Off-Line Filter BNF. FluidControl

Similar documents
Off-line filter / cooler unit BKF

Off-line filter units BNF. Installation and Operation Instructions. Original instructions. Fluidcontrol BE /2019

Oil/air cooler BLK. Fluidcontrol

Off-line filter / cooler unit FGSL

Circulation pumps BFP-ATEX-T3/T4

Oil/air cooler BLK. Fluidcontrol

Oil/air cooler BLK ATEX-3GD

Temperature sensors. Fluidcontrol

FA 016 FAPC 016. Oil Service Units. Description. Page 53

GMP-Type. Key Features: Integrated Motor-Pump Units

Cleanline portable. Oil Service Units FA 016 / FAPC 016

OFFLINE SERIES GLOBAL STANDARD COOLER. p f

Feed Pumps VP / VPB / VPBM

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min

Oil / air cooler Series BLK-DC

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm

Type KKP. Combination pumps

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e

Oil Filter Module Pi 8300

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us

Oil Filter Module Pi 8300

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

Installation and commissioning of Settima screw pumps. Type GR** SMT** 3-screw screw pumps. a. Medium:

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

ISO Certificate N 12-E TIC. ISO 9001 Certificate N 12-Q TIC

Off-line Oil Filter Module Pi 8400

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Screwpump. Series D GB. General Description. Model Code D 4

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

Cooling Systems CC Series TT rail 20/30lpm

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

High-pressure pumps Series HP45

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

Return line and Suction Boost Filter RKM

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

Tank top return-line filter Pi 5000

Line filter Pi Features. Nominal pressure 16 bar (230 psi), nominal size 400 up to 6000

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

OFFLINE SERIES GLOBAL STANDARD COOLER

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Valve Technology and Special Solutions for Transmissions on Mobile Machines

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements

Vane pumps, direct controlled Type PV7...A

Low Pressure Filter Pi 2000/Pi 2200

Electric Immersion Pumps PXA and PXK, sealless

Duplex Filter Pi Features. Nominal pressure 25 bar (360 psi), nominal size 800 and 1400

Contents. Identification

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

Oil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048

Duplex Filter Pi Features. Nominal pressure 10/16 bar (140/230 psi), nominal size 1250 up to 8000

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Low pressure filter Spin-on cartridges PX

Duplex Filter Pi 3700

PAC TRAINING PUMP MOTORS

GLOBAL STANDARD COOLER

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

GLOBAL STANDARD COOLER

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

Duplex Filter Pi 2100

Oil/Air Cooler Units

High Pressure Filter Pi 4230

SPIN-ON FILTER - LOW PRESSURE LINE

Medium Pressure Filter Pi 3000

High Pressure Filter Pi 4000

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz

Operating Instructions

Fluid Handling: Panel Unit

HEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground.

UM 045 UMPC 045 Oil service - simple, quick and compact with integrated particle monitor

LMP screw pumps for delivery pressures up to 120 bar

[ T] THREE-PHASE MOTORS «[32] [33] Three-Phase Motors - Technical Catalogue 1018/10

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type

Suction Filter Pi 200

Hydraulic drive power unit Low-noise compact unit Whispering power unit

Instruction Manual. Johnson Ultra Ballast Pump. Johnson Pumps

DUMPER. Data Book 50 Hz

STS SERIES. Enclosed Automated Fuel Maintenance Systems (STS)

THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES

Automatic back-flushing filter AutoFilt RF4

Screw Pump Twin Aggregates Series SPZ/M MagDrive

Series RFL In-Line Filter

Tank top return-line filter Pi 5000

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

Duplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100

HYDAC (Three-Phase Current) Compact Power Units CO1

GLOBAL STANDARD COOLER

DRUM MOTOR 113LP 113.5Ø 0.06kW kW, with planetary gearbox in polymer or polymer / steel combination for non-continuous operation

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

FLUID TRANSFER SECTION 1

Transcription:

FluidControl Off-Line Filter BNF In hydraulic systems oil transfers power and motion, and in drives it s a vital lubricant. Both as a power transfer medium and as a lubricant, oil is heated by friction losses during operation and changes its viscosity depending on the temperature. At the same time it is subjected to mechanical strain due to the tribological processes in the systems and takes on wear particles this causes. If these particles aren t removed as quickly as possible, they will cause further abrasion and wear. Hydraulic and lubrication systems therefore increasingly use bypass filters. The advantage of these circuits is that they create stable and therefore more predictable operating conditions for both the filtration and cooling. The BNF series has compact gerotor pump/filter combinations with different capacities, including custom. The filter housings are suitable for DIN 24550 filter elements. Features Compact, space-saving design DIN filter elements Very easy to install Easy replacement of filter element Low-noise gerotor pump DA380001 11/2017 page 1 / 7 Buhler Technologies LLC, 1030 West Hamlin Road, Rochester Hills, MI 48309 Phone: 248.652.1546 / 49 89-0, Fax: 248.652.1598 e-mail: sales@buhlertech.com Internet: www.buhlertech.com

Introduction and description Why off-line aggregates? Depending on the system configuration there are operating conditions (variable capacity pumps, back-flow peaks, etc.), which significantly limit the effectiveness of full flow filtration or even render it completely ineffective. In addition, quite practical considerations such as installing a cooler with is required anyway or the option of system-independent operation may argue for an off-line aggregate. Why Bühler? When we developed the BNF series, we incorporated our years of experience in designing and selling water coolers and filters. Special attention was paid to a compact design. By using standard filter elements in this respect we are not bound to a specific filter supplier. Together with a well-known manufacturer, Bühler implemented these findings in a comprehensive product line customised for the requirements in fluid control. Use the data in this leaflet to determine a suitable cooler for your application. If our standard range of products does not includes the right system for your application, we will gladly develop a custom solution for you. BNF 18/30 In a filter station it's important to offer a compact design with ample capacity to quickly and permanently clean any given amount of oil. This aspect has been implemented in to a special degree in the BNF series. A low-noise gerotor pump resistant to dirt is integrated into the very compact baseplate. The drive motor and filter housing are arranged vertically and parallel. The suction and pressure line are positioned so they can be routed straight down into the reservoir. This minimises the installation work. Since the baseplate is further equipped with front connections, the aggregate can be cased next to the reservoir, if so desired. The aggregate has a built-in pressure limiting valve. DIN elements with NG 250 are used as filter elements. BNF 60/90 A compact, space-saving design was also realised in this series. Motor, pump and filter housing are combined into one unit and mounted to a frame for side mounting. The DIN filter element with NG 400 removes to the top for changing. Planning information Installation site requirements Ensure adequate ventilation. The aggregates are mounted in the installation site using four screws Electrical connection The electrical connection must be made by an appropriately trained electrician! Observe the voltage and mains frequency! Fusing must comply with applicable standards! Please note the direction of rotation of the motor when connecting. Hydraulic connection Full utilisation of the high capacity of the aggregates requires care when configuring the intake line. This is a very important factor with use in lubricating systems. These are typically filled with higher viscosity oils and must operate reliably in a large temperature range. Although the tremendous increase in viscosity in low temperatures are frequently overlooked. For applications where the parameters are within critical ranges, we recommend calculating the precise expected pressure loss in the suction pipe or using an adequate size (never smaller than the existing pump suction port!). The suction and pressure pipe must be installed free from tension and vibration. When using hoses, pay particular attention to the appropriate reinforcement on the suction side so the hose cannot collapse due to the negative pressure. Do not continuously exceed the recommended suction pressure of the pumps. Some situations may require priming the suction pipe prior to first start-up. Avoid possible leaks in the circuit to prevent environmental damages. If necessary, use e.g. an oil pan. 2 Buhler Technologies LLC We reserve the right to amend specification. DA380001 11/2017

Technical data Technical Data Pump housing: Gerotor: Hydraulic screw joint: Anodised and impregnated cast aluminium Sintered steel Galvanised steel Operating fluids: Mineral oils per DIN 51524 Operating oil temperature: Seal: max. 176 F (higher temperatures on request) Perbunan (NBR) or Viton (FPM) on request Ambient temperature: -4 F to 104 F Electric motors Voltage/frequency BNF 18/30 220/380 V - 230/400 V - 240/415 V 50 Hz 460 V 60 Hz Electr. motor per NEMA; UL, CSA, EAC approval BNF 60/90: Thermal stability: Class of insulation F, utilisation per Class B Design: Degree of protection: on request: The motors comply with standards IEC 60034, IEC 60072, IEC 60085 220/380-245/420 V 50 Hz 220/380-280/480 V 60 Hz no approval three-phase asynchronous squirrel-cage induction motor totally enclosed, fan cooled IP55 other voltages higher motor power for higher viscosities UL- or CSA-approved motors higher protection class Please also observe the operating manual for the motor! All motors are supplied with cable gland inside the terminal box. The total aggregate height may vary by motor make. Installation information: The connection threads are manufactured to ISO 228. The screw-in surfaces are finished and suitable for the use of soft seals. We recommend using screwed plugs per ISO 1179-2. Please note: Especially note the dimension of the suction pipe. The cross-sections should not be smaller than specified. In most cases, loud noise indicates the cross-section was reduced too much. Please refer to the notices in the operating instructions. Wiring diagrams Accessories Wiring diagram BNF 18/30 Wiring diagram BNF 60/90 Accessories Optional: manometer or pressure gauge Optional: manometer or pressure gauge Inlet Output Inlet Output DA380001 11/2017 We reserve the right to amend specification. Buhler Technologies LLC 3

BNF 18 / BNF 30 Contamination indicator (optional) Aggregate mounting diagram Note: When installing next to the oil reservoir please not the intake! When determining the bores on the reservoir be sure the contamination indicators remains visible! Type: BNF 18-6-0.55* BNF 30-4-0.75-IE3* Motor power: 0.75 hp 1 hp Number of pins: 6 4 Power input (460 V 60 Hz): ~ 1.4 A ~ 1.4 A Suction lift: 3.28 ft 3.28 ft Filter element pressure limit: 87 psi 87 psi Display pressure contamination indicator: 32 psi 32 psi Suction end connection: G3/4 / G1 G3/4 / G1 Suction end hose: DN 20 / DN 25 DN 20 / DN 25 Pressure end connection: G3/4 G3/4 Pressure end hose: DN 20 DN 20 Suction pressure: -5.8 psi -5.8 psi For all aggregates briefly: -8.7 psi Flow rate: 5.8 gpm 9.2 gpm Max. feed pressure: 87 psi 87 psi Weight: approx. 40 lb approx. 44 lb *Electr. motor per NEMA; UL, CSA, EAC approval 4 Buhler Technologies LLC We reserve the right to amend specification. DA380001 11/2017

BNF 60 / BNF 90 E-Motor 2.2kW IE3 4-pole / assy. 100 220/380-245/420V 50Hz 220/380-280/480V 60Hz Filter housing NG400 Oil IN Oil OUT Mounting bores 4x Ø0.39 Plug for drain bore Filter housing Note: When installing next to the oil reservoir please not the intake! When determining the bores on the reservoir be sure the contamination indicators remains visible! Contamination indicator (optional) Model: BNF 60-4-2.2-IE3* BNF 90-4-2.2-IE3* Motor power: 3 hp 3 hp Number of poles: 4 4 Power input (460 V 60 Hz): ~ 3.5 A ~ 3.5 A Motor service factor: - - Suction lift: 3.28 ft 3.28 ft Filter element pressure limit: 51 psi 51 psi Display pressure contamination indicator: 32 psi 32 psi Suction end connection: G1 1/2 G1 1/2 Suction end hose: DN 40 DN 40 Pressure end connection: G1 1/4 G1 1/4 Pressure end hose: DN 32 DN 32 Suction pressure: -5.8 psi -5.8 psi For all aggregates briefly: -8.7 psi Flow rate: 18.3 gpm 27.9 gpm max. oil viscosity: 300 cst 100 cst at max. operating pressure 116 psi 116 psi Weight: approx. 75 lb approx. 77 lb *Upon request: Electr. motor per NEMA, UL, CSA, EAC approval DA380001 11/2017 We reserve the right to amend specification. Buhler Technologies LLC 5

Selecting the filter fineness Determining the contamination class per ISO 4406 >4 µm >6 µm >14 µm System type 13 11 8 Highly reliable control systems susceptible to sludge accumulations; laboratory or aerospace 14 16 12 13 9 10 High performance servo systems and high pressure systems with a long life; e.g. aviation, machine tool, etc. 17 15 11 High-quality, reliable systems: general machinery construction 20 17 12 General machinery construction and vehicles; moderate pressure, moderate capacity 23 19 13 General machinery construction and vehicles; low-pressure systems in heavy machinery construction Recommend filter retention rate Recommended element 1-2 Sm-N2 3-5 Sm-x3 Sm-x6 10-12 Sm-x10 12-15 Sm-x16 15-25 Sm-x25 / Mic 10 6 Buhler Technologies LLC We reserve the right to amend specification. DA380001 11/2017

Ordering instructions Off-line filters Item no. Type Description 3802010 BNF 18 without contamination indicator NBR 3802110 BNF 18 mechanical contamination indicator (optional) 3802210 BNF 18 electric contamination indicator NBR 3803020IE3 BNF 30 without contamination indicator NBR 3803120IE3 BNF 30 mechanical contamination indicator (optional) 3803220IE3 BNF 30 electric contamination indicator NBR 3806030IE3 BNF 60 without contamination indicator NBR 3806130IE3 BNF 60 mechanical contamination indicator (optional) 3806230IE3 BNF 60 electric contamination indicator NBR 3809030IE3 BNF 90 without contamination indicator NBR 3809130IE3 BNF 90 mechanical contamination indicator (optional) 3809230IE3 BNF 90 electric contamination indicator NBR Filter elements For type Item no. Description BNF 18 / BNF 30 3825003 N 0250 DN 3 3825006 N 0250 DN 6 3825010 N 0250 DN 10 BNF 60 / BNF 90 3840003 N 0400 DN 3 3840006 N 0400 DN 6 3840010 N 0400 DN 10 DA380001 11/2017 We reserve the right to amend specification. Buhler Technologies LLC 7