OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

Similar documents
OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

SAE Engine Mount. Selection For Pumping Application. Matching Pump End To Engine. Type B Centrifugal Pumps Close coupled pump ends.

ESE Series Cast Iron Sewage Pumps

Model B1-1/2XQBS-11. Model B1-1/2XQBS-18. Model B1-1/2XQBS-26

Heater Manifold REPLACEMENT INSTRUCTIONS. Sta-Rite Pool/Spa Group. 293 Wright Street, Delavan, WI 53115

HALLMARK INDUSTRIES INC

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Self-Priming Centrifugal Pumps

OWNER S MANUAL CP, CB SERIES CENTRIFUGAL PUMP

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

Installation Manual DIAPHRAGM WELL TANK

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

SHEF30 Submersible Sump/ Effluent Pump

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

SP40 Submersible Sewage Ejector Pump

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

6 and 8 HAIR AND LINT STRAINERS

SUBMERSIBLE SWIMMING POOL DRAINER

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

MetroPrime 22MPC Self-Priming Centrifugal Pump

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS

Heavy Duty Engine Cranes

Operating Instructions & Parts Manual. Air/Manual Hydraulic Bottle Jacks

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

2 Speed Hydraulic Hand Pump

Telescopic Transmission Jacks

Hydraulic Transmission Jack, Telescopic

Air Actuated Hydraulic Bottle Jacks

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

MULTIPOSITION AIR CYLINDER

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

26-GALLON AIR COMPRESSOR Owner s Manual

PRE-PLUMBED SEWAGE SYSTEM

Pro Shot Grease Dispense Valve

SPECIFICATIONS CONTENTS:

INSTALLATION AND SERVICE MANUAL

MODEL G300 BRAKE BLEEDER

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps

Hydraulic Clutch Jack

Stainless Steel Air Motor Conversion Kits

Hydraulic Transmission Jacks

Long Chassis Hydraulic Service Jacks

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Heavy Duty Jack Stands

Merkur Displacement Pump

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SPECIFICATIONS CONTENTS:

DeZURIK KUL KNIFE GATE VALVES

Stainless Steel Air Motor Conversion Kits

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Service Jacks Operating Instructions & Parts Manual

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

POWER GEAR SLIDE-OUT MANUAL

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

Long Chassis Hydraulic Service Jacks

NECO Pumping Systems

Air Operated End Lift

HSIV PLOW OPERATOR S MANUAL

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

Operating Instructions & Parts Manual. Capacity 2 Ton 3 Ton

StormPro BA Series Sump Pump

Air Actuated Hydraulic Bottle Jack on Wheels

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Customer Support

GARDEN HOSE UTILITY PUMP

SKID STEER COMBO PLOW

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

3/4 Ton Heavy Duty Wheel Dolly

MODEL G300 Brake Bleeder

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

PARTS AND INSTALLATION MANUAL

Universal Hand Pump. Instructions D EN. - For transferring grease to Grease Jockey and G3 Systems - Part No Hand Operated - 35# Pump

SUBMERSIBLE SUMP PUMPS

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

ASSEMBLY / OPERATION INSTRUCTIONS. Low Profile Motorcycle Dolly

Colt Series C400, C500

Safety Sentry Electronic Breakaway Switch

MODEL 1385 & 1385-H Professional Rotary Drum Pump

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only.

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

DP DIAPHRAGM PUMP Parts & Instruction Manual

Strut Spring Compressor

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Operating Instructions & Parts Manual

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

Hydraulic Truck Jack

Transcription:

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST Centrifugal Pump Primer 383 0893 MODEL 6D, HAN-DEE PRIMER IMPORTANT For best possible performance continuous, satisfactory operation, read these instructions before installing your new pump primer. Should service be required, this manual can be a valuable guide, it should be kept near the installation for ready reference. Berkeley Pumps / 293 Wright Street / Delavan, WI 53115 PRINTED IN U.S.A. F000653 (Rev. 10/21/93)

The 6D "Han-Dee primer is a positive displacement air pump designed specifically for priming centrifugal pumps. Material Body-Aluminum Alloy Diaphragm-Molded synthetic rubber Performance Suction Pipe Size Primer 2-1/2 3 4 5 6 8 10 Model Strokes per Foot of Suction Pipe 6D 1 2 3 4 6 10 17 Check valve FIGURE 2 Remove Spring Ball and Rod Assembly 391 0893 Installation Install the Han-Dee primer on the suction or discharge of any style centrifugal pump. A discharge priming valve or similar air tight valve must be used on the pump discharge to prevent air from being drawn into the pump from the discharge while priming. Primer location: There are several tapped holes in the pump case that can be used for priming. Choose one that is at or above the centerline of the impeller eye, which is the minimum level of water required for proper start-up of a centrifugal pump. (Refer to Figure 1). Notice: Possible damage to primer diaphragm. Install globe valve or equivalent between the primer and pump case when primer is connected to the discharge and pressure developed by the pump exceeds 75 PSI. Refer to Figure 1. Han-Dee Primer 3. Primer is shipped with handle off. Attach handle to primer using the clevis and cotter pins provided. This is best achieved after primer mounting is complete. Refer to parts drawing for proper connection. Mounting Pump installation will determine the most convenient primer mounting location and fittings required. A. Mount directly on pump case using standard pipe fittings. A bracket (not furnished) may be needed to support the primer and prevent damage to piping when operating primer. Refer to Figure 7 on page 4 for primer mounting dimensions. Figures 3A and 3B show typical primer installations using standard pipe fittings. DO NOT USE THE BOTTOM FITTING ON THE PRIMER FOR SUPPORT Mounting Bracket Discharge Priming Valve Globe Isolation Valve Impeller Centerline FIGURE 3A 390 0893 Mounting Bracket FIGURE 1 386 0893 Special Instructions 1. Inlet on Model 6D primer has a spring loaded check valve for use when installed on pump suctions. When installing primer on the discharge or pressure side of pump, remove spring from the valve assembly as shown in Figure 2. 2. Reinstall check valve (inlet fitting) along with rod and ball assembly. Page 2 FIGURE 3B 392 0893 BE977

B. Use remote mounting kit, part number B50001 when installing Han-Dee primer on PTO driven pumps or wherever rigid installation is not convenient. Model 6D primer is tapped 1/2" NPT to receive this kit. 1. Assemble remote mounting kit components (see Figure 4). Make sure all connections are tight. Use pipe joint compound sparingly on metal to metal thread connections. 2. Attach remote mounting kit to pump and primer as shown in Figure 5. Notice: Possible damage to primer diaphragm. Install globe valve or equivalent between the primer and the pump case when primer is connected to the discharge and pressure developed by the pump exceeds 75 PSI. 3. Attach primer to trailer or remote bracket using hardware provided in kit. Refer to Figure 5. (2) Hose Clamp FIGURE 4 Hose (2) 1/2" x 3" T.O.E. Pipe Nipple Kit as furnished 1/2" x 2-1/2" Pipe Nipple 1/2" 90 Elbow 90 Street Elbow 1/2" Globe Valve (Not furnished) Additional 1/2" Pipe Nipple (Not furnished) Kit used with shut-off valve 388 0893 Operation The centrifugal pump case must be filled with water to the level described in the Installation section of this manual before it will start pumping. Notice: Pump must be primed before start-up. Do not run dry. As the Han-Dee primer evacuates air from the pump case, atmospheric pressure forces water up through the suction pipe and into the pump case. Any air leaking into the pump will increase the effort and time required to prime the pump. Inspect the suction piping, discharge valve, packing gland, and any drains or vent valves in the pump case to be sure that no air leaks exist. Proceed as follows: 1. Close pump discharge valve tightly. 2. Open shut-off valve (if used) in primer piping. 3. Work handle of Han-Dee primer up and down. Refer to performance chart at the top of page 2 to determine the approximate number of strokes required for your installation. To maximize primer performance, work handle at the start and finish of priming cycle as shown in Figures 6A and 6B, Page 4. Notice: If the Han-Dee primer is installed using a shut-off valve, do not attempt to work handle with this valve closed. Damage to diaphragm may result. FIGURE 5 Pickup photographs for these two figures Typical of PTO mount to pump suction. Typical of PTO mount to side of volute case. BE653 Page 3

Full Stroke 385 0893 7/16" DIA FIGURE 6A Start of priming cycle, pumping air only 3.50" 1/2" NPT FEMALE 389 0893 FIGURE 7 Primer mounting dimensions 387 0893 4-5" Stroke FIGURE 6B Finish of priming cycle, pumping air/water mixture 4. When water flows freely from opening in top of primer, pump should be primed. 5. Close shut-off valve (if used). 6. Start pump and open discharge valve slowly to allow any air remaining in the pump case to escape. 7. If unit fails to prime, refer to trouble shooting guide at right. Trouble - Cause and Remedy Water continues to flow from pump into primer after priming is complete: Primer check valve did not close. To close, bring primer handle to mid-stroke. Give sharp downward stroke. Pump fails to prime: Air leak. Check all primer connections. Check all pump suction connections. Check all pump discharge connections. Insufficient water level in pump case. Check primer connection to pump case. Piping must be at or above centerline of impeller eye. Pump loses initial prime: Air trapped in suction piping. Check for high spots in suction line, refer to centrifugal pump owner s manual for recommended/not recommended suction connections. Air leaking through packing. Check packing lantern ring for sufficient grease to prevent air from being drawn in during pressure drop. Page 4 BE977

EXPLODED VIEW 1 2 12 3 13 8 4 9 10 5 11 6 Check Valve 7 14 384 0893 REPAIR PARTS LIST Key Part Description Qty. Part No. 1 Handle 1 L01221 2 Diaphragm rod 1 S08561 3 Upper Housing 1 M03258 4 Diaphragm retainer plate-top 1 S08816 5 Diaphragm 1 S05467 6 Diaphragm retainer plate-bottom 1 S05470 7 Lower housing 1 M03259 8 Spring-check valve 1 S10893 9 Rod and ball assembly 1 S08789 10 Check valve seat 1 S08788 11 Guide-check valve 1 S08813 12 Clevis Pin 3/8" 2 S28333 Cotter Pin 2 S14923 13 Capscrew 3/8-16 4 S24893 14 Hex Nut 3/8-16 4 S26456 Not shown. BE653 Page 5

BERKELEY LIMITED WARRANTY Berkeley/Wicor Canada, Inc. ( Wicor ) warrants to the original consumer purchaser ( Purchaser ) of its products that they are free from defects in material or workmanship. If within twelve (12) months from the date of installation or twenty-four (24) months from the date of manufacture any such product shall prove to be defective, it shall be repaired or replaced at Berkeley s/wicor s option, subject to the terms and conditions set forth below. General Terms and Conditions Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty shall not apply to products which, in the sole judgement of Berkeley/Wicor, have been subject to negligence, abuse, accident, misapplication, tampering, alteration; nor due to improper installation, operation, maintenance or storage; nor to other than normal application, use or service, including but not limited to, operational failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums. Requests for service under this warranty shall be made by contacting the installing Berkeley/Wicor dealer as soon as possible after the discovery of any alleged defect. Berkeley/Wicor will subsequently take corrective action as promptly as reasonably possible. No requests for service under this warranty will be accepted if received more than 30 days after the term of the warranty. The warranty on all three phase submersible motors is void if three-leg overload protection of recommended size is not used. This warranty sets forth Berkeley s/wicor s sole obligation and purchaser s exclusive remedy for defective products. BERKELEY/WICOR SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. In the U.S.: Berkeley, 293 Wright St., Delavan, WI 53115 In Canada: Wicor Canada, Inc., 4544 Fieldgate Parkway, Mississauga, Ontario L4W 3W6 Wicor Canada, Inc., 200-E, Rue St-Louis, St-Jean-Sur-Richelieu, Québec J3B 1Y1 Page 6 BE977