S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

Similar documents
S1024-2POS / S POS S2024-2POS / S POS

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL

MVN Rotary Valve Actuators FOR CONTROL BALL VALVES VBG (DN15 TO DN32)

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

ML6420A/ML6425A,B. Electric Linear Valve Actuators

MS4120F, MS4620F, MS8120F, S2024-F, S20230-F Fast-Acting, Two-Position Actuators

MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators

V5049A FLANGED LINEAR VALVE PN25/40

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Excel 10 W7751H3007 VAV ACTUATOR

ML7420A/ML7425A,B. Honeywell. Electric Linear Valve Actuator FEATURES SPECIFICATIONS GENERAL SPECIFICATION DATA

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

MF4E MF4E

Actuators for Fire Protection Dampers

Commercial Actuator Selection Chart Non-Spring Return

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) ES142 Spring Return Electronic Actuators

V5422L / V5422E ACTUATED BUTTERFLY VALVES. FEATURES With factory-mounted electric actuator

Actuators for Fire and Smoke Protection Dampers

Non-Spring Return EconoDrive Floating Actuator

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

MF /MS Series

Technical Instructions Document No P25 EA GMA January 19, OpenAir. GMA Series Spring Return Rotary Electronic Damper Actuators

ComfortPoint Programmable Lon, VAV/Unitary Controllers

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

V5825B. Small Linear Valve / PN25 DH Compact Valve. FEATURES Pressure-balanced k vs m 3 /hr Normally-closed valve

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Actuators for Fire and Smoke Protection Dampers

Technical Instructions Document No P25 EA GMA May 19, OpenAir. GMA Series, Spring Return, 62 lb-in, Rotary, Electronic Damper Actuators

V5422L / V5422E ACTUATED BUTTERFLY VALVES. FEATURES With factory-mounted electric actuator. SPECIFICATIONS Valves

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)

OpenAir GCA Series Spring Return 142 lb-in Electronic Damper Actuators

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

LF Series Spring Return Direct Coupled Actuator

ESBE Series 60 Electronic Motor Actuator (Combined with ESBE 3&4-way rotary valves)

M9210-xxx-3 Electric Spring Return Actuators

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Master/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

V5422L / V5422E ACTUATED BUTTERFLY VALVES. SPECIFICATIONS Valves

V5422L / V5422E ACTUATED BUTTERFLY VALVES. SPECIFICATIONS Valves

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

MF Series MS Series

M9208-xxx-x Series Electric Spring Return Actuators

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

M9216 Series Electric Spring Return Actuators

Actuators for Fire and Smoke Protection Dampers

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

SmartX MF and MS

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

VRN Dynamic Pressure-Regulating Control Valves and Actuators

TAC DuraDrive Product Guide Direct Coupled Actuators

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Spyder BACnet Programmable Controllers

OpenAir. Technical Instructions. GCA Series Spring Return 160 lb-in Electronic Damper Actuators. Document No P25 EA GCA-1.

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

Product Cross Reference

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

M9208-xxx-x Series Electric Spring Return Actuators

M4410C/L SMALL LINEAR THERMOELECTRIC ACTUATORS

M9220-xxx-3 Electric Spring Return Actuators

M9203-xxx-2(Z) Series Electric Spring Return Actuators

DC-132 Non Spring Return Electronic Actuator Series

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Powers TM Controls EA 338 Electronic Actuator

M9220-xxx-3 Electric Spring Return Actuators

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

MT4-024/MT4-230 MT8-024/MT8-230

M100F Incremental Motor Actuator R81F Interface Board

M9208-xxx-x Series Electric Spring Return Actuators

MC-351, 421, 431, MC-4311

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

M9220 Series Electric Spring-Return Actuators

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

VA9208-xxx-xx Series Electric Spring Return Actuators

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

MA/F/S 4D-xxxx-xxx Two Position, Floating and Proportional Series SmartX Actuators Rotary Overshaft Actuators

M9109 Series Electric Non-spring Return Actuators

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

Transcription:

S000 / S000 SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR MODULATING AND FLOATING CONTROL GENERAL These direct-coupled damper actuators provide modulating / floating control for: air dampers, VAV units, air handlers, ventilation flaps, louvers, and reliable control for air damper applications with up to. m / 6 sq.ft (0 Nm / 88 lb-in) or.6 m / 0 sq.ft. (0 Nm / 77 lb-in) (seal-less dampers; air frictiondependent). FEATURES Self-centering shaft adapter Removable access cover Mechanical end limits (non-adjustable) Rotation direction selectable by choice of mounting orientation Mountable in any orientation (IP only when mounted on a horizontal shaft with access cover below the shaft) Mechanical position indicator SPECIFICATIONS Supply voltage S000 / S000 PRODUCT DATA VAC 0% / VDC, 0/60 Hz Nominal voltage S000 / S000 VAC / VDC, 0/60 Hz All values stated hereinafter apply to operation under nominal voltage conditions. Power consumption Holding Driving S000 VA / W VA S000 VA / W 6 VA Ambient limits Ambient operating limits -0...+60 C Ambient storage limits -0...+70 C Relative humidity...9%, non-condensing Safety Protection standard IP Overvoltage category III Lifetime Full strokes 60000 Repositions. million Full stroke spring return 60000 Mounting Round damper shaft 0...7 mm Square damper shaft...9 mm Shaft length mm End switch (when included) Rating A (resistive) / A (induct.) Triggering points 7 / 8 Torque rating S000 0 Nm (88 lb-in) S000 0 Nm (77 lb-in) Runtime 90 sec (0 Hz) Spring return timing 0 sec (0 Hz) Rotation stroke 9 Dimensions see Fig. 8 on page 6 Weight. kg Noise rating Driving 0 db(a) Holding 0 db(a) (no audible noise) Spring return 0 db(a) U.S. Registered Trademark EN0B-06GE R08 Copyright 08 Honeywell Inc. All rights reserved

SmartAct S000, S000 PRODUCT DATA MODELS order number supply voltage end switches power consumption torque S000 -- S000-SW VAC / VA (driving) / VA (holding) 0 Nm (88 lb-in) S000 VDC -- S000-SW 6 VA (driving) / VA (holding) 0 Nm (77 lb-in) Product Identification System N = non-spring return S = spring return 0 = 0 Nm (88 lb-in) 0 = 0 Nm (77 lb-in) SmartAct S 0 0 X 00 = modulating + floating = V 0 = 0 V OPERATION / FUNCTIONS Contents of Package Self-centering shaft adapter Retainer clip Rotational angle scales (0...90 / 90...0 ) Mechanical end limits (non-adjustable) Hex wrench for manual adjustment 6 Rotation direction switch 7 Access cover Rotary Movement The actuators are designed to open a damper by driving the damper shaft in either a clockwise or counterclockwise direction. Fig.. Product Identification System CCW to close (failsafe position) CW to open 90 0 CW to close (failsafe position) 0 CCW to open 90 NOTE: Actuators are shipped in the fully-closed (spring return) position. Position Indication An arrow molded into the hub points to tick marks on the label to indicate the hub rotary position. Fig.. Mounting orientation EN0B-06GE R08

SmartAct S000, S000 PRODUCT DATA Manual Adjustment IMPORTANT To prevent equipment damage, before manual adjustment, you must remove power. The actuator can be operated with no power present. Use this feature during installation or to move and lock the damper or valve shaft position when there is no power. Operating the Manual Positioning To operate the manual positioning with no power, proceed as follows:. If the power is ON, turn it OFF.. Insert the supplied hex wrench (key) as shown in Fig... Rotate the key in the direction indicated on the cover.. Once the desired position has been reached, hold the key to prevent the spring return from moving the actuator.. With the key held in place, use a screwdriver to turn the gear train lock pin in the indicated direction until the detent is reached. NOTE: At the detent, the pin resists further rotation. 6. Remove the key without rotating it further. Releasing the Manual Positioning To release the manual positioning with no power present, proceed as follows:. Insert the supplied key.. Turn the key ¼ of a turn in the direction indicated on the cover.. Remove the key without engaging the gear train lock pin.. The spring will return the actuator to the failsafe position. NOTE: Once power is restored, the actuator will return to normal automated control. 9 Internal End Switches NOTE: Only those actuators for which "-SW" has been specified when ordering (e.g.: "S000-SW") feature internal end switches. The internal end switches are set to switch from "common" to "normally open" at angles of 7 ( ) and 8 ( ), respectively, from the totally counterclockwise position. actuator scale: clockwise -. 0 7 0 7 80 8 90 9. CCW internal CW internal auxiliary switch auxiliary switch end switch scale 0 7 0 7 80 8 90 actuator scale: counterclockwise 9. 90 8 80 7 0 7 0 -. Fig.. Internal end switch triggering points Mechanical Stroke Limit Reduction For applications requiring a span of less than 9, a simple adjustment can be made. When the rotational mounting of the shaft coupling is changed, the actuator drives less than the full 9 stroke. The stroke is adjustable in increments. Once adjusted, the actuator drives until the shaft coupling reaches the mechanical stop (part of the housing). The stop causes the motor to discontinue driving, and the shaft coupling drives no farther. When the actuator returns, it stops at the fail-safe position. To set the fail-safe position, proceed as follows:. Remove the retainer clip from the shaft coupling and set it aside for later use.. Remove the shaft coupling from the actuator.. Rotate the coupling to the desired fail-safe position, aligning it based on the stroke labeling. See Fig.. EXAMPLE: Setting the shaft coupling to an approx. fail-safe position of (as indicated on the housing) limits the stroke to 60 (see Fig. ).. Install the shaft coupling at this position.. Replace the retainer clip on the shaft coupling using the groove of the coupling. 6. If necessary, replace the holder and position indicator on the shaft coupling. Fig.. Manual positioning EN0B-06GE R08

SmartAct S000, S000 PRODUCT DATA Wiring Connecting to the Power Supply In order to comply with protection class II, the power source of V actuators must be reliably separated from the network power supply circuits as per DIN VDE 006, part 0. 90 DRIVE SPRING RETURN 90 STROKE 0 90 DRIVE 60 STROKE SPRING RETURN Fig.. Stroke reduction INSTALLATION These actuators are designed for single-point mounting. IMPORTANT To prevent equipment damage, before manual operation, you must remove power. Mounting Instructions All information and steps are included in the Installation Instructions supplied with the actuator. Mounting Position The actuators can be mounted in any position (IP only when mounted on a horizontal shaft with access cover below the shaft). Choose a mounting position permitting easy access to the actuator's cables and controls. When stationing outdoors, equip with suitable cover to protect against UV and rain. Mounting Bracket and Screws If the actuator is to be mounted directly on a damper shaft, use the mounting bracket included in the delivery package. 0 Access Cover To facilitate wiring the actuator to the controller, the access cover can be detached from the actuator. IMPORTANT Remove power before detaching the access cover. Once the access cover has been removed, please take care to avoid damaging any of the parts now accessible. S S S S S S6 Fig. 6. Access cover (S000-SW) Self-Centering Shaft Adapter The self-centering shaft adapter can be used for shafts having various diameters and shapes (round: 0...7 mm; square:...9 mm). In the case of short shafts, the shaft adapter may be reversed and mounted on the duct side. Stroke The stroke amounts to 9 ( ) and is mechanically limited by end limits (non-adjustable). Fig. 7. S000-SW with access cover removed EN0B-06GE R08

SmartAct S000, S000 PRODUCT DATA Wiring Diagrams S000 / S000 TERMINAL STRIP Vac~ CW CCW 0...0 Vdc Vac~ 0()...0 Vdc U 0...0() Vdc...0 VDC MODULATING...0 VDC MODULATING 0... VDC MODULATING 0... VDC MODULATING 0...0 VDC MODULATING 0()...0 Vdc Y 0...0 VDC MODULATING 0...0() Vdc 0...0 VDC MODULATING 0...0 VDC MODULATING Connect via safety isolating transformer FLOATING CONTROL MODULATING CONTROL Connect via safety isolating transformer S000-SW / S000-SW TERMINAL STRIP Vac~ CW CCW 0...0 Vdc...0 VDC MODULATING 0... VDC MODULATING 0...0 VDC MODULATING 0...0 VDC MODULATING Vac~ 0()...0 Vdc Y 0...0() Vdc 0()...0 Vdc U 0...0() Vdc Connect via safety isolating transformer FLOATING CONTROL MODULATING CONTROL...0 VDC MODULATING 0... VDC MODULATING 0...0 VDC MODULATING 0...0 VDC MODULATING Connect via safety isolating transformer S black S S black S S black S S gray S S gray S S6 gray S6 END SWITCHES NOTE: Internal end switches S and S must be connected to the same power source. EN0B-06GE R08

SmartAct S000, S000 PRODUCT DATA DIMENSIONS MIN. 0... Nm 00 0 0 MIN. 0 MIN. 6 SHAFT ADAPTER SHAFT ADAPTER SUITABLE FOR SHAFTS WITH LENGTH OF... 80 mm MIN. 76 ALTERNATE POSITION WHEN THE SHAFT ADAPTER IS INSTALLED IN ALTERNATE POSITION, THE POSITION INDICATOR IS NOT VISIBLE. 70... 90 7 7 7 MIN. 76 0 mm 0 mm mm ANTI-ROTATION BRACKET 7 mm mm 0 mm Fig. 8. Dimensions (in mm) Manufactured for and on behalf of the Environmental & Energy Solutions Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 6, Switzerland by its Authorized Representative: Home and Building Technologies Honeywell GmbH Böblinger Strasse 7 70 Schönaich, Germany Phone +9 (0) 70 67 0 Fax +9 (0) 70 67 70 http://ecc.emea.honeywell.com EN0B-06GE R08 Subject to change without notice