1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Similar documents
1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Enclosures. Section E

Junction Boxes Hazardous and Non-Hazardous

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

W-Series Junction Boxes

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

EDS / EFS Series Control Stations

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

WP Plugs and DS Receptacles For FS and FD Cast Device Boxes

EBMC Combination Line Starters and Enclosures

Condulet Conduit Bodies and Outlet Boxes Hazardous

Hazardous Factory Sealed Control Devices

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Covers for Cast Iron or Aluminum Device Boxes

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Motor Starters Hazardous and Non-Hazardous

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

Plugs and Receptacles: Hazardous Location

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Circuit Breakers Hazardous

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

GHG43 Series Control Stations

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Myers Hubs. Standard Finishes: Aluminum: Natural Zinc: Natural Stainless: Natural

Condulet Cast Device Boxes and Covers Application and Selection

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

ACE20 explosionproof variable frequency drives Utilizes Allen-Bradley PowerFlex 700 drives

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Spring-loaded cover seats against neoprene gasket.

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

Control Stations Hazardous and Non-Hazardous

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

PEERLESS BLOWERS DIRECT DRIVE BLOWERS

N2MV Series W Non-metallic

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

Lighting and Power Distribution Panelboards

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Form 7 Iron Conduit Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

IEC 309 Plugs, Connectors, Receptacles, and Inlets

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Division 1 Explosionproof Panelboards

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Applications. Illustrated Features

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Industrial Control & Circuit Breakers

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

Thin Wall Conduit Fittings (For EMT Conduit)

Hazardous Duty Applications

Solar Combiner Solutions

Product Specification Guide Expansion and Deflection Couplings. SECTION Raceway and Boxes for Electrical Systems

Glass Reinforced Polyester Enclosures

Stainless Steel Fittings

DMV Series W For Combustible Dusts

P-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

SynergEX Panelboards for Hazardous Locations

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

AKRON ELECTRIC, INC. CONDUIT PRODUCTS GR SERIES... EYS SERIES... TU SERIES... XBD-50 SERIES...

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Transcription:

EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications: EJB junction boxes are used in threaded rigid conduit systems in hazardous areas: As a junction or pull box To provide enclosures for splices and branch circuit taps For housing terminal blocks, relays and other electrical devices Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common, such as: offshore drilling facilities, cooling towers, coal preparation and handling facilities and sewage and waste water treatment plant In areas which are hazardous due to the presence of hydrogen or gases and vapors of equivalent hazard such as found in process industries, missile bases and gas manufacturing plants Features: boxes provided with aluminum plate cover as standard, allowing for field addition of cover device holes Stainless steel cover bolts ( only) Ground joint cover opening provides maximum opening for pulling wires or mounting equipment Walls of bodies may be drilled and tapped for conduit entries as shown in listings Stud bolts in diagonally opposite corners of body aid in aligning cover to body during installation (not furnished with hinged covers) All bodies are provided with captive, triple lead, quick release hex head stainless steel bolts with spring loaded action which provides clear indication that cover bolts are fully retracted from the body External flange design wide unobstructed cover opening provides a completely accessible interior for wiring and electrical equipment Square corners of enclosure body provide maximum interior space and area for conduit openings Internal grounding lug provides a means to ground enclosed equipment Special neoprene cover gasket provides a watertight seal to meet NEMA 4 requirements, and provides superior protection for enclosed equipment against water/corrosion ATEX certified when ordered with ATEX suffix Enclosures are machined for field installed mounting plates Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are broken. Optional stainless steel hinges provide convenient and easy access for inspection, maintenance and systems changes Enclosures are machined to accept field installed hinges EJB2208 with optional hinged cover Certifications and Compliances: NEC/CEC Class I, Divisions and 2, Groups B*, C and D Class II, Division, Groups E, F and G Class II, Division 2, Groups F and G Class III Class I, Zones and 2 UL Standard 203 cul to CSA Standard C22.2 No. 30 ATEX: Ex d IIB + H2 T6, IP66 ATEX certificate: PTB 0 ATEX 020 U Enclosure Type 3, 3R, 4, 4X*, BCD, EFG IEC Standard EN:600-0 and EN:600- Standard Materials: Body and cover copper-free aluminum (suffix -SA items and all ), Feraloy iron alloy (Style D) Gasket neoprene Cover bolts stainless steel (), steel (Style D) Hinges stainless steel Standard Finishes: Copper-free aluminum natural Feraloy iron alloy electrogalvanized and aluminum acrylic paint Steel electrogalvanized Extruded aluminum natural Gasket Detail Cross section of cover. Gasket extends beyond flange surface by.05". EJB2208 with optional hinged cover and standard neoprene cover gasket Options: Description Suffix Hinged covers Hinges mounted on left (short side)... S58 Available on all and the following Style D enclosures: EJB0008-SA, EJB20804, EJB20804-SA, EJB20808-SA, and EJB4006-SA Hinge kits for field installation (no field machining required) EJB KIT EJB00806 through 36208... (2 hinges) EJB KIT 3 EJB36808... (3 hinges) EJB KIT 4 EJB362408... (4 hinges) For EJB0008-SA, EJB20804, EJB20804-SA, EJB20808-SA EJB KIT 5 and EJB4006-SA... (2 hinges) Factory installed mounting plates for relays, terminal blocks, electrical devices, etc. Aluminum mounting plate kit for field installation (kit includes aluminum mounting plate, pillars and mounting hardware). No field machining required. See Ordering Information on next page... MP Factory installed terminal Information blocks... on request ATEX Certified... ATEX Bolted cover and body assembled. Compressed gasket forms watertight seal. *For Group B, install sealing fitting in each conduit run within 8" of the enclosure. To meet 4X requirement, add suffix S52 or S53. EJB36208, 36808, 362408 and all style D enclosures require sealing fittings within 8" of enclosure for each conduit run for Group C locations. Style D enclosures require sealing fittings within 8" of enclosure for each conduit run for Group D locations. 20 www.crouse-hinds.com US: -866-64-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds

EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight Wet Locations Style D Style D Nominal Inside Top & Sides Bottom Cat. # (aa) (bb) Depth Iron EJB060404 4 6 4 EJB080604 6 8 4 EJB080606 6 8 6 EJB080806 8 8 6 EJB20804 8 2 4 EJB60404 4 6 4 Aluminum EJB060404 SA 4 6 4 EJB080604 SA 6 8 4 EJB080606 SA 6 8 6 EJB080806 SA 8 8 6 EJB20604 SA 6 2 4 EJB20804 SA 8 2 4 EJB20808 SA 8 2 8 EJB60404 SA 4 6 4 EJB0008 SA 0 0 8 EJB4006 SA 0 4 6 EJB2208* with optional hinged cover Cat. # Nominal Inside Sides (aa) Top & Bottom (bb) EJB00806 0 8 6 EJB2204 2 2 4 EJB2206 2 2 6 EJB2208 2 2 8 EJB6606 6 6 6 EJB6608 6 6 8 EJB8206 2 8 6 EJB8208 2 8 8 EJB24208 2 24 8 EJB2420 2 24 0 EJB24808 8 24 8 EJB2480 8 24 0 EJB242408 24 24 8 EJB24240 24 24 0 EJB36208 2 36 8 EJB36808 8 36 8 EJB3680 8 36 0 EJB362408 24 36 8 EJB60222 60 22 2 Class I, Div. and 2, Groups C and D only. Depth Ordering Information: Junction boxes listed can be furnished with drilled and tapped openings, subject to material required and the limitations of maximum size and number of openings as well as spacing, as shown in Tables and 2. To Order: Step Select the box required from photos at left, listings, and dimensional drawings on next pages. Step 2 Select standard conduit arrangement from Table and maximum size conduit opening required from Table 2. Step 3 Select appropriate symbol for required drilled and tapped opening from Table 3. Example: Step Box required EJB080806 Step 2 Arrangement 2 Step 3 Openings two " drilled and tapped holes in top and bottom and two 2" drilled and tapped holes on each side. Step 4 Symbols are substituted and written in clockwise order starting with "a." When no opening is required at a particular location, use symbol "0" (zero). For this example: CC, GG, CC, GG. Complete Cat. No. is made up of three parts: Part box number; Part 2 arrangement number; Part 3 symbols for conduit openings. For this example: EJB080806-2-CC-GG-CC-GG If none of the standard arrangements meet requirements, send a sketch showing junction box number with size and location of each conduit opening desired. EJB Mounting Plate Kits (For Field Installation) Select kit number that matches junction box number. Example: EJB-MP40 is used in EJB4006-SA Cat. # EJB MP008 EJB MP22 EJB MP66 EJB MP82 EJB MP242 EJB MP248 EJB MP2424 EJB MP362 EJB MP368 EJB MP3624 Cat. # Style D EJB MP0604 EJB MP0806 EJB MP0808 EJB MP206 EJB MP208 EJB MP604 EJB MP00 EJB MP40 Class I, Div. and 2, Groups C and D only. Plate has no center hole. *See Compliances on previous page. www.crouse-hinds.com US: -866-64-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds 2

EJB Junction Boxes Ordering Information Table Conduit Arrangement Diagrams Table 2 Conduit Arrangements Style D Maximum Trade Size and Number of Openings Top and Bottom (bb)* Sides (aa) Spacing Cat. # 2 3 4 2 3 4 S L2 S2 L3 S3 L4 S4 EJB060404 2 2 2 5 /8 5 /8 /6 2 /8 EJB080604 2 2 /2 2 2 5 /8 2 /8 5 /8 2 3 2 /8 2 /6 EJB080606 3 /2 2 /2 3 /2 3 3 2 5 /8 2 3 2 /8 2 /6 EJB080806 3 /2 2 /2 3 /2 2 /2 3 3 2 2 2 3 2 3 2 /6 2 /6 EJB0008 4 2 /2 /2 4 2 /2 /2 4 3 2 3 2 3 3 5 /8 3 5 /8 2 /6 2 /6 EJB20604 2 2 2 2 /2 2 3 3 5 /8 4 /8 2 /8 3 /8 EJB20804 2 2 2 2 2 /2 2 /8 3 2 4 /8 2 3 3 /6 2 /6 EJB20808 4 4 2 4 2 /2 4 3 3 2 4 /8 2 3 3 /6 2 /6 EJB4006 3 /2 3 /2 2 /2 /2 3 /2 2 /2 /2 3 /8 3 3 2 3 5 3 /6 3 5 /8 2 /6 EJB60404 2 2 2 2 2 2 5 /8 3 /6 6 4 /8 *Top and bottom are longer dimensions on enclosures which are not square. Conduit seals are required in all conduit entrances for Class I, Division, Group B hazardous areas, and for EJB36208, EJB36808, EJB3680, EJB362408, and all Style D enclosures when used in Class I, Division, Group C hazardous areas. For other sealing requirements, consult the National Electrical Code*. Where standard arrangements are not adequate, special drilling and tapping can be ordered, or instructions can be provided for field drilling and tapping. Breathers and drains must be ordered separately. Maximum trade size for Group B application is 4". 22 www.crouse-hinds.com US: -866-64-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds

EJB Junction Boxes Ordering Information Table 2 - Continued Conduit Arrangements - Drilled and Tapped Openings Groups B, C and D Maximum Trade Size and Number of Openings Top and Bottom (bb)* Sides (aa) Cat. # 2 3 4 5 6 8 2 3 4 5 6 8 EJB00806 3 /2 3 /2 3 /2 2 /2 /2 EJB2204 /2 /2 /2 3 /2 /2 /2 3 EJB2206 3 /2 3 /2 /2 3 3 /2 3 /2 /2 3 EJB2208 5 3 /2 /2 3 5 3 /2 /2 3 EJB6606 3 /2 3 /2 2 /2 2 /2 3 3 /2 3 /2 2 /2 2 /2 3 EJB6608 5 5 3 2 /2 3 5 5 3 2 /2 3 EJB8206 3 /2 3 /2 3 /2 2 /2 /2 /2 3 3 /2 3 /2 /2 3 EJB8208 5 5 3 /2 2 /2 2 /2 5 3 /2 /2 3 EJB24208 5 5 5 3 /2 3 2 /2 2 /2 5 3 /2 /2 EJB2420 6 6 5 3 /2 3 2 /2 2 /2 6 3 /2 /2 EJB24808 5 5 5 3 /2 3 2 /2 2 /2 5 5 3 /2 2 /2 2 /2 EJB2480 6 6 5 3 /2 3 2 /2 2 /2 6 6 3 /2 2 /2 2 /2 EJB242408 5 5 5 3 /2 3 2 /2 2 /2 5 5 5 3 /2 3 2 /2 2 /2 EJB24240 6 6 5 3 /2 3 2 /2 2 /2 6 6 5 3 /2 3 2 /2 2 /2 EJB36208 5 5 5 5 4 4 3 /2 2 /2 5 3 /2 /2 3 EJB36808 5 5 5 5 4 4 3 /2 2 /2 5 5 3 /2 2 /2 2 /2 EJB3680 6 6 5 5 4 4 3 /2 2 /2 6 6 3 /2 2 /2 2 /2 EJB362408 5 5 5 5 4 4 3 /2 2 /2 5 5 5 3 /2 3 2 /2 2 /2 Spacing Cat. # S L2 S2 L3 S3 L4 S4 L5 S5 L6 S6 L S L8 S8 EJB00806 3 3 /8 2 3 /8 3 2 3 /8 2 3 EJB2204 3 2 2 3 5 /8 3 5 /8 3 /6 3 /6 2 2 3 3 /2 EJB2206 3 3 3 3 3 5 /8 3 5 /8 3 /6 3 /6 2 2 3 3 /2 EJB2208 4 3 3 3 3 5 /8 3 5 /8 3 /6 3 /6 2 2 3 3 /2 EJB6606 3 3 3 3 4 5 /8 4 5 /8 4 3 /6 4 3 /6 2 3 2 3 2 /2 2 /2 2 2 3 3 EJB6608 4 3 3 3 4 5 /8 4 5 /8 4 3 /6 4 3 /6 2 3 2 3 2 /2 2 /2 2 2 3 3 EJB8206 3 3 3 3 6 3 5 /8 4 5 /8 3 /6 2 3 2 2 3 3 2 /2 3 EJB8208 4 3 4 3 /6 3 6 3 5 /8 4 5 /8 3 /6 3 2 2 3 3 2 /2 2 EJB24208 5 /8 4 3 /6 3 8 /6 3 5 /8 6 3 /6 4 5 /8 2 3 /8 2 3 /2 2 3 EJB2420 6 /8 4 3 3 8 /6 3 5 /8 6 3 /6 4 5 /8 2 3 /8 2 3 /2 2 3 EJB24808 5 4 3 /6 4 3 /6 8 /6 6 6 4 5 /8 4 5 /8 3 3 /8 2 3 3 2 /2 2 3 2 EJB2480 6 4 3 4 3 8 /6 6 6 4 5 /8 4 5 /8 3 3 /8 2 3 3 2 /2 2 3 2 EJB242408 5 3 /8 4 3 /6 4 3 /6 8 /6 8 /6 6 6 4 5 /8 4 5 /8 3 /8 3 /8 3 3 2 3 2 3 EJB24240 6 3 /8 4 3 4 3 8 /6 8 /6 6 6 4 5 /8 4 5 /8 3 /8 3 /8 3 3 2 3 2 3 EJB36208 4 3 4 /6 3 8 /6 3 5 /8 8 /6 3 /6 5 3 2 5 3 3 5 /8 /2 3 /8 EJB36808 5 /2 4 /6 4 /6 8 /6 6 8 /6 4 5 /8 5 3 3 5 3 2 3 5 /8 2 /2 3 /8 2 EJB3680 6 /2 4 3 4 3 8 /6 6 8 /6 8 /6 5 3 3 5 3 2 3 5 /8 2 /2 3 /8 2 EJB362408 6 4 3 4 3 /6 8 /6 8 /6 8 /6 6 5 3 4 5 /8 5 3 3 /8 5 /8 3 3 /8 2 3 Conduit seals are required in all conduit entrances for Class I, Division, Group B hazardous areas, and for EJB36208, EJB36808, EJB3680, EJB362408, and all Style D enclosures when used in Class I, Division, Group C hazardous areas. For other sealing requirements, consult the National Electrical Code*. Where standard arrangements are not adequate, special drilling and tapping can be ordered, or instructions can be provided for field drilling and tapping. Breathers and drains must be ordered separately. Maximum trade size for Group B application is 4". Table 3 Symbols for Openings Conduit Size Drilled and Tapped Hole Symbol /2 A 3 B C E /2 F 2 G 2 /2 H 3 J 3 /2 K 4 L 5 M Maximum trade size for Group B applications is 4". *Top and bottom are longer dimensions on enclosures which are not square. 6 N Spacing dimensions for Group B boxes are based on use of EYS-0 sealing fitting in conduit. None 0 www.crouse-hinds.com US: -866-64-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds 23

EJB Junction Boxes In Inches: A B C D E Table 4 Outside Cat. # Diagram aa bb Mtg. Hole ww xx yy zz Net Weight (lbs.) w/ Cover EJB060404 8 /32 0 /32 EJB080604 0 5 /32 2 5 /32 EJB080606 0 5 /32 2 5 /32 EJB080806 2 5 /32 2 5 /32 EJB20804 2 /2 6 /2 EJB60404 8 /2 20 /2 EJB060404 SA 8 A, /32 0 /32 EJB080604 SA 0 B, /32 2 5 /32 EJB080606 SA 0 D /32 2 5 /32 EJB080806 SA 2 5 /32 2 5 /32 EJB20604 SA 0 /2 6 /2 EJB20804 SA 2 /2 6 /2 EJB20808 SA 2 /2 6 /2 EJB60404 SA 8 /2 20 /2 EJB0008 SA 4 2 /32 4 2 /32 EJB4006 SA 4 2 /32 8 2 /32 /6 8 3 6 /8 5 /8 43 /6 0 25 /32 6 3 /6 /8 64 /6 0 25 /32 8 3 /6 /8 84 /6 2 25 /32 8 /32 /8 8 /6 2 3 /6 6 3 /8 /8 03 /6 8 3 /6 6 5 /32 5 /8 86 /6 8 3 6 /8 5 /8 6 /6 0 25 /32 6 3 /6 /8 24 /6 0 25 /32 8 3 /6 /8 32 /6 2 25 /32 8 /32 /8 3 /6 0 3 /6 6 3 /6 /8 32 /6 2 3 /8 6 3 /8 /8 3 /6 2 3 /6 0 3 /8 /8 56 /6 8 3 /6 6 5 /32 5 /8 33 /6 4 /8 0 3 /8 3 /8 5 /6 4 /8 8 5 /32 3 3 /8 66 EJB00806 3 /32 5 /32 EJB2204 /6 /6 EJB2206 /6 /6 EJB2208 /6 /6 EJB6606 2 3 /6 2 3 /6 EJB6608 2 3 /6 2 3 /6 EJB8206 C /6 23 5 /6 EJB8208 and /6 23 5 /6 EJB24208 E /6 2 /6 EJB2420 /6 2 /6 EJB24808 23 /6 2 5 /8 EJB242408 2 /6 2 /6 EJB24240 2 /6 2 /6 EJB36208 /6 4 /6 EJB36808 23 5 /6 4 5 /6 EJB3680 23 5 /6 4 5 /6 EJB362408 30 3 /6 42 3 /6 /6 2 8 /6 5 /2 60 /6 6 /8 6 3 /6 5 /2 5 /8 60 /6 6 /8 8 /8 5 /2 5 /8 0 /6 6 /8 0 /8 5 /2 5 /8 80 /6 20 /8 8 /8 /2 /8 03 /6 20 /8 0 /8 /2 /8 3 /6 6 /8 8 /8 /2 5 /8 0 /6 6 /8 0 /8 /2 5 /8 0 /6 6 /8 3 /2 5 5 /8 4 /6 6 /8 3 3 /2 5 5 /8 60 /6 23 /2 2 2 /8 243 /6 2 /2 2 5 /6 6 2 /8 26 /6 2 /2 4 5 /6 6 2 /8 322 /6 6 /8 /6 2 /2 5 /8 85 /6 23 /2 2 /6 28 2 /8 35 /6 23 3 4 28 2 /8 36 /6 3 2 5 /8 28 2 /2 5 24 www.crouse-hinds.com US: -866-64-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds

EJB Junction Boxes Mounting Plate Table 5 Mounting Plate Cat. # a b c d e f g h j k EJB MP008 0.25 5 3 /8 /2 EJB MP22 0.25 3 /8 /2 EJB MP66 5 5 0.25 3 3 3 /8 /2 EJB MP82 0.25 3 8 /2 5 /2 2 3 /8 2 /2 2 EJB MP242 23 0.25 /2 5 /2 2 3 /8 2 /2 2 EJB MP248 22 6 0.25 3 8 /8 2 /2 EJB MP2424 22 22 0.25 /8 2 /2 EJB MP362 34 0 0.25 3 5 /8 2 /2 EJB MP368 33 /2 5 /2 0.25 3 3 6 3 3 5 /8 3 EJB MP3624 34 22 0.25 3 /8 2 /2 Plate has no center hole. *Certifications and Compliances, see page 20. www.crouse-hinds.com US: -866-64-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds 25