TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

Similar documents
TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

TPHK Series Immersible Pump

TPAK Series COOLANT PUMP

Walrus Pump Co., Ltd.

TPHK Series Immersible Pump

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

Duplex Booster System Instruction Manual

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Installation and Operating Instructions for Davey HS20-65Y2 Multistage Pump

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

6. Electrical. 7. Settings. 8. Quick

SHALLOW WELL JET PUMP

TW1000E-20W-70-DCA In Enclosure w/ Double Check Assembly VARIABLE SPEED BOOSTER SYSTEM

SUBMERSIBLE SUMP PUMPS

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

STAR STOP SHALLOW WELL JET PUMP

SUBMERSIBLE SUMP PUMPS

HALLMARK INDUSTRIES INC

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

ESE Series Cast Iron Sewage Pumps

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

TW G-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

Unilift KP 150, KP 250, KP 350

GARDEN HOSE UTILITY PUMP

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

Matala. VersiFlow Series. Instruction and Maintenance Manual

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

AUTOMATIC SUBMERSIBLE UTILITY PUMP

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

StormPro BA Series Sump Pump

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SUNC3000 / Item #40885

Installation Manual DIAPHRAGM WELL TANK

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

StormPro BCV400 Sewage Ejector Pump

OWNER S MANUAL Spa & Jetted Bathtub Pump

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

HUNTER PUMPS ELECTRIC FIRE PUMP SET

Owner s Manual & Safety Instructions

SELF PRIMING CHEMICAL SERVICE PUMPS

Grundfos.bk Page 1 Thursday, June 11, :59 PM GRUNDFOS INSTRUCTIONS. CRN MAGdrive. Installation and operating instructions

Domestic Water Supply Pressure Pumps

Installation & Operating Manual

Installation Instructions Receiver Rack (Part # 7700) Universal Application

Submersible Tank Pump

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

6L Oil-less Air Compressor 53103

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

GeyserMax-Flow Series

PRE-PLUMBED SEWAGE SYSTEM

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

MODEL 900 IMPELLER-TYPE FLOW METER

ADI-125/750 ADI-125/1500 ADI-125/2500

READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

OWNERS MANUAL ECODIVER

NECO Pumping Systems

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

H.S. MACHINERY RING COMPRESSORS

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Operations Manual. and. Seal Kit Replacement Guide

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

OPERATING SERVICE MAINTENANCE MANUAL

Operators Manual. Recirculating Chiller /06/08

OWNERS MANUAL JANUARY 2007 ISO

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Installation and Operating Instructions for Davey HS20-65Y2T Multistage Pressure System with

OWNERS MANUAL JANUARY 2007 ISO

SUBMERSIBLE PUMP HSE RANGE

Operating Instructions for PAC800 Battery Charger

A Series. 50 Hz. Horizontal Multistage Centrifugal Pumps AHC/AHI, AHBI/AHBS ISO Vol. PIAH-18091

DC to AC Power Inverters

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

DC to AC Power Inverters

Air Compressor. Owner s Manual

QUALITY MISTING PUMPS

ProFlo FatBoy

Owner s Manual Drill and Light Weight Portable Utility Pumps

Self-Priming Centrifugal Pumps

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Transcription:

TPH Series MULTISTAGE CENTRIFUGAL PUMP Instruction Manual NSF/ANSI 372 ISO 9001 Certified WALRUS PUMP CO., LTD.

EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.8314, Dapiantou, Sanzhi Dist., New Taipei City 252, Taiwan Declare that the machinery described: Name : Water Pump Model : TPH Series Conform to the following directive: 2006/42/EC Machinery directive 2014/35/EU Low voltage directive 2014/30/EU EMC (Electromagnetic compatibility) directive Refer to the following standards: EN ISO 12100:2010 EN ISO 13857:2008 EN 809:1998+A1:2009 EN 602041:2006 EN 603351:2012 EN 60335241:2003 EN 6100062:2005 EN 6100063:2007 R&D department manager: Kao Tienchuan Manager: ~ 2 ~

TPH Instruction Manual Please study all instructions carefully before installing your new system, as failures caused by incorrect installation and operation are not covered by the warranty. 1. General Data: 1.1 Applications The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. It works for clean or other liquids without abrasive matters. Industrial circulation system Washing/cleaning system Pressure boosting system Water/liquid transfer Agricultural irrigation Airconditioning 1.2 Pump Construction: Horizontal multistage centrifugal pump, non selfpriming, coaxial pump/motor design, impellers mounted on extended motor shaft. All parts in contact with the pumped liquid are made of stainless steel. 1.3 Operation conditions: 1. Ambient temperature: Max. 40 C 2. Liquid temperature range: 0 C to 90 C 3. Operating pressure: Max. 10 kg/cm² 4. Inlet pressure: Max. 6 kg/cm² 5. Head: 50Hz : Up to 70M 60Hz : Up to 80M 1.4 Applications TPH pumps are horizontal, multistage centrifugal pumps for the pumping of clean, thin and nonexplosive liquids, not containing solid particles or fibres that may attack the pump mechanically or chemically. The pump must not be used for the transfer of flammable or toxic liquids. 2. Installation and piping 2.1 Installation site 2.1.1 For secure operation, please mount and bolt the pump base to the foundation. 2.1.2 Select a dry and good ventilated site and provide accessible space around the pump for future maintenance and service. 2.1.3 Make sure the ambient temperature is below 40 C(104 F) and the flowing liquid temperature does not exceed 90 C(194 F). 2.1.4 Do not operate the pump under explosive environment. 2.1.5 Horizontal installation is recommended. When it is installed in other positions, please ~ 3 ~ provide drain holes to allow drainage of the pump. 2.1.6 Indoor: TO avoid your furniture damage, do not install the pump on ceiling, carpet or any place close to electrical appliance, and also must provide drain hole. 2.1.7 Outdoor: When the pump is installed outside, please provide a suitable cover to protect it from weather and frost. Please do not allow any foreign objects fall into the motor fan cover. 2.2 Electrical connection 2.2.1 This mark located outside the connection box is a warning for an electrical hazard. 2.2.2 The electrical connection should be carried out in accordance with local regulations. The operating voltage and frequency are marked on the nameplate. Please make sure that these data match with your job requirement. For your safety, be sure the Residual current device (RCD, 30mA) is in your system and grounding is properly connected to prevent from electric shock. 2.2.3 Motors must be connected to a motorprotective circuit breaker which can be manually reset. Set the motorprotective circuit breaker according to the rated current of the motor. See nameplate. 2.2.4 Three phase motors must be connected to a motor starter for protection of overload and single phase running. Please be sure if the direction of rotation is correct. For three phase motor you can reverse the direction of rotation by interchanging any two of the incoming supply wires. Before your first operation, please place a allen wrench against the shaft at motor end and turn by the direction of rotation to see if rotor spins freely. 2.2.5 The position of the connection box is adjustable. It can be turned either side before the pump is installed. The preset position from the factory is on the top of the motor. To change the position of the connection box, please remove the bolts on the motor frame (4 bolts which are bolted into the chamber) and turn the stator housing to the required position. Replace the screws and tighten securely. Fig.1

2.3 The pump should be installed so that the suction pipe is as short and the suction lift as small as possible. 2.4 When draw liquid from the same level of the pump suction inlet, please allow a downward slope from the liquid source to the pump suction inlet to avoid air sucked in. If it is to pump liquid from a level lower than the pump suction inlet, a foot valve must be fitted to the end of the suction pipe. 2.5 Please select the pipe size specified in the specifications. Smaller piping will cause considerable pressure loss and affect pump efficiency. 2.6 All piping joints must be completely tight. Leakage in suction piping may result in the loss of the suction capability. Leakage in discharge piping may cause the "cycling" of the pump. 2.7 Please do not allow any foreign objects (chewing gum, dirt, and sand etc.) fall into the pump or motor. 2.8 The pump lifting capacity is related to the temperature of flowing liquid. Under normal flowing temperature (20 C 30 C), it will lift up to 5M. At high temperature operation (over 60 C), the pump must be installed at the level lower than the liquid source or the pump inlet pressure must be higher than 1 atmosphere (15 PSI). 2.9 It is extremely dangerous to run the pump against a closed discharge valve, because it will cause extremely high liquid flow temperature and damage your pump. You may connect a bypass/a drain to the discharge pipe to allow a minimum liquid flow through the pump. 2.10 Metal piping is recommended when the operations require high lifting head or high liquid temperature. 2.11 In systems with hot liquids (over 60 C), extra caution should be exercised to prevent from personal injury caused by escaping water. 3. Operation instructions 3.1 Priming Do not start the pump until it has been primed. Follow the following priming instruction: 3.1.1 Booster systems and systems where the liquid level on the suction side is above the pump inlet: 3.1.1.1 Close the isolating valves either side of the pump. 3.1.1.2 Remove the priming plug, fig. 2. ~ 4 ~ 3.1.1.3 Slowly open the suction valve and keep it open until a steady stream of liquid runs out the priming port. 3.1.1.4 Replace the priming plug and tighten it. 3.1.2 Pumping from tanks and wells where the liquid level on the suction side is below the pump inlet: 3.1.2.1 Close the discharge isolating valve. 3.1.2.2 Remove the priming plug, fig. 3. Priming plug Priming plug Fig.2 Fig.3 3.1.2.3 Pour water through the priming port. Make sure that the suction pipe and pump are completely filled with liquid and vented. 3.1.2.4 Replace the priming plug and tighten it. 3.2 Start the pump and slowly open the discharge valve until it is fully open. 3.3 If there is no discharge flow after a few minutes, please turn off the pump and repeat the Process of 3.1 Turn the pump on and off several times until it is working normally. 3.4 When pump is working on normal condition, measure the motor current and check it with the nameplate value. If it exceeds the rated value, please reduce the lifting capacity or fully open the valve. 3.5 When pump is not in use for a period, it should be drained by removing the priming and drain plugs. For start up after long time inactivity, please check if the impeller and mechanical seal are free. If they are locked up by sand, rust or something else please clean them up. Priming plug Drain plug Fig.4

4. Noise level Model LA 50Hz db(a) 60Hz Model LA 50Hz db(a) 60Hz Model LA 50Hz db(a) 60Hz TPH 2T2K TPH8T2K TPH25T2KF 76 TPH2T3K TPH8T2.5K TPH25T3KF 76 TPH2T4K TPH8T3K TPH25T4KF 76 TPH2T5K TPH8T4K 71 TPH25T5KF 76 TPH2T6K TPH8T5K 71 TPH25T6KF TPH8T6K TPH4T2K TPH4T3K TPH4T4K TPH12T1K TPH12T2K TPH12T3K 72 TPH50T2KF TPH50T2.5KF TPH50T3KF TPH4T5K TPH4T6K TPH12T4K TPH12T5K 71 77 TPH50T4KF TPH50T5KF TPH12T6K 71 The uncertainty is 4dB(A). 5. Maintenance 5.1. Lubrication The mechanical seal and shaft sleeves are lubricated by the pumped liquid. 5.2. Periodic checks The following checks should be carried out periodically to ensure the normal operation. 5.2.1. Check the quantity of liquid and operating pressure. 5.2.2. Check there are no leaks on piping joints. 5.2.3. Check the tripping of the motor starter. 5.2.4. Check that all controls are functioned normally. 5.3. The pump must not be used to transfer explosive liquids. In systems with hot liquids (over 60 C), extra caution should be exercised to prevent from personal injury. 5.4. The pump should not be used to transfer toxic or contaminated liquids. Please carefully follow all instructions in the manual as Walrus may refuse to accept the contaminated pump for servicing. 5.5. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent. 6. Wiring diagram 6.1 Single Phase ( 230V ) U1 230V V1 6.2 Single Phase (115/230V ) W2 U2 U1 V1 115V 6.3 9 Wire, 3 Phase U2 V2 W2 U5 V5 W5 U1 V1 W1 Low Voltage 6.4 12 Wire, 3 Phase W6 W2 U5 U6 U2 V5 V6 V2 W5 W2 U1 230V U2 V1 U2 V2 W2 U5 V5 W5 U1 V1 W1 High Voltage W5 U5 V5 W2 U2 V2 W6 U6 V6 U1 V1 W1 U1 V1 W1 ~ 5 ~ Low Voltage High Voltage

7. Fault finding (Make sure to disconnect the power before attempting to diagnose any fault.) Fault Cause 1. Check if electrical power source, fuse or circuit breaker failed. 1. Pump does not start 2. Check if pump is locked up by sand, rust or any foreign objects. 3. Check if the motor is defective due to overload or other causes. 1. If it is a three phase motor, please check if the direction of rotation is correct. 2. Pump runs at reduced capacity or no discharge water 2. Check if the inlet source is sufficient, the suction lift is not too great and the temperature is within the normal range. 3. Check if there is any leakage in suction pipe, check valve works normal and mechanical seal is not defective etc. 3. Pump stops during operation 1. Motor overheat due to excessive suction lift or too high liquid temperature. 2. Control circuit has cut out (pressure switch or level controller). 8. Dimensions (mm) TPH 2/4 Outlet Rp 1" D PS 3/8" 142 2T: Rp 1" Inlet 4T: Rp 1¼" 162 90 226 202 (1Ø) (3Ø) TPH 2T 138 160 A TPH 2T 1K 305 63 74 99 TPH 2T 2K 305 63 74 99 TPH 2T 3K 323 81 92 117 TPH 2T 4K 341 99 110 135 TPH 2T 5K 399 117 128 153 TPH 2T 6K 417 135 146 171 C B PS 3/8" ~ 6 ~ TPH 4T 4Ø8.5 108 130 TPH 4T 2K 315 73 84 109 TPH 4T 3K 381 99 110 135 TPH 4T 4K 408 126 137 162 TPH 4T 5K 435 153 164 189 TPH 4T 6K 493 181 192 217

TPH 8/12 Outlet Rp 1½" ( Or Rp 2 ") D PS 3/8" 182 Inlet Rp 1½" ( Or Rp 2 ") 189 111 241 TPH 8T 138 160 A TPH 8T 2 K 375 77 88 75 TPH 8T 2.5K 407 109 120 107 TPH 8T 3 K 407 109 120 107 TPH 8T 4 K 435 109 120 107 TPH 8T 5 K 473 143 154 141 TPH 8T 6 K 473 143 154 141 C B PS 3/8" TPH 12T 4Ø8.5 108 130 TPH 12T 1K 335 77 88 75 TPH 12T 2K 375 77 88 75 TPH 12T 3K 435 109 120 107 TPH 12T 4K 435 109 120 107 TPH 12T 5K 473 143 154 141 TPH 12T 6K 473 143 154 141 TPH 25T Outlet Rp 3" D 245 PT ½" Inlet Rp 3" 320 TPH 25T 50Hz TPH 25T 2KF 596 216.5 256.5 180 TPH 25T 3KF 656 276.5 316.5 240 TPH 25T 4KF 656 276.5 316.5 240 TPH 25T 5KF 766 336.5 376.5 300 PT ½" 200 C 4Ø12 168 280 B 190 A TPH 25T 60Hz 147 TPH 25T 2KF 536 156.5 196.5 120 TPH 25T 3KF 596 216.5 256.5 180 TPH 25T 4KF 596 216.5 256.5 180 TPH 25T 5KF 706 276.5 316.5 240 TPH 25T 6KF 706 276.5 316.5 240 TPH 50T Outlet Rp 4" D 245 PT ½" Inlet Rp 4" 325 147 200 280 A C B PT ¼" 4Ø12 168 190 TPH 50T 50Hz TPH 50T 2KF 642.5 263 303 222 TPH 50T 3KF 752.5 323 363 282 TPH 50T 4KF 802.5 323 363 282 ~ 7 ~ TPH 50T 60Hz TPH 50T2.5KF 582.5 203 243 162 TPH 50T 4KF 692.5 263 303 222 TPH 50T 5KF 742.5 263 303 222

Limited Warranty Products manufactured by Walrus Pumps Co (Walrus) are warranted to the first user only to be free of defects in material and workmanship for a period of 12 months from date of installation, but no more than 24 months from date of shipment. Walrus' liability under this warranty shall be limited to repairing or replacing at our election, without charge, FOB Walrus' distribution center or authorized service agent. Walrus will not be liable for any cost of removal, installation, transportation or any other charges that may arise in connection with warranty claim. The warranty period commences on the date of original purchase of the equipment. Proof of purchase and installation date, failure date, and supporting installation data must be provided when claiming repairs under warranty. This warranty is subject to due compliance by the original purchaser with all directions and conditions set out in the installation and operating instructions. Failure to comply with these instructions, damage or breakdown caused by fair wear and tear, negligence, misuse, incorrect installation, inappropriate chemicals or additives in the water, inadequate protection against freezing, rain or other adverse weather conditions, corrosive or abrasive water, lightning or high voltage spikes or through unauthorized persons attempting repairs are not covered under warranty. Walrus will not be liable for any incidental or consequential damages, losses, or expenses, arising from installation, use, or any other causes. There are no express or implied warranties, including merchantability or fitness for a particular purpose, which extend beyond those warranties described or referred to above. Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of limitations on the duration of an implied warranty, therefore, the limitations or exclusions herein may not apply. This warranty sets forth specific legal rights and obligations, however, additional rights may exist, which may vary from state to state. Supersedes all previous publications WALRUS PUMP CO., LTD. Web: w ww.walru spump.com CC70D0001D600EW0R03