DIRECT IMMERSION RESISTANCE THERMOMETER CONFIGURATIONS

Similar documents
SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS

Direct immersion resistance thermometer

Spring loaded resistance thermometer

Spring loaded resistance thermometer

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Resistance thermometer Model TR10-E, for additional thermowell

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

ABG Cable Glands Installation Procedure

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

New products Ex Equipment 2015

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Thermocouple with spring-loaded tip Model TC55

Measuring insert for resistance thermometer Model TR10-A

Omnigrad S -TC65. Technical Information

Industrial Pt100 RTD's

Tubeskin thermocouple assembly Model TC59-V

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer Without thermowell Model TR10-H

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

YFC. Limit switch. Ex d. 24 operating head types

INSTRUCTION MANUAL (ATEX / IECEx)

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

INSTRUCTION MANUAL (ATEX / IECEx)

INTERNATIONAL METAL ENGINEERING

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Tubeskin thermocouple assembly Model TC59-W

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

RTD Temperature Sensor omnigrad M TR 15

Tubeskin thermocouple assembly Model TC59-V

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Thermocouple Model TC10-H without thermowell

Emergency Light Fitting for Fluorescent Lamps Series 6009

BETA SWITCHES FOR HAZARDOUS AREA

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

Cable resistance thermometer Model TR40

Thermocouple Without thermowell Model TC10-H

Glass Reinforced Polyester Enclosures

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Linear luminaire with LED Series EXLUX 6002

RTD Temperature Sensor omnigrad M- TR 11

Resistance thermometer Model TR10-B, for additional thermowell

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Control and Terminal Box Type A21-**-*****

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Linear Luminaire with LED Series EXLUX 6002

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Load disconnect switch Series 8146/5-V11

Technical Information Omnigrad TST90, TET90

Cable resistance thermometer Model TR40

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Position Switches Series 8074/2

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6402/2

Thermocouples Model TC10-E, for Additional Thermowell

Mineral Insulated Resistance Thermometers (RTD)

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter

I Ex-safety switches I

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Thermocouple For additional thermowell Model TC10-B

Thermocouple Model TC10-E, for additional thermowell

7 Lighting Technology

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Measuring insert for process resistance thermometer

Cable thermocouple Model TC40

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

LED Linear Luminaire Series EXLUX 6402

RTD Temperature Sensor omnigrad M- TR 13

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Surface thermocouple Model TC50

HTSB system System overview

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Junction box for EKL light

Floodlight LED Series 6125

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Plastic tube variable area flowmeter for liquids and gases

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

M-0. M-0... series control, monitoring and signalling devices. Ex e

Terminal Boxes TNCN. Explosion protection Marking

RTD PT100 Insert With Solid Drilled Flanged Thermowell

Rosemount 68 Sensor and Thermowell

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

Safety switches for hinged doors

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

A good connection. International approvals.

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

Thermocouple Thermometer omnigrad M -TC 12

Terminal Boxes in Stainless Steel SLS**.T

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Cable resistance thermometer Model TR40

Transcription:

DIRECT IMMERSION RESISTANCE THERMOMETER CONFIGURATIONS WELDED THREADED CONNECTION II 1G/D Ex ia Pt100KI D20 D21 D26-1 D26-2 1

FEATURES The industrial thermometer configuration guarantees a short response time. The sensor is directly immersed into the medium. Fully welded construction. All assemblies offer a variety of protection heads to meet environmental and size requirements of most applications. High vibration resistant models available. TECHNICAL SPECIFICATION ASSEMBLY Connection head Aluminium With external earth terminal Ambient temperature range: -40/+100 C IP 6X protection degree (body cover) with oil-proof rubber O-ring, when used with correct cable gland Epoxy finish; colour blue RAL5015 Cover: hinged type or screw type with chain Sensor material: SS321 / 1.4541 Other on request ATEX : code A G=gas D=Dust IECEx : code I G=gas D=Dust Technical specification sensor insert High quality PT100 element with MgO mineral insulated metal sheathed cable, providing excellent stability and reproducibility. The unique properties make this basic element ideally suited for a wide range of applications up to 550 C. The PT100 is bendable over the total length except on the tip over 50 mm. Maximum temperature: 550 C Minimum insulation resistance: 1000 MOhm at 500VDC, ambient Conductors: material Cu Metal sheath: SS321 / 1.4541 Terminal block: -ceramic -hi-tech thermoplast: moisture and shockproof -mounting plate with flying leads Accuracy: according IEC DIN EN 60751: see table below 2

PKA PKB Terminal connection in the head CB RI TI Ceramic block 2/3/4/6/8 terminals Hi-tech thermoplast block 2/3/6 terminals Flying leads standard length 150 mm PT100 element S D Options Single Double HV: High vibration A1 A2 A3 A5 A6 A10 Accuracy Class A Class B 1/3 DIN 1/5 DIN 1/6 DIN 1/10 DIN IEC DIN EN 60751 ±(0.15+0.002 t ) C IEC DIN EN 60751 ±(0.30+0.005 t ) C 1/3 class B 1/5 class B 1/6 class B 1/10 class B Diameter D3 D3.2 D4.5 D4.8 D6 D6.35 3 mm 3.2 mm 4.5 mm 4.8 mm 6 mm 6.35 mm Connection W2 W3 W4 (*) 2 wire 3 wire 4 wire (*) for OD 3/3.2 /4.5/4.8 mm: dual sensors max. 2x3 wire 3

ORDERING INFORMATION PKA Sensor with ½ NPT threaded connection to the connection head PKB Reinforced sensor with ½ NPT threaded connection to the connection head Instrument connection (E) Cable connection Single (SC) Double (DC) P205 P405 P163 Other SC173 SC405 Other on on request G1/2 ½ NPT M18x1.5 M20x1.5 ½ NPT request Code Q410FT Certificates Functional test report (up-down) Q440CR Calibration report 0 C. Q450CR Q460CR Q820CC Q510TR Calibration report on 0 C and 1 up to 4 points in the range of -10/600 C Calibration report by notified body (measuring points to be indicated) Test report EN10204-2.2 Transmitter programming (range and burn-out settings to be indicated) HOW TO ORDER (example) Code Example Your code Style Connection head with insert direct immersion D20 PT100 PT100 type PKA Terminal CB or RI or TI RI Protection A : Atex I : IECEx A Environment G: Gas D: Dust G Single/dual S: Single D: Dual T: Triple S Accuracy Class as per EN 60751 A1 Connection N of wires W3 Diameter OD sensor D6 Diameter OD reinforced part D0 Le length Length in mm below connection head Le200 Extension X Reinforced part under connection head Minimum length: 110 mm X0 4

Process P Connection to the process P405 SC Cable entry connection head SC173 Options Transmitter, cable glands, fitting, others 0rdering code example: D20 PKA RI A G S A1 W3 D6 D0 Le200 X0 P405 SC173 For all options: please contact Rodax Extension length For use in explosive atmosphere, the Temperature classes T6 T1 have to be respected. The table below will help you to choose the minimum extension length between process and connection head) for your application. Please contact us if other lengths are required. TP C TP TP TP TP TP 100 200 300 400 500 600 T6 110 110 110 110 110 150 T5 110 110 110 110 110 110 T4 110 110 110 110 110 110 T3 110 110 110 110 110 110 T2 110 110 110 110 110 110 T1 110 110 110 110 110 110 5