Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

Similar documents
Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Benefits, typical uses


NXAirS Withdrawable Medium-Voltage Switchgear up to 24kV Air-Insulated

NXPLUS C Single busbar. Maintenance-free for lifetime

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

8DJ. Maintenance-free for lifetime

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

Medium-Voltage Switchgear OPERATING INSTRUCTIONS

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

VB1-D Generator Circuit-Breaker Switchgear

Metal Clad Air Insulated Switchgear

PIX-H Metal-clad switchgear up to 17.5kV

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Air-Insulated Medium-Voltage Switchgear NXAIR, up to 24 kv

CPG.0 Single busbar gas-insulated cubicles

Metal Clad Switchgears

UniGear. Technical Guide

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Switchgear Type 8DJH 36 for Secondary

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

ZX2.2 Gas-insulated medium voltage switchgear

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

Catalog HA Edition Medium-Voltage Switchgear. siemens.com/nxair

with Vacuum Circuit Breaker HAF

36kV Gas Insulated Medium Voltage Switchgear

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to 24 kv, SF 6 -Insulated. Medium-Voltage Switchgear Catalog HA 35.

B kv T&D GAS INSULATED SWITCHGEAR

the safe, reliable, and efficient choice for MV switchgear

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

Air-insulated switchgear UniGear type ZS1

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

HIGS Highly Integrated Generator Circuit-Breaker Switchgear

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Gas Insulated Metal-clad Switchgear, HMGS!

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS up to 40.5 kv, Gas-Insulated

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Vacuum Circuit Breaker

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

ZX-Family Gas-insulated medium voltage switchgear

Vacuum Circuit Breaker VS1

ZX2 Gas-insulated medium voltage switchgear

B kv Gas-insulated Substations

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

Fixed-Mounted Circuit-Breaker Switchgear up to 36 kv, SF 6 -Insulated

Product Specification

Instruction for Installation and Operation

Reliable Solution for Power Distribution. Air-Insulated Medium-Voltage Switchgear: Cost-Efficient, Sustainable and Safe

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Gas-insulated medium-voltage switchgear. For marine and offshore applications. Answers for energy.

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Medium voltage vacuum circuit breaker. E-VAC series

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

MESG 12 / 17.5 / 24 / 36 KV

Xiria the smart solution

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

W 12 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. DRIESCHER - Air-Insulated Medium-Voltage Switchgears

Power Xpert UX 36 High-voltage switchgear system. Reliable and safe for high performance applications

Modular medium-voltage switchgear. NorMax

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

Features. 2 Siemens HA Page. 8DJ10 switchgear is a factoryassembled,

Transcription:

www.siemens.com.cn/medium-voltage-switchgear Air Insulated Switchgear NXAirS, Answers for infrastructure and cities.

Applications Page Application Type 2 Typical uses 3 Classification 3 Type NXAirS withdrawable metal enclosed medium voltage switchgear is indoor switchgear, type tested, in compliance with GB3906-2006, DL404-2007, IEC 62 271-200, GOST 1516.3-96 standards Loss of service continuity category LSC 2B Partition class PM(metal) Internal arc classification (IAC) A FLR 31.5kA 1 second Customers' benefits Peace of mind 4 Save lives 5 Increase productivity 6 Saves money 7 Preserves the environment 8 Technical data Electrical parameters and dimension 9 Design data 10-12 Transport and packing 13 Offer range (Primary circuits) Circuit breaker panel, incoming/outgoing, offer A 14 Disconnector panel, offer B 15 Sectionalizer panel, offer C 16 Sectionalizer panel, offer D 17 Metering panel, offer E 18 Auxiliary transformer panel, offer F 19 Design instruction Switchgear design features 20-22 Components Vacuum circuit breaker 23-25 Standards Standards, criteria and guidelines 26-27 NXAirS Maximum rating /31.5kA/3150A 2

Applications Typical uses NXAirS withdrawable metal - enclosed medium voltage switchgear is used in substation and power distribution system, mainly for primary power distribution system: Application Public power supply Power supply companies Energy producers System operators. Application Industry Power stations Cement industry Iron and steel works Rolling mills Mining industry Chemical industry Petroleum industry Pipeline installations Offshore installations Electrochemical plants Petrochemical plants Lignite open-cast mines Traction power supply systems. Classification The switchgear is designed and manufactured in accordance with GB3906-2006, DL404-2007, IEC 62 271-200 standards, and the following classes Loss of service continuity category and degree of protection Loss of service continuity category LSC 2B Partition class PM (metal) Accessibility to compartments Busbar compartment Switching device compartment Connection compartment Bus Room High voltage room Cable vault Internal arc classifications The following internal arc classification are fulfilled: IAC A FLR, I SC, t IAC A F L R I SC t Tool-based Interlock-controlled Interlock-controlled or tool-based Pecial tools must be used In compliance with interlock control requirements In compliance with interlock control requirements or special tools are used =internal arc classification =300mm distance of indicators for test (installation in closed electrical service location) =Front arrangement of indicators for test =Lateral arrangement of indicators for test =Rear arrangement of indicators for test =Test current for up to 31.5kA =Arc duration 1 s In this way, switchgear is suitable for unrestricted application (wall or free-standing arrangement) in electrical service locations up to the maximum short-circuit ratings. 3

Customers' benefits Peace of mind For power supply companies and industrial plants, the platform concept of the NXAIR family introduced at all production locations has very concrete advantages: Smooth operation, exemplary availability and optimal safety. Features No handling of insulating gas and low and high pressure monitoring required As insulating medium, air is always available Factory-assembled, type-tested switchgear according to IEC 62271-200, GB3906-2006, DL404-2007 Platform concept introduced worldwide, centrally controlled development, local manufacture Use of standardized block-type current transformers Use of standard components available worldwide More than 450,000 air-insulated switchgear panels of Siemens in operation worldwide Use of maintenance-free vacuum circuit-breakers Type testing of the vacuum circuit-breaker and the make-proof earthing switch in the panel Pressure-resistant partitions Flexibility regarding the low-voltage equipment (removable compartment, plug-in wires) Quality assurance in accordance with DIN EN ISO 9001. 4

Customers' benefits Save lives All switchgear types of the NXAIR family are approved with internal arc classification IAC A FLR, loss of service continuity category LSC 2B and partition class PM. This makes them suitable for universal installation, meeting the highest requirements regarding personal safety. Features All operations with closed high-voltage door Metallic enclosure, earthed shutters and partitions Internal arc classified switchgear according to IAC A FLR; front, lateral and rear accessibility; for all short-circuit currents and an arc duration of 1 s Loss of service continuity category LSC 2B (separate partitions for the busbar, connection and switching device compartments) Partition class PM Unambiguous position indicators and control elements on the high-voltage door Use of vacuum circuit-breakers or contactors Standard degree of protection IP4X Positively driven shutters (separately lockable) Logical mechanical interlocking system. 5

Customers' benefits Increases productivity Properties such as modular design, type tests of the circuit-breaker in the switchgear, confinement of an internal arc to the respective compartment, and thus maximum operational reliability, contribute to optimized operation and a remarkable increase of productivity. Features Loss of service continuity category LSC 2B (separate partitions for the busbar, connection and switching device compartments) Partition class PM Positively driven shutters Use of standardized block-type current transformers Cable testing without isolating the busbar Functions such as establishment of the isolating distance, as well as feeder and busbar earthing, can be completely controlled from remote Confinement of an internal arc to the respective compartment Use of maintenance-free vacuum circuit-breakers Control cables in metallic wiring ducts Easy access to all panel components. 6

Customers' benefits Saves money The compact design of the NXAIR family pays twice for owners due to the use of the new SION circuit-breaker series. On the one hand, building costs can be reduced in this way, and on the other hand, the maintenance-free circuit-breakers and the modular design enable continuous operation without expensive shutdown times. Features Use of maintenance-free vacuum circuit-breakers Interruption of operation reduced to a minimum by logical mechanical interlocking system Minimized space requirements (reduced building investments) due to compact design and flexible cable connection options and/or flexible pressure relief duct systems. 7

Customers' benefits Preserves the environment Air used as insulating medium, local production locations with short transportation ways and times, as well as a service life > 30 years, optimize the total energy balance. Features As insulating medium, air is absolutely neutral to the environment Local production presence in all regions, minimized energy consumption (CO 2 ) regarding transport Service life > 30 years optimizes the energy balance additionally The materials used are fully recyclable without special knowledge Easy disposal. 8

Technical data Electrical parameters and dimension Electrical parameters rating - rated voltage kv 40.5 - rated frequency Hz 50 - rated 1 min short time power frequency withstand voltage phase - to - phase, to ground (through disconnections) kv 95 (118) - rated lightning impulse withstand voltage phase - to - phase, to ground (through disconnections) kv 190 (215) - rated short circuit breaking current ka 25,31.5 - rated short time withstand current, 4 s ka 25,31.5 - rated short circuit making current ka 63,80 - rated peak withstand current ka 63,80 - rated main busbar current A 1250, 2500, 3150 - rated feeder current A 1250, 2500 Dimensions and weights Width W mm 1200/1400 1) Height H mm 2800/3010 2) Depth D mm 2650/3450 3) Weight kg 1800~2300 Low voltage box dimensions Standard type W mm 1200/1400 1) H mm 705 D mm 450 Cable compartment dimensions W mm 1200/1400 1) H mm 1280 Distance from cable terminal to the ground mm 750 1) Auxiliary transformer panel 2) Switchgear with absorber 3) Extended design 9

Air Insulated Switchgear NXAirS Technical data Design data Panels design if the height of the room is too low, please consult Siemens The different absorbers are for different ratings of the switchgears 31.5kA 1250A circuit breaker panel 31.5kA 1250A disconnector panel 31.5kA 2500A disconnector panel 10 31.5kA 2500A circuit breaker panel Auxiliary transformer panel

Technical data Design data Single row arrangement (top view) For width and depth, see electrical parameters and dimension part. To facilitate the replacement of switchgear, advisable operating corridor in front of the cabinet should be no less than 3000mm, the distance from the top of the switchgear to the ceiling of switch room should be no less than 800mm. Face to face arrangement, switch room may be determined according to the dimension of single row arrangement. Size should be reserved in the switch room, and corresponding building regulations must also be consulted. Floor cutouts and mounting Typical Foundation Frame Layout Switchgear fixation Welding for fixation Bolting 10# channel steel Cable layout In mm Typical Section Layout (A-A Section) Note: * the marked dimension should be determined according to actual opening on the base plate of the switchgear ** the marked dimension should be adjusted correspondingly if busbar bridge is installed Top of the foundation frame should be 1 3mm above ground Cover plate for control cable trench 5mm thick checkered plate Control cable trench 250 X 250 Control cable trench 800 X 1500 In mm Example of the switchgear arrangement Power cable trench NXAirS switchgear Control cable trench In mm Note: * refers to single row arrangement dimension for switchgear, if the switchgear adopts double row face-to-face arrangement, the recommended distance between two rows of switchgear should be no less than 3000m. ** specific dimension of control aisle should be determined according to actual space of the switch room W=1200/1400mm D=2650mm (standard depth) H=2800mm 11

Technical data Design data Switchgear plane foundation drawings 31.5kA 1250A circuit breaker and disconnector panel Switchgear fixation Welding for fixation Bolting 10# channel steel 31.5kA 2500A circuit breaker and disconnector panel 1 Bottom frame of the switchgear 2 HV door of the switchgear 3 Switchgear mounting hole 20x20 mm 4 Secondary cable outlet 5 End wall 6 10# channel steel 100x48x10 7 Main grounding copper bar (in the cabinet) 8 High voltage cable connecting outlet Auxiliary transformer panel Switchgear fixation Welding for fixation 10# channel steel Bolting Precautions for groundwork structure: Groundwork must adopt artificial floor, double floor or concrete groundwork; Concrete groundwork must adopt channel steel for fixing the switchgear; Tolerance zone should comply with DIN 43661; Linearity within 1 m should be 1 mm, linearity on the whole length should be 2 mm; average measured linearity within 1 m should be 1 mm. Switchgear fixation Welding for fixation 10# channel steel Bolting 12

Technical data Transport and packaging Transport Only one panel per pallet is possible. The following factors should be considered in selecting the size of transport unit: Transport facilities on site Transport weights and dimensions Size of door openings in building Number of switchgear on pallet W m Dimension, volume and weight D m H m Volume m 3 Gross weight is about kg 1 unit 1.50 3.00 3.00 13.50 2300 Packing There are three kinds of packing available Packing type Simple Transport method Highway Packing method The switchgear is placed on wood pallet, covered by polyethylene film bag Standard Railway and highway The switchgear is placed on wood pallet, covered by polyethylene film bag, packaged in wooden boards Export Shipping Switchgear is placed on wood pallet, vacuumized and sealed by polyethylene film bag, with desiccant inside, packaged in fumigated wooden boards, maximum storage period is 6 months 13

Offer range (Primary circuits) Circuit breaker panel, Incoming/Outgoing, Offer A A 09 A 10 A 11 A 12 A 13 A 14 A 15 A 16 14

Offer range (Primary circuits) Disconnector panel, Offer B B 09 B 10 B 11 B 12 B 13 B 14 B 15 B 16 15

Offer range (Primary circuits) Sectionalizer panel, Offer C 16

Offer range (Primary circuits) Sectionalizer panel, Offer D D 11 D 12 17

Offer range (Primary circuits) Metering panel, Offer E E 01 E 02 E 03 E 04 E 05 E 06 E 07 E 08 E 09 E 10 18

Offer range (Primary circuits) Auxiliary transformer panel, Offer F F 01 F 02 Note: special design could be offered for different panel types according to the project requirements Please contact Siemens representatives 19

Air Insulated Switchgear NXAirS Design instruction Switchgear design Features Integrated mimic diagram Recognition of the respective switch positions, circuit-breaker CLOSED / OPEN, disconnected position, earthing switch CLOSED / OPEN, on the integrated mimic diagram Unambiguous assignment of actuating openings and control elements to the corresponding position indicators All switching operations always with high-voltage door closed Ergonomically favorable height for all control and indicator elements O pt i o n : Ve r i f i c a t i o n o f s a fe isolation from supply for feeder or busbar by means of the capacitive voltage detecting system with panel front closed. Interlocks Interlocking conditions specified according to IEC 62271-200 / GB 3906-2006 are fulfilled Feeder earthing switch can only be operated with switching device in disconnected position Switching device can only be racked on the movable part with the associated switching device in OPEN position and with earthing switch OPEN Switching device can only be operated in interlocked disconnected or service position. 11 1 12 20 19 18 2 3 4 7 8 5 6 9 17 16 10 1. Low voltage room door lock 2. Manual charging handle hole 3. High voltage room door lock 4. Handle for opening the door of high voltage room 5. Inspection window to recognize close/open state of the circuit breaker, energy storage and counting observation hole 6. Withdrawable part position/test position state indication observation window 7. Circuit breaker closing button 8. Circuit breaker opening button 9. Mechanical position indication and actuating opening of the earthing switchgear 10. Chassis in/out operating hole 11. Pressure release channel 12. Busbars 13. Circuit breaker 14. Withdrawable part 15. Earthing switch Beyond the specifi cations of the standards Coding prevents inser tion of switching devices with a lower rated normal current into panels w i t h a h i g h e r r a te d n o r m a l current Interlocking between the highvoltage door and the position of the withdrawable part Option: Electromagnetic interlock s, mechanical key interlocking systems, padlocks. 20 16. Cables' connection 17. Current transformer 18. Fixed contact in the bushing type insulator 19. Withdrawable contact of the circuit breaker 20. Contact cover box 13 14 15

Design instruction Switchgear design Panel enclosure consists of bolted steel frame and steel plates the withdrawable part is supported by guide rails steel frame and steel plate adopt galvanized/ aluminized zinc plates door and front frame are painted with RAL7035 standard color powder coating Partition between compartments end plate is painted with RAL7035 standard color powder coating the bolted galvanized steel plates divide the switchgear into: busbar compartment, circuit breaker compartment and cable compartment degree of protection between separate compartments is: IP2X since contact cover box with embedded contacts is used, the compartments are not connected even if the withdrawable part is in work position upper and lower fixed contacts are fixed on the contact cover box to move the withdrawable part, metal shutter may be opened or closed by mechanism after the withdrawable part is pulled out, metal shutter covers the contact cover box upper shutter (accessible to BBC) or lower shutter (accessible to CC) may be unbolted for removal, there is no contact between them Pressure relief channel (partial) Partition The function of partition is to separate the adjacent cubicles into compartments without connection galvanized steel plate partition class PM partition with bushing can be selected in busbar compartment, degree of protection with adjacent panel should be IP4X Cable compartment Pressure relief Any excess pressure generated by arc fault in the panel may be released upward by pressure absorber on top of the panel or guided out of the switchgear room by pressure velief channel galvanized steel plate busbar compartment, high voltage compartment and cable compartment have their own pressure release channels 21

Design instruction Switchgear design Switching device compartment Enclosure made of aluminum zinc plate Pressure relief upwards Panel front powder-coated with epoxy resin Standard color RAL 7035 Separate shutter mechanism for opening and closing the Busbar compartment Connection compartment High-voltage door pressure-resistant in the event of internal arcs in the panel Pressure-resistant partitions to connection and busbar compartments Low-voltage plug connector for connection of control cables between primary part and secondary part; Switching device compartment with withdrawable devices: Vacuum circuit-breaker Disconnector link Metering unit Endurance classes for: Circuit-breaker: E2, M2, C2 Isolating distance (withdrawable part): M0 manually or optionally motor-operated for withdrawable circuitbreaker and disconnector link Busbar compartment Enclosure made of aluminum zinc plate Pressure relief upwards Busbars made of flat copper, bolted from panel to panel: Coated with epoxy resin powder Pressure-resistant partitions to connection and switching device compartment, pressure-resistant rear wall Shutters can be opened and locked separately Bushing-type insulators for supporting the busbars and for accommodating the upper fixed contacts for the switching device Top-mounted compartment above the busbar compartment within the pressure relief duct Options: Possibility of installing the following components Voltage transformers Make-proof earthing switch (endurance class: M0, E1), manual or optionally motor operation. Busbar compartment Cable compartment Enclosure made of aluminum zinc plate Pressure relief upwards through rear pressure relief duct Pressure-resistant partitions to switching device and busbar compartment Shutters can be opened and locked separately Earthing busbar Pressure-resistant floor cover Connection from front/bottom, or from rear/bottom, or from rear/top Suitable for connection of: Single-core XLPE cables up to 4 500 mm 2 depending on the rated normal current and other built-in components Three-core cables 4 300 mm 2 per panel depending on the rated normal current and other built-in components Installation of voltage transformers Cast-resin insulated 3 1-pole Fixed-mounted, without primary fuses Make-proof earthing switch With manual operating mechanism, optionally motor operating mechanism In addition to the standard interlock: Earthing switch optionally lockable or electromagnetically interlocked against the withdrawable switching device Endurance class for earthing switch: M0, E1 Surge arrester 22

Components Vacuum circuit breaker Features 3AE embedded pole circuit breaker in compliance with IEC 62 271-100 and GB 1984-2003 standards ideal contact material and shape could ensure small chopping current and lifetime stable contact resistance all parts meet Siemens German quality standards complete type testing high electromechanical life Maintenance free within 10,000 operating times under normal conditions reasonable and compact structure, ensure more reliable operation, more safe and ideal breaking characteristic of inductive and capacitive loads 64 - pole low - voltage plug connector between circuit - breaker and fixed part 3AE vacuum circuit breaker 23

Components Switch elements Secondary wiring diagram of the vacuum circuit breaker Motor control circuit Closing spring charging signal Closing coil and anti-trip contactor Circuit breaker trip signal S1 auxiliary switch S1 auxiliary switch K1 anti - pumping relay module Y1, Y9 opening coil, closing coil M1 universal motor S3, S6, S7, S12 position switch S21, S22, S42 position switch This wire is added when the withdrawable part is electrically driven Note: 1) circuit breaker is in, test position, opening, uncharged state. 2) mark 1 is optional part, please indicate your requirements in the order if it is required. 3) wire of withdrawable part position switch is led out of the circuit breaker to 1.5m 4) for detailed terminal connection diagram, please consult Siemens AG 24 Test position Work position withdrawable part position switch

Components Switch elements Electrical and mechanical data of vacuum circuit breaker * Type Unit 3AE Rated voltage kv 40.5 1 minute power frequency withstand voltage kv 95 Lightning impulse withstand voltage kv 190 Rated operation sequence 0-0.3s - co - 180s - co Phase - to - phase center distance mm 300 Rated current max. A 3150 Rated short circuit breaking current max. ka 31.5 Rated short time withstand current/time max. ka/s 31.5/4 Rated mechanical life C-O operations 30000 Maximum making current ka 80 Rated peak withstand current ka 80 Closing time ms <75 Opening time (Y1) ms <60 Opening time (secondary release) ms <55 Breaking time ms <80 Arcing time ms <15 Closing/opening asynchronism ms 3 Dead time ms <300 Breaking time ms <80 Operating mechanism charging time s 15 * : refer to the catalogue of 3AE circuit breaker 25

Standards Standards, criteria and guidelines Standards The switchgear complies with the relevant standards and specifications applicable at the time of type testing IEC standard GB standard Switchgear NXAirS, IEC 62271-1 GB/T 11022 IEC 62271-200 GB 3906 Circuit-breaker IEC 62271-100 GB 1984 Vacuum contactors IEC 62271-106 GB 14808 Disconnectors and earthing switches IEC 62271-102 GB 1985 Devices Switch-disconnectors IEC 60265-1 GB 3804 Switch-disconnector/fuse combination IEC 62271-105 GB 16926 HV HRC fuses IEC 60282-1 GB/T 15166.2 Voltage detecting systems IEC 61243-5 GB 12325 Degree of protection - IEC 60529 GB/T 4208 Insulation - IEC 60071 GB 311.1 - IEC 61869-1 GB 20840.1 Instrument transformers Current transformer IEC 61869-2 GB 1208 Voltage transformer IEC 61869-3 GB 1207 Installation, erection - IEC 61936-1 GB/T 11024.1 Type of service location The switchgear can be used as indoor installation according to IEC 61936 (Power installations exceeding AC 1 kv) and VDE 0101 Outside lockable electrical service locations at places which are not accessible to the public. Enclosures of switchgear can only be removed with tools In lockable electrical service locations. A lockable electrical service location is a place outdoors or indoors that is reserved exclusively for housing electrical equipment and which is kept under lock and key. Access is restricted to authorized personnel and persons who have been properly instructed in electrical engineering. Untrained or unskilled persons may only enter under the supervision of authorized personnel or properly instructed persons. Table insulating strength Rated voltage (effective value) kv 40.5 Rated short time power frequency withstand voltage (r. m. s.) - isolating distance kv 118 - phase - to - phase, to ground and circuit breaker breaks kv 95 Rated lightning impulse withstand voltage (peak value) - isolating distance kv 215 - phase - to - phase, to ground and circuit breaker breaks kv 190 Altitude correction factor ka Correction factor Power frequency test voltage Impact test voltage Altitude on the installation site Rated power frequency withstand voltage 1.1 Ka Rated lightning impulse withstand voltage 1.1 Ka Dielectric strength The dielectric strength is verified by testing the switchgear with rated values of short-duration powerfrequency withstand voltage and lightning impulse withstand voltage according to IEC 62271-1. The rated values are referred to sea level and to normal atmospheric conditions (1013 hpa, 20, 11 g/m3 humidity according to IEC 60071). The dielectric strength decreases with increasing altitude. For site altitudes above 1000 m (above sea level) the standards do not provide any guidelines for the insulation rating, but leave this to the scope of special agreements. Site altitude The dielectric strength of air insulation decreases with increasing altitude due to low air density. This reduction is permitted up to a site altitude of 1000 m according to IEC. For site altitudes above 1000 m, a higher insulation level must be selected. It results from the multiplication of the rated insulation level for 0 to 1000 m with the altitude correction factor K a. 26

Standards Standards, criteria and guidelines Current carrying capacity According to IEC 62271-1 and IEC 62271-200, the rated normal current refers to the following ambient air temperatures: Maximum of 24-hour mean + 35 C Maximum + 40 C The rated normal current of the panels and busbars depends on the ambient air temperature outside the enclosure. Protection against solid foreign objects, electric shock and water Switchgear fulfills according to the standards IEC 62271-200 IEC 60529 GB 11022 GB 3906-2006 the following degrees of protection: Switchgear panel Degree of protection for the enclosure Degree of protection for the enclosure with ventilation Degree of protection for the partitions Climate and environmental influences IP4X IP4X IP2X Switchgear is suitable for application in indoor installations under normal operating conditions as defined in standard IEC 62271-1 as follows: Max. value of ambient air temperature: + 40, average value over period of 24 h: + 35 Minimum ambient air temperature: 5 25 (on request) Altitude of installation 1000 m Average value of relative humidity over period of 24 h: 95%, over period of one month: 90% Ambient air not significanted polluted by dust, corrosive gases, vapours or salt. The switchgear may be used, subject to possible additional measures, under the following environmental influences: Natural foreign materials Chemically active pollutants Small animals Internal arc classification Protection of operating personnel by means of tests for verifying the internal arc classi. cation Internal arcing tests must be performed in accordance with IEC 62271-200 The switchgear complies with all criteria speci.ed in the a.m. standards for the basic version up to 31.5 ka Comply with the internal arc classi. cation: IAC A FLR up to 31.5 ka, 1 s. This provides maximum personal safety of switchgear accessible from all sides De.nition of criteria: Criterion 1 Correctly secured doors and covers do not open, limited deformations are accepted Criterion 2 No fragmentation of the enclosure, no projection of small parts above 60 g Criterion 3 No holes in accessible sides up to a height of 2 m Criterion 4 No ignition of indicators due to hot gases Criterion 5 The enclosure remains connected to its earthing point Terms Make-proof earthing switches are earthing switches with shortcircuit making capacity according to IEC 62271-102 and the climate classes: 3K3 3K5. The climate classes are defined according to IEC 60721-3-3. 27

Technical support and service hotline Tel.: 400 810 4288 Fax: 010-6471 9991 E - mail: 4008104288.cn@siemens.com.cn Web: www.4008104288.com.cn Siemens Ltd. China Infrastructure and City Sector Low and Medium Voltage Division Subject to changes without prior notice Order No.: E20002-K5040-C1700-X-7600 1720-D909030-0514X Siemens AG All rights reserved This manual only provides general description and characteristic introduction of the product. Content in the manual might differ from practical applications, and might vary with further development of the product. Siemens is liable to provide product characteristic mentioned in the manual only when specified in relevant contract terms. All names in the manual might be trademark or product name of Siemens AG or its suppliers, any usage by any third party without authorization might infringe the owner's rights.