Vacuum Circuit Breakers kv

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

Operating conditions. Generalities. Normal operating conditions

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Metal Clad Air Insulated Switchgear

Air-insulated switchgear UniGear type ZS1

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

CPG.0 Single busbar gas-insulated cubicles

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

33KV INDOOR SWITCHGEAR

Vacuum Circuit Breaker VS1

0MV vacuum circuit breaker. 0Evolis 24 kv. 0User 0Manual. Creation Printed on 2008/07/17

VD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

PIX-H Metal-clad switchgear up to 17.5kV

VD4 Installation and service instructions kv A ka

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

Evolis offer Merlin Gerin

Outdoor vacuum breaker for railway applications - FSK II

1. Safety practices General Introduction Standards...3

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

GMA. Medium-voltage switchgear

Vacuum Circuit Breaker

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

TGI Vacuum Circuit-Breaker Air isolator Earthing switch

HVX. Vacuum circuit-breaker 12-17,5 kv ( 2500 A, 31,5 ka) Installation Operation Maintenance No. DRC NTV 142. Technical instruction.

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

the safe, reliable, and efficient choice for MV switchgear

MCset 4-24 kv Withdrawable SF6 circuit breaker

SF 6 Gas Insulated Load Break Switch

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Circuit breaker interlocking and operation requirements SIEMENS

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

cor Long Run Experience

PSW102 type CT powered protection unit

MESG 12 / 17.5 / 24 / 36 KV

Vacuum Circuit-Breaker Modules

Medium voltage vacuum circuit breaker. E-VAC series

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

NXPLUS C Single busbar. Maintenance-free for lifetime

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Metal Clad VCBs ~ Mk1

IEC Standard Compliant Vacuum Circuit-Breaker (12 kv, 24 kv) for Southeast Asian Markets

Unified requirements for systems with voltages above 1 kv up to 15 kv

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

HD4. Gas insulated MV circuit-breakers kv A ka

TECHNICAL SPECIFICATIONS

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

MEDIUM VOLTAGE SWITCHGEAR

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

B kv T&D GAS INSULATED SWITCHGEAR

Solid Dielectric, Single Phase Recloser

Indoor Metal Clad Switchgear Type:Cubicle VHA 36 SF6 Circuit Breaker HPA 36 Rated Voltage: ABB Power Distribution

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

PIX High. Medium-voltage switchgear. Air-insulated switchgear kv ( 50 ka) Assembly - Operation - Maintenance Technical Manual

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

HVX Vacuum circuit-breaker kv ( 2500 A, 40 ka)

Modular medium-voltage switchgear. NorMax

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

VD4. Installation and service instructions kv A ka

Typical Specification

Metal Clad Switchgears

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

Publication No.: PSG

DISTRIBUTION SOLUTIONS HA Breaker Retrofit. Medium Voltage Service Marketing and Sales

EMPAC Metal enclosed capacitor bank for wind applications

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

HD4. Gas insulated MV circuit-breakers kv A ka

Pro-MEC Vacuum Circuit Breakers Vacuum Interrupter

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Cobra-S. Catalog Cobra-S

Transcription:

Medium Voltage Distribution Vacuum Circuit Breakers 12-24 kv HVX withdrawable version Catalogue 2017

General Presentation Vacuum interrupter By the newest computer modeling tools, incorporating the comprehensive proven testing, Schneider Electric VG series achieves the true optimal design. With the most With our patent design and full knowledge of vacuum interrupter technology. Schneider Electric vacuum interrupter is distinctively outstanding in medium voltage field with its high reliability, small size and long service life. Wholly embedded-pole The embedded pole is another contribution of Schneider Electric to medium-voltage products, with its over 100 years experience in design and manufacture, originated from 40 years operation experience of outdoor high-voltage products application technology, which has been practical test proved. Employing the elastic material of good hermetic property, completely mounding the vacuum interrupter, main circuit and insulated shaft in an epoxy pole to realize total isolation of the main circuit from the extermal, which obtains the pole the highest adaptability with the environment, thus the breaker can function normally under bad environment. Operating mechanism HVX adopts a spring mechanism incorporating a single-shaft system, a sprial spring supplies the energy required in a standard on and off operation cycle. Cam output of three independent phases provides the optimal match of vacuum interrupter. The one step output of transmission mechanism and the particular axletree design has optimal transmission efficiency to ensure energy saving and stable, reliable mechanism. VG series vacuum interrupter Function theory Through the electric motor or manual crank, the energy required for a whole operating cycle is stored in sprial spring. The opening and closing of vacuum interrupter is control of the cam, upon closing, the spring automatically restore the energy for an integrated automatic on and off operating cycle. On and off preserving mechanism, with high-efficiency rubber and no grid contact among the transmission parts, can absorb the excessive energy of the dirve mechanism upon a quick on and off operation. The mechanism has electric and manual charging devices. The relevant interlock prevents the error manipulation after the energy storing. 01

Performance Tables Type HVX HVX 12-25-06/12-31-06 12-25-12/12-31/12 24-16-06/24-25-06 24-25-12 rated voltage 1 12kV 24kV rated current 630A 1250A 630A 1250A rated shortcircuit breaking current Isc 2 25kA/31.5kA 16/25kA 25kA power frequency withstand (50/60Hz 1min) 28kV 50kV lightning impulse withstand 75kV 125kV pole center spacing 150mm 210mm rated frequency 50/60Hz rated short-circuit making current Ip (50/60Hz) 2.5Isc / 2.6Isc rated short time withstand current (4s) 25kA/31.5kA 16/25kA operating sequence O-0.3s-CO-3 min-co O-180s-CO-3 min-co O-0.3s-CO-15s-CO mechanical endurance class M2 electrical endurance higher number of operation cycles upon maintenance plan class E2 30,000 operations service temperature -25 ~ +40 o C operating time opening 40-70ms arcing closing 15ms 30-60ms line charging breaking current 10A (class C2) cable charging breaking current 25A (class C2) standards IEC62271-100, CNS15156-100 1 17.5kV is also available, please contact us for more information. 2 Three-phase breaking capacity = Ur x Isc x 3 (MVA), Ex: 24kV x 25kA x 3 = 1039MVA. Secondary connections plug Upside moving tulip contact Wholly epoxy embedded pole (vacuum interrupter) Downside moving tulip contact Shutter lifting device Opening button Closing button Nameplate Spring status (charged or discharged) 1. manufacturer 2. breaker type 3. rated voltage 4. rated insulation voltage 5. rated current 6. rated short-circuit current 7. rated frequency 8. control voltage 9. serial number 10. standard 11. date of manufacture Circuit breaker position indicator (close / open / trip) Insertion opening for manual charging lever Operation counter Rollers Racking truck Option: Racking Trolley (CNS 15156) 02

Function Description Composition The racking in function is provided by: the racking truck (driven by screw) supporting the circuit-breaker (mobile part), the cradle including the bushings (fixed part), provision for padlocking in test and disconnect positions (option), the LV plug. The allowable voltage range for all electrical operations of the circuit-breaker is within 85% ~ 110%Un. auxiliary contacts: 5NO+5NC (4NO+4NC+1CHG) antipumping relay operation counter Operating Procedure The circuit-breaker moves through 2 stable positions (with indicators on the cradle): service position: circuit-breaker racked in and locked in place; low voltage plug connected. test and disconnect position: circuit-breaker racked out and locked in place; low voltage plug connected. Safety Functions A propulsive system combined with a screw-shaft makes racking in and racking out easier. Interlocking In accordance with IEC standards 62271-100 and 62271-200, the following interlocking is provided: racking in or out is impossible unless the circuit-breaker is in the open position. circuit-breaker CANNOT be withdrawn when the main contacts are in closed position. the main contacts of the circuit-breaker are forbidden to be closed when: a. circuit-breaker is in the process of being withdrawn or led-in. b. circuit-breaker is between the test and service positions. c. circuit-breaker is between the test and disconnedted positions. racking in or out is impossible during breaker s charging procedure. Metal-clad enclosed cradle with epoxy casting bushing eusures the safest construction. Earthing is achieved throughout the whole racking in operation by means of the wheels of the racking truck. Protective shutters on the cradle prevent access to the racking fingers when the device is extracted (protection index: IP2X). For maintenance or test purposes, it is possible to: padlock the shutters in the closed or open position (option) Earthing Switch (option) It can be fixed on the cradle, allowing proper interlocking between the circuit-breaker and the earthing switch. auxiliary contacts for earthing switch, cctivated when earthing switch is in open or closed position. Optional Parts Position Contact (2 or 4 racked in/out), activated when circuit-breaker is in the test or service position. Condenser Tripping Device (CTD, 2000μF) providing DC power for the unit to trip when encountering power failure. Communication Output (RS485 RTU) monitoring operating conditions and positions of circuit-breaker and earthing switch, can also provide remote control of circuit-breaker Earthing Switch Interlock Protection Mechanism (when interlocked with another breaker): locking the breaker in test or disconnected position and forbidding it to be closed. Under Voltage Release Key Locking Device (OFF position locking, forbidden to rack in/out the cradle) Interlock and Padlock device (pushbutton locking, forbidden to close or open the breaker) Auto-Discharge Function: the spring of the circuit-breaker operating mechanism is automatically discharged when the circuit-breaker is extracted from the cubicle. This feature avoids unexpected closing of the circuit-breaker. Arc Protection Relay: full time monitoring of arc flash of fault. The relay can detect arc flash via flash sensor, rapidly trip the circuit breaker when fault occurs. The relay can also be configured to trip only when BOTH over current and arc flash are detected, in order to give the circuit break best protection. The HVX racking trolley allows panel builders to design switchgear solutions with enhanced safety features. It has a robust interlocking system with the switchgear door, LV plug, circuit breaker, and ground switch. It can be equipped with an electric motor for remote racking from the control room. Conforming to CNS 15156 requirements. 03 Racking trolley

Secondary Devices Release Auxiliary switches F2, F11/F12 The coil of auxiliary release is actuated by auxiliary power supply. The coil is designed for short-term working, its main circuit is routed via an auxiliary switch contact controlled by the circuit breaker shaft, thus once released interrupting the current circuit. Over current release F3 (Transformer-type over current release)secondary release are used for automatic release of switching devices in case of short circuits and over current. Once the protector reacts, the release is actuated by the transformer current, thus causing the switching to be tripped. These releases are supplied for transformer secondary currents of 0.5A,1A and 5A. Under voltage release F4 Under voltage releases are supplied by the auxiliary source permanently. Wherever the auxiliary current is interrupted or its voltage drops essentially, the switching devices is tripped at once. Auxiliary switches Auxiliary switche in switching position S11/S12 Auxiliary switches are always actuated directly by the switch shaft via an intermediate linkage, their position always corresponding to the position of the main contacts, indicating on and off position status of the breaker, in wiring,the interlock assist the release to prevent the error manipulation. The circuit breaker is equipped in general with an auxiliary switch with 8 contact elements. Auxiliary switche in charging position S2 The auxiliary switch is mainly used for checking and indicating the charging status, it is connected by harging mechanism to assure that upon closing operating the driving mechanism can automatically store the energy. After charging finished, it breaks the electric charging circuit. The circuit breaker is equipped in general with an auxiliary switch with 8 contact elements. Anti-pumping relay Anti-pumping relay K01 If both an ON and OFF command are permanently present on the circuit breaker at the same time, the latter returns to its initial position after closing. it remains in this initial position until the ON command is issued again. This prevents continuous closing and opening(= pumping ). Counter Operation counter The counter is installed on the operation interface to record operation times of the breaker. Charging motor Motor M1 Electrically store the energy for the mechanism operation of the breaker,preparing the erengy for closing operation the next time. Blocking coil Blocking coil of closing Y1 Losing the secondary controlling power supply,the breaker can not perform normally closing operation(including manual closing operation). Blocking coil of movement track Y0 Losing the secondary controlling power supply,the trolly can not perform normally manual operation. Condenser tripping device & Arc protection relay Condenser tripping device (CTD, 2000μF) providing DC power for the unit to trip when encountering power failure. Arc protection relay can detect arc flash via flash sensor,and rapidly trip the circuit breaker when fault occurs. Condenser tripping device (CTD) Arc protection relay and arc flash sensor 04

Secondary Devices Specification of the release Designation Release Rated supply voltage Ua(V) 50/60Hz Range Ua(V) Power consumption Operating DC(W) AC50/60Hz(VA) time F2 closing coil DC 24, 48, 110, 220 / AC 110, 220 85~110% 250 20ms F11/F12 tripping coil DC 24, 48, 110, 220 / AC 110, 220 65~120% 250 20ms F4 undervoltage DC 24, 48, 110, 220 / AC 110, 220 35~0% approx.12 20ms M1 motor charging DC 24, 48, 110, 220 / AC 110, 220 85~110% approx.100 12s Designation Release Rated supply current Ia(A) Range Ia(A) Operating time F3 indirect over current release 0.5, 1.0, 5.0 90~110% 20ms Technical data of the release & auxiliary switch DC(V) AC(V) Rated auxiliary voltage 48 125 220 120 230 Switching capacity (A) 10 3.8 2 10 Time factor T=L/R (ms) 10 20 Rated short-time current 250A/3s Rated continuous current (A) 15 F4 Under voltage release F3 Indirect over current release of closing F12 Secondary tripping coil F11 Tripping coil F2 Closing coil Y1 Blocking coil of closing S2 Auxiliary switch in charging position K01 Anti-pumping relay S12 Auxiliary switch S11 Auxiliary switch in switching position M1 Charging motor Operation counter 05

Dimensions (Bushing Type) Cradle fixing holes Busbar (to be installed by customer himself) Earthing Switch (optional) Cradle Type Voltage (kv) Current (A) A B C D E F G H K P T H12M H12ME H24M H24ME 12 630 / 1250 600 940 210 740 250 390 205 540 550 150 24 630 / 1250 750 1128 268 900 321 457 310 700 700 210 285 350 350 400 unit: mm 06

Wiring Diagrams HVX 12kV/17.5kV/24kV vacuum circuit-breaker withdrawable type with anti-pumping relay K01 The schematic is the largest circuit breaker configuration, according to the ordering requirements, some of the components shown are not included. Storage and distribution circuit breakers in the open state is not used in the working position. Circuit Breaker closing lockout solenoid Y1, press the dotted line an access. Q0 F11 F12 F2 F3 F4 Y1 M1 S11/S12 S2 S6 K01 Secondary components of breaker Tripping coil Secondary tripping coil (option) Closing coil Indirect over current release of closing (option) Under voltage release (option) Blocking coil of closing (option) Charging motor Auxiliary switch in switching position (fault indicator along with control switch control) Auxiliary switch in charging position Micro switch lock solenoid closing (option) Anti-pumping relay Q1 S8 S9 Y0 Secondary components of trolly Used test position indicator switches Used working position indicator switches Used locking solenoid (option) 施耐德電機授權經銷商 東技企業股份有限公司普得企業股份有限公司 總公司 : 台北市內湖區行愛路 68 號 6 樓 電話 :(02)8791-8588 中辦處 :(04)2296-9388 傳真 :(02)8791-9588 高辦處 :(07)227-2133 E-mail:toyotech@ms37.hinet.net 網址 :www.toyotech.com.tw As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Jul. 2018