www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

Similar documents
BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

BBC. Installation/Maintenance Instructions I-T-E Low-Voltage Power Circuit Breakers

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Controlled Power HSN High Speed DC Circuit Breakers

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

www. ElectricalPartManuals. com

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

Installation Sheet January, 2016 Supersedes February, 2013

K-Line Plus Types KP-32, KPE-32, KP-40 and KPE-40

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

K-Line Plus Type KP-8 thru KP-20

www. ElectricalPartManuals. com RENEWAL PARTS DATA Westinghouse Electric Corporation WESTINGHOUSE EQUIPMENT FOR FURNISHED TO

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t

Bussmann series Quik-Spec Power Module Switch elevator disconnect

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

Horizontal Circuit Switchers

Horizontal Circuit Switchers

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

Type SOQ Negative Sequence Time Overcurrent Relay

SECTION DC POWER SUPPLY/BATTERY CHARGER

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

SECTION MOTOR CONTROL

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

Type CRN-1 Reverse Power Relay 50 and 60 Hertz

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

Installation Sheet January, 2016 Supersedes June 2013

CR193 B,C,D and E Vacuum Limitamp * Contactors

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1

POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

A. Submit manufacturer's literature and technical data before starting work.

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Instructions for Replacing

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

INSTRUCTIONS. seconds. the tween the end of the bearing screw and the. top of the shaft. The moving contact is a small silver hemisphere

Vacuum Circuit Breaker Type VAD-3

www. ElectricalPartManuals. com Instructions for Ground Fault Protection Systems INTRODUCTION SENSOR Fig. 1 Cu"ent Monitor

PowlVac Type PV STD/CDR Vacuum Circuit Breaker

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

COM Overcurrent Relay

Digitrip Retrofit System for BBC LKD 8 Breakers

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

IB PowlVac CDR Vacuum Circuit Breaker. 5kV & 15kV 1200A, 2000A, & 3000A. Powered by Safety

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

www. ElectricalPartManuals. com INSTRUCTIONS INTERLOCKED MOTOR-DRIVEN OPERATING MECHANISM For No-Load Tap Changers DESCRIPTION OPERATION MAINTENANCE

University of Houston Master Construction Specifications Insert Project Name

Medium Voltage Metal-Enclosed Switches

Critical Power Switchboards. Selection and Application Guide

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Selection Guide. Control Circuit and Load Protection

ABB ADVAC TM. INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

~

920 Remote Control Switches

Powered by Safety 01.4IB.77000B PowlVac-ND Vacuum Circuit Breaker

B CW POWER RELAY

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

DETAIL SPECIFICATION SHEET

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

SECTION MOTOR CONTROLLERS

Bolted contact switches. Pringle switches

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

Magnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data

Electromagnetic Industries LLP

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

Washer-Extractor. Parts. Cabinet Freestanding. See Page 3 for Model Numbers R001C P/N

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers

WL Low Voltage Metal-Enclosed Switchgear

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Transcription:

i BBC BROWN BOVERI Type LK and LKE 800 thru 4200 Amperes Type LKD 800 and 1600 Amperes 600 Volts RP 6118A Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers Brown Boveri Electric

RP 6118-1A Page 2 Introduction TABLE OF CONTENTS Recommended Quantities Ordering Instructions Circuit Breaker Components Accessories 4-9 10-11 Cradle Components The photographs reproduced in this bulletin are furnished only to serve as a guide in the identification of assemblies and parts, and do not purport to cover all details or variations in equipment 10-12

INTRODUCTION These renewal parts apply to types LK and LKE Circuit Breakers with AC continuous ratings of 800, 1600, 2500, 200, and 4200 amperes and type LKD with AC continuous ratings of 800, and 1600 amperes A supply of renewal parts is recommended to insure proper and timely maintenance for normal operation of the circuit breakers The minimum quantity of assemblies and items recommended in this bulletin is predicated on infrequent replacement of parts based on accumulated tests and operating experience Total assemblies are recommended for fast replacement, to return the breaker to service as quickly as possible For assistance, contact the nearest District Office RECOMMENDED QUANTITIES 1 Minimum Recommended Quantities are based on the following categories of service: Domestic One (1) complete set for each ten (10) circuit Foreign Note: breakers or fraction thereof installed for each type and rating One (1) complete set for each five (5) circuit breakers or fraction thereof installed for each type and rating Renewal Parts Listing cover all types and ratings of circuit breakers Use caution in selecting parts to assure they are applicable to the circuit breaker(s) on hand 2 The parts listed cover an indefinite period of time With normal duty and maintenance, replacement will be infrequent Where continuity of service is mandatory, a spare circuit breaker of each type and rating is recommended ORDERING INSTRUCTIONS RP 6118-1 Page When ordering, always specify circuit breaker type(s) and serial number(s) from the nameplate(s), in addition to the quantity, description, and ordering number of each assembly or part, as applicable Example: To order Lower Terminal and moving Contact assemblies for a type LK 8 Drawout Circuit Breaker, specify the following: For a type LK 8 Drawout Circuit Breaker Serial No 54000A - 212-01211 Quantity Number 71907-T7 Lower Terminal and Moving Contact Assembly Only those parts that normally require replacement have been shown and listed If the part(s) required are not listed, completely describe the part(s), using reference in the instruction sections, actual photographs or a sample ADDITIONAL INFORMATION For FO R PRICES AND TECHNICAL INFORMATION, CONTACT OU R NEA REST DIST RICT OFFICE Installation/Maintenance Instructions for 1-T-E Low Voltage Power Circuit Breakers see IB 61 1 7-1 For Installation/Maintenance Instructions for 1-T-E Low Voltage AC Metal Enclosed Power Switchgear see IB 117-1

RP 6118-1 Page 4 CIRCUIT BREAKER COMPONENTS Description of Assembly or Part Upper Terminal Assem (includes stationary main & arc contact) Lower Terminal & Moving Cont Assem (includes moving main & arc contacts) Moving Contact Assem (Bridge Blade, includes main & arc contacts) Operating Mechanism Small Large Phase Sensor Arc Chute Man Oper Elec Oper Man Oper Elec Oper 200A 800A 1600A 2500A 000A 200A 4000A 4200A Fig Ref 1A 18 18 1C Not Illustrated 2A 28 28 28 2C 2C Not Illustrated A 8 4A 4A 5A 58 6A 68 Quantities Per Type CCLnNN -NM<:t CIOWWWW w 1111 1 CCLnNN co-nm<:t 11111 6 6 6 6 1 1 1 1 1 1 1 1 1 1 Fused cc coco I I - 1 1 1 1 Ordering Number 71908-T7 T8 T T4 T10 T11 71907-T7 T8 T T4 T5 T6 T10 T11 71482-K2 71470-K2 71911-T T4 T5 T6 - - - 401740-K4 - - - - K5 K6 401717-K6 K7 K8 K9 K10 712207-T2 T

RP 6118-1 Page 5

RP 6118-1 Page 6 CIRCUIT BREAKER COMPONENTS (Continued) Add Suffix to Oreding Number DC 50/60Hz Quant Per > > > 0 0 0 Circuit """ co 0 N """ Description for Types Fig to Ordering > > > > -- -- -- Breaker > > I!) 0 0 co 0 0 0 LK, LKE and LK D Number (Options) Ref """ co N I!) N 0 N """ I!) N """, N, N N """ I!) Shunt Trip Assem 7A 712214 T9 T6 T7 T8 T1 T T 1 (Eiec Oper & Option on Man Oper) Close Coil Assem SA 712217 T6 T7 T8 T1 T T 1 (Eiec Oper Only) "Y" Relay Assem 9A 712218 - T6 T7 T8 I T1 T T - 1 (Eiec Oper Only) Motor Assem 10A 709799- T8 T6 T7 TG T7 T7 1 (Eiec Oper Only) Undervoltage Trip Device 11A 712215- T9 T6 T7 T8 T1 T2 T T4 T5 ( 1) (Option) UV Lockopen 712216-T9 (Option for UV Device) ( 1) Uv Trip defeator 712216-T7 (Option for UV Device) ( 1) Close & Trip Switch 12A 712780-A (Option for Elec Oper) ( 1) Alarm Switch (Auto Trip) 1A 71008-A (Option) ( 1 or 2) Auxiliary Switch (L) 14A 712210-T1 Elec, or Man Oper with Shunt Trip 1 Limit Switch (LS1 &) 15A 71916-T2 Electrical Operation Only 1 Limit Switch (LS-2) 15B 71916-T1 Electrical Operation Only 1 Motor Disconnect Switch 16A 70270-A Electrical Operation Only 1 Operation Counter 17A 180522-A (Option) ( 1) Secondary Disconnect 18A 712208-T1 No Guide As Req'd Moving (7Contact) 18 B 712208-T Single Guide As Req'd 18C 712208-T4 Double Guide As Req'd

RP 6118-1 Page 7

RP 6118-1 Page 8 CIRCUIT BREAKER COMPONENTS (Continued) Quantity per type DESCRIPTION Fig Ordering LKD 8 LKD 16 Ref Number Open Fuse Trip Device 1 1 19A 712219-T1 Amp Trap Fuse* 00A 71016-A1 *Warning: Fuse is current limiting and must be coordinated with LSS Trip Device (Listed is Type 55 AL, Style "Y" Form 480 AMP Trap) 400 A2 600 A 800 A4 1000 20A A5 1200 A6 1600 A7 2000 AS 2500 712652-A Basic No Ground Add Suffix to Basic Order No (Sensor Ratings) Quantity Trip With Ground Trip Per With Fig Order 200A to 200A BOOA 1600A 2500A 000 4000 Breaker Type Description Type Ref No 4200A 200A 4200A Solid State Trip Unit LSS1 21A 611090 - T01 T11 T21 T1 T41 T51 TG1 LSS 1G (without targets) LSS2 G11090- T02 - - - - - - - (without ground) LSS4 61107- T04 T11 T14 T21 T24 T1 T4 Circuit Ground LSS-4G LSS5 G1107- T05 T12 T15 T22 T25 T2 T5 LSS-G LSSG G1107- TOG T1 T1G T2 T26 T TG 1 LSS-6G Solid State Trip Unit LSS4 - G11250- T04 T11 T14 T21 T24 T1 T4 LSS-4G (with targets) LSS5 6 1 1250 - T05 T12 T15 T22 T25 T2 T5 LSS-5G (without ground) LSSG G11250- TOG T1 T1G T2 T2G T TG LSS-GG Auxiliary Static Units (optional) - Control Power Not available for LSS1 & 2 1 40VAC 125VAC 120VAC 250VDC 48VDC Load Alarm 22A G110G8 - T01 T01 T01 T01 T48 Ground Trip Alarm 22A G110G8- T02 T02 T02 T02 Remote Neutral Sensor T49 ircuit Breaker Sensor Rating (Amperes) Mounting I D Bus Window two 800 1GOO 2500 000 200 4000 4200 Bars (max) Width (4-wire ground) - 40178G K1 K2 K K4 K5 KG K7 K8 (1)Y,"x4" 4%" 1 Control Cable Assembly 2A 401781 - - - K1 K2 K K4 K5 ()Y"xG" GY" Standard (9 wire) G11080- T01 T0 Special (for use with 1 Load or G Trip Alarm) G11080 - T02 T04 Magnetic Latch 24A 71229 - T15 ALL RATINGS 1 Trip Unit Transparent Cover - G11092 - A ALL RATINGS 1 (Remote)

, 1 RP 6118-1 Page 9

RP 6118-1 Page 10 ACCESSORIES: Fig Ordering Type Description Ref Number LK, LKE, LKD, Racking Crank 25A 712229-T6 LK, LKE, LKD 8 & 16 Lifting Yoke 258 712229-T7 LK, LKE 25 to 42 Lifting Yoke 25C 712229-T8 CRADLE COMPONENTS: Shutter Assem Quantities Per Type: Fig LK, LKE, LKD LK, LKE 25 to 42 Ordering Description Ref 8 or 16 Number Large 26A - 1 712250-T2 Small 268 1-712250-T1 Position Indicator Kit (Optional) 27A 1-712224-T1 MOC Switch Kit (Optional) - 712224-T14 Actuator 28A i Operates Connected Position 1 1 712224-T11 Operates Connected & Test Position 1 1 712224-T12 Switch Includes Mounting & Crank 288 4 Contact ( L2) or 1 1 712224-T1 8 Contact ( L2) Max (shown) 1 1 712224-T2 TOC Switch Kit (Optional) 29A 4 Contact ( L2) Standard* 1 1 712225-T1 8 Contact ( L2) Standard* 1 1 712225-T2 4 Contact Special** 1 1 712225-T 8 Contact Special** 1 1 712225-T4 4 Contact - Standard and 4 1 1 712225-T5 Contact - Special (Shown) * Operates between Test and Connected Positions ** Operates between Test and Disconnect Positions Auxiliary Switch Assem(Optional) 0A 4 Contact (L2) (Shown) 1 1 70004-K1 8 Contact (L2) 1 1 70008-K1 Secondary Disconnect (As Required) Stationary (7 Contact) 1A 0 to 4 0 to 4 712209-T2 Insulation Strip-Secondary Disconnect "TP" Function - (As Required) (As Required) 712692-A Short Contact-Secondary Disconnect "OP" Function - (As Required) (As Required) 71268-A Transparent Door Mounted Position Indicator Cover (Optional) - 1 1 8812-A Emergency Trip Button- Door Mounted (Optional) - 1 1 8821-T1 ---

' t RP 6118-1 Page 11

RP 6118-1 Page 12 CRADLE COMPONENTS Description Ref 8 or 16 Current Transformer: Quantities Per Type: Fig LK, LKE, LK D LK, LKE 25 to 42 Ordering Number Type LKM-1 100/5 A 2A Oto 401775-K1 150/5 A K2 200/5 A K 00/5 A K4 400/5 A K5 500/5 A K6 600/5 A K7 800/5 A K8 1000/5 A K9 1200/5 A K10 1500/5 A K11 1600/5 A K12 2000/5 A K1 2500/5 A K14 Type LKM-2 2000/5 A 28 Oto 40179-K1 2500/5 A K2 000/5 A K 4000/5 A K4 5000/5 A K5 6000/5 A K6

NOTES RP 6118-1 Page 1

RP 6118-1 Page 14 NOTES

NOTES RP 6118-1 Page 15

BBC BROWN BOVERI Brown Boveri Electric, Inc Switchgear Products Division Spring House, PA 19477 Supersedes IB 6117 Issue A Printed in USA M CMC 68