AutoDose Automatic Dispensing System

Similar documents
UltraDose From Lyn Distributing

THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS

DEMA 257C / 257CV PRO BATTERY DRAIN CHIEF INSTALLATION & OPERATING INSTRUCTIONS

ICS Integrated Cleaning System. Rechargeable Battery

Alpha Tech Pet, Inc. HydroMAID - "Mobile Automated Integrated Diluter" Rechargeable Battery

Compact Cleaning System

RH800 & 2000 MAINTENANCE GUIDE

Air Conditioner for M915 A0/A1 Truck

ECLIPSE Laundry Dispenser Controller

DEMA 259B DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Tools Needed for Mounting Cleá Filling Station

DR-2000 Customer Benefits

MITYFLEX PERISTALTIC PUMPS

BIOACTIVE SOLUTIONS AC DRAIN STATION

M-3025CB-AV Fuel Pump

Flexible Solutions HS115 Automatic Metering System Owner's Manual

Items # and #

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

Alliance Towel Dispensing System. Operation Manual

Pivotell Advance Automatic Pill Dispenser Instructions

Technical Manual. Table of Contents

These instructions were written for a MkVI VW GTI, but other models (Audi A3, VW Beetle, VW Jetta) are similar.

PowerFlo 20 Parts List/Assembly Instructions/Users Guide ***PLEASE READ ALL INSTRUCTIONS CAREFULLY AND THOROUGHLY***

M-1115S Series Fuel Pump

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

Marsh Shipping Supply Co. LLC. Marsh TD2100 Electric Taper Technical Manual

PowerFlo Parts List/Assembly Instructions/Users Guide ***PLEASE READ ALL INSTRUCTIONS CAREFULLY AND THOROUGHLY***

PowerFlo 50 Parts List/Assembly Instructions/Users Guide ***PLEASE READ ALL INSTRUCTIONS CAREFULLY AND THOROUGHLY***

(Airgap)

PERSONAL PLOW. Off-Truck Components. Installation Instructions

INSTALLATION INSTRUCTIONS

Operating and Installation Instructions

FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units

Self Cleaning Hood System Installation, Operation, and Maintenance Manual

Thank you for purchasing the Craven Speed FlexPod Complete Gauge Pod Kit For R56, R58, R59, R60 with Refresh Engines (2011+)

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

INSTALLATION INSTRUCTIONS

Agxcel GX12i Chemical Injection System

Trapper Drain Maintenance/Odor Control Chemical Dispensing

Single Nozzle Systems UNIVERSAL NOZZLE SYSTEM INSTRUCTIONS Part #'S 00-1XXXXX

UNITIZED batching INSTaLLaTION guide

BEFORE BEGINNING INSTALLATION

Use & Care Guide. If you have any problems or questions, visit us at For Commercial Use Only

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

DEMA SQUIRT DRAIN UNIT

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

π H-5806 TORK AUTOMATIC TOWEL DISPENSER PARTS THE KEY AND OPTIONAL PUSH BUTTON MODE uline.com USING PUSH BUTTON MODE USING THE KEY

E.R.I.C. Series Electronic Metering Pump Installation & Operation Manual (Enhanced Control) Manual No.: Revision : 00 Rev.

Maintenance Information

Volkswagen New Beetle Body - Exterior 64 Glass, Window regulators (Page GR-64)

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Installation For Service Only

IMPORTANT SAFETY INSTRUCTIONS

Thank you for purchasing the Craven Speed FlexPod Complete Gauge Pod Kit

Service Manual Air Plus Second Stage

Signet 2517 Brass Paddlewheel Flow Sensor * *

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

Fuel Injection System

Dilution Control Systems. 2-Button Station Model OPERATION SERVICE PARTS CARE

General Operation. To set Time of Day. To set Time of Regeneration / Backwash

350/370Z System Instructions Part #

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

LM-200 MECHANICAL LUBE METER Owner s Manual

ON DEMAND MAINTENANCE GUIDE

Instruction Book for. ContouR ElECtRol

ADVANTAGE Annual Preventive Maintenance Instructions

Installation Instructions

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

Installation Manual for Philips Intellivue MP5/20/30 VHM-25 Channel Mount Kit

IMPORTANT INFORMATION

HG 20F-012E-01 OIL CONTROL GUN

Models 8100PP & 86110LP. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

665 Series Dispenser. Metering tip kit

AOYUE INT. Advanced Repairing System NT 701A++ INSTRUCTION MANUAL

Fleck 2510 Manual Sediment Filter Installation & Start-Up Guide

INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT

Pro 30 Gas Caddy. Model FC-P30-UL Operator s Manual. JohnDow Industries, Inc. 151 Snyder Ave. Barberton, OH 44203

FOR New Electric Kit and Remote Control Installation

INSTALLATION INSTRUCTIONS

Pro 30 Plus Gas Caddy

Installation Instructions

WS2H/ WS3 Error Codes

ON DEMAND INSTALLATION GUIDE

SERVICE MANUAL L130B / L4130 Series Logstacker Drive Axle With Bolt-On Stub End Retainer

KIT CONTENTS. Multimeter or test light Wire crimpers or soldering equipment. Wire terminals & connectors 10A inline fuse

Signature Series. Duplex Softener Service Manual

Perfmaster Air V3. Serial Number. Date

SERVICING INSTRUCTIONS

Warning! General Maintenance 4-11

Breezair TBA 550 Installation Manual

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

Installation Instructions

USER'S MANUAL QUESTIONS? TABLE OF CONTENTS CAUTION. Model No. GGSY49230 Serial No. Serial Number Decal (Under Seat)

DRIVE SHAFT LOCATION INDEX

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

Mudhen Portable Slurry System Owners Manual

Installation Manual for VHM-25 Series Arms Channel Mount

Transcription:

AutoDose Automatic Dispensing System The AutoDose TM is a battery or A/C-powered peristaltic pumping dispenser that runs automatically at preset times as programmed with an electronic timer / control. Product operates reliably and consistantly, even in demanding environments. This guide contains instructions for installing, programming, and troubleshooting the AutoDose Dispensing System. Throughout the guide, the following icons are used to indicate the model(s) to which each step pertains. Models: Mounts: Power: Pail Mount (3.5 5 gal pail) 8 D-cell batteries Wall Mount 8 D-cell batteries This package should contain: AutoDose Dispenser Specifications: PUMP Flow Rate Tube Material Inlet Vacuum Outlet Pressure One AutoDose TM dispenser INSTALL PACKAGE CONTAINING: Approx 3.5 oz / min EPDM 20 in Hg 20 psi Wall Mount A/C Power or 8 D-cell batteries Ceramic weight and strainer for inlet tubing Polyethylene tubing (10 ft) Cable ties Mounting Bracket (Some Models) AC Adapter (Some Models) Injection Fitting SYSTEM CABINET Material Polypropylene and ABS Size (Model 1170) Approx. 7 3/4 tall X 14 diameter (does not include container 1170 model system sits on) Size (Models 1180 and 1190) 4 3/4 X 6 3/4 X 8 1/3 PROGRAMMABLE TIMER / CONTROL Program Duration Daily / Weekend / Week Days/Special Maximum # of Events 24 Dispense Amount per Event.5 oz 30 oz (dispensed in.5 oz increments) or 15 900 ml (dispensed in 15 ml increments)! Please use this equipment carefully and observe all warnings and cautions. ALWAYS observe safety and handling instructions of the chemical manufacturers. ALWAYS direct discharge away from you or other persons or into approved containers. ALWAYS dispense cleaners and chemicals in accordance with manufacturer s instructions. Exercise CAUTION when maintaining your equipment. KEEP equipment clean for proper operation. WEAR protective clothing and eyewear when working in the vicinity of all chemicals, fi lling or emptying equipment, or changing tubes. ALWAYS re-assemble equipment according to instruction procedures. Be sure all components are fi rmly screwed or latched into position. Ensure that hoses and electrical wires are properly placed and not kinked or pinched. ONLY USE ALKALINE BATTERIES. Tube life will vary depending on the type of treatment product used. To prevent emergency service, schedule replacement at least once per year. NOTE: The batteries should be scheduled for periodic replacement. Using a total of 40 running (pumping) hours, create a schedule for servicing the unit and changing the batteries. Maintaining the power source as such will help to provide the proper dosing by providing a more consistent pumping rate. 10094778 Rev F 1/15 Hydro Systems Company, Inc. 2015 www.hydrosystemsco.com Toll Free: 1.800.543.7184 1

Installation STEP 1A : Install the Batteries a. Loosen the battery door screw. b. Open the battery compartment. c. Place eight, fresh alkaline D-cell batteries into the holder as shown in the battery compartment and in the diagram on right. Battery life is typically 40 running hours. A low battery indicator will alert you to a low voltage condition indicating battery change. Program settings will be maintained if dispenser is disconnected from power source. Upper Level Placement Lower Level Placement After installing batteries correctly you will see Batt OK diplayed on the unit. Batt OK If a problem with the battery placement is detected Batt Err will be displayed on the unit Batt Err and the red LED for Low Battery will be fl ashing or a blank screen. Correct battery placement using the diagram shown above. STEP 1B : Mount the Dispenser For Models 1180 and 1190, you ll need to mount the dispenser before attaching the power cord (if supplied). a. Choose a location near the pipe or grease trap into which it will be dosing. In kitchens, the unit may be mounted beneath the dish machine work tables or on the wall. b. Use the mounting bracket to mark the appropriate locations for the mounting hardware. c. Drill the holes accordingly and insert the anchors (if necessary) and screws provided. d. Affi x the mounting bracket to the wall. e. Mount the dispenser onto the mounting bracket. f. Secure the dispenser with the remaining screw provided. 10094778 Rev F 1/15 Hydro Systems Company, Inc. 2015 www.hydrosystemsco.com Toll Free: 1.800.543.7184 2

Installation STEP 1C : Install the Power Cord (if included) For certain models, either batteries or a 12v DC adapter may be used. For the model 1190, use only the adapter specifi ed from the manufacturer to ensure proper operation. NOTE: Usage of AC adapter must conform to local laws and codes. a. Locate the jack on the side of the unit. b. Install the adapter plug into the jack. c. Plug the adapter into the wall receptacle. CAUTION/CUIDADO: Wires left hanging loose may be a tripping hazard, or may accidentally cause the adapter to become unplugged. STEP 2 : Determine Appropriate Dispenser Location For Model 1170, choose a location away from traffi c. Bumping the dispenser may knock it over if the pail is almost empty. For Models 1180 and 1190, please refer to step 1B on page 2 for guidelines on determining the appropriate dispenser location. 10094778 Rev F 1/15 Hydro Systems Company, Inc. 2015 www.hydrosystemsco.com Toll Free: 1.800.543.7184 3

Installation STEP 4 : Install the Inlet and Discharge Tubing a. From the tubing supplied, cut a section long enough to reach from the pump inlet (left side port) to the bottom of the pail to be used. Slide the ceramic weight onto the end and insert the strainer into the end of the tube. b. Route the tube properly and insert into the inlet compression fi tting. c. Hand tighten the nut to secure. d. Connect remaining tubing to the exit side port and tighten. e. Route and secure the tubing with cable ties provided so that the product is dispensed directly into the intended drain to be treated. f. If connecting to an existing facility drain piping, drill and tap the drain pipe or trap cover for the 1/8 NPT injection fi tting supplied. When the product should be dispensed into a trap, but the trap is inaccessible, feed the tubing down the inlet pipe to the trap. In these cases, the fi tting can be drilled through to allow the tubing to pass into the pipe. Wrap the injection fi tting once with sealing tape or thread compound and screw in the injection fi tting. Tighten to provide a positive seal. NOTE: Be sure the tubing will be out of the way of traffi c and will not impede motion required in the area. Creating a low place in the run of tubing near the fi tting will minimize drainage from the tubing. STEP 5 : Prepare/Prime the Dispenser for Use a. Open the container of treatment product. b. Drop the strainer end of the inlet tube into the container. c. Place the dispenser on the container (for Model 1170). d. Prime the pump: Press ENTER to wake the display and push and hold the Prime button until product is evident at exit to drain. e. Review the program and adjust if necessary. 10094778 Rev F 1/15 Hydro Systems Company, Inc. 2015 www.hydrosystemsco.com Toll Free: 1.800.543.7184 4

User Interface Definition LCD Display Use ENTER to view or change the data for that option. ENTER is also used to save data. Use BACK to view previous menu. The LOW BATTERY indicator will illuminate when battery life is low. Use the PRIME button to prime the pump. The user can view and program settings on the device. Use FORWARD/BACKWARD to increase or decrease options in each menu setting. NOTE: To conserve power, the display will not be visible during normal operation. Reviewing Set Program Press ENTER. Press PROGRAM. Press ENTER to step through settings. 10094778 Rev F 1/15 Hydro Systems Company, Inc. 2015 www.hydrosystemsco.com Toll Free: 1.800.543.7184 5

Unlocking Device Press ENTER to wake controller. Press PROGRAM and hold for 2 seconds. Press ENTER twice and enter PIN, using using to change each number, then press ENTER to move to the next number. NOTE: The default password is 1000. You will have an opportunity to customize the pin in a later step. After the 4th number has been entered, press ENTER, and the system will validate the number. If the number is correct, the user will enter Program Mode. If incorrect, INVALID will appear on the display and the unit will exit programming mode. ENTER USER PIN _ 1000 INVALID When entering programming mode, the Low Batt LED will fl ash rapidly to signify that the device is momentarily inactive during programming. Setting Time/Day Press ENTER to set hours. TIME/DAY Press ENTER and set hours. Use Press ENTER to set minutes. Use Press ENTER to save and continue with day. Use to adjust the day. Press BACK to edit hours if needed. to adjust hours. to adjust minutes. 12:00 12:00 SUN 10094778 Rev F 1/15 Hydro Systems Company, Inc. 2015 www.hydrosystemsco.com Toll Free: 1.800.543.7184 6

Program Dispense Units Press ENTER to begin setting the dispense units. DISPENSE UNITS Select OZ or ML. The dispense amount applies to the amount of chemical dispensed each time the Drain Treater is scheduled to run. Program dispense amount. Use to adjust the amount in.5 oz. steps (units can be changed to ml in a different menu). OZ DISPENSE AMOUNT ML Program Dispense Days.5 _ OZ Press ENTER to begin setting the dispense Dispense Days. Use to pick a preset number of days, or choose SPECIAL to program each day individually. DAILY applies to every day of the week. WEEKDAYS applies to Mon-Fri. WEEKENDS applies to Sat-Sun. SPECIAL applies to a unique set of days during the week. Press ENTER to save and go to the next menu option. DISPENSE DAYS DAILY WEEKDAYS WEEKENDS Note: When using SPECIAL to select a particular day to program, deselect the days not desired using ENTER to navigte Sunday through Saturday. SPECIAL SUN Y? _ SAT Y? _ 10094778 Rev F 1/15 Hydro Systems Company, Inc. 2015 www.hydrosystemsco.com Toll Free: 1.800.543.7184 7

Program Dispense Times Press ENTER to begin setting the Dispense Times. Event 1 (up to 24 total) will automatically be selected. If acceptable, press ENTER to accept and move to event 2. Press ENTER to begin with setting the hours. Use to adjust the number up and down. The AM/PM function will automatically change. Press ENTER to save and continue with minutes. Minutes will be in increments of 10 minutes. Continue programming events as needed remembering each event will dispense the amount selected earlier. When fi nished, press PROGRAM when next event is displayed. Press ENTER at Done NOTE: To eliminate an event, reprogram desired events, then when EVENT N is visible, exit by pressing PROGRAM, and then ENTER to exit programming as normal. Review programming and EVENT N to EVENT 24 will show NONE. DISPENSE TIMES EVENT 1 12:00 am 12:15 am STORED EVENT N DONE Program User PIN Press ENTER to begin entering PIN. Use to change each number, then press ENTER to move to the next number. After the 4th number, press ENTER to save and complete programming. The time of day should be displayed. NOTE: Controller will go to sleep after 30 seconds and display will be blank until awakened by pressing ENTER. USER PIN NEW PIN N_ ENTER PIN _ 0000 Y 10094778 Rev F 1/15 Hydro Systems Company, Inc. 2015 www.hydrosystemsco.com Toll Free: 1.800.543.7184 8

Maintenence: Changing the Pump Tubing NOTE: You may want to work over old newspapers or other discardable material to protect fl oors or other areas from the possibility of spilled treatments. Remove the Old Tubing a. Loosen and remove tubing from compression fi ttings. b. Loosen screw on pump cover and remove. c. Lay aside the supply and discharge tubing. d. Remove the old squeeze tube assembly from pump housing and discard it. NOTE: If drain treatment leaks on pump housing, it can be washed in soapy water. If the rotor assembly has been wetted, wipe it with a dry cloth. It is not necessary to wipe the grease from the pump housing if the grease is clean. Inspect the Pump a. While the pump is disassembled, inspect all parts for foreign matter. b. Clean the parts as necessary. c. Check the rollers to ensure they turn freely. d. Inspect the rotor. CAUTION/CUIDADO: If the rotor needs service, replace the entire rotor. Install the New Tubing a. Replace the rotor and put a small amount of tube lubricant on each end of the rotor assembly shaft (bearings). b. Position the pump inlet port as shown. c. Bend the new tube in half and insert without twisting the tube and place the outlet port fi tting in as shown. d. Replace the rotor over the motor (blade) shaft and use a screwdriver to twist the rotor as it is inserted. e. Replace cover and tighten screw. f. Reattach the inlet and exit port tubing. g. Prime the product to ensure the fi ttings are tight and unit is ready for operation. NOTE: A small amount of tube lubricant in each channel will make this process easier. CAUTION/CUIDADO: Be sure the tube is not twisted during installation. Twisting the tube will greatly reduce tube life. 10094778 Rev F 1/15 Hydro Systems Company, Inc. 2015 www.hydrosystemsco.com Toll Free: 1.800.543.7184 9

Troubleshooting ISSUE If the motor is turning: If the motor won t turn: Unit is not pumping fluid: Wake and push PRIME button. Check level of drain treatment supply. Check for air leaks in the supply tubing connection to pump tube. Check for clogs in inlet and outlet tubes. Ensure pump tube is not twisted. Check pump tube (as it wears out, the amount of fl uid pumped decreases); change if necessary. Are springs broken on rotor? Ensure programmer is functioning: Try to run pump manually (see Prime Function, page 4 Step 4). Check program: ensure times for dispense are correct. Check battery orientation. Check battery condition; install new batteries. Is Low Battery light illuminated? Replace tube binding rotor. Unit is pumping improperly: Check the programmed dispense amount and adjust as necessary. Ensure programmer is turning on and off at set times. Check for improper tube installation. Replace tubing with proper size. Replacement Parts Part Number Part Description Hydro Systems Company cares about your satisfaction. Please contact our customer service department for technical assistance. For all of your replacement parts and maintenance needs, contact your distributor. 5 3 4 2 1 1 15-06959-04 Pump Tube Assembly (EPDM) 2 41-05567-00 Compression Nuts 3 03-06281-02 Rotor Assembly 4 90090430 Pump Cover 5 27-08008-00 Thumb Screw 6 509100 Injection Fitting 7 609600 Strainer 8 509900 Weight 9 10094781 AC Adapter 10 10012301 Tubing 20 Ft. Roll 11 13-06647-00 Mounting Bracket Kit 12 (also available) 10095411 Pump Tube Assembly Viton 13 03-07708-04 Pump Tube Assembly Silicone 10094778 Rev F 1/15 Hydro Systems Company, Inc. 2015 www.hydrosystemsco.com Toll Free: 1.800.543.7184 10