Protection and control. Self-reclosing overload and earth leakage protection

Similar documents
Product selection table

Protection and control P. 1 /2. Smart earth leakage protection

CONTENTS. Earth leakage and overload/short circuit protection systems with self-reclosing Associated breaking element

Smart earth leakage protection

New range of reclosing systems

Protection and control P. 1 /2. Smart earth leakage protection

P.1 CONTENTS. Industrial Earth Leakage Protection. Page

Solutions for earth leakage protection and circuit breakers with automatic reclosing system

Electric Switchboards

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

KD LV Motor Protection Relay

01 Spectra Plus - Introduction

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

DPX moulded case circuit breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

COMPLETE SOLUTIONS FOR POWER PROTECTION

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

DMX 3 -I 2500 switch disconnectors

3 - Protection components Motor circuit-breakers

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

RVS-DN Digital Reduced Voltage Motor Starter

Essential equipment for all your requirements

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Components for EEx e Panels

Industry Automation Control Components

Power protection solutions

Electronic Ballast EVG 2000-T

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

(p. 47) (p. 155) (p. 155)

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

dx 3 protection that meets your requirements GloBal SpecialiSt IN electrical AND DIgITAl BUIlDINg INFrASTrUCTUreS catalogue pages inside

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION

Ktec Contactors and thermal overloads

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Moulded case circuit breakers

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Thermal Overcurrent Circuit Breaker 3120-F...

TECHNICAL DESCRIPTION

Thermal-magnetic Miniature Circuit Breaker 4230-T...

RESIDUAL CURRENT CIRCUIT BREAKER

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Thermal Overcurrent Circuit Breaker 3120-F...

Bulletin 825 SMM Smart Motor Manager

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

Thermal Overcurrent Circuit Breaker 3120-F...

Pluggable interface relays RT, PT and MT range

DPX earth leakage DPX 3 -I earth leakage

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Thermal Overcurrent Circuit Breaker 3120-F...

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Thermal Overcurrent Circuit Breaker 3120-F...

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

1 Phase electronic contactor (SC 1)

Series KTU7 UL489 Molded Case Circuit Breakers

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

DPX 1600 Electronic release

RVS-DX Digital Reduced Voltage Motor Starter

AME. Rectifier - Battery charger. Industrial applications: Key features:

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

New DX 3 High rating & breaking capacity

CPG.0 Single busbar gas-insulated cubicles

Miniature Circuit Breaker

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Series KTU7 UL489 Molded Case Circuit Breakers

Low Voltage A GE Power Controls Company. General catalogue

22AF 40AF AF 150AF 225AF 400AF 800AF

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

3VU13, 3VU16 Circuit-Breakers

ACS motor protection circuit breakers KT 7 Introduction

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

PIX-H Metal-clad switchgear up to 17.5kV

Miniature Circuit Breakers

MINIATURE CIRCUIT BREAKER

Manual Motor Starters. Meta-MEC

SPEEDRIVE INSTRUCTIONS MANUAL

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Application Engineering

Thermal Overcurrent Circuit Breaker 3120-F...

Miniature Circuit-Breakers (MCBs)

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Scheda prodotto Relè Series B

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Motor Protection Circuit Breakers 3VU13 and 3VU16

SYSDrive Frequency Inverter

Transcription:

Protection and control Self-reclosing overload and earth leakage protection

P2- Self-reclosing overload and earth leakage protection REC2 Self-reclosing earth leakage relay P2-5 WRU RA Earth leakage relay with built-in transformer P2-7 WRU-10 RAL Differential relay with built-in transformer and display (type A) P2-9 RGU-10 RAL Earth protection Relay WG Series P2-11 CBS-4 RA / RAL Earth leakage relay station WG / WGC Series P2-13 CBS-8 Earth leakage monitoring and signaling unit of the external transformer of the WG / WGP / WGC Series P2-15 WRKRT-25 Earth leakage relay with built-in transformer P2-17 MCB MCB Series Circuit-Breaker P2-19 WRU-25 RA-MT Earth leakage relay with built-in transformer P2-21 WRT-6 Earth leakage relay with built-in transformer P2-23 WRU-10 MT Earth leakage relay with built-in transformer and display (type A) P2-25 t RGU-10 MT Earth leakage Relay WG + MT Series P2-27 RGMT Earth leakage Relay WG + MT Series P2-29 RECmax MP Motorized circuit breaker (up to 63 A) P2-31 MT Motorized circuit breaker (up to 63 A) P2-33 MT-FDE Motorized circuit-breaker (from 63 A) P2-35 P2-2

WRGMT Complete overload and earth leakage protection and reclosure equipment P2-37 RECmax P Self-reclosing motorized circuit breaker (up to 63 A) P2-38 RRM Overload reclosing relay P2-40 P2-3

Product selection table Equipment Protection Reclosure Associated circuit breaker External toroidal Page REC2 Earth leakage switch -- P2-5 WRU RA Contactor -- P2-7 WRU-10 RAL Contactor -- P2-9 RGU-10 RAL Contactor Tipo WG / WGC P2-11 CBS-4 RA Contactor Tipo WG / WGC P2-13 CBS-8 Contactor Tipo WG / WGP / WGC P2-15 WRKRT-25 + circuit breaker Circuit-breaker MCB-T / MCB-P -- P2-17 WRU-25 RA-MT + circuit breaker + circuit breaker Circuit breaker MT Type WG P2-21 WRT-6 + circuit breaker + circuit breaker Circuit breaker MT -- P2-23 WRU-10 MT + circuit breaker + circuit breaker Circuit breaker MT -- P2-25 RGU-10 MT + circuit breaker + circuit breaker Circuit breaker MT Tipo WG / WGC P2-27 RGMT + circuit breaker + circuit breaker Circuit breaker MT -- P2-29 WRG-MT + circuit breaker + circuit breaker Circuit breaker MT -- P2-37 RRM Circuit breaker Circuit breaker Circuit breaker MT -- P2-40 P2-4

Earth leakage protection and self-reclosing RCCB with Self-reclosing system REC2 Self-reclosing earth leakage relay Description REC2 is a 2 or 4-pole earth leakage switch associated to a compact motor and control set that enables the automatic and safe reclosure of the installation, provided that the leakage is not permanent. Output contact available in REC2C model Protection Class Measurement Sensitivity I Dn Delay Test Electromechanical, Class A Instantaneous value 30 ma or 300 ma (depending on the type) Fixed at 20 ms With built-in button The earth leakage switch is reclosed automatically, in accordance with the work mode selected (switch on the front): Time sequence mode: after a switch trip, REC2 will make 6 reclosing attempts, with a timer set at 10, 20, 30, 60, 120 and 600 s. If the set can not be reclosed, it will be blocked in a trip status until it is reset manually. Insulation monitoring mode: after the switch trip, REC2 repeats the previous sequence, but it measures the presence of leakage current in the installation before carrying out the reset. REC2 will only reclose when the insulation measurements are correct. There are LEDs on the front part of the control module to indicate the operation status: Manual or automatic reclosure Reclosure mode selected Reclosing status Lock status Drop-down window to activate/deactivate the automatic reclosure of the earth leakage switch. Reset Manual (front cover) Associated circuit breaker Built-in I n and no. of poles I n 40 A or 63 A, Poles 2 or 4 (depending on the type) Circuit breaker control Electromechanical relay Reclosure No. of reclosures 6 Time between reclosures 10, 20, 30, 60, 120, 600 s Partial counter reset time 600 s (reset time after 30 s) Reclosure cancellation With the front cover Nominal voltage 2 poles: 230 Vac 4 poles: 230 / 400 Vac Auxiliary power supply 230 Vac, 50... 60 Hz Operating temperature -25... +55 ºC Hose features (only REC2C) Connector Hose Length Build features Fixing Weight Degree of protection IP 40 Standards IEC 61008-1, IEC 255-5 JST BHR-02VS-1 YY 2x0.22, PVC 80-300 V 750 mm DIN rail 2 poles: 5 modules (90 x 90 mm) 4 poles: 7 modules (125 x 90 mm) 2 poles: 560 g / 4 poles: 693 g P2-5

Earth leakage protection and self-reclosing Self-reclosing earth leakage switch REC2 Self-reclosing earth leakage device References With output contact Class Poles I n (A) Sensitivity Type Code Type Code A 2 40 30 ma REC2-2P-40-30 P26411 REC2C-2P-40-30 P26611 A 2 40 300 ma REC2-2P-40-300 P26321 REC2C-2P-40-300 P26521 A 2 63 30 ma REC2-2P-63-30 P26414 REC2C-2P-63-30 P26614 A 2 63 300 ma REC2-2P-63-300 P26324 REC2C-2P-63-300 P26524 A 4 40 30 ma REC2-4P-40-30 P26412 REC2C-4P-40-30 P26612 A 4 40 300 ma REC2-4P-40-300 P26322 REC2C-4P-40-300 P26522 A 4 63 30 ma REC2-4P-63-30 P26415 REC2C-4P-63-30 P26615 A 4 63 300 ma REC2-4P-63-300 P26325 REC2C-4P-63-300 P26525 REC2-2 poles REC2-4 poles Connections REC2 F N 230 Vac - 50 Hz 1 N 2 N 13 mm MAX. 16-25 mm 2. CARGA REC2C - output contact 13 mm MAX. 16-25 mm 2. F N 230 Vac - 50 Hz 1 N Motor Reconexion Automatica Contacto auxiliar Auxiliary contact 2 N CARGA / LOAD Contacto auxiliar P2-6

Earth leakage protection and self-reclosing Earth leakage relay + contactor WRU RA Earth leakage relay with built-in transformer Description Self-reclosing electronic earth leakage protection relay with built-in transformer, a diameter of Ø 25 or Ø 35 mm (depending on the type), with earth leakage trigger It is connected to a contactor or similar element as a circuit breaker Type A relay, with high-frequency current filtering and high immunity. Monitoring in true root mean square (TRMS) Adjustable sensitivity and trigger timer. Number of reclosures and time between them, depending on the relay type Leakage level trigger indicator LED (% sensitivity): y1 flash every 2 s: between 25 and 50 % y1 flash every 1 s: between 50 and 75 % y1 flash every 0.5 s: between 75 and 90% ypermanent: Earth leakage protection trigger Adjustable to the DIN profile 46277 (EN -50022) Application Said relays are connected to a contactor or similar element to guarantee the level of self-reclosing earth leakage protection after a trigger. It is very easy to install, so that it is the adequate solution for installations that require the use of earth leakage protection systems as a result of their location or position in a determined site, which makes them hard to supervise or access: lighting panels, telephony installations, television repeaters, refrigeration chambers, etc. Protection Class Measurement Sensitivity Delay Earth leakage transformer Test and Reset Associated circuit breaker I n and no. of poles Circuit breaker control Reclosure No. of reclosures 6 Time between reclosures Partial counter reset time Relay signaling LED Remote signaling (outputs) Remote Control (inputs) A superimmunized True root mean square (TRMS) Adjustable from 30 ma... 3 A Adjustable from 20 ms... 1 s Built-in With built-in button Contactor Defined by the contactor used With switched relay 8, 16, 30, 59, 115, 224, s 15 min Presence of voltage Leakage current level Triggered relay Leakage control signal (mvac / ma) External test with button Auxiliary power supply 230 Vac (± 20 %) 50 / 60 Hz Output contacts 250 Vac, 6 A Operating temperature -10... +50 ºC Construction features Fixing DIN rail 4 modules (WRU-25 RA) / 6 modules (WRU-35 RA) Weight 236 g (WRU-25 RA) / 415 g (WRU-35 RA) Degree of protection IP 20 Terminals, IP 41 back panel Standards IEC 61008-1, IEC 755, IEC 255-5 P2-7

Earth leakage protection and self-reclosing Earth leakage relay + contactor WRU RA Earth leakage relay with built-in transformer WRU-25 RA / WRU-RM / WRU-RT / WRU-25-2R WRU-35 RA References Useful diameter Ø (mm) I n (A) Delay (s) (*) Number of reclosures Time between reclosures (s) Control of the circuit breaker Remote signaling (outputs) Type Code 25 0,03... 3 0,02... 1 6 8,16, 30,59,115,224 Switched relay mv ac proportional to the leakage current WRU-25 RA P24211 35 0,03... 3 0,02... 1 6 8,16, 30,59,115,224 Switched relay mv ac proportional to the leakage current WRU-35 RA P24221 Other earth leakage relays 25 0,03... 3 0,02... 1 30 20 s, 40 s and the rest every 5 min Switched relay mv ac proportional to the leakage current WRU-RM P24231 25 0,03... 3 0,02... 1 30 20 s, 40 s and the rest every 5 min Simple relay, NO, positive safety Alarm relay: 1 simple relay NO-SP WRU-RT P24431 25 0,03... 1 0,02 31 2 min, 4 min and the rest every 6 min Simple relay NO Alarm relay: 1 simple relay NO WRU-25-2R P24412 (*) The delay is cancelled in all relays with a sensitivity adjustment of 0.03 A. P2-8

Differential protection and reclosing Differential relay with integrated toroidal transformer + contactor WRU-10 RAL Differential relay with built-in transformer and display (type A) Description Electronic differential protection relay with automatic reclosing with built-in 28 mm transformer, constituting one unit. Superimmunized Type A, with high-frequency current filter and high insulation. Measurement in true root mean square (TRMS) value Display with leds and back-lit display: - Differential protection/reclosing settings - protection trigger current. - number of reclosures - protection status messages, etc. Unit with three output contact relays one switched and two simple relays, all programmable. The main relay provides the protection associated with the contactor, one is for the pre-alarm and the other for locking once the maximum number of reclosures is reached. There is a voltage input for external triggering and reclosing Fitting: DIN 46277 (EN-50022) profile Reduced three-module size. Connection by pluggable terminals Application The WRU-10 RAL relays combined with a CONTACTOR provide automatic reclosure following an event and provide a suitable solution for public lighting, automatic cash machines, cold rooms, traffic lights, etc. Its characteristics have been designed to provide maximum safety and continuity of the electrical service, avoiding untimely triggers. Protection Class Measurement PROGRAMMABLE sensitivity PROGRAMMABLE delay Test and Reset Associated circuit breaker Circuit breaker control Reclosure No. of reclosures Time between reclosures Reclosure time counter Relay signaling LED INDICATORS/BACK-LIT DISPLAY Remote Control A superimmunized True root mean square (TRMS) 0.03...3A, extendible to 30 A using SETUP Time setting: 0.02...1 s, up to 10s using SETUP. Inverse curve: INStantaneous/ SELective. IEC 60947-2 By built-in buttons, T & R CONTACTOR, defines the number of poles and the I n Switched NO/NC contact relay Programmable Power supply Leakage trigger Pre-alarm Locking Protection settings Leakage current/trigger reading TEST and external status Sequences/reclosure number External TEST possible, triggering by voltage input Auxiliary power supply 230 Vac (± 30%) 50 / 60 Hz Output contacts 250 V ac, 5 A / 230 V ac, 250 ma Operating temperature -20... + 70 ºC Construction features Fixing DIN rail 3 modules Weight 275 g Degree of protection IP 20, trans-cabinet IP 41 Standards IEC 60947-2, IEC 60755, IEC 62020, IEC 61008 P2-9

Differential protection and reclosing Differential relay with integrated toroidal transformer + contactor WRU-10 RAL Differential relay with built-in transformer and display (type A) R eferences N reclosures Time between reclosures Net section (mm) I n (A) Delay Type Code Programmable Ǿ 28 0.03... 3 A extendible to 30 A 0.02... 1 s extendible to 10s Inverse curve: INS/SEL WRU-10 RAL P24453 Connections Programmable Reclosure P2-10

Earth leakage protection and self-reclosing Earth protection relay + contactor + external transformer RGU-10 RAL Earth protection Relay WG Series Description Electronic earth leakage protection relay, used to connect the external toroidal transformers of the WG / WGS / WGC Series Self-reclosing with a programmable earth leakage trip Superimmunized type A Relay, with high frequency current filtering and high immunity. Monitoring in true RMS The backlight display shows the following information: yadjustment values yinstantaneous leakage current It has two independent outputs: ytrip relay yend-of-reclosing-sequence interlocking relay External input for remote control functions (230 Vac) Automatic test of the connection and external transformer status Optional RS-485 Communications: type RGU-10C RAL Reduced dimensions: 3 modules Assembly on DIN rail 46277 (EN-50022). Optional assembly on 72 x 72 panel with accessory M5ZZF1. Application The RGU-10 RAL relays associated to a meter allow the automatic reclosing after a trigger, thus offering the most adequate solution for public lighting, cash machines, refrigeration chambers, traffic lights, etc. Its design characteristics guarantee maximum security and continuity of the electrical service, avoiding unwanted tripping. Protection Class Measurement Sensitivity Delay Earth leakage transformer Test and Reset Associated circuit breaker I n and no. of poles Circuit breaker control Reclosure No. of reclosures Time between reclosures Partial counter reset time Relay signaling LED Display Remote signaling (outputs) Remote Control (inputs) A superimmunized True root mean square (TRMS) Programmable from 30 ma... 30 A Programmable from 20 ms... 10 s Inverse curve: instantaneous or selective External, WG Series (WG / WGS / WGC) With built-in button Contactor Defined by the contactor used With a switched relay Programmable: Depending on the reclosing sequence Programmable: 1... 900 s Programmable Presence of voltage Leakage trip Interlocking / reclosing status Backlit LCD Lock status indicator relay ON / OFF Auxiliary power supply 230 Vac (± 20 %) 50 / 60 Hz Output contacts 250 Vac, 6 A Operating temperature -10... +50 ºC Construction features Fixing DIN rail 3 modules Weight 236 g Degree of protection IP 20 Terminals, IP 41 back panel Standards IEC 61008-1, IEC 755, IEC 255-5 P2-11

Earth leakage protection and self-reclosing Earth protection relay + contactor + external transformer RGU-10 RAL Earth protection Relay WG Series References Reclosing element Communications I n (A) Delay (s) Type Code Contactor - 0,03... 30 0,02... 10 RGU-10 RAL P24622 Contactor RS-485 0,03... 30 0,02... 10 RGU-10 C RAL P24662 Connections P2-12

Earth leakage protection and self-reclosing Earth leakage station + contactor + external transformer CBS-4 RA / RAL Earth leakage relay station WG / WGC Series Description Unit equivalent to 4 earth leakage protection relays. 4 independent programmable relays available 4 inputs to connect the external toroidal transformers of the WG / WGS / WGC Self-reclosing with programmable earth leakage trip in each channel Superimmunized Type A relay with high frequency current filtering and high immunity. Monitoring in true root mean square (TRMS) Reduced size: 3 modules 5 independent programmable outputs: y4 earth leakage trip outputs y1 end-of-reclosing-sequence interlocking output Backlight display to show the information of the 4 channels: yadjustment values yinstantaneous leakage current Trip/external reset input Automatic test of the connection and status of each external transformer Optional RS-485 Communications: type CBS-4C RA and CBS-4C RAL Assembly on DIN rail 46277 (EN-50022) Optional assembly on 72 x 72 panel with accessory M5ZZF1. Protection Class Measurement Sensitivity I Dn Delay Earth leakage transformer Test and Reset Associated circuit breaker I n and no. of poles Reclosure No. of reclosures Time between reclosures Partial counter reset time A superimmunized True root mean square (TRMS) 0.03 A... 30 A Programmable: 0.20 ms... 10 s Inverse curve: instantaneous or selective External, WG Series (WG / WGS / WGC) With built-in button Contactor Defined by the contactor used Programmable Programmable Programmable Auxiliary power supply 230 Vac (± 20 %) 50... 60 Hz Contacts with 4 earth leakage outputs 250 Vac, 5 A Operating temperature -10... +50 ºC Construction features Fixing DIN rail 3 modules Weight 236 g Degree of protection IP 20 Terminals, IP 41 back panel Standards IEC 61008-1, IEC 755, IEC 255-5 Application CBS-4 RA or CBS-4 RAL allow an intelligent earth leakage protection, with greatly reduced dimensions. A contactor is available per channel, enabling the automatic reclosure after a trip, thus offering the most adequate solution for public lighting, cash machines, refrigeration chambers, traffic lights, etc. In addition, version CBS-4 C, with RS-485 communications, is used with the PowerStudio software and it adds the centralised supervision in real-time, as well as a record log that can be analysed later on. P2-13

Earth leakage protection and self-reclosing Earth leakage station + contactor + external transformer CBS-4 RA / RAL Earth leakage relay unit WG / WGC Series References Size Communications No. of Relays No. of reclosures Type Code 3 modules - 4 / NO Programmable CBS-4 RA P24911 3 modules RS-485 4 / NO Programmable CBS-4 C RA P24912 3 modules - 4 / NC Programmable CBS-4 RAL P24A11 3 modules RS-485 4 / NC Programmable CBS-4 C RAL P24A12 Connections P2-14

Earth leakage protection and self-reclosing Earth leakage station + contactor + external transformer CBS-8 Earth leakage monitoring and signaling unit of the external transformer of the WG / WGP / WGC Series Description Unit equivalent to 8 earth leakage protection networks. 8 independent programmable relays available 8 inputs to connect the external toroidal transformers of the WG / WGP / WGC Superimmunized Type A relay with high frequency current filtering and high immunity. Monitoring in true root mean square (TRMS) Reduced size, with 8 modules 9 independent programmable outputs (8 earth leakage trip relays and 1 pre-alarm trip). Application The CBS-8 earth leakage station associated to the transformers of the WG / WGP / WGC Series allows an intelligent earth leakage protection. Its design features guarantee maximum security and continuity of the electrical service, avoiding unwanted tripping. Showing the value of the leak instantaneously on the display with the pre-alarm indications provides the information about the state of lines being protected, thus allowing the implementation of an adequate preventive maintenance approach. In addition, RS-485 communications are used with the PowerStudio software, which allows the centralised supervision of the system in real time, with a record log that can be analysed later on. Protection No. of protections 8 Class A superimmunized Measurement True root mean square (TRMS) Sensitivity 0.03 A... 6.3 A external transformers WG/WGS 0.03 A... 63 A external transformers WGP/WGSP Delay Earth leakage transformer Test and Reset Associated circuit breaker Time defined: 0,02... 10 s Inverse curve: instantaneous or selective External, TRANSFORMERS WG / WGP / WGC With built-in buttons, T & R Contactor or circuit breaker + trigger coil Automatic reclosing No. of reclosures 0 Programming option... 10 Time between reclosures 0 Programming option... 900 s Partial counter reset time Double the reclosing time Power supply voltage Leakage trip LED indicator Pre-alarm Interlocked earth leakage reclosing Automatic reclosure enabled Instantaneous leak level indicator in each channel Display View Parameter programming Reclosure status Auxiliary power supply 230 Vac (± 20 %) 50... 60 Hz Output contacts 250 Vac, 5 A Operating temperature -10... +50 ºC Construction features Fixing DIN Rail 46277 (EN 50022) 8 modules Weight 609 g Degree of protection IP 20 Terminals, IP 41 back panel Standards IEC 664, VDE 0110, IEC 801, UL 94, IEC 348, IEC 571-1, EN 61000-6-3, 61000-6-1, 61010-1 P2-15

Earth leakage protection and self-reclosing Earth leakage station + contactor + external transformer CBS-8 Earth leakage monitoring and signaling unit of the external transformer of the WG / WGP / WGC Series 110 45 140 70 References Size Communications No. of Relays I n (A) Type Code 8 modules RS-485 8 0,03... 63 CBS-8 (*) P12811 (*) In the case of the 0.3... 63 A scale, use earth leakage transformers of the WGP / WGSP (*) In the case of the 0.03... 6.3 A scale, use earth leakage transformers of the WG / WGS Connections P2-16

Overcurrent and earth leakage protection and self-reclosing Earth leakage relay + MCB circuit-breaker WRKRT-25 Earth leakage relay with built-in transformer Description Self-reclosing earth leakage protection relay with a built-in transformer, with a diameter of Ø 25 mm, with automatic reclosure in case of a trip. Its operation is always associated to an MCB circuit-breaker. Therefore, other models can not be used The WRKRT-25 relay is used with the MCB to guarantee the self-reclosing earth leakage and overload protection, with an automatic reclosure after an earth leakage trip Type A relay with high frequency current filtering and high immunity. Monitoring in true root mean square (TRMS) Adjustable sensitivity and timer. Application The WRKRT-25 Relays connected to an MCB circuit-breaker guarantee self-reclosing earth leakage and overload protection, with an automatic reclosure after an earth leakage trip. It is a very good solution in installations in special locations that are hard to monitor and guard: telephony installations, television repeaters, refrigeration chambers, etc. Protection Class Measurement Sensitivity Delay Earth leakage transformer Test and Reset Associated circuit breaker I n, No. of poles, thermal curve and cut-out power Reclosure A superimmunized True root mean square (TRMS) Programmable from 30 ma... 3 A Programmable from 20 ms... 1 s Incorporated, Ø 25 mm With built-in button Circuit-breaker MCB-T (WRKRT-25 T) and MCB-P (WRKRT-25 N) Defined by the circuit-breaker used, up to 63 A No. of reclosures 30 (WRKRT-25 T) and 6 (WRKRT-25 N) Time between reclosures Partial counter reset time Relay signaling LED Control input (R1-R2) 20 s, 40 s, the remaining 28 every 5 min 15 min Voltage presence indicator Interlocked reclosure Indicates the presence of leakage current that does not reach the trip point WRKRT-25 T: External reset WRKRT-25 N: Connection/disconnection order of the associated MCB-P Auxiliary power supply 230 Vac (± 20 %) 50 / 60 Hz Breaking element control contacts Maximum current 3 Aac Operating temperature -10... +50 ºC Construction features Fixing DIN rail 4 modules Weight 235 g Degree of protection IP 20 Terminals, IP 41 Embedded relay Standards IEC 61008-1, IEC 755, IEC 255-5, IEC 947-2 P2-17

Overcurrent and earth leakage protection and self-reclosing Earth leakage relay + MCB circuit-breaker WRKRT-25 Earth leakage relay with built-in transformer WRKRT-25 T / WRKRT-25 N References No. of rec. Time between reclosures I n (A) Delay (s) (* 1 ) Associated circuit breaker Type Code 30 20s, 40 s and the rest every 5 min 0,03... 3 0,02... 1 Circuit-breaker MCB-T WRKRT-25 T P23111 6 0.5/1/2/4/8/16 min 0,03... 3 0,02... 1 Circuit-breaker MCB-P WRKRT-25 N (* 2 ) P23121 Up to 63 A and 2 and 3+N poles (* 1 ) The delay is cancelled in all relays with a sensitivity adjustment of 0.03 A. (* 2 ) Only valid for overload relays of the MCB-P Series. External contactor input. Connections WRKRT-25 T WRKRT-25 N External reset Leakage control CONTROL INPUT LOAD Auxiliary contacts (white) Common (brown) Circuit breaker statu (green) Earth leakage status LOAD P2-18

Overcurrent and earth leakage protection and self-reclosing MCB MCB Series Circuit-Breaker Description MCB-P or MCB-T are circuit-breakers that combine the functions of a circuit breaker (overload and short-circuit protection) and those of a contactor on the same element. There are two options with MCB: Closed circuit-breaker: Allows remote control functions (contactor function). It can be disconnected and reconnected electrically with the adequate signal. Circuit-breaker opened by an overload or short-circuit trip or by manual disconnection: remote control reset is not allowed, only manually. The remote control function works on the same contacts as those of the circuit breaker, guaranteeing the disconnection in each case. The MCB-T type includes a remote control module with two auxiliary, potential free (three-wire) contacts that indicate the status of the MCB at the input of the remote control (contactor function) and/or the circuit breaker. Circuit-breaker Gauges I n (A) 6-10 - 16-20 - 25-32 - 40-50 - 63 Nominal cut-out power (EN 60898) 6... 63 A: 10 ka Nominal cut-out power (EN 60947-2) 6... 16 A: 20 ka 20... 63 A: 15 ka Typical curve Nominal working voltage Work frequency range C or D, depending on the type 230 / 400 Vac 50... 60 Hz Operating temperature -25... +55 ºC Storage temperature -40... +70 ºC Remote Control Nominal voltage Activation impulse Deactivation impulse Construction features Fixing Mechanical working life Weight 230 Vac 20 ms 20 ms DIN rail 2 poles: 3 modules 4 poles: 5 modules 20,000 operations 2 poles: 375 g 4 poles: 615 g Degree of protection IP 20 (DIN 40050) Standards IEC 60898, EN 60947, EN 60898, IEC 60947-2 Application MCB are the perfect elements to guarantee self-reclosing earth leakage and overload protection applications, connected to WRKRT-25 relays. P2-19

Overcurrent and earth leakage protection and self-reclosing MCB MCB Series Circuit-Breaker MCB-P / MCB-T References 2 poles 4 poles MCB-P MCB-T MCB-P MCB-T I n (A) Type Code Type Code Type Code Type Code 6 MCB-P C-2p-6A P20210 MCB-T C-2p-6A P20310 - - - - 10 MCB-P C-2p-10A P20211 MCB-T C-2p-10A P20311 MCB-P C-4p-10A P20221 MCB-T C-4p-10A P20321 16 MCB-P C-2p-16A P20213 MCB-T C-2p-16A P20313 MCB-P C-4p-16A P20223 MCB-T C-4p-16A P20323 20 MCB-P C-2p-20A P20214 MCB-T C-2p-20A P20314 MCB-P C-4p-20A P20224 MCB-T C-4p-20A P20324 25 MCB-P C-2p-25A P20215 MCB-T C-2p-25A P20315 MCB-P C-4p-25A P20225 MCB-T C-4p-25A P20325 32 MCB-P C-2p-32A P20216 MCB-T C-2p-32A P20316 MCB-P C-4p-32A P20226 MCB-T C-4p-32A P20326 40 MCB-P C-2p-40A P20217 MCB-T C-2p-40A P20317 MCB-P C-4p-40A P20227 MCB-T C-4p-40A P20327 50 MCB-P C-2p-50A P20218 MCB-T C-2p-50A P20318 MCB-P C-4p-50A P20228 MCB-T C-4p-50A P20328 63 MCB-P C-2p-63A P20219 MCB-T C-2p-63A P20319 MCB-P C-4p-63A P20229 MCB-T C-4p-63A P20329 Connections N RELAY K SERIE ON OFF 1 2 MCB control mod 230 V ac LOAD L 3 P2-20

Overcurrent and earth leakage protection and self-reclosing Earth leakage relay + circuit breaker WRU-25 RA-MT Earth leakage relay with built-in transformer Description Self-reclosing earth leakage protection relay with a built-in transformer, with a diameter of Ø 25 mm, with automatic reclosure in case of a trip. It is connected to a motorized circuit breaker of the MT or similar series as the overload protection or circuit breaker element. Self-reclosing system after an overload and/or earth leakage trip. Type A relay, with high current filtering and high immunity. Monitoring in true root mean square (TRMS). The functions of the WRU-25 RA-MT are: yearth leakage protection and self-reclosing yoverload reclosing Leakage level trigger indicator LED (% sensitivity): y1 flash every 2 s: between 25 and 50 % y1 flash every 1 s: between 50 and 75 % y1 flash every 0.5 s: >75 and <90% ypermanent: Earth leakage protection trigger Application The WRU-25 RA-MT relays connected to an MT or similar circuit breaker guarantee the self-reclosing earth leakage and overload protection of a system after a trip, with both earth leakage and overload protection systems. It is a very good solution in installations in special locations that are hard to monitor and guard: telephony installations, television repeaters, refrigeration chambers, etc. Protection Class Measurement Sensitivity Delay Earth leakage transformer Test and Reset Associated circuit breaker I n and no. of poles Circuit breaker control Reclosure No. of reclosures 6 Time between reclosures Partial counter reset time Safety interlocking Relay signaling LED Remote signaling (outputs) Earth leakage and circuit breaker A superimmunized True root mean square (TRMS) Programmable from 30 ma... 3 A Programmable from 20 ms... 1 s Built-in Ø 25 mm With built-in button Motorized circuit-breaker MT Defined by the circuit breaker used With a switched relay Earth leakage and circuit breaker 1 min 15 min In the earth leakage protection device. With disconnection lever Voltage presence indicator Earth and/or short-circuit overload fault indicator Leakage control signal (proportional alternating voltage) Auxiliary power supply 230 Vac (± 20 %) 50 / 60 Hz Circuit breaker control contacts 250 Vac, 8 Aac Output contacts Maximum current 3 A Operating temperature -10... +50 ºC Construction features Fixing DIN rail 4 modules Weight 234 g Degree of protection IP 20 Terminals, IP 41 back panel Standards IEC 61008-1, IEC 755, IEC 255-5 P2-21

Un 230VAC T E S T R E E T type WRU25 POWER Un 230VAC T E S T R E E T type WRU25 POWER Self-reclosing overload and earth leakage protection Overcurrent and earth leakage protection and self-reclosing Earth leakage relay + circuit breaker WRU-25 RA-MT Earth leakage relay with built-in transformer References No. of reclosures Useful diameter Ø (mm) I n (A) Delay (s) (*) Time between reclosures Associated circuit breaker Type Code 6 25 0,03... 3 0,02... 1 1 min Switch MT WRU-25 RA-MT P24241 (*) The delay is cancelled in all relays with a sensitivity adjustment of 0.03 A. Connections WRU-25 RA-MT (self-reclosing earth leakage and overload protection) L3 L2 L1 N WRU-25 RA-MT (self-reclosing, only earth leakage) RED L3 L2 L1 N 1 3 5 7 12 14 1 3 5 7 12 14 N N L MT L M On I H Off 0 MT 2 4 6 8 M On I Off 0 11 2 4 6 8 11 A1/Y2 A1 Y1 18 16 A1/Y2 A1 Y1 18 16 T T R S R S Z1 Z2 15 A2 Z1 Z2 15 A2 MV MV LOAD LOAD P2-22

Overcurrent and earth leakage protection and self-reclosing Earth leakage relay + circuit breaker WRT-6 Earth leakage relay with built-in transformer Description Self-reclosing protection relay with a builtin transformer, with a diameter of Ø 25 mm, with automatic reclosure in case of a trip. It is connected to a motorized circuit breaker of the MT or similar series, acting as the earth leakage protection element or circuit breaker Self-reclosing earth leakage and/or overload trigger Type A relay, with high frequency current filtering and high immunity. Monitoring in true root mean square (TRMS) The WRT-6 has the following functions: yearth leakage protection and self-reclosing yoverload reclosing Visualisation of the following on the LED display: yinstantaneous leakage current value ytotal reclosing no. meter One output (potential free) to indicate the reclosing interlocking. Application The WRT-6 relays connected to an MT or similar circuit breaker guarantee the selfreclosing earth leakage and overload protection of a system after a trip, with both earth leakage and overload protection systems. It is a very good solution in installations in special locations that are hard to monitor and guard: telephony installations, television repeaters, refrigeration chambers, etc. Protection Class Measurement Sensitivity Delay Earth leakage transformer Test and Reset Associated circuit breaker I n and no. of poles Circuit breaker control Reclosure No. of reclosures Time between reclosures Partial counter reset time Safety interlocking Earth leakage and circuit breaker A superimmunized True root mean square (TRMS) Fixed 30 ma or 300 ma (depending on the type) Fixed 20 ms Built-in Ø 25 mm With built-in button Motorized circuit-breaker MT Defined by the circuit breaker used With ON / OFF Relay Earth leakage and circuit breaker 2 circuit breaker and 10 earth leakage 1 min 30 min In the earth leakage protection device. With disconnection lever Auxiliary power supply 230 Vac (± 20 %) 50 / 60 Hz Circuit breaker control contacts 250 Vac, 8 Aac Output contacts 250 Vac, 8 Aac Operating temperature -10... +50 ºC Construction features Fixing DIN rail 6 modules Weight 425 g Degree of protection IP 20 Terminals, IP 41 Embedded relay Standards IEC 61008-1, IEC 755, IEC 255-5 P2-23

Overcurrent and earth leakage protection and self-reclosing Earth leakage relay + circuit breaker WRT-6 Earth leakage relay with built-in transformer References No. of reclosures Useful diameter Ø (mm) I n (A) Delay (s) (*) Poles Control of the circuit breaker Type Code 2 circuit breaker 10 earth leakage 25 0,03 0,02 in accordance with MT ON / OFF Relay WRT-6-25 0.03 P21121 2 circuit breaker 10 earth leakage 25 0,3 0,02 in accordance with MT ON / OFF Relay WRT-6-25 0.3 P21122 (*) The delay is cancelled in all relays with a sensitivity adjustment of 0.03 A. Connections LOAD SEAL SIGNAL P2-24

Overcurrent and earth leakage protection and self-reclosing Relé diferencial con toroidal integrado + magnetotérmico motorizado WRU-10 MT Earth leakage relay with built-in transformer and display (type A) Description Electronic earth leakage protection relay with automatic reclosing with built-in 28 mm transformer, forming a single unit. Superimmunized type A, with high-frequency current filter and high immunity. True root mean square measure (TRMS) Display with LEDs and backlight display: - Earth leakage reclosing / protection parameters - Protection trip current - Number of reclosures - Protection status messages, etc. Unit with three contact output relays one switched and two simple relays, all programmable. The main relay provides the protection associated with the contact, one is for the prealarm and the other for locking once the maximum number of reclosures is reached. It includes a voltage-free input for external tripping and reclosing Fitting on DIN 46277 rail (EN-50022) Reduced three-module size Connection by pluggable terminals Aplicación WRU-10 MT relays associated with a motorized circuit breaker allow automatic reclosing after tripping, thus offering the most adequate solution for public lighting, ATM machines, refrigerating chambers, traffic lights, etc. Their design features guarantee maximum security and continuity of the electrical service, avoiding unwanted tripping. Protection Class Measurement PROGRAMMABLE sensitivity PROGRAMMABLE delay Test and Reset Associated circuit breaker Circuit breaker control Reclosure No. of reclosures Time between reclosures Reclosure counter reset time Relay signalling LED indicators / backlight DISPLAY Remote Control Earth leakage A superimmunized True root mean square (TRMS) 0.03 to 3 A, amplifiable to 30 A using SETUP Time defined: 0.02 to 1 s, amplifiable to 10 s using SETUP. Inverse curve: INStantaneous / SELective. (IEC 60947-2) Using buttons T & R Circuit breaker defining the number of poles and the I n Switched NO/NC contact relay Earth leakage and circuit breaker Programmable Power supply voltage Leakage trigger Prealarm Locking Protection settings Leakage current/ trip reading TEST statuses and external trip Sequences / Number of reclosures External TEST possible, tripping by voltage-free input Electrical features Auxiliary power supply 230 V ac (± 30%) 50 / 60 Hz Output contacts 250 V ac, 5 A / 230 V ac, 250 ma Operating temperature -20... + 70 ºC Mechanical features Attachment DIN rail 46722 (EN 50022) 3 modules Weight 275 g Protection degree IP 20, trans-cabinet IP 41 Standards IEC 60947-2, IEC 60755, IEC 62020, IEC 61008 P2-25

Overcurrent and earth leakage protection and self-reclosing Relé diferencial con toroidal integrado + magnetotérmico motorizado WRU-10 MT Earth leakage relay with built-in transformer and display (type A) 75 44 85 45 73 52,5 22,75 10 n28 27,25 References No. of reclosures Time between reclosures Net section (mm) I n (A) Delay Type Code Programmable Ǿ 28 0.03 to 3 A amplifiable to 30 A 0.02 to 1 s amplifiable to 10 s Inverse curve: INS/SEL WRU-10 MT P24275 Connections L1 L2 L3 N L1 L2 L3 N MT 2 N L 11 M O I 12 MT 2 1 2 N L 11 M O I 12 O e te s I R O e te R 1 3 4 5 6 1 3 4 5 6 Reset Reset Test Test WRU-10 MT MENU SETUP 23 9 10 11 1 WRU-10 MT MENU SETUP 23 9 10 11 1 TILI ION te Re e TILI ION te TRI Re e P2-26

Overcurrent and earth leakage protection and self-reclosing Earth leakage relay + circuit breaker + transformer RGU-10 MT Earth leakage Relay WG + MT Series Description Self-reclosing, electronic earth leakage protection relay Associated to an external toroidal transformer of the WG / WGS / WGC Series. It is connected to a motorized circuit breaker of the MT or similar series as the circuit breaker The self-reclosing earth leakage and/or overload trip is programmable Superimmunized Type A relay with high frequency current filtering and high immunity. Monitoring in true root mean square Backlight display Two independent outputs: trigger/reset relay and end-of-reclosing-sequence interlocking relay External input for remote control functions Automatic test of the connection and status of the external transformer with an inductive test Application The RGU-10 MT relays associated to the transformers of the WG Series allow an intelligent earth leakage protection. These are used jointly with an MT or similar circuit breaker to enable the self-reclosure after a trip (overload and earth leakage reclosing), offering a very good solution for public lighting, cash machines, refrigeration chambers, etc. Their design characteristics guarantee maximum security and continuity of the electrical service, avoiding unwanted tripping. Protection Class Measurement Sensitivity Delay Earth leakage transformer Test and Reset Associated circuit breaker I n and no. of poles Circuit breaker control Reclosure No. of reclosures Time between reclosures Partial counter reset time Relay signaling LED Display Remote signaling (outputs) Remote Control (inputs) Earth leakage and Circuit breaker A superimmunized True root mean square (TRMS) Programmable from 30 ma... 30 A Programmable from 20 ms... 10 s Inverse curve: instantaneous or selective External, WG / WGS / WGC With built-in button Motorized circuit breaker MT Series, MT-FDE Defined by the circuit breaker used Simple relay ON / OFF Earth leakage and Circuit breaker Programmable Programmable Programmable Presence of voltage Leak trip Reclosing activation Interlocking status LCD Lock status indicator relay ON / OFF Auxiliary power supply 230 Vac (± 20 %) 50 / 60 Hz Output contacts Current 5 Aac Operating temperature -10... +50 ºC Construction features Fixing DIN rail 3 modules Weight 236 g Degree of protection IP 20 Terminals, IP 41 back panel Standards IEC 61008-1, IEC 755, IEC 255-5 P2-27

ON / OFF externo External ON/OFF ON / OFF externo External ON/OFF Self-reclosing overload and earth leakage protection Overcurrent and earth leakage protection and self-reclosing Earth leakage relay + circuit breaker + transformer RGU-10 MT Earth leakage Relay WG / WGC + MT Series References Reclosing element Communications I n (A) Delay (s) (*) Type Code Circuit-breaker - 0,03... 30 0,02... 10 RGU-10 MT P24642 Circuit-breaker RS-485 0,03... 30 0,02... 10 RGU-10 C MT P24652 (*) The delay is cancelled in all relays with a sensitivity adjustment of 0.03 A. Connections RGU-10 MT / RGU-10C MT RGU-10 MT with coil / RGU-10C MT with coil L1 L2 L3 N SUPPLY A.C. 230 V L1 L2 L3 N SUPPLY A.C. 230 V 4 15 MT - C- 62/64 MT N L 11 M O I 12 10 11 12 13 14 15 MT - C- 62/64 MT C1 U> N M C2 O I 12 L 11 10 11 12 13 14 15 WG Type WG 1S11S2 1S2 1S1 Reset RGU-10 MT Test WG Type WG 1S11S2 1S2 1S1 Reset RGU-10 MT Test Disparo por MOTOR OFF Trip by OFF MOTOR. Disparo por BOBINA Trip by TRIP COIL. 7 8 9 CARGA LOAD SETTING SETUP TRIP: 1 2 3 4 5 6 7 8 9 CARGA LOAD SETTING SETUP TRIP: SEC.T: St (in case of shunt coil) Pt (in case of undervoltage coil) 1 2 3 4 5 6 7 8 9 SETTIN TRIP: P2-28

Overcurrent and earth leakage protection and self-reclosing Earth leakage relay + circuit breaker + transformer RGMT Earth leakage Relay WG + MT Series Description Self-reclosing electronic earth leakage protection relay, associated to an external toroidal transformer of the WG / WGS / WGC It is connected to a motorized circuit breaker of the MT or similar series as the overload protection or circuit breaker element. Type A relay with high frequency current filtering and high immunity. Monitoring in true root mean square (TRMS). The RGMT has the following functions: yearth leakage protection and self-reclosing yoverload reclosing. Display of: yrelay status ytotal reclosure no. meter Two remote control inputs: yremote trip/reset of the group yactivate/deactivate the overload reclosure process. Application The RGMT relays associated to WG, transformers, connected to an MT or similar circuit breaker guarantee the self-reclosing earth leakage and overload protection of a system after a trip, with both earth leakage and overload protection systems. It is the ideal solution for telephony installations, television repeaters, etc. Protection Class Measurement Sensitivity Delay Earth leakage transformer Test and Reset Associated circuit breaker I n, No. of poles, thermal curve and cut-out power Reclosure No. of reclosures Time between reclosures Partial counter reset time Safety interlocking Earth leakage and circuit breaker A superimmunized True root mean square (TRMS) 0.03 / 3 A Fixed 20 ms External, WG / WGS / WGC With built-in button Motorized circuit-breaker MT Defined by the circuit breaker used Earth leakage and circuit breaker 2 circuit breaker and 10 earth leakage 3 min 30 min In the circuit breaker. With disconnection lever Auxiliary power supply 230 Vac (± 20 %) 50 / 60 Hz Circuit breaker control contacts 250 Vac, 8 A Output contacts 250 Vac, 8 A Operating temperature -10... +50 ºC Construction features Fixing DIN rail 6 modules Weight 350 g Degree of protection Terminals: IP 20 Embedded: IP 41 Standards IEC 61008-1, IEC 755, IEC 255-5, IEC 947-2, IEC 60898 P2-29

Overcurrent and earth leakage protection and self-reclosing Earth leakage relay + circuit breaker + transformer RGMT Earth leakage Relay WG + MT Series References Useful diameter Ø mm Poles I n (A) No. of reclosures Control of the circuit breaker Delay (s) (*) Type Code In accordance with WG In accordance with MT 0,03 / 3 circuit breaker: 2 earth leakage: 10 Relay ON / OFF 02 RGMT P21130 (*) The delay is cancelled in all relays with a sensitivity adjustment of 0.03 A. Connections P2-30

Overcurrent and earth leakage protection and self-reclosing RECmax MP Motorized circuit breaker (up to 63 A) Description The RECmax MP series are motorized circuit breakers that can be linked remotely. They function as protection against shortcircuit and overload, and can also be used as a circuit breaker. After a disconnection caused by a circuit breaker, the switch can be reconnected through an external order. It has two inputs that act through voltage-free external signals, ordering the opening (input O) and subsequent closing (reclosing system) of the automatic switch (input I). It also has two singlecontacts outputs for signalling the status and the cause of the opening and closing of the automatic switch (trip, manual/test). Application The RECmax MP series are motorized circuit breakers that can be controlled remotely, apt for any application in which remote connection/disconnection control is required. Circuit-breaker Gauges I n (A) 6-10-16-20-25-32-40-50-63 Nominal cut-out power (IEC 947-2) 6 ka, in accordance with EN 60898 10 ka, in accordance with EN 60947-2 Typical curve Nominal working voltage Work frequency range C or D, depending on the type 240 / 415 Vac 50... 60 Hz Operating temperature -25... +55 ºC Storage temperature -55... +55 ºC Motor Nominal voltage 230 Vac, ± 10 % Opening impulse > 50 ms Closing impulse > 50 ms Construction features Fixing DIN rail 2 poles: 5.5 modules 4 poles: 7.5 modules Mechanical working life Weight > 20,000 operations 2 poles: 645 g 4 poles: 890 g Degree of protection IP 40 (DIN 40050) Standards IEC 947-2, IEC 60898 They are also used as circuit breakers linked to CIRCUTOR self-reclosing relays. They are an essential accessory for protection and automatic circuit breaker and earth leakage reclosing system P2-31

ac Self-reclosing overload and earth leakage protection Overcurrent and earth leakage protection and self-reclosing RECmax MP Motorized circuit breaker (up to 63 A) References 2 poles 4 poles C Curve D Curve C Curve D Curve I n (A) Type Code Type Code Type Code Type Code 6 RECmax MP-C2-6 P27110 RECmax MP-D2-6 P27130 RECmax MP-C4-6 P27120 RECmax MP-D4-6 P27140 10 RECmax MP-C2-10 P27111 RECmax MP-D2-10 P27131 RECmax MP-C4-10 P27121 RECmax MP-D4-10 P27141 16 RECmax MP-C2-16 P27112 RECmax MP-D2-16 P27132 RECmax MP-C4-16 P27122 RECmax MP-D4-16 P27142 20 RECmax MP-C2-20 P27113 RECmax MP-D2-20 P27133 RECmax MP-C4-20 P27123 RECmax MP-D4-20 P27143 25 RECmax MP-C2-25 P27114 RECmax MP-D2-25 P27134 RECmax MP-C4-25 P27124 RECmax MP-D4-25 P27144 32 RECmax MP-C2-32 P27115 RECmax MP-D2-32 P27135 RECmax MP-C4-32 P27125 RECmax MP-D4-32 P27145 40 RECmax MP-C2-40 P27116 RECmax MP-D2-40 P27136 RECmax MP-C4-40 P27126 RECmax MP-D4-40 P27146 50 RECmax MP-C2-50 P27117 RECmax MP-D2-50 P27137 RECmax MP-C4-50 P27127 RECmax MP-D4-50 P27147 63 RECmax MP-C2-63 P27118 RECmax MP-D2-63 P27138 RECmax MP-C4-63 P27128 RECmax MP-D4-63 P27148 86 45 90 110 90 110 35 45 79 115 50 33 83 Connections L1 L2 L3 N! 1 2 3 N L POWER 4 5 6 7 8 1 2 3 4 5 6 7 8 N L POWER 230 V 30% 50-60 Hz ; 5 VA 14 9 N L M Reset Test C MP ON TEST 15 10 ON / OFF TRIP O I EXTERNAL RECONNECTION EXTERNAL DISCONNECTION TRIP O C I ON/OFF 9 10 11 12 13 14 15 CONTACT NC 230 V ac ; 0,25 A TRIP M! O C I OFF CONTACT NO 230 V ac ; 0,25 A ON/OFF 9 10 11 12 13 14 15 P2-32

Overcurrent and earth leakage protection and self-reclosing MT Motorized circuit breaker (up to 63 A) Description The motorized circuit breakers of the MT Series can be associated remotely. They protect against short-circuits and overloads, but are also used as a circuit breaker. Includes auxiliary contacts to indicate the status of the circuit breaker. The switch can be connected again after a manual or circuit breaker disconnection with an electric order following the "DISCONNEC- TION (0) - CONNECTION (1)" sequence. Application The MT Series is composed of motorized circuit breakers that can be activated remotely and can be used in any application that uses a connection/disconnection remote control. They are also used as the circuit breakers associated to the self-reclosing relays. Circuit-breaker Gauges I n (A) 6-10-16-20-25-32-40-50-63 Nominal cut-out power (IEC 947-2) 6 ka, in accordance with EN 60898 10 ka, in accordance with EN 60947-2 Typical curve Nominal working voltage Work frequency range C or D, depending on the type 240 / 415 Vac 50... 60 Hz Operating temperature -25... +55 ºC Storage temperature -55... +55 ºC Motor Nominal voltage 230 Vac, ± 10 % Opening impulse > 50 ms Closing impulse > 50 ms Construction features Fixing DIN rail 2 poles: 5.5 modules 4 poles: 7.5 modules Mechanical working life Weight > 20,000 operations 2 poles: 645 g 4 poles: 890 g Degree of protection IP 40 (DIN 40050) Standards IEC 947-2, IEC 60898 They are a vital accessory in the self-reclosing overload and earth leakage protection process. P2-33

Overcurrent and earth leakage protection and self-reclosing MT Motorized circuit breaker (up to 63 A) 2 poles 4 poles References 2 poles 4 poles C Curve D Curve C Curve D Curve I n (A) Type Code Type Code Type Code Type Code 6 MT-C-E62-6A P20110 MT-D-E62-6A P20130 MT-C-E64-6A P20120 MT-D-E64-6A P20140 10 MT-C-E62-10A P20111 MT-D-E62-10A P20131 MT-C-E64-10A P20121 MT-D-E64-10A P20141 16 MT-C-E62-16A P20112 MT-D-E62-16A P20132 MT-C-E64-16A P20122 MT-D-E64-16A P20142 20 MT-C-E62-20A P20113 MT-D-E62-20A P20133 MT-C-E64-20A P20123 MT-D-E64-20A P20143 25 MT-C-E62-25A P20114 MT-D-E62-25A P20134 MT-C-E64-25A P20124 MT-D-E64-25A P20144 32 MT-C-E62-32A P20115 MT-D-E62-32A P20135 MT-C-E64-32A P20125 MT-D-E64-32A P20145 40 MT-C-E62-40A P20116 MT-D-E62-40A P20136 MT-C-E64-40A P20126 MT-D-E64-40A P20146 50 MT-C-E62-50A P20117 MT-D-E62-50A P20137 MT-C-E64-50A P20127 MT-D-E64-50A P20147 63 MT-C-E62-63A P20118 MT-D-E62-63A P20138 MT-C-E64-63A P20128 MT-D-E64-63A P20148 Accessory - Trip coil F6 P29101 Connections N L 2 4 12 14 22 24 N L External disconnection signal H H M 0 I 1 3 11 21 External connection signal N L LOAD P2-34

Overcurrent and earth leakage protection and self-reclosing MT-FDE Motorized circuit-breaker (from 63 A) Description Automatic switch with remote control of the MT-FDE Series, for currents of 80 to 250 A, 3 and 4 poles. Responsible for the protection against shortcircuits and overloads, but also used as a circuit breaker. The switch can be reclosed with two methods, depending on the adjustment of the motor group in the operations mode: MANU : executed manually with the same switch, following the OFF and ON sequence. AUTO : carried out with an electrical impulse, following the OFF and ON sequence. Application The MT-FDE Series is composed of motorized circuit breakers that can be activated remotely and can be used in any application that uses a connection/disconnection remote control. Circuit-breaker Gauges I n (A) No. of poles Nominal cut-out power (IEC 947-2) Typical curve Nominal working voltage Work frequency range MT-FDE: 80-100-125-160 MT-FEE: 250 3 or 4, depending on the type MT-FDE: 25 ka, in accordance with IEC 60947-2 MT-FEE: 36 ka C or D, depending on the type 240 / 415 Vac 50... 60 Hz Operating temperature -25... +55 ºC Storage temperature -55... +55 ºC Motor Nominal voltage Minimum voltage Activation impulse Deactivation impulse Construction features Fixing Weight 230 Vac 210 Vac 50 ms 50 ms Panel (base + plug-in socket) 3 poles: 81 x 130 x 185 mm 4 poles: 108 x 130 x 185 mm Depending on the type Degree of protection IP 40 (DIN 40050) Standards IEC 60947-2 They are also used as circuit breakers associated to the self-reclosing relays, for example, RGU-10 MT orrrm. They are a vital accessory in the self-reclosing overload and earth leakage protection process. P2-35

Overcurrent and earth leakage protection and self-reclosing MT-FDE Motorized circuit-breaker (from 63 A) 3 poles 4 poles References 3 poles 4 poles Type Weight (kg) Code Type Weight (kg) Code 80 MT-FDE-80A 2,9 P20D60 MT-FDE-80A 3,4 P20D70 100 MT-FDE-100A 2,9 P20D61 MT-FDE-100A 3,4 P20D71 125 MT-FDE-125A 2,9 P20D62 MT-FDE-125A 3,4 P20D72 160 MT-FDE-160A 2,9 P20D63 MT-FDE-160A 3,4 P20D73 250 MT-FEE-250A 3,8 P20D64 MT-FEE-250A 4,6 P20D74 Connections N L1L2L3 F1 1 3 5 7 12 On A2 Off A4 N N EC ED On MANUAL Off 2 4 6 8 11 1 A1 FDE N L1L2L3 LOAD P2-36

Overcurrent and earth leakage protection and self-reclosing WRGMT Complete overload and earth leakage protection and reclosure equipment Description The WRGMT group acts as an overload (overload + short-circuit) and earth leakage protection system with earth leakage and overload reclosure. WRGMT, 2 poles WRGMT, 4 poles The nominal current of the overload protection is determined by the type of MT (up to 63 A) or MT-FDE used. The group is composed of the following elements: RGMT relay (earth leakage protection) Motorized automatic switch of the MT- FDE Series or motorized circuit breaker of the MT Series, with overload protection and circuit breaker functions Earth leakage transformer, WG Application The WRGMT groups can be used to make safety compatible with the continuity of the service in remote installations or installations that do not have the usual maintenance staff. They guarantee the overload and earth leakage protection with a self-reclosing system after a trigger, both in the case of an earth leakage and overload trip. It is a very good solution in installations in special locations that are hard to monitor and guard: telephony installations, television repeaters, refrigeration chambers, etc. References 2 poles 4 poles I Dn (A) Type Code Type Code 6 WRGMT-C-2-6 A P21210 -- -- 10 WRGMT-C-2-10 A P21211 WRGMT-C-4-10 A P21221 16 WRGMT-C-2-16 A P21212 WRGMT-C-4-16 A P21222 20 WRGMT-C-2-20 A P21213 WRGMT-C-4-20 A P21223 25 WRGMT-C-2-25 A P21214 WRGMT-C-4-25 A P21224 32 WRGMT-C-2-32 A P21215 WRGMT-C-4-32 A P21225 40 WRGMT-C-2-40 A P21216 WRGMT-C-4-40 A P21226 50 WRGMT-C-2-50 A P21217 WRGMT-C-4-50 A P21227 63 WRGMT-C-2-63 A P21218 WRGMT-C-4-63 A P21228 Other currents, on demand P2-37

Overcurrent self-reclosing RECmax P Self-reclosing motorized circuit breaker (up to 63 A) Description The RECmax P series are 2- and 4-pole circuit breakers connected to a compact motor and internal control unit that enables automatic reclosing system. After triggering, the switch reconnects following a sequence of 3 reconnections, with 3 minutes between resets. If the unit is not able to reconnect after 3 attempts, it remains triggered until a manual or remote reset is made. They can also be connected remotely to an external control. It has two inputs that through voltage-free external signals, order the opening (input O) and subsequent closing (reclosing system) of the automatic switch (input I). They function as protection against shortcircuit and overload, and can also be used as a remote circuit breaker. The switch status is indicated by LED signals on the device s front panel. An green ON LED indicates that the device is in service; a red OFF LED indicates that the device is triggered. A TEST/RESET of the device can be performed by pressing a button to check the triggering and then reset the device. It also has two single-contact outputs for signalling the status and the cause of the opening and closing of the automatic switch (trigger, manual/test). Application Circuit-breaker Gauges I n (A) 6-10-16-20-25-32-40-50-63 Nominal cut-out power (IEC 947-2) 6 ka, in accordance with EN 60898 10 ka, in accordance with EN 60947-2 Typical curve Nominal working voltage Work frequency range C or D, depending on the type 240 / 415 Vac 50... 60 Hz Operating temperature -25... +55 ºC Storage temperature -55... +55 ºC Motor Nominal voltage 230 Vac, ± 10 % Opening impulse > 50 ms Closing impulse > 50 ms Construction features Fixing DIN rail 2 poles: 5.5 modules 4 poles: 7.5 modules Mechanical working life Weight > 20,000 operations 2 poles: 645 g 4 poles: 890 g Degree of protection IP 40 (DIN 40050) Standards IEC 947-2, IEC 60898 The RECmax MP series are motorized circuit breakers that can be reset automatically or controlled remotely, apt for any application in which remote connection/disconnection control is required. They are an essential accessory for protection and automatic circuit breaker and earth leakage reclosing system, and for external connection/disconnection control. P2-38

ac Self-reclosing overload and earth leakage protection Overcurrent self-reclosing RECmax P Self-reclosing motorized circuit breaker (up to 63 A) References 2 poles 4 poles C Curve D Curve C Curve D Curve I n (A) Type Code Type Code Type Code Type Code 6 RECmax P-C2-6 P28110 RECmax P-D2-6 P28130 RECmax P-C4-6 P28120 RECmax P-D4-6 P28140 10 RECmax P-C2-10 P28111 RECmax P-D2-10 P28131 RECmax P-C4-10 P28121 RECmax P-D4-10 P28141 16 RECmax P-C2-16 P28112 RECmax P-D2-16 P28132 RECmax P-C4-16 P28122 RECmax P-D4-16 P28142 20 RECmax P-C2-20 P28113 RECmax P-D2-20 P28133 RECmax P-C4-20 P28123 RECmax P-D4-20 P28143 25 RECmax P-C2-25 P28114 RECmax P-D2-25 P28134 RECmax P-C4-25 P28124 RECmax P-D4-25 P28144 32 RECmax P-C2-32 P28115 RECmax P-D2-32 P28135 RECmax P-C4-32 P28125 RECmax P-D4-32 P28145 40 RECmax P-C2-40 P28116 RECmax P-D2-40 P28136 RECmax P-C4-40 P28126 RECmax P-D4-40 P28146 50 RECmax P-C2-50 P28117 RECmax P-D2-50 P28137 RECmax P-C4-50 P28127 RECmax P-D4-50 P28147 63 RECmax P-C2-63 P28118 RECmax P-D2-63 P28138 RECmax P-C4-63 P28128 RECmax P-D4-63 P28148 86 45 90 110 90 110 35 45 79 115 50 33 83 Connections L1 L2 L3 N! 1 2 3 N L POWER 4 5 6 7 8 1 2 3 4 5 6 7 8 N L POWER 230 V 30% 50-60 Hz ; 5 VA 14 9 N L M Reset Test C MP ON TEST 15 10 ON / OFF TRIP O I EXTERNAL RECONNECTION EXTERNAL DISCONNECTION TRIP O C I ON/OFF 9 10 11 12 13 14 15 CONTACT NC 230 V ac ; 0,25 A TRIP M! O C I OFF CONTACT NO 230 V ac ; 0,25 A ON/OFF 9 10 11 12 13 14 15 P2-39

Overload reclosure and protection Overload + reclosing relay RRM Overload reclosing relay Description Self-reclosing electronic relay of motorized circuit breakers. The relays of the RRM series can be used to control, send remote signals and for the remote control of the associated motorized circuit breaker (MT or MT-FDE Series). The RRM relay has the following functions: Motorized circuit breaker control: yautomatic reclosing yremote connection/disconnection (nonreclosing) Signalling: ylocal, with LEDs yremote signalling with relay of the reclosing lock (in RRM-P) yrs-485 Communications (in RRM-C) Remote control of the automatic switch The complete reclosing group is composed of the following elements: Motorized circuit breaker of the MT or MT- FDE Series (2 or 4 poles) Control relay RRM. Application The RRM relays can be used in all applications that require a self-reclosing motorized circuit breaker after a trigger or with the use of remote control systems. It has been specially designed to work with the circuit breakers of the MT or MT-FDE Series. Protection Associated circuit breaker I n, No. of poles, thermal curve and cut-out power Circuit breaker control Reclosure No. of reclosures Time between reclosures Partial counter reset time Safety interlocking Relay signaling LED Remote signaling (outputs) Remote Control (inputs) Circuit breaker Motorized circuit breaker MT or MT-FDE Defined by the circuit breaker used Motor control contactor Circuit breaker Programmable: 0, 1, 2, 4, 6, 8 times Programmable: 0.5, 1, 2, 3, 4, 5 min 30 min In the circuit breaker. With disconnection lever Presence of voltage and no circuit breaker trigger Trigger set off by external order Interlocking after the end of reclosures Reclosing RRM-P: Interlocking relay RRM-C: RS-485 Communications ON/OFF Potential free input of the circuit breaker (non-reclosing external OFF) Auxiliary power supply 230 Vac (± 20 %) 50 / 60 Hz Output contacts 250 Vac, 1 A Operating temperature -10... +50 ºC Construction features Fixing DIN rail 1 modules Weight 88 g Degree of protection IP 20 Terminals, IP 41 back panel Standards IEC 947-2 P2-40