Auxiliary Relay. Type P8n, PQ8n, PN8n

Similar documents
Auxiliary Relay. Type RXP8n, RXPQ8n

Auxiliary Relay. Type CV2

Bistable Relay. Types PSU6n, PSU14n.

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

Bistable Relay. Types PSU6n, PSU14n. Station Automation & Protection. ABB Substation Automation Products

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

Integrated water management solutions

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Distribution transformers Efficiency over life-cycle

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Publication No.: PSG

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Control Relays Overview

MEDIUM VOLTAGE SWITCHGEAR

Reverse power relay and protection assemblies

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Technical Information

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Functions provided by measuring relays in railway equipment

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

3TM Vacuum Contactors

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Motor Protection Circuit Breaker

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

Indoor Metal Clad Switchgear Type:Cubicle VHA 36 SF6 Circuit Breaker HPA 36 Rated Voltage: ABB Power Distribution

Type DTH 31, 32 DTTM 11, 12 High Speed Biased Differential Relays

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Motor-drive mechanism, type BUL. Technical guide

AF series contactors (9 2650)

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

OUTDOOR OFF LOAD DISCONNECTORS HCB/HDB Range

Cobra-S. Catalog Cobra-S

CP Automatic capacitor bank

CI-TI Contactors and motor starters Types CI 61 - CI 98

4.0 OPERATION Type ITH-T Relay

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

MINIATURE CIRCUIT BREAKER

Current accuracy class. Sensor principles

Magnetic Overcurrent Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Magnetic and Hydraulic-Magnetic Circuit Breaker

AF series contactors (9 2650)

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

(Example) In case of DC24 to 48V, it is operating time for DC24V.

SafeGear TM Motor Control Center Arc resistant metal-clad construction

The galvanic separation of the primary or actuating circuit and the load circuits

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Inductive Proximity Sensor

Breaker failure relay REB 010

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

About us. Switchgear Factory, Mumbai

Multi-purpose percentage restraint differential protection

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

Series CA5 Contactors

6R MATRIX. Modular Relays. rms. Auxiliary, Trip & Supervision Relays

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Scheda prodotto Relè Series E

Trip Circuit and Trip coil supervision Relay

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

KD LV Motor Protection Relay

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

PIX-H Metal-clad switchgear up to 17.5kV

Horizontal Circuit Switchers

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

RAPIER DSB Disconnectors

Contactor V-Contact VSC/P

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

F-Series. Circuit Breaker

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Thermal Overcurrent Circuit Breaker 3120-F...

Contactor Types CI 61-98

F-Series. Circuit Breaker

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus

Outdoor vacuum breaker for railway applications - FSK II

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

DC High Speed Circuit Breakers IR2000 IR6000 IR6000MP IR6000ML IRA IR2000SV IR6000SV. DC Switchgears DIACLAD

Transcription:

Auxiliary Relay Type P8n, PQ8n, PN8n

ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering environmental impact. The ABB Group of companies operates in around 100 countries and employs over 1,07,000 people. In India, ABB serves customers with the complete range of power and automation technologies. The company has a vast installed base, extensive manufacturing facilities and a countrywide marketing and service presence. As a part of its Power Technologies offering, ABB serves electric, gas and water utilities as well as industrial and commercial customers with a wide range of products, systems and services for power generation, transmission and distribution. ABB s system offering ranges from Electrical Balance of Plant (EBOP) for power plants, bulk power transmission, turnkey substations and complete electrification to utility automation and power distribution. The product offering covers a wide spectrum of technologies across the entire voltage range including indoor and outdoor circuit breakers, air and gas insulated switchgear, disconnectors, capacitor banks, reactive power compensators, power transformers, distribution transformers, instrument transformers, Compact Secondary Substations (CSS) and Ring Main Units (RMU). Advantage ABB 120 years of technology and innovation Unparalleled domain competence Global experience Complete solution capabilities Large installed base Environment-friendly technologies 2 ABB

Auxiliary relay type P8n, PQ8n, PN8n Features High degree of reliability, even when idle for long periods of time 7 contacts with double-interruption Contact configuration can be changed easily Three mounting variants Wide range of voltage & contact configurations Special versions PQ8n - High speed lock-out relay (86) PN8n - with high drop-off rating Application The auxiliary relays type P8n are used for all kinds of control and protection circuits in power stations and industrial installations, where a high degree of reliability and a high contact rating are stipulated, with minimal internal consumption. Acting as an instantaneous switching element, it provides galvanic separation and contact multiplication in tripping and signalling circuits of protective relays. Design and principle P8n,PN8n and PQ8n are instantaneous, auxiliary, plunger-type relay with 7 contacts and double interruption. They are designed to operate from DC. The relays can operate from AC when preceded by a rectifier. The magnet system comprises of a fixed core and a moving, plunger-type armature, which actuates the contact bar directly. When the coil is de-energized, the armature of the magnet and the contact bar are forced back into their initial position by a spring action. The contacts are arranged symmetrically in two rows, on either side of the magnet, clearly visible and Type designation of auxiliary relays P8n PQ8n PN8n A C H XS 2YS 2JS readily accessible. The contact system is designed for a maximum rated voltage of 250V DC or AC. The material used for the contact tips is hard silver. At the most, 3 normally closed contacts are permissible which should be distributed evenly between two sides. The field weakening resistor is cut by means of a delayed, normally closed contact on a special contact bar in series with the coil. The operation signal pops out and becomes visible when the contact system picks up (type P8nC, PQ8nC) or when the contact system drops off (Type PN8nC). It is reset by pressing the button in. The relay type PN8n is specially designed for minimum drop-out of approximately 20% of the rated voltage. The relay is available with or without drop-off operation indicator. The relay types P8n,PQ8n are designed for high speed operation. PQ8n is specially designed for mechanical latching. It has an operation indicator which pops out when the relay latches. The relay can be reset manually by pressing in and resetting the operation indicator. A transparent protective hood made of burn-proof material readily provides protection against dust. The auxiliary relay mounted in a casing is not provided with a hood. The terminals on the sheet-metal base and 1/2 S flush mounting case have an opening of dia 3.8 mm for external connections. Those of the plug-in sockets can accommodate two wires with a cross-section of 2.5mm 2. The different methods of mounting are illustrated in (Figs. 4-6). The auxiliary relays should always be mounted with the contact bar in horizontal position. A method of mounting that is ideal for installation and servicing is the plug-in mounting. Guide pins prevent the relay from being plugged in the wrong way. The marking of the terminals on the base agrees with that of their relay contacts. Basic auxiliary relay with high-speed operation with mechanical latching with high drop-out rating without operation indicator with operation indicator with field weakening resistor with plug-in base with sheet-metal base with 1/2 S size, flush mounting case Example: P8nAH2YS denotes a P type auxiliary high speed relay with 7 free contacts, without operation indicator, with field weakening resistor mounted on sheet-metal base. Available types: P8nAHXS, P8nAH2YS, P8nCH2JS, PN8nAH2YS, PQ8nCH2JS, PN8nCH2JS. ABB 3

Technical data Rated voltage (U N ) 24, 30, 48, 110, 125, 220, 250 DC 110,240 AC (with Rectifier) available only in ½ S size mounting case Operating range Type P8n..., PN8n... ;- 20% to +10% of U N Type PQ8n... ;- 30% to +10% of U N Frequency 50 Hz +/-5% P8n... PN8n... PQ8n... Pick-up voltage (%U N ) < 80% <80% <70% Drop-off voltage (%U N ) > 4% > 20% NA Pick-up time at U N (typical) max.16 ms 20-30ms max.16ms Maximum power consumption DC; 9.0W 6.3W 9.0W AC; 7.5VA 5.5 VA 7.5 VA Mechanical life 5 x 10 6 5 x 10 6 1 x 10 4 Switching rate Up to 500 times per hour at full breaking current, or 5000 times per hour with reduced breaking current. Contacts Rated voltage 250V DC/AC Rated current 5 A Max. making current 50 A, 0.5 sec, Max. Breaking capacities Voltage 24V 48V 110V 250V Contacts 1 2 in 1 2 in 1 2 in 1 2 in 2 in parallel parallel parallel parallel series DC resistive load 5A 10A 5A 10A 5A 7A 1A - 5A DC inductive. L/R =15ms 5A 10 A 5 A 8 A 4 A - 1 A - 4 A DC inductive, L/R =40ms 4 A 8 A 4 A 8 A 3 A - 0.5A - 2 A AC resistive & inductive 10 A - 10 A - 10 A - 10A - - Insulation tests Dielectric test 2kV, 50Hz, 1min. as per IEC 60255-5 Impulse voltage test 5kV,1.2/50µs. 0.5J., as per IEC 60255-5 Insulation resistance >100 M ohms at 500V DC. as per IEC 60255-5 Environment tests Dry heat test Dry cold test Damp heat cyclic test Storage test Vibrations test Vibration response Endurance test IEC 60068-2-2 +55 o C and +70 o C IEC 60068-2-1-10 o C and -25 o C IEC 60068-2-30 12hrs+12hrs cycle at+55 o C / +25 o C with RH98% for 6days IEC 60068-2-8 +70 o C for 72hrs and -25 o C for 72 hrs. IEC 60255-21-1 Class-1 10-150Hz, 0.5g, 3 axis IEC 60255-21-1 Class-1 10-150Hz, 1.0g, 3 axis Shock and Bump test (flush mounting case) Shock response test IEC 60255-22-2 Class-2 10g,11 ms Shock withstand test IEC 60255-22-2 Class-1 15g,11 ms Bump test IEC 60255-22-2 Class-1 10g,16 ms Weight: Type...XS Type...2YS Type...2JS 0.80 Kg. Approx 0.75 Kg. Approx. 0.95 Kg. Approx. 4 ABB

Connection diagram and contact configuration Fig. 1- Relay on plug-in base mounting for dc voltage Fig. 2 - Relay in 1/2 'S' case mounting or on sheet-metal base mounting for dc voltage Fig. 3 - Relay for ac voltage in 1/2 'S' case mounting ABB 5

Dimensions Fig.4 Plug-in base mounting Fig. 5 1/2 S case mounting. Fig 6. Sheet-metal base mounting.

Ordering details Refer type designation for selection and tick appropriate boxes Type : P8nAH2YS Qty... Item no... P8nAHXS Qty... Item no... Aux Voltage : 24VDC Contacts 7N/O + 0N/C 30VDC 6N/O + 1N/C 48VDC 5N/O + 2N/C 110VDC 4N/O + 3N/C 125VDC 220VDC 250VDC Type : PN8nAH2YS Qty... Item no... Aux Voltage : 24VDC Contacts 7N/O + 0N/C 30VDC 6N/O + 1N/C 48VDC 5N/O + 2N/C 110VDC 4N/O + 3N/C 220VDC Type : P8nCH2JS Qty... Item no... PN8nCH2JS Qty... Item no... PQ8nCH2JS Qty... Item no... Aux Voltage : 24VDC Contacts 7N/O + 0N/C 30VDC 6N/O + 1N/C 48VDC 5N/O + 2N/C 110VDC 4N/O + 3N/C 125VDC 220VDC 250VDC 110VAC 240VAC

1MDB08202 -YN 08-2006 ABB Limited Distribution Automation Maneja, Vadodara 390 013, India. Tel: +91 265 2604384/5/6 +91 265 2604397 Fax: +91 265 2638922 E-mail: aicds@in.abb.com Regional Marketing Offices: North NBCC Tower 4th Floor No. 15, Bhikaji Cama Place New Delhi 110 066 Tel: +91 11 26186000 Fax: +91 11 26197592/84035 West ABB House Dr. S B Path Ballard Estate Mumbai 400 038 Tel: +91 22 56318231 39 Fax: +91 22 56318276/77 South Embassy Star, 1st Floor No. 8, Palace Road Vasanth Nagar Bangalore 560 052 Tel: +91 80 22949779 Fax: +91 80 22949808 www.abb.co.in East 4th Floor No. 9 Elgin Road Kolkata 700 020 Tel: +91 33 22832906/8 Fax: +91 33 22832990 Central 4th & 5th Floor, Maruti Heights Aamanaka, G E Road, Raipur 492 099 Tel: +91 771 4701016 Century Plaza No. 3C, 3D & 3F, 3rd Floor 561 / 562, Anna Salai Teynampet (Mount Road) Chennai 600 018 Tel: +91 44 24340201 Fax: +91 44 24340282