EchoPod. Technical Support. Model: DL14-(XX) Quick Start

Similar documents
LU27 Series Quick Start

EchoPod. DL10, DL14, DL24, DS14 & DX10 Series Quick Start. DL14-00 Shown Flowline, Inc. All Rights Reserved Made in USA

LU23, LU28 & LU29 Series Quick Start

EchoPod. UG01 & UG03 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Ultrasonic Liquid Level Switch, Controller & Transmitter

EchoPod. UG06 & UG12 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Ultrasonic Liquid Level Transmitter

XP88 & XP89 Series Quick Start

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

EchoPod DL14, DL24 & DL34 Series Manual Revision A.3

EchoSonic. LU23, LU27, LU28 & LU29 Series Manual. Ultrasonic Liquid Level Transmitter

Smart Trak. AU18, AU28, AU38, AU48, AV16, AV26, AV36, AV46, AZ18, AZ28, AZ38 & AZ48 Series Owner s Manual. w/ Compact Junction Box

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

EchoPod. DL10, DL14, DL24, DL34, DS14, DX10 Series Manual. Ultrasonic Liquid Level Transmitter, Switch and/or Controller

Switch Pro Remote Level Controller LC40, LC41 & LC42 Series Manual

Thermo Flo Thermal Dispersion Flow Switch FT10 & GT10 Series Manual

Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual

Configuring the Cost-Effective Ultrasonic Liquid Level Sensor

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

Series ULS Small Tank Ultrasonic Transmitter, Switch and Controller Series ULSS, ULSM, ULSL Manual

EchoPod. UG06 & UG12 Series Manual. Ultrasonic Level Transmitter

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

LA19 Series Ricochet Battery Powered Level Transmitter and Display

WiFi Tank Level Monitor Installation Instructions

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

PVI 60KW, PVI 82KW, PVI 95KW

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Installation & Operators Manual

Installation Instructions

Smart -Trak. AU23, AV23, AZ23 Series Manual. With Compact Relay Controller

AGCO. Corn Header Manual d HEADSIGHT.COM

Installation Instructions

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

Installation Instructions

Operating and Installation Instructions

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -

Power. On Your Terms.

10 Year Limited Warranty

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Railway. assembly instructions. data and power solution. model# RAIL-LINEAR model# RAIL-90 model# RAIL-BULLPEN model# RAIL-3WAY model# RAIL-4WAY

CORN HEADER MANUAL: CNH PRE-2012

E24/E28 M30 Mass Air Flow Conversion System Instruction Manual Version 2.0

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

HPx-JDx3-xx HARNESS INSTALLATION

Active Controlled Cooling System

RANGE HOODS USER INSTRUCTIONS

Installation Instructions

Installation Instructions

DRAGO. Corn Header Manual f HEADSIGHT.COM

Users Guide for Ac-sync

E24-E28 M88 & S38 Mass Air Flow Conversion System Instruction Manual

HR-20P Pneumatically Controlled Pressure Regulator

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

GERINGHOFF. Corn Header Manual f HEADSIGHT.COM

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

Read and follow all instructions. Safety can only be ensured if the walker is assembled and operated according to these instructions.

Installation Instructions

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

END USER TERMS OF USE

StormPro BA Series Sump Pump

INSTALLATION MANUAL DURAMAX DIESEL POWERED PICKUP TRUCKS MODEL RP-100 & RP-150. With New Quick Connect Components!

Broadband PowerShield. CP27U Models. User Manual

Franklin Fueling Systems

6.0L Ford Powerstroke 2003 THROUGH 2007

INSTALLATION MANUAL #29 FOR CHEVY DIESEL PICKUP TRUCKS. MODEL RP-100 & RP-150 With New Quick Connect Components

Installation Instructions

24V Solar Charger. Instructions READ CAREFULLY Garrymore Ln Missoula, MT

Installation Guide. Marine Filter SURT023M SURT024M

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

LEXION SINGLE FUNCTION HYDRAULIC VALVE KIT

WARNING. Instructions for Guidelights and Chargers. How SnapPower Products Work

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

All products subject to this warranty must be returned for examination, repair or replacement to:

Installation Instructions

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

WEB CONTROL PRODUCTS

7.3L Ford PowerStroke

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Installation Instructions

200w Performance Series 2-CH Amplifier Kit For Harley Street Glide/Ultra/Ultra LTD. Fairing JMAA-2000HC14

Cabling for power, control, and video must be run to the installation site before the mount is installed.

Installation Instructions

ATTENTION: PLEASE READ AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS BEFORE ASSEMBLING, INSTALLING OR USING THIS PRODUCT.

Use/Installation Guide

Installation Instructions

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

Installation Instructions

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

Turbo-House Air Inlet Installation & Operator s Instruction Manual

INSTALLATION AND OPERATION MANUAL

HDI inch Choke Position Indicator User s Manual Rev Indicator Gauge Linear Potentiometer

LIFT NAME PART NUMBER SETBACK (min) SETBACK (max)

AMES 2016 Price List. Backflow Prevention Products and Repair Kits and Parts. Effective February 29, 2016

CAUTION: Read manual carefully for proper procedures and operation.

CRD610 Automatic Fitting Inserter

Hydraulic Air Pump. Operating Instructions & Parts Manual. Capacity 10,000 PSI. Model Number Atd-5812

Transcription:

Technical Support For complete product documentation, video training, and technical support, go to www.flowline.com. For phone support, call 562-598-3015 from 8am to 5pm PST, Mon - Fri. (Please make sure you have the Part and Serial number available.) Flowline Inc. 10500 Humbolt St, Los Alamitos, CA 90720 Warranty Flowline warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Flowline for a period, which is equal to the shorter of one year from the date of purchase of such products or two years from the date of manufacture of such products. Flowline's obligation under this warranty is solely and exclusively limited to the repair or replacement, at Flowline's option, of the products or components, which Flowline's examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Flowline must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired or replaced under this warranty will be warranted only for the remainder of the original warranty period. Returns Products cannot be returned to Flowline without Flowline's prior authorization. To return a product that is thought to be defective, go to www.flowline.com, and submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns to Flowline must be shipped prepaid and insured. Flowline will not be responsible for any products lost or damaged in shipment. Limitations This warranty does not apply to products which: 1) are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2) have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3) have been modified or altered; 4) anyone other than service personnel authorized by Flowline have attempted to repair; 5) have been involved in accidents or natural disasters; or 6) are damaged during return shipment to Flowline. Flowline reserves the right to unilaterally waive this warranty and dispose of any product returned to Flowline where: 1) there is evidence of a potentially hazardous material present with the product; or 2) the product has remained unclaimed at Flowline for more than 30 days after Flowline has dutifully requested disposition. This warranty contains the sole express warranty made by Flowline in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL FLOWLINE BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF FLOWLINE. This warranty will be interpreted pursuant to the laws of the State of California. If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty. QS300210 Rev.B 2010 Flowline, Inc. All Rights Reserved Made in USA Model: DL14-(XX) EchoPod Quick Start 10500 Humbolt Street, Los Alamitos, CA 90720 USA Tel: 562.598.3015 Fax: 562.431.8507 www.flowline.com

Welcome to the DL14 Quick Start The DL14 Quick Start is meant to show some of the more common setup solutions to getting the DL14 up and running quickly. If you run into an issue that is not addressed here or wish to install or set up with a non-standard configuration, please address the DL14 Manual or refer to the Flowline website at www.flowline.com. We Do Your Level Best Thank you for purchasing the EchoPod (DL14). This general purpose ultrasonic sensor provides non-contact detection with 4 SPST 60 VA 1A relays powered by the 4-20 ma loop. This Quick Start includes everything you ll need to get the EchoPod up and running. For complete information, please refer to EchoPod documentation located at www.flowline.com. Components Depending on how the EchoPod was shipped to you, you may or may not have the components shown below. All three components, including the EchoPod, USB Fob, and Viton gasket are required to configure and install the EchoPod. If you need any additional components, you can order them directly from your local Flowline distributor. General notes for electrical connections, usage and safety: Typical Wiring Diagram Your WebCal Wiring Diagram may vary. Where personal safety or significant property damage can occur due to a spill, the installation must have a redundant backup safety system installed Wiring should always be completed by a licensed electrician Supply voltage should never exceed 28 VDC Always use stepper relays between the sensor and external loads. For DC circuits use a catch diode such as 1N4148, as shown above. Protect the sensor from excessive electrical spikes by isolating the power, whenever possible EchoPod DL14-0 DL14-1 USB Fob LI99-1001 Viton gasket 204038 The sensor materials must be chemically compatible with the liquids to be measured Design a fail-safe system for possible sensor and/or power failure Never use the sensor in environments classified as Hazardous

Wiring the EchoPod After mounting the EchoPod, make the necessary electrical connections. A wiring diagram with specific recommendations for the sensor s configuration can be printed from the WebCal program. A typical wiring diagram is shown on the next page. Configuring the EchoPod Configuration of your EchoPod should be performed prior to mounting, since it requires connection to your PC. Step 1: Install the WebCal Software Download WebCal from www.flowline.com onto a PC with the following minimum specifications: Windows 2000/XP/Vista/7, 10 MB storage space, 256 MB RAM, 1 USB 2.0 port Double-click the WebCal icon to install before proceeding to Step 2. You must have an active Internet connection to install WebCal, as it will automatically verify driver updates. Step 2: Connect the USB Fob NOTE: Do not connect the Fob until after you ve installed WebCal. Red and Black leads are for connection to a 24 VDC power supply or to a 4-20 ma loop power source. The red and black wires can be extended more than 1000 feet using 22 gauge or larger wire, however do not extend the green and white wires. White and Green leads are reserved for use with WebCal and should not be connected during usage in the application. These wires should not be connected to WebCal while power is supplied from any source other than the LI99 FOB. Never allow the white or green wires to touch any power supply. Blue, Orange, Yellow and Purple wires are the relay contacts (normally open) from each of the relays respectively. The Brown wire is the common for all of the relays. The EchoPod communicates to its configuration software through the USB Fob. Prior to connecting the Fob, ensure that all external power is disconnected from the EchoPod as power is provided through the PC s USB 2.0 port. Do not use a cable connecting the EchoPod to the Fob any longer than 15 feet. 1) Connect the red, green, white, and black wires from the EchoPod to the corresponding colored terminals on the Fob (as shown in the diagram). 2) Tighten the terminal screws with a slotted screwdriver. 3) Plug the Fob into your PC s USB port.

Step 3: Configure through WebCal These instructions will walk you through configuration of the EchoPod through WebCal. For more information, click the WebCal HELP button in the lower right corner or anywhere on the WebCal screen or refer to the EchoPod Manual found at www.flowline.com. Using a Standpipe A standpipe may be used to dampen turbulence, separate surface foam from the point of measurement or increase performance in heavy vapor. Select a 3 pipe (a 2 pipe is usable, but the minimum) and attach the EchoPod with a coupling and reducer bushing. The pipe length should run the measurement span and the bottom of the pipe should remain submerged at all times to prevent foam from entering the pipe. Cut the bottom end of the pipe at 45 and drill a 1/4 pressure equalization hole high in the dead band. The pumps should not drive liquid past the open end of the standpipe which causes the liquid in the pipe to become turbulent. WebCal Configuration Screen Mounting with a Standpipe

Mounting the EchoPod The EchoPod should always be mounted perpendicular to the liquid surface and installed using the provided Viton mounting gasket. Always use fittings, with thin wall mounting structures that isolate the transducer. This will provide the best performance over the lifetime of the product. The preferred mounting fitting for the EchoPod DL14 is the reducer bushing LM52-1400 (2 thread x 1 thread). Further mounting products and solutions can be found on the Flowline website at www.flowline.com/fittings.php. An instructional video on mounting ultrasonic level measurement technology is also available on the website. Using the drop-down menus on the left of the WebCal screen, set the configuration for your application requirements. When a selection does not apply to your application, Not Applicable will appear in the drop-down. Make sure all drop-downs are set appropriately for your application before moving to the Tank Level section. NOTE: If you would like to start over, click the Clear Screen button on the right. For installations in existing 2 fittings: Use LM52-1400 2 thread x 1 thread adapter. (An adapter with an air gap around the 1 inch threads as shown is recommended) For installations in plastic tanks: 1) Use a Bulkhead fitting LM52-1890 1 Bulkhead fitting, 2) Use a Bulkhead fitting LM52-2890 in combination with LM52-1400 or, 3) Weld a plastic 1 half coupler to tank top. Enter the appropriate tank level set points for your application. Configuration Settings For installations in metal tanks: 1) Use the recommended bulkhead fittings as shown above or a LM52-1850 1 Flange. The flange fitting must have a riser for the threaded section. Drilling and tapping a blind flange is not recommended. 2) While installations directly into a 1 metal fitting are not recommended, acceptable results may be obtained if the 1 fitting is a half coupling in form and the outer diameter of the coupler is tightly wrapped in vinyl tape to dampen vibrations. For installations in open tanks and sumps: Units. Display measurements in inches or centimeters. Sensor Height. Distance measured from the bottom of the empty tank to the bottom of the transducer. Under factory configuration, this becomes the 4 ma set point. Fill Height. Distance measured from the bottom of the empty tank to the maximum fill height within the tank. Under factory configuration, this becomes the 20 ma set point. Relay Set Points. Distance measured from the bottom of the empty tank to each relay set point. Tank Level Settings 1) Use Flowline's LM50-1001-1 side mount bracket, which includes a 2" x 1" thread reducer bushing.

The options on the right of the WebCal screen to finalize the configuration. Before configuration can be completed: You must click the Write to Unit button to save the settings to the unit. Write to Unit. Send your configuration into EchoPod. Wiring Diagram. Open PDF wiring schematic of your configuration. Advanced. Configure advanced settings. Read the section below on advanced setting options Factory Config. Return EchoPod to the original factory configuration. Clear Screen. Clears the screen of configuration settings. Config File. Name, save, open or print your configuration for later use. Finalize Settings Then, click Wiring Diagram for a hard copy of the EchoPod s settings. Finally, enter the file name under which you wish to save the configuration file and click Save Config File. Configuration is now complete. Disconnect the USB Fob before continuing to the next step: Mounting the EchoPod. The Advanced button is used for options available when setting up the sensor with special, non-standard features. Many of these features are available for specific applications that may change from time to time. Consult WebCal's HELP file for the latest information on the use of any of these features. For updates to WebCal, or to make sure you re using the most up-to-date version available, click the Update tab on the top of the WebCal screen. The more commonly used Advanced features are the Invert Relay and Increase Output Filtering described below. Increase Output Filtering. Select this radio button to add additional filtering to the 4-20 ma output. Decrease Output Filtering. Select this radio button to remove all output filtering on the 4-20 ma output. Invert Relays. To invert the relay settings from normally open to normally closed, select this radio button. Do not Invert Failsafe. If you invert the relays but do NOT wish to invert the failsafe setting, select this radio button. Advanced Settings