PRIMADET non-electric delay detonators Dual StoperTM

Similar documents
PRIMADET non-electric delay detonators MS Primadet - millisecond series

SafeStart hand held SafeStart Initiators (SI-1)

SHORT DELAY NON-ELECTRIC DETONATORS

NONEL EZ DET. Properties. Technical Information. Nonelectric Blast Initiation System. Your Partner with TOTAL BLASTING SOLUTION

A NEW INITIATION SYSTEM THAT REMOVES THE OUTSIDE OR SURFACE DETONATORS FROM THE UNDERGROUND FACE. M Davis and J Fenwick Master Blaster

Royex Gen II Rock breaking cartridge Technical data sheet

ORICA NEW ZEALAND WESTPORT - PRICE LIST

Kompensator External Low Voltage Heating Cable System

OPERATIONS MANUAL LEVER CHAIN HOIST

5.1. EXPLOSIVE TYPES..Elimination of nitroglycerin effects.

P O B J E D A-RUDET. BIHNEL 0 ms 4 m

INITIATING SYSTEMS ACCESSORIES RANGE

Orica New Zealand National Price List. Dunedin Mining Services

Lab Session #1 Initiation Systems and Types of Explosives

Instructional Objectives. Science of blasting. Blasting Objectives. Black Powder. Explosive materials. GE 5471 ROCK ENGINEERING CH 13 Blasting

STANDARD OPERATING PROCEDURE. Standard Operating Procedure No: SOP-001 Version Number: 1.1. Vari-Stem blast hole stemming plug

Fuel Meter. Instructions - Parts List. Contents B. Model , measures in gallons Model , measures in liters. For metering fuels.

E*Star Seismic Detonators. Electronic Programmable Detonators.

OZM-72 anti-personnel fragmentation mine Compiled by Vanja Jokic using original Russian military sources, 2011

Tips & Technology For Bosch business partners

Tapecoat. Application Guideline

Blizzard, PO Box , Milwaukee, WI UNDERCARRIAGE KIT. Ford Super Duty F-250/350/450/

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

3M Electrical Tapes Product Selection Guide. Insulate & Protect. with Quality Tapes. Preliminary

FOSC-100 B/H FOSC-100 B2/H

Installation and Operation Guide

OPERATING MANUAL 18V Ni-Cd Battery Pack

Loose Parts Note: Determine the left and right sides of the machine from the normal operating position.

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

Users Manual. Phase Rotation Indicator

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

EC DECLARATION OF CONFORMITY

Model 1000 Low Profile Tailgate Spreader Receiver Mount

RECHARGEABLE 24 LED WORK LIGHT

RIGID ENTRY BOOT INSTALLATION GUIDE

Heat-Shrinkable Tubing

VP Remote User s Manual (nvp)

ADJUSTABLE ROTARY SCRAPER TOOL SCR USER S GUIDE

A Dyno Nobel Overview. Our Company Our Products Our Technology Our Services Your Benefit

EX Series User Manual

DynaCon Instruction Manual

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Pressurized oil drain for collection of used lubricants and anti-freeze.

3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project

Pyrohalon. Cables, halogen-free, fire-retardant. Pyrohalon PLUS Fire-resistant cables, halogen-free, fire-retardant

Low Profile Tailgate Spreaders SWING AWAY Mount

Owner s Manual & Safety Instructions

Installation and Operation Guide

Blasting in Underground Coal Mines. ACARP Project C20033

Heat-Shrinkable Tubing

Welding Clips. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Zip-Tex Spray Gun. Instructions A. Model psi (0.86 MPa, 8.6bar) Maximum Working Pressure

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Operating and Maintenance Instructions. Abteilung TB, Schell Seite 1 8 SERIES 56

(KERNEL) SAND BLAST CABINET ( 220L ) ASSEMBLY & OPERATION INSTRUCTION

INSTALLATION/OWNERS MANUAL

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover

Analysing Accuracy and Blast Hole Loading Techniques To Reduce Vibration 2008

INSTALLATION INSTRUCTIONS

VentureClad Insulation Jacketing Tapes 1577 Series

3M - A Global, Diversified Technology Company

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

PRESENTATION OF NITROERG S.A. Seminar: Polish Contribution to the EU Raw Materials Initiative Brussels, 6th November, 2017

650mA Phase Dimmable LED Driver

PORTABLE TRASH PUMPS MTP200 MTP300 MTP400

Model For petroleum products and other fluids compatible with aluminum and buna-n seals.

Installation Instructions Pro Stick Shifter

Series Description. 2 Specifications. Traffic Safety and Security Division. Product Bulletin Series 4000ESV 06/2017

INSTALLATION INSTRUCTIONS

ABRASIVE BLAST CABINET

PSI Anti-Corrosion Tape

IMPORTANT SAFETY INSTRUCTIONS

APPENDIX B. Demolitions

BusPro Series Instruction Manual

CFT24 &CFT230 PART NOS:

4000 Series TRS1 Spark Ignited Gas Engine rpm

Branch Splice QS-2001B

Blizzard, PO Box , Milwaukee, WI UNDERCARRIAGE KIT. Dodge Ram 1500 Mega Cab Installation Instructions

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Utility Mount. Tailgate Spreaders. Installation Instructions CAUTION. Read this document before installing or operating the spreader.

Grapple Kit Install & Grapple Bucket Manual

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

Operating Instructions & Parts Manual. Portable Power Supply & Jump Starter ! WARNING

PORTABLE TRASH PUMPS MDP200

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Spray Nozzle Adapters

Panel Bonding Adhesive

REINFORCED LOW & HIGH PRESSURE SPRAY/TRANSFER HOSES. One-piece lengths. Service Temperature Range: -40 F (-40 C) to +125 F (+52 C)

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

1000mA - 650mA Phase Dimmable LED Driver

MANUAL HOISTING TAKE THE WEIGHT OUT OF HEAVY DUTY LIFTING

Surface Protective Systems

PRO RATCHET UNIVERSAL SHIFTER

MSD Pro-Billet Digital E-Curve Distributor PN U.S. Patent

HYDRAULIC HOSES. FlexIT 018

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

Transcription:

PRIMADET non-electric delay detonators Dual StoperTM Dual DetTM EZ Stoper EZ Platinum trunklinetm function The Dual StoperTM non-electric blast initiation system is a precise, reliable and millisecond accurate system for sequential blasting in underground stoping, bord & pillar and in-stope tunnelling applications. The combination comprises of a Dual DetTM and either an EZ Stoper or EZ Platinum TrunklineTM unit. They provide a fast, simple and cost effective hook-up while allowing an unlimited number of holes to be shot with inherent sequential timing. description The Dual StoperTM non-electric blast initiation systems (EZ Platinum TrunklineTM + Dual DetTM or EZ Stoper + Dual DetTM ) are comprised of the following main components: Shock tube to transmit a signal to the delay cap. The shock tube is a 3mm diameter plastic laminated tube coated inside with a thin layer of HMX / Aluminium dust, which reliably transmits a low energy signal at approximately 2000m/s from one point to another. Due to the shock tube construction and inner Surlyn tube, the low energy signal will propagate through most sharp bends, knots and kinks that may occur in the shock tube. The outer surface of the tube remains intact during and after functioning. The distinguishable tough, orange outer jacket gives excellent abrasive, oil resistant and tensile properties. The EZ Stoper and EZ Platinum TrunklineTM have a precise surface delay. The delay train contains integral delay elements, anti-static protections and patented safety devices. Standard delay times can vary according to requirements and combinations. The EZ Stoper and EZ Platinum TrunklineTM have a surface connector block that is used to attach the surface blasting cap to the next EZ Stoper and Dual DetTM or EZ Platinum TrunklineTM and Dual DetTM in the chain. This surface connector and cap will reliably initiate up to 3 shock tubes if properly connected, in both directions. The EZ Stoper and Dual DetTM have a precise non-electric, in-hole (8D) detonator that will initiate all cap sensitive explosives and ANFO. Standard delay times can vary according to requirements and combinations. Tape used to bind each unit in a coil, facilitating easy deployment and a reduced chance of tangling. A delay tag to indicate the nominal delay time of the detonators.

advantages simple/flexible accurate reliable The Dual Stoper TM non-electric blast initiation system is factory assembled to the required length and delay time. They can readily and simply be connected to accommodate both basic and complex stoping, bord & pillar and tunnelling initiation requirements. The Dual Stoper TM non-electric delay detonators are manufactured using the most modern robotic production techniques resulting in extreme accuracy and precision. The Dual Stoper TM non-electric blast initiation system is factory assembled-to-order under stringent quality specifications. Continued technological advancement has resulted in patented design changes providing increased reliability, blast after blast. External layer (over-extruded plastic jacket of low density polyethylene) for abrasion resistance and UV protection Middle layer for tensile strength, elongation and chemical resistance Inner Layer (Surlyn) reliably holds the reactive mixture in place Primadet shocktube properties Tensile strength 18kg Elongation 320% Chemical resistance >24 hours at 70 C Fuel resistance Superior oil / diesel resistance Low reactive material No fumes / gasses Non-electric Immune to radio frequencies Initiation by means of a shock wave No fire risks Robust Will propagate through knots & kinks 2

cost effective custom packaging safe The Dual Stoper TM non-electric delay detonators, due to their reliability and sequential firing, provide improvements in advance per blast, hanging wall conditions and fragmentation. Custom packaging densities and combinations are available on request. Cushion Disc* Wipes inside of shell of primary explosives. - Increases shock resistance. - Prevents instantaneous detonation. Sealer Element & Sealer Crimp Maintains constant pressure within detonator as main delay burns. - Improves timing due to consistent pressure within detonator chamber. Starter Element Ensures consistent ignition of less sensitive main delay. - Improves reliability and accuracy of unit. Delay Ignition Buffer* (DIB Screen) Prevents reverse propagation. - Flame from delay cannot initiate shocktube and second detonator. Prevents delay suck-out. - Pyrotechnic delay powder held in place within detonator shell. * Patents. 3

applications Above are typical examples of tie-ups using the Dual StoperTM non-electric blast initiation system that could be applied. 4

primer assemblies If cartridged explosives are being used as a primer, a hole of the correct length must be punched into the primer using a non-ferrous primer punch. Once the hole has been made, the EZ Stoper or Dual Det TM in-hole detonators can be inserted into the cartridge. The shock tube lead can then be half-hitched around the cartridge, for extra security with regard to detonator pull-out. The primer is then inserted into the charge hole according to the mine standard. If ANFO or pumpable emulsion explosives are used, the EZ Stoper or Dual Det in-hole detonators must be inserted as far as practically possible (bottom third of hole), according to mine standard. Always ensure that there is enough shock tube lead to connect onto the lead of the next unit. important instructions Please note the following: Reverse priming is beneficial as the detonator points towards the explosive column, however priming of the charge hole must be done in accordance with the mine standard. Ensure that the EZ Stoper or EZ Platinum Trunkline TM is properly connected to the next unit(s) ( GRIP IT, CLIP IT, SLIDE IT ). Grip It Clip It Slide It The starter initiator must only be attached, once the entire face has been charged and hooked up. An EZ Platinum Trunkline TM is connected to the first hole(s) to be fired. The detonator of the starter initiator is attached to the EZ Platinum Trunkline TM with the use of an EZ Clip or electrical tape. Instantaneous Electrical Detonator (IED) and EZ Clip Instantaneous Electrical Detonator (IED) and tape Capped Fuse and EZ Clip SafeStart 5

Ensure that all the shock tube leads (1-3) are securely clipped into the EZ Platinum Trunkline TM connector block. The detonator of the starter initiator should be covered with mud to prevent shrapnel from damaging any shock tube leads. All detonators (surface and in-hole) are subject to detonation caused by abuse such as impact, tampering and general misuse. Never attempt to disassemble any detonators due to the above reasons. The shock tube should not be cut or damaged as moisture or dirt entering the tube could cause misfires. Holes loaded with this product and awaiting firing should be guarded or barricaded to prevent unauthorised entry, as per mine standard. Always slide the connector block to the collar of the hole after the connection is complete. Only load (1-3) shocktube leads in the EZ Stoper block as excessive loading may & will result in misfires. Always store detonators and explosives separately. Keep accessories away from sparks, flames or any other sources of ignition. Excessive temperatures may result in spontaneous ignition of explosives and accessories. Store explosives and accessories according to the country rules & regulations. packaging information Additional product lengths and packaging densities are available on your request. Please contact your representative. 6

standard packaging Dual Stoper (DS) - A Pack Case dimensions 605mm X 315mm X 460mm Product & length EZ Stoper EZ Stoper length Dual Det Dual Det length Units per case (m) (m) 220 2.4 200 3.6 420 150 2.4 150 4.2 300 125 2.4 125 5.4 250 Dual Stoper (DS) - A Pack Case dimensions 605mm X 315mm X 460mm Product & length EZ Platinum EZ Platinum Dual Det Dual Det length Units per case Trunkline TM Trunkline TM (m) (m) 136 1.2 272 6.0 408 110 1.2 220 7.8 330 EZ Stoper - A Pack PT Trunkline - A Pack Case dimensions (mm) 605 X 315 X 460 Case dimensions (mm) 605 X 315 X 460 Product length Units per case Product length Units per case 1.8 400 1.2 400 2.0 400 1.8 400 2.4 275 3.0 175 3.0 275 4.2 175 3.6 275 5.4 175 4.2 225 6.0 150 4.8 225 8.4 150 5.4 225 10.2 125 Dual Detonators (BS) Case dimensions (mm) 605 X 315 X 460 Length (m) Units per case 3.0 400 3.6 400 4.2 400 4.8 400 5.4 330 6.0 330 7.8 300 8.4 300 7

colour codes & labelling Connector block colours change according to delay or delay combinations. EZ Stoper Delay combination (ms) Block colour 3800 / 200 White 4000 / 400 Green 1800 / 75 Brown recommended storage, shelf life & transport Dual Stoper TM Recommended storage 6 months (dry, well ventilated) Shelf life 24 months Transport: UN classification 1.1B UN number 0360 Zax number 355A warning and disclaimer All products and equipment manufactured and supplied by Sasol Dyno Nobel shall be used, handled, stored or transported according to the guidelines laid down by the relevant applicable legislation in that country. Explosive accessories should be secured in an explosive magazine. All or any part of the explosive accessories is dangerous and can cause injury or death. If you find any of these items, do not touch them. Instead, immediately report their location and description to the police. To the extent provided for in terms of section 61 of the Consumer Protection Act, 2008, Sasol Dyno Nobel shall not be liable for any damage, whatever its nature, including incidental, consequential and indirect damage caused to buyers or third parties, directly or indirectly arising from or relating to the supply, use or storage of the products and equipment arising after delivery unless caused by Sasol Dyno Nobel s wilful misconduct or gross negligence. *Trademarks are registered or applied marks are licensed to Sasol. 8 Sasol Dyno Nobel (A division of Sasol Chemical Industries Limited 1968/01/391/06) 15 Baker street Rosebank 2196 PO Box 5486 Johannesburg 2000, South Africa +27 (0) 11 441 3111 www.sasol.com Rev 2 September 2013