type examination certificate DE-08-MI004-PTB012 complies with the requirements of the EC directives 2004/22/EC (Measuring instruments directive) and 89/336/ EEC (electro-magnetic compatibility). 2/11

Product Product Codes: Heat Meter Integrator (build unit with following options) Output type (add to above code) -P Pulsed output -M M-Bus output Flow Sensor (add to above code) -4 Qp 0.6m³/h, G¾ (R½ ) screwed -5 Qp 1.5m³/h, G¾ (R½ ) screwed -6 Qp 2.5m³/h, G1 (R¾ ) screwed -7 Qp 3.5m³/h, G1 ¼ (R1 ) screwed -8 Qp 6m³/h, G1 ¼ (R1 ) screwed -9 Qp 10m³/h, G2 (R1 ½ ) screwed -E Qp 10m³/h, DN40 flanged -F Qp 15m³/h, DN50 flanged -G Qp 25m³/h, DN65 flanged -H Qp 40m³/h, DN80 flanged -J Qp 60m³/h, DN100 flanged Installation Safety instructions The installation has to be done by qualified personnel. Read the instructions carefully right up to the end before starting to mount the device. The current laws and regulations have to be observed, especially EN 1434 part 1+6. At devices with communication interfaces or mains supply the general technical rules and the correspondent regulations have to be followed. 3/11

Installation (continued) While demounting flow sensors and temperature sensors care should be taken to ensure that no heating water escapes from the pipe this can cause burns! Close valves and release pressure before installation. Take care of: The display must readable at all times, to avoid malfunctions due to other interferences do not install fluorescent lamps, switch cabinets or electric devices such as motors or pumps in the immediate vicinity of the meter (minimum distance 1 m). All welding must be finished. The ambient temperature must not exceed 55 C. The type of temperature sensor must correspond with the calculator. The pulse value of the flow sensor must correspond with the one from the calculator. The calculator has 7 screwed cable glands for wires with a diameter between 4.2 and 10 mm. Keep unused glands closed. Mind the connection order: temperature sensors first, flow sensor afterwards! The MW-MD is delivered ready for operation. It does not need any settings or adjustment. Installation heat calculator Sontay recommends to mount the calculator on the wall. Do not mount the device at the pipe or attach it directly on the flow sensor. The mounting adapter at the backside of the calculator can be used for DIN-rail mounting or reverse for wall mounting. For wall mounting attach the adapter with at least two screws to the wall and clip the calculator on it. For rail mounting lift the adapter a little bit, place the calculator on the rail and push the adapter back until it locks. DIN-rail mounting Wall mounting Connection sensors The mounting of the temperature sensors should be done symmetrical with direct immersion. If immersion sleeves are used they have to be checked for conformity to MID and have to be marked accordingly. The installation of immersion sleeves has to be done according to DIN EN 1434-2. The sensor cables are marked with colours (red = supply, blue = return). Do not buckle, extend or shorten the wires! Do only use paired sensors with the same serial number on it. Supply and return sensors must be inserted into the immersion sleeves completely. Installation points in the flow sensor can be used for symmetrical installation of the temperature sensors. Seal temperature sensor after installation to prevent unauthorized demounting (seals included). Do not wrap or install wires along hot pipes. 4/11

Installation (continued) Connection flow sensor The total length of the wire between flow sensor and calculator should not exceed 10 m. Mind the polarity at electronic flow sensors. Operation test Check the calculator for any error codes in the display after installation (see Page 2 for error codes). Most of the errors can be deleted by pressing the button. If the error appears permanently, it will be detected at the next measuring cycle and displayed again. Check whether the volume information is updated and the displayed temperatures correspond to the present ones while the system is running (measuring cycle 2 minutes max.). When attaching the top cover on the housing pulses on the inputs can possibly be generated. Check readings of the inputs and correct if necessary. Sealing Seal the device with the included seals to prevent unauthorized opening. Maintenance Repairs or overhaul are only allowed by the manufacturer or companies authorized by the manufacturer. Status/Error Codes The symbols in the table below show the meter s operational status. The status messages only appear in the main display (energy)! The temporary display of the warning triangle can be caused by special operating states and does not always mean that the device is malfunctioning. However, should the symbol be displayed over a longer period of time you should contact Sontay. Symbol Status Event Flow existent - Attention Check for errors Data transmission - Emergency operation Exchange device External power supply - 5/11

Status/Error Codes (continued) Error codes show faults detected by PDCSY-MW-MD. If more than one error appears, the sum of the error codes is displayed: Error 1005 = error 1000 and error 5. Code Error Event 1 Short-circuit return sensor Check sensors 2 Interruption return sensor 3 Short circuit supply sensor 4 Interruption supply sensor 5 Hardware error Exchange device 6 Battery empty/wrong temp sensor Check 7 Temp. out of measuring range Correction of heating system 100 Emergency operation Exchange device 1000 Battery life time exceeded 2000 Initial verification expired >8000 Internal hardware error Flow Sensor Data 22.6 GxB L 59.5 L 150 L 150 H DN GxB 6/11

Flow Sensor Data (continued) Nominal Flow qp m³/h 0,6 1 1,5 2,5 3,5 6 10 15 25 40 60 Nominal Diameter DN mm 15 15 15 20 25 25 40 50 65 80 100 lnch ½ ½ ½ ¾ 1 1 1 ½ - - - - Inst. Length without conn. L mm 110 110 110 130 260 260 300 270 300 300 360 Thread meter G x B D1 lnch ¾ ¾ ¾ 1 1 ¼ 1 ¼ 2 Flange Flange Flange Flange Maximum Flow qi m³/h 1,2 2 3 5 7 12 20 30 50 80 120 Minimum Flow qs l/h 12 20 30 50 35 60 100 150 250 400 600 Operating Pressure, max. PN bar 16 16 16 16 16 16 16 25 25 25 16/25 Pressure loss at Qn bar 0,14 0,06 0,13 0,2 0,06 0,15 0,12 0,1 0,1 0,16 0,14 Weight kg 1 1 1 1,5 3 3 4 8 11 13 22 Connections Temperature sensors Supply (hottest pipe) 1 2 Return (coolest pipe) 3-4 Flow sensor pulse 10 GND 11 If water meters with a potential free reed contact are connected to the inputs the connection can be made in any direction. Energy output pulse 52 GND 53 Volume output pulse 54 GND 55 Care must be taken when connection is made to a BMS. 7/11

Connections (continued) M-Bus L1 24 L2 25 M-Bus connections are given twice for incoming and outgoing of the M-Bus wires. Outputs Pulsed: The pulse value of the outputs is permanently set and corresponds with the last position of the associated display value. Example: Output 1 = energy output Energy display = XXXXX.XX MWh Last position = 0.01 MWh = 10 kwh Output pulse = 10 KWh 3...30V 0V t p t p Closing times 400m/s < t p < 600m/s M-Bus: The M-Bus interface complies with the norm EN 1434-3 and operates with 2400 baud fixed. It can be set to 300/9600 baud if necessary. Dimensions (Calculator) 126mm 54mm 106mm 8/11

Display Loops Level 1 Level 2 Energy (main display) Volume Energy at SRD Date SRD Hold down the button (H) until the device switches to another level or switches back from the sub-menu. Volume external counter 1 Pulse value counter 1 SRD value external counter 1 Volume external counter 2 Pulse value counter 2 SRD value external counter 2 Segment test Monthly values input 1 Date month 1 energy consumption Supply temperature Monthly values input 2 Date month val. Input 1 Return temperature Serial number Date month val. Input 1 Temperature difference Customer number Flow Input 1 device number Maximum flow Input 2 device number Instantaneous power Maximum power 9/11

Display Loops (continued) Level 1 Legend Sensor type & installation point Pulse value Press the button briefly (S) to switch through the display from top to bottom. When you have reached the last menu item the device automatically jumps back to the menu item at the top (loop). 1st monthly value heat energy Basic configuration Model number Date battery end Press the button for about 2 seconds (L), wait for the door symbol to appear (upper right corner of the display) and then release the button. The menu is then updated resp. switches to the sub-menu. 1st monthly value input 1 1st monthly value input 2 Time Datum Hold down the button (H) until the device switches to another level or switches back from the sub-menu. M-Bus address Baud rate Input display Error status Software version 10/11

Specification Meter: Nominal flow rate qp 0.6 to qp 60m³/h Max. static pressure: Screwed 16bar Flanged 25bar Body materials Brass Cable length 1.5m (meter to electronics) Temperature range: 1 to 130 C Temperature diff: 3 to 120K Calculator: Supply Battery life Display Cable length Sensors: & pockets Sensor length: Meter size 15-32mm Meter size 40-100mm Sensor pockets: Meter size 15-32mm Meter size 40-100mm Sensor type Pocket thread Output: Output pulse Pulse duration M-Bus Baud rate 2400 3.6V Lithium battery 6 years Multifunction 8-digit + characters LCD 2m (electronics to calculator) 1.5 meters 3 meters 45mm 105mm PT500 Matched pair ½ BSP 30Vdc max. @ 20mA 400m/s <T P <600m/s General: Ambient range: Temperature 5 to 55 C RH 95% non-condensing Conformity EN1434, MID Protection IP54 Specifications subject to change without notice. Distech Controls and the Distech Controls logo are trademarks of Distech Controls Inc. ; LONWORKS is a registered trademark of Echelon Corporation ; Niagara AX Framework is a registered trademark of Tridium, Inc. ; ARM Cortex is a registered trademark of ARM Limited ; BACnet is a registered trademark of ASHRAE ; BTL is a registered trademark of the BACnet Manufacturers Association; Windows, Visual Basic.Net are registered trademarks of Microsoft Corporation. EnOcean is a registered trademark of EnOcean GmbH. All other trademarks are property of their respective owner. 11/11