LMK 387. Stainless Steel Probe DRUCK & TEMPERATUR LEITENBERGER GMBH. Ceramic Sensor

Similar documents
LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

DMP 331. Industrial Pressure Transmitter for Low Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

DMP 333. Industrial Pressure Transmitter For High Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

JUMO MIDAS Pressure transmitter

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Pressure transmitter for industrial applications Type MBS 4510

Pressure transducer DMU 01K Compact version

CTE8000 / CTU8000 Series

JUMO dtrans p20 DELTA

Pressure transducers. with flush connections. Pressure transducers. with SIL assessment. HydroFox for level measurement

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

SITRANS P measuring instruments for pressure

Pressure Transmitter JUMO dtrans p30 Type

Pressure transmitter for elevated media temperatures

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

SATRON VDt Differential Pressure Transmitter

CTE7000 / CTU7000 Series Miniature pressure transmitters

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Pressure transmitters for industrial applications Type MBS 4510

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Absolute pressure gauge with diaphragm

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Flush-mounted pressure and level transmitters - KERAMESS KS series 100/101 -

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

JUMO MIDAS S05 Pressure transmitter Type

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Pressure Transmitter JUMO dtrans p30 Type

SATRON VT Pressure Transmitter

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Differential pressure gauge Model , copper alloy Model , stainless steel version

Components and parts list 4 5. Data sheet sensor SJ 3,5-SN 5 6. Cable gland 6.1 Cable gland nickel-plated 6.2 Cable gland stainless steel

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Direct-acting 3/2 way plunger valve

Magnetic switch For bypass level indicators Model BGU

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

Temperature sensor TE2

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Flow switches Series AD/VH

Compact differential pressure switch Models DC, DCC

Pressure transmitter for marine applications MBS 33M

Pressure measurement. Process pressure VEGABAR 14 VEGABAR 17. Product Information

Pressure transmitter JUMO dtrans p02

2/2- and 3/2-way solenoid valve for aggressive fluids

Electronic flow switch With display, for liquid media Model FSD-3

Differential pressure transmitter PASCAL Ci4 Delta P

Mechatronic pressure measurement. Applications. Special features. Description

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

Differential pressure switch Model DPS40

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Submersible Pressure

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

ECT Applications. Features

Flush-mounted pressure and level transmitters - KERAMESS KS S 200/201 - Superior Precision

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Ex m Solenoid Operator Type 0519

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Differential pressure transmitter PASCAL Ci4 Delta P

Pressure Transmitters for Sanitary Applications Model SA-11

Pressure transmitter for industrial applications Type MBS 4500

Pressure transmitter COMPACT ECOnomic

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Surface thermocouple Model TC50

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Compact pressure switch Model PCS

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

SATRON VTe pressure transmitter

Compact temperature switch Model TCS

Transcription:

DRUCK & TEMPERATUR LEITENBERGER GMBH LMK 87 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... mh O up to 0... 00 mh O Output signals -wire: 4... 0 ma -wire: 0... 0 V others on request Special characteristics diameter mm diaphragm ceramics 96% Al O good long-term stability especially for waste water, Optional versions diaphragm ceramics 99,9% Al O IS-version Ex ia = intrinsically safe for gases and dust mounting with stainless steel tube different kinds of cable different kinds of elastomer The stainless steel probe LMK 87 was developed for level and gauge measurement in wastewater, sludge or water courses. The mechanical robustness of the front-flush ceramic diaphragm facilitates an easy disassembly and cleaning of the probe in case of service. Compared to the level probe LMK 8 the outside-diameter is only mm, which allows an easy installation and backfitting in tubes or in cramped fitting conditions. An IS-version is also available. Preferred areas of use Water Groundwater and level monitoring Sewage waste water treatment water recycling Fuel and oil Tank battery Biogas plants

LMK 87 Input pressure range Nominal pressure gauge [bar] 0, 0,6 0,5 0,4 0,6,6,5 4 6 0 Level [mh O],6,5 4 6 0 6 5 40 60 00 Overpressure [bar] 4 5 5 7 7 0 0 0 0 Berst pressure [bar] 4 6 8 8 9 9 8 5 5 0 0 Permissible vacuum [bar] -0. -0. -0.5 - Output signal / Supply Standard Option IS-version Option Performance Accuracy Permissible load -wire: 4... 0 ma / V S =... 6 V DC -wire: 4... 0 ma / V S = 4... 8 V DC -wire: 0 0 V / V S = 4... 6 V DC standard: ± 0.5 % FSO option: ± 0.5 % FSO others on request -wire: R max = [(V S V S min) / 0.0 A] Ω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability Turn-on time Mean response time ± 0. % FSO / year 450 msec 70 msec Measuring rate 80 Hz accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Tolerance band [% FSO].0% FSO in compensated range -0... 80 C Permissible temperatures Permissible temperatures medium: -40... 85 C electronics / environment: -40... 85 C storage: -40... 85 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 additional external overvoltage protection unit in terminal box KL or KL with atmospheric pressure reference available on request Electrical connection Cable outlet shielded cable with integrated air tube for atmospheric reference (for nominal pressure ranges absolute, the air tube is closed) Materials (media wetted) Housing standard: stainless steel.4404 (6 L) others on request Cable PVC (-5 70 C) gray PUR (-5 70 C) black FEP (-5 70 C) black TPE (-5 5 C) blue others on request Seals (O-rings) standard: FKM option: EPDM; FFKM (min. permissible temperature from -5 C) others on request Diaphragm standard: ceramics Al O 96% option: ceramics Al O 99,9% Protection cap POM do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expected IS-protection Approval DX4B-LMK 87 IBExU 5 ATEX 066 X zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex ia IIIC T5 C Da Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i = 49, nf; L i = 0 µh; the supply connections have an inner capacity of max. 00 nf opposite the enclosure Permissible temperatures for in zone 0: -0... 60 C with p atm 0.8 bar up to. bar environment zone and higher: -5... 65 C Connecting cables cable capacity: signal line/shield as well as signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield as well as signal line/signal line: µh/m Miscellaneous Current consumption max. ma Weight approx. 80 g (without cable) Ingress protection IP 68 CE-conformity EMC Directive: 04/0/EU Pin configuration Electrical connection cable colours (IEC 60575) signal + (only -wire) wh (white) bn (brown) gn (green) Shield gnye (green-yellow)

LMK 87 Wiring diagrams -wire-system (current) -wire-system (voltage) p A VS p VS I U V Dimensions (in mm) standard option: screw-in version with protection cap without protection cap with thread R/ for mounting with stainless steel tube G/4 G/ open

06 DRUCK & TEMPERATUR Leitenberger GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. LMK 87 Mounting flange with cable gland Suitable for all probes Flange material Stainless steel.4404 (6 L) Material of cable gland standard: brass, nickel plated on request: stainless steel.405 (0); plastic Seal insert material: TPE (ingress protection IP 68) Hole pattern according to DIN 507 Version Size (in mm) Weight DN5 / PN40 D = 5, k = 85, b = 8, n = 4, d= 4.4 kg DN50 / PN40 D = 65, k = 5, b = 0, n = 4, d= 8. kg DN80 / PN6 D = 00, k = 60, b = 0, n = 8, d= 8 4.8 kg Ordering type Ordering code DN5 / PN40 with cable gland brass, nickel plated ZMF540 DN50 / PN40 with cable gland brass, nickel plated DN80 / PN6 with cable gland brass, nickel plated Terminal clamp Suitable for all probes with cable 5.5... 0.5 mm Werkstoff standard: steel, zinc plated optionally: stainless steel.40 (04) Weight approx. 60 g Ordering type Terminal clamp, steel, zinc plated Terminal clamp, stainless steel.40 (04) ZMF5040 ZMF806 Ordering code Z0058 Z0057 cable gland M6x.5 with seal insert (for cable- 4... mm)

LMK 87 DRUCK & TEMPERATUR LEITENBERGER GMBH LMK 87 - - - - - - - - - - Spezifikationsblatt / specification sheet Messgröße Pressure relativ in bar absolut in bar gauge in bar absolute in bar 6 0 6 auf Anfrage consult relativ in mh O gauge in mh O 6 Eingang [mh O] [bar] Input [mh O] [bar],0 0,0 0. 0 0 0,6 0,6.6 0.6 6 0 0,5 0,5.5 0.5 5 0 0 4,0 0,40 4.0 0.40 4 0 0 0 6,0 0,60 6.0 0.60 6 0 0 0 0,0 0.0 0 0 6,6 6.6 6 0 5,5 5.5 5 0 40 4,0 40 4.0 4 0 0 60 6,0 60 6.0 6 0 0 00 0 00 0 0 0 Sondermessbereiche 9 9 9 Gehäuse Housing Edelstahl.4404 (6L) Stainless steel.4404 (6L) Bauform Design Tauchsonde Einschraubsonde mit G/" offen Einschraubsonde mit G/4" frontbündig probe screw-in version G/" open screw-in version G/4" flush A B Trennmembrane Diaphragm Keramik Al O 96% Keramik Al O 99,9% Ceramics Al O 96% Ceramics Al O 99.9% C Ausgang Output 4 0 ma / -Leiter 0 0 V / -Leiter Ex-Schutz 4 0 ma / -Leiter 4 0 ma / -wire 0 0 V / -wire Intrinsic safety 4 0 ma / -wire E Dichtung Seals FKM EPDM FKM EPDM FFKM FFKM 7 auf Anfrage consult Elektrischer Anschluss Electrical connection PVC-Kabel PUR-Kabel PVC-cable PUR-cable FEP-Kabel FEP-cable TPE-Kabel TPE-cable 4 Genauigkeit Accuracy Standard 0,5 % FSO standard 0.5 % FSO Option 0,5 % FSO option 0.5 % FSO Kabellänge Cable length in m in m 9 9 9 Sonderausführungen Special version Standard vorbereitet für Montage mit Edelstahlrohr standard prepared for mounting with st. steel pipe 0 0 0 5 0 9 9 Preise EXW Thierstein, ausschl. VerpackunPrices EXW Thierstein, excluding package min. Temperatureinsatzbereich ab -5 C min. permissible temperature from -5 C Kabel mit eingearbeitetem Luftschlauch als Referenzbezu cable with integrated air tube for atmospheric pressure reference Edelstahlrohr gehört nicht zur Lieferung stainless steel pipe is not part of the supply DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D-78 Kirchentellinsfurt GERMANY Tel. +49 (0) 7-9090-0 Fax +49 (0) 7-9090-99 E-Mail: DT-Info@Leitenberger.de www.druck-temperatur.de