The following are specific provisions of 1910(a)(2) that could be seen in the LBM sector

Similar documents
Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

ELECTRICAL - GENERAL REQUIREMENTS SELF INSPECTION CHECKLIST

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

NEC 2011 Code Changes

Spring Test 10 due 05/11/2013

Have You Been Grounded Lately

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Chapter 8 Interior Wiring and Lighting

CHAPTER 10 ELECTRICAL. Notes:

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

Chapter 5. Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI)

ELECTRIC VEHICLE CHARGING FOR BUILDINGS

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

Electrical Hazards in Construction

2011 NEC Code Updates Part 3

CHAPTER V RESIDENTIAL WIRING

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

ELECTRICAL. 60 Minutes

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Chapter 14:08 Factories and Works (Electrical) Regulations, Chapter 14:08 Factories and Works (Electrical) Regulations, 1976

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

FACT SHEET Standard: Electrical Safety

Spring Test 7 due 05/03/2013

Table of Contents. Unit 3 Magnetism Unit 1 Matter Unit 4 Electricity Unit 2 Electron Theory Unit 5 Electromagnetism...

CAL/OSHA ELECTRICAL LOW VOLTAGE

Bulletin Wiring methods for Solar Photovoltaic Systems Rule and , Tables 11 and 19

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

TRANSMISSION SYSTEMS

Preface...x Chapter 1 Electrical Fundamentals

Generator Fire Safety: Generator assemblies should be located outside the building.

Fee $20 Course: NEC Changes 1 This course is valid for these credentials: Credential Description Cred Code Credit Hours

Definitions of and have been revised. a. automatic b. nonautomatic c. none of the above d. both a and b

TABLE OF CONTENTS. About the Mike Holt Enterprises Team... xviii CHAPTER 1 ELECTRICAL THEORY... 1

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

2014 NEC Changes (Homestudy)

Electrical Tech Note 111 Biosystems & Agricultural Engineering Department Michigan State University

SINGLE PHASE WIRING SPECIFICATIONS

THREE PHASE WIRING SPECIFICATIONS

9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

ARKANSAS ELECTRICIANS

Electrical Safety Program

90.2 Scope. The installation of electrical conductors, equipment and raceways for:

University of Vermont Physical Plant Department Burlington, Vermont

ROCKY MOUNTAIN CHAPTER IAEI MARCH 15-16, 2012

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

A Look at the 2017 NEC Significant Changes

Mecklenburg County Common Code Defects

Continued from Part 2 Rules

Bulletin Wiring methods for Solar Photovoltaic Systems Rules and , Tables 11 and 19

PUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013.

UNDERGROUND SERVICES - SECONDARY

NEC 2014 Code Changes

Second Revision No. 25-NFPA [ Section No ]

2011 NEC Significant Changes Part 1 The following course will summarize many of the important changes to the NEC code.

In general this document presents specific safety procedures for systems with potentially lethal voltages on bare or exposed conductors.

See Part 3 for the Introduction for Article 314

CONTINUING EDUCATION FOR OREGON ELECTRICIANS NEC Code Change Part 1 8 Hours

ELECTRICAL SAFETY-RELATED WORK PRACTICES

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

CHAPTER 10 ELECTRICAL

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

Design Standards NEMA

Bulletin Wiring methods for Solar Photovoltaic Systems Rules, 2-034, , and , Tables 11 and 19

120-ELECTRICAL SAFETY PROGRAM

2011 NEC Changes Part 2 (Homestudy) (Homestudy)

Specific Purpose Equipment and Installations -- OSHA Standard

SURFACE TRACK (120/250V) SPECIFICATIONS

WISCONSIN ELECTRICIANS

CONTINUING EDUCATION FOR OREGON ELECTRICIANS NEC Code Change Part 2 Course # Hours

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code

Overcurrent Protection (2014 NEC) (Homestudy)

TABLE OF CONTENTS CHAPTER 1 ELECTRICAL THEORY About This Textbook...xi. Passing Your Exam...xiv. How to Use the National Electrical Code...

COMMERCIAL QUICK REFERENCE

Energized Electrical Work

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

Pretest Module 24 Three-phase Service Entrance

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

2016 Photovoltaic Solar System Plan Review List

Bulletin Wiring methods for solar photovoltaic systems Rules 2-034, , , , , Tables 11 and 19

PART A General Conductor Requirements

SOME REVIEW - QUESTIONS 2011 NATIONAL ELECTRICAL CODE

Unqualified persons: People with little or no such training related to electrical equipment and safety.

2014 NEC Changes Part 4

Installing a Downstream Distribution Panelboard

Surface Regulations and Policies

SECTION PANELBOARDS

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

Contents. Obtaining Electric Service from Your Cooperative...1. Bonding Frames of Major Appliances...4. Voltage Drop...8. Drawings...

Chapter 1 Electrical Theory...1

Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast

Section 02: Pre-Installation Procedures

Plastic Ceiling Receptacle Lampholders

PRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)

2014 NEC Changes Part 1 (Homestudy)

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

ME 463 Electronics Design

Transcription:

Know the Rules on Temporary Wiring OSHA Standard 1910.305, Wiring methods, components, and equipment for general use, addresses wiring methods, components, and equipment for general use as one of several parts of 1910 Subpart S, Electrical. The Standard is organized around 1910.305(a), Wiring methods, 1910.305(b), Cabinets, boxes, and fittings, 1910.305(c), Switches, 1910.305(d), Switchboards and panelboards, 1910.305(e), Enclosures for damp and wet locations, 1910.305(f), Conductors for general wiring, 1910.305(g), Flexible cords and cables, 1910.305(h), Portable cables over 600 volts, nominal, 1910.305(i), Fixture wires, and 1910.305(j), Equipment for general use. Of the requirements specified in 1910.305(a), Wiring methods, the LBM sector has been cited on the provisions that address temporary wiring in 1910(a)(2). Examples of temporary wiring usually include the use of extension cords, and can also involve the use of temporary branch circuits and electrical boxes in ways they are not intended to be used. In general, temporary wiring may be used in only four specific situations: during remodeling, maintenance, or repair; for decorative purposes during holidays or other events, but for no more than 90 days; for experimental or development work; or for and during emergencies. The following are specific provisions of 1910(a)(2) that could be seen in the LBM sector 1. Temporary electrical power and lighting installations of 600 volts, nominal, or less may be used only as follows [1910.305(a)(2)(i)]: During and for remodeling, maintenance, or repair of buildings, structures, or equipment, and similar activities For a period not to exceed 90 days for Christmas decorative lighting, carnivals, and similar purposes For experimental or development work, and during emergencies 2. Temporary wiring must be removed immediately upon completion of the project or purpose for which the wiring was installed. [1910.305(a)(2)(ii)] 3. Temporary electrical installations of more than 600 volts may be used only during periods of tests, experiments, emergencies, or construction-like activities. [1910.305(a)(2)(iii)] 4. The following requirements apply to feeders i [1910.305(a)(2)(iv)]: Feeders must originate in an approved distribution center. 1

Conductors ii may only be run as multiconductor cord or cable iii assemblies. (If installed as permitted in paragraph (a)(2)(i)(c) of this section, and if accessible only to qualified persons, feeders may be run as single insulated conductors.) 5. The following requirements apply to branch circuits iv [1910.305(a)(2)(v)]: Branch circuits must originate in an approved power outlet v or panelboard vi. Conductors must be multiconductor cord or cable assemblies or open conductors. If run as open conductors, they must be fastened at ceiling height every 3.05 m (10.0 ft). No branch-circuit conductor may be laid on the floor. If run as open conductors, each branch circuit that supplies receptacles or fixed equipment must contain a separate equipment grounding conductor. vii 6. Receptacles viii shall be of the grounding type. Unless installed in a continuous grounded metallic raceway ix or metallic covered cable, each branch circuit must contain a separate equipment grounding conductor and all receptacles must be electrically connected to the grounding conductor. [1910.305(a)(2)(vi)] 7. Bare conductors or earth returns may not be used for the wiring of any temporary circuit. [1910.305(a)(2)(vii)] 8. Suitable disconnecting switches x or plug connectors xi must be installed to permit the disconnection of all ungrounded conductors of each temporary circuit. Multiwire branch circuits xii must be provided with a means to disconnect simultaneously all ungrounded conductors at the power outlet or panelboard where the branch circuit originated. [1910.305(a)(2)(viii)] Note to paragraph (a)(2)(viii) of this section. Circuit breakers with their handles connected by approved handle ties are considered a single disconnecting means for the purpose of this requirement. 9. All lamps for general illumination must be protected from accidental contact or breakage by a suitable fixture or lampholder with a guard xiii. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded. [1910.305(a)(2)(ix)] 10. Flexible cords and cables must be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points. [1910.305(a)(2)(x)] 11. Cable assemblies and flexible cords and cables must be supported in place at intervals that ensure that they will be protected from physical damage. Support must be in the form of staples, cables ties, straps, or similar type fittings installed so as not to cause damage. [1910.305(a)(2)(xi)] 2

i Feeder: A circuit, such as conductors in conduit or a busway run, which carries a large block of power from the service equipment to a sub-feeder panel or a branch circuit panel or to some point at which the block power is broken into smaller circuits; or all circuit conductors between the service equipment, the source of a separate derived system, or other power supply source and the final branch-circuit overcurrent device. ii Conductor: A wire or combination of wires not insulated from one another, suitable for carrying electric current; or: (1) Bare. A conductor having no covering or electrical insulation whatsoever; (2) Covered. A conductor encased within material of composition or thickness that is not recognized by this subpart as electrical insulation; (3) Insulated. A conductor encased within material of composition and thickness that is recognized by this subpart as electrical insulation. iii Cable: A conductor with insulation, or a stranded conductor with or without insulation and other coverings (single-conductor cable); or: A combination of conductors insulated from one another (multiple-conductor cable). iv Circuit: A conductor or system of conductors through which an electric current is intended to flow. v Outlet. A point on the wiring system at which current is taken to supply utilization equipment. vi Panelboard. A single panel or group of panel units designed for assembly in the form of a single panel; including buses, automatic overcurrent devices, and with or without switches for the control of light, heat, or power circuits; designed to be placed in a cabinet or cutout box placed in or against a wall or partition and accessible only from the front. (See Switchboard: A large single panel, frame, or assembly of panels on which are mounted, on the face or back, or both, switches, overcurrent and other protective devices, buses, and (usually) instruments. Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.) 3

vii Grounding Conductor: A conductor used to connect metal equipment enclosures and/or the system grounded conductor to a grounding electrode, such as the ground wire run to the water pipe at a service; also may be a bare or insulated conductor used to ground motor frames, panel boxes, and other metal equipment enclosures used throughout electrical systems. In most conduit systems, the conduit is used as the ground conductor; or: A conductor used to connect equipment or the grounded circuit of a wiring system to a grounding electrode or electrodes. viii Receptacle. A receptacle is a contact device installed at the outlet for the connection of an attachment plug. A single receptacle is a single contact device with no other contact device on the same yoke. A multiple receptacle is two or more contact devices on the same yoke. ix Raceway. An enclosed channel of metal or nonmetallic materials designed expressly for holding wires, cables, or busbars, with additional functions as permitted in this standard. Raceways include, but are not limited to, rigid metal conduit, rigid nonmetallic conduit, intermediate metal conduit, liquidtight flexible conduit, flexible metallic tubing, flexible metal conduit, electrical metallic tubing, electrical nonmetallic tubing, underfloor raceways, cellular concrete floor raceways, cellular metal floor raceways, surface raceways, wireways, and busways. x Disconnecting (or Isolating) switch. (Over 600 volts, nominal.) A mechanical switching device used for isolating a circuit or equipment from a source of power. xi Connector: A device providing electrical connection/disconnections. It consists of a mating plug and receptacle. Various types of connectors include DIP, card edge, two-piece, hermaphroditic and wirewrapping configurations. Multiple contact connectors join two or more conductors with others in one mechanical assembly. xii Multiwire branch circuit: 4

xiii Guarded: Covered, fenced, enclosed, or otherwise protected, by means of suitable covers or casings, barrier rails or screens, mats, or platforms, designed to minimize the possibility, under normal conditions, of approach or accidental contact by persons or objects. Note: Wires which are insulated, but not otherwise protected, are not considered as guarded; or Covered, shielded, fenced, enclosed, or otherwise protected by means of suitable covers, casings, barriers, rails, screens, mats, or platforms to remove the likelihood of approach to a point of danger or contact by persons or objects. 5