FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Similar documents
Advanced Test Equipment Rentals ATEC (2832)

Ground Resistance Tester Model 3620 & 3620 Kits

Multi-Function Ground Resistance Tester Model 6472

For all of your Ground T esting needs. Technical Hotline: (800) Ground Testers

Digital/Analog Megohmmeter Model 1026

Digital Insulation Resistance Testers. you can depend on

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

USER MANUAL. Insulation Tester + DMM. Model MG320

OPERATING INSTRUCTION

4-WIRE EARTH RESISTANCE TESTER C1 ES P1 S. Max. AC 200V MICROPROCESSOR CONTROLLED TEST. Switch ON, TEST, SCROLL RESULTS 20Ω 200Ω 2000Ω OFF

Digital/Analog Megohmmeter Model 1026 USER MANUAL

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

2-Color Display High-Precision Digital Pressure Switch

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Model Insulation Tester / Megohmmeter. User Manual

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

5.2 PRE-OPERATION PROCEDURE WARRANTY

2-Color Display High-Precision Digital Pressure Switch

Model Pressure range ON/OFF output Linear output

PAT120, PAT150 and PAT150R

SafetyPAT Plus A B P/N:

OPERATING INSTRUCTION

Switching DC Power Supply

DIGITAL RCD(ELCB) TESTER

DIGITAL MULTIMETER INSTRUCTION MANUAL

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Selectable Impedance Adapter

Surface mounting, flush mounting, and DIN track mounting

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES

Declaration of Conformity

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

KEWTECH. KT56 digital multi function tester. Instruction manual

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

S1-568, S1-1068, S1-1568

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

MIT515, MIT525, MIT1025, MIT1525

EPS/ELA-Series User Manual EPS/ELA 250W

User Guide. Model Insulation Tester / Megohmmeter

DLRO10HDX 10 Amp Digital Low Resistance

AC CURRENT ANALOG CLAMP-ON TESTER MODEL MCL-350 INSTRUCTION MANUAL

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

Weatherproof Tubular Slip Ring Assembly

User Guide. Model Insulation Tester / Megohmmeter

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

OPERATING INSTRUCTION

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Model Number Structure

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Series 10-ZSE40A(F)/10-ISE40A

COMPONENT-TESTER INSTRUCTION MANUAL

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

Autoranging Industrial Multimeter

Autoranging Multimeter

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

LED Driver Linear / area fixed output

User's Manual. Earth Ground Resistance Tester. Model Introduction

Digital display Pressure range ON/OFF output Linear output Model

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

Power Controller. (see note 1) 10 sec

DC POWER SUPPLY ALIMENTATION C.C.

Clamp Earth Tester MET-2. Instruction Manual

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

Table of Contents Title Page No.

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

MEGOHMMETER. User Manual

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

True RMS Autoranging Multimeter

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

Switching Power Supply

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

KTD30 Digital Insulation and Continuity Tester. User Manual. kewtechcorp.com

Scheda prodotto Relè Series E

Digital Multimeter User's Manual

Dawson DDM190D. Digital Multimeter User s Manual

HD110C Heavy-Duty Digital Multimeter

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

User's Manual Digital High Voltage Insulation Tester Model

Digital Transformer Ratiometer

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

3 PHASE TESTER & MOTOR ROTATION TESTER

BM kv Digital Insulation Tester USER MANUAL

1.Safe testing IMPORTANT:

FE100/FE200. Inverter

ABB component drives ACS150, 0.5 to 5 Hp

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

90HJRKPPHWHU 0RGHO1 (6'&RQGX WLYLW\7HVW.LW

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Non-Contact Phase Rotation Tester

Transcription:

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER Models 3620, 3640 & 4610 Call toll free (800) 537-0351 or visit www.allspec.com Measures soil resistivity (4-Point) (Model 4610) Measures ground resistance (2- and 3-Point) Fall-of-Potential Method Large analog display (Model 3620) Large LCD digital display (Models 3640 and 4610) Designed to reject high levels of noise and interference Auto-Ranging: automatically selects the optimum range (Models 3640 and 4610) Battery powered Extremely simple to operate: connect press read Indicator error lights Rugged dustproof and rainproof case Color-coded terminals and lead identification

Ground Resistance Tester Model 3620 & 3620 Kit Model 3620 Kit The Analog Ground Resistance Tester Model 3620 performs ground resistance measurements from 0.5 to 1000Ω with speed and accuracy. The Model 3620 features three-terminal operation for Fall-of-Potential earth/ ground resistance and also may be used for 2-Point tests. The large 3.1" logarithmic analog scale is easy- to-read, with a separate marking for 25Ω.Alarge Press-to-Measure button allows for easy measurements. A manual zero adjust is provided for accurate readings. Color-coded binding post terminals are easy-to-use with banana plug and spade lug inputs. The heavy duty ABS case is O-ring sealed against dust and water, and the Press-to-Measure button is also sealed. The Ground Tester Model 3620 is battery powered, for convenient use in remote field applications. Mechanical and safety specifications, such as vibration and drop test, meet or exceed IEC standards, to ensure safe and reliable field use. The Ground Resistance Tester Model 3620 is the ideal instrument for electrical contractors, power utilities, REAs, telephone and CATV technicians, and inspectors who must check ground to determine compliance with NEC, OSHA and other specifications. The Model 3620 kit includes meter, one 16 ft lead, two 150 ft leads on reels with wind-up handles, two 16" auxiliary ground electrodes, soft carrying case, batteries and user manual. FEATURES Measures ground resistance (2- and 3-Point) Fall-of-Potential Method Direct reading on large analog display 0.5 to 1000Ω and easy 25Ω readings Large 3.1" (77mm), analog display for accurate readings Built-in battery check Color-coded terminals and lead identification Large Press-to-Measure button Portable and compact Extremely simple to operate: connect press read Designed to reject high levels of noise and interference APPLICATIONS Measuring earth resistance of the type of single rod or small ground grids often found in remote telecommunication switching sites Measuring ground electrode resistance of lightning protection equipment Measuring the earth electrode resistance of equipment in recreational areas Testing electrode resistance of ground rods and grids at new construction sites, when utility supplied power has not been supplied Testing earth electrode resistance of grounded towers at cellular phone remote installations 2

SPECIFICATIONS MODEL 3620 ELECTRICAL Range 0.5 to 1000Ω Resolution 10mΩ Resistance Measurement Frequency 128Hz square wave Test Current 10mA Accuracy ±5% of Reading + 0.1% of galvanometer scale length Auxiliary Electrode Influence Rz 3000 times the reading up to 50kΩ Ry 50kΩ Withstanding Voltage 250Vrms with spikes of 3000VAC or 1000VDC Power Source Eight 1.5V AA Alkaline batteries Battery Life 1680 15-second tests (approximately) Fuse Protection High breaking capacity 0.1A, 250V, 0.25 x 1.25" MECHANICAL Display Analog Pivot movement Connection Color-coded terminals accept spade lugs with minimum gap of 6mm or standard 4mm banana jacks Scale 3.1" (77mm) white scale with black pointer; one scale per range Operating Temperature 14 to 131 F (-10 to 55 C) Storage Temperature -40 to 158 F (-40 to 70 C), 0 to 90% RH with batteries removed Temperature Influence 5% per 10 C Relative Humidity 20 to 90% maximum Dimensions 8.7 x 5.4 x 5.9" (220 x 136 x 150mm) Weight 2 lbs (1.3kg) Case Heavy-duty, ABS Colors Case safety yellow; Front panel gray Mechanical Shock IEC 68-2-27 Vibration Test IEC 68-2-6 Drop Test IEC 68-2-32 Environmental O-ring sealed against dust and water to IP50 SAFETY Rating EN 61010-1, Cat. III, Pollution Degree 2, 24V Double Insulation Agency Approval Emission: EN 50081-1 Immunity: EN 50082-1 CE Mark

Ground Resistance Tester Model 3640 & 3640 Kit Model 3640 Kit The Digital Ground Resistance Tester Model 3640 performs ground resistance measurement. This direct reading tester measures from 10mΩ to 1999Ω and is Auto-Ranging, so it automatically seeks out the optimum measurement range. Easy-to-use simply connect the leads, Press-to-Measure and read. The large LCD (nearly 3 /4" high) is easy-to-read, and also indicates low battery status, overrange and lead reversals. The Model 3640 comes with three color-coded terminals to aid in easy hookup. Three LED indicators on the front panel continuously warn the user of any measurement problems to ensure accurate and reliable tests. The Model 3640 is fuse protected up to 250V AC to protect the instrument against voltage into the test leads. In the event of a system fault, it can withstand 250VAC with spikes of 3000VAC or 1000VDC. The heavy duty ABS case is O-ring sealed against dust and water and the Press-to-Measure button is also sealed. Model 3640 is battery powered, for convenient use in remote field applications. Mechanical and safety specifications, such as vibration and drop test, meet or exceed IEC standards, to ensure safe and reliable field use. Ground Resistance Tester Model 3640 is a rugged, easy-to-use instrument ideal for maintenance crews performing numerous tests. The Model 3640 is designed to reject high levels of interference, therefore it can be used under difficult conditions such as high stray currents that normally affect measurement accuracy. The Ground Resistance Tester Model 3640 kit includes one 16 ft lead, two 150 ft leads on reels with wind-up handles, two 16" auxiliary ground electrodes, soft carrying case, batteries and user manual. FEATURES Fall-of-Potential method Measures ground resistance (2- and 3-Point) Auto-Ranging: automatically selects the optimum range Designed to reject high levels of noise and interference Extremely simple to operate: connect press read LED on faceplate informs operator of high input noise, high auxiliary rod resistance and fault connections Battery powered Rugged dustproof and rainproof field case Color-coded terminals May also be used for continuity tests on bonding APPLICATIONS Three-point measurements for measuring resistance to ground of ground rods and grids. Three-point measurements are generally used when the electrode or grid is easily disconnected, if corrosion is suspected, or where ground faults are unlikely to occur. Two-point tests for continuity tests on bonding or on pre-established grounds. This test is commonly performed in urban environments where proper auxiliary electrode placement may be obscured by confined real estate. Measurements are referenced against a good local ground conductor.

SPECIFICATIONS MODEL 3640 ELECTRICAL Range (Auto-Ranging 0 to 2000Ω) 20Ω 200Ω 2000Ω Measurement 0.00 to 19.99Ω 20.0 to 199.9Ω 200 to 1999Ω Resolution 10mΩ 100mΩ 1Ω Open Voltage 42V peak Resistance Measurement Frequency 128Hz square wave Test Current 10mA 1mA 0.1mA Accuracy ±2% of Reading + 1ct ±2% of Reading + 1ct ±3% of Reading + 3cts Auxiliary Electrode Influence Range 20Ω 3kΩ 50kΩ Current Circuit 200Ω 30kΩ 50kΩ Voltage Circuit 2000Ω 50kΩ 50kΩ Interference Rejects high levels of interference voltage (DC, 50/60Hz, harmonics) DC voltage in series with X 20VAC voltage in series with Y 13V peak AC voltage in series with Z 32V peak Response Time Approximately six seconds for a stabilized measurement Withstanding Voltage 50VAC with spikes of 3000VAC or 1000VDC Power Source Eight 1.5V AA batteries; Alkaline recommended; LO BAT indication on LCD Battery Life 1800 15-second measurements (approximate) Fuse Protection High breaking capacity 0.1A, 250V, 0.25 x 1.25" MECHANICAL Display 7-segment LCD, 0.71" (18mm) high (3 1 /2 digit); 2000-counts; LCD also indicates overrange, test lead shorts and lead reversals Connection Color-coded terminals accept spade lugs with min. gap of 6mm or standard 4mm banana jacks LED Indication Three LEDs indicate high input noise, high auxiliary rod resistance, open leads, blown fuse Operating Temperature 14 to 131 F (-10 to 55 C), 0 to 90% RH Storage Temperature -40 to 158 F (-40 to 70 C), 0 to 90% RH with batteries removed Dimensions 8.7 x 5.4 x 5.9" (220 x 136 x 150mm) Weight 2.9 lbs (1.3kg) Case Heavy-duty ABS Colors Case safety yellow; Front panel gray Mechanical Shock IEC 68-2-27 Vibration Test IEC 68-2-66 Drop Test IEC 68-2-32 Dielectric Test 3kV, 50/60Hz, one min. between four interconnected measuring terminals and any external metal ground Environmental O-ring sealed against dust and water to IP50 (Protection Index) Electrostatic IEC 801-2 Electromagnetic IEC 801-3 Electric Shock IEC 801-5 SAFETY Rating EN 61010-1, Cat III., Pollution Degree 2, 42V Double Insulation Agency Approval Emission (EN 50081-1) Immunity (EN 50082-1) CE Mark Accuracies and specifications are given for an ambient temperature of 23 C ± 3 K, RH of 45 to 55%, battery power at 8V, auxiliary resistance at the measurement terminals <200Ω, no stray voltage and a magnetic field from 0 to 40Å/m.

Ground Resistance Tester Model 4610 & 4610 Kit Model 4610 Kit Digital Ground Resistance Tester Model 4610 performs ground resistance and soil resistivity tests. Direct reading tester measures from 10mΩ to 1999Ω, and is Auto-Ranging, so it automatically seeks out the optimum measurement range. Easy-to-use simply connect the leads, Press-to-Measure and read. The large LCD (nearly 3 /4" high) is easy-to-read, and also indicates low battery status, overrange, and test lead shorts and lead reversals. Three LED indicators on the front panel continuously warn the user of measurement problems to ensure accurate and reliable tests. The Model 4610 is fuse protected up to 250V AC against Accidental connection to live circuits. In the event of a system fault, it can withstand 250VAC with spikes of 3000VAC or 1000VDC. The heavy duty ABS case is O-ring sealed against dust and water and the Press-to-Measure button is also sealed. Model 4610 is battery powered for convenient use in remote field applications. Mechanical and safety specifications, such as vibration and drop test, meet or exceed IEC standards, to ensure safe and reliable field use. The Ground Resistance Tester Model 4610 is a rugged, easy-to-use instrument ideal for maintenance crews performing numerous tests. The Model 4610 is designed to reject high levels of interference, so it can be used under difficult conditions such as high stray currents that normally affect accuracy. The Ground Resistance Tester Model 4610 kit includes meter, one 16 ft color-coded lead, two 100 ft color-coded leads, two 300 ft leads on reels, four 16" auxiliary ground electrodes, soft carrying case, batteries and user manual. FEATURES Fall-of-Potential method Measures ground resistance (2- and 3-Point) and soil resistivity (4-Point) Step voltage tests and touch potential measurements Auto-Ranging: automatically selects the optimum range Designed to reject high levels of noise and interference Extremely simple to operate: connect press read LED on faceplate informs operator of high input noise, high auxiliary rod resistance and fault connections Battery powered Rugged dustproof and rainproof field case May be used also for continuity tests on bonding Color-coded terminals APPLICATIONS Three-point measurements of resistance to ground of ground rods and grids. Three-point measurements are generally used when the electrode or grid can be easily disconnected, if corrosion is suspected, or in circumstances where ground faults are unlikely to occur. Four-point tests, or soil resistivity measurements. Locating areas of lowest soil resistivity is essential for achieving an economical grounding installation. Touch potential measurements, an alternative to 3-Point tests in evaluating electrical safety. This test is recommended when the ground cannot be disconnected, where ground faults are highly likely to occur, or when the footprint of grounded equipment (the outline of the part of equipment in contact with the earth) is comparable to the size of the ground to be tested. Two-point tests for continuity tests on bonding or on pre-established grounds. This test is commonly performed in urban environments where proper auxiliary electrode placement may be obscured by confined real estate. Measurements are referenced against a good local ground conductor.

SPECIFICATIONS MODEL 4610 ELECTRICAL Ranges (Auto-Ranging 0 to 2000Ω) 20Ω 200Ω 2000Ω Measurement 0.00 to 19.99Ω 20.0 to 199.9Ω 200 to 1999Ω Resolution 10mΩ 100mΩ 1Ω Open Voltage 42V peak 42V peak 42V peak Resistance Measurement Frequency 128Hz square wave 128Hz square wave 128Hz square wave Test Current 10mA 1mA 0.1mA Accuracy ±2% of Reading + 1ct ±2% of Reading + 1ct ±3% of Reading + 3cts Auxiliary Electrode Influence Range 20Ω 3kΩ 50kΩ Current Circuit 200Ω 30kΩ 50kΩ Voltage Circuit 2000Ω 50kΩ 50kΩ Interference Model 4610 rejects high levels of interference voltage (DC, 50 to 60Hz, harmonics): DC voltage in series with X: 20V; AC voltage in series with Y: 13V peak; AC voltage in series with Z: 32V peak Response Time Approximately six seconds for a stabilized measurement Withstanding Voltage 250VAC with spikes of 3000VAC or 1000VDC Power Source Eight 1.5V AA batteries; Alkaline recommended; LO BAT indication on LCD Battery Life 1800 15-second measurements Fuse Protection High breaking capacity 0.1A, 250V, 0.25 x 1.25" MECHANICAL Display 7-segment LCD, 0.71" (18mm) high (3 1 /2 digit); 2000-counts; LCD also indicates overrange, test lead shorts and lead reversals Connection Color-coded terminals accept spade lugs with min. gap of 6mm or standard 4mm banana jacks LED Indication Three LEDs indicate high input noise, high auxiliary rod resistance, open leads, blown fuse Operating Temperature 14 to 131 F (-10 to 55 C), 0 to 90% RH Storage Temperature -40 to 158 F (-40 to 70 C), 0 to 90% RH with batteries removed Dimensions 8.7 x 5.4 x 5.9" (220 x 136 x 150mm) Weight 2.9 lbs (1.3kg) Case Heavy-duty ABS Colors Case: safety yellow; Front panel: gray Mechanical Shock IEC 68-2-27 Vibration Test IEC 68-2-66 Drop Test IEC 68-2-32 Dielectric Test 3kV, 50/60Hz, one min. between four interconnected measuring terminals and any external metal ground Environmental O-ring sealed against dust and water to IP50 (Protection Index) Electrostatic IEC 801-2 Electromagnetic IEC 801-3 Electric Shock IEC 801-5 SAFETY Rating EN 61010-1, Cat. III, Pollution Degree 2, 42V Double Insulation Agency Approval Emission (EN 50081-1); Immunity (EN 50082-1) CE Mark Accuracies and specifications are given for an ambient temperature of 23 C ± 3 K, RH of 45 to 55%, battery power at 8V, auxiliary resistance at the measurement terminals <200Ω, no stray voltage and a magnetic field from 0 to 40Å/m.

CONSTRUCTION Input terminals Press-to-Measure button LED measurement fault indicators: X-Z Fault X-Y Hi Resistance X-Y Hi Noise Analog Display Zero adjustment screw Model 3620 Input terminals Press-to-Measure button LED measurement fault indicators: X-Z Fault Xv-Y Hi Resistance Xv-Y Hi Noise Large LCD with low battery indicator Model 3640 Input terminals Press-to-Measure button LED measurement fault indicators: X-Z Fault Xv-Y Hi Resistance Xv-Y Hi Noise Large LCD with low battery indicator Model 4610

ACCESSORIES Ground Test Kit 3-Point (supplemental 4-Point) includes carrying bag, two 100 ft color-coded leads, one 16 ft lead and two 16" auxiliary ground electrodes Catalog No. 2130.62 Ground Test Kit for 3-Point testing (supplemental for 4-Point testing) includes carrying bag, two 100 ft color-coded leads, one 16 ft lead and two 16" auxiliary ground electrodes Catalog No. 2130.61 Ground Test Kit for 4-Point testing includes carrying bag, two 300 ft color-coded leads on spools, two 100 ft color-coded leads, four 16" auxiliary ground electrodes, one 16 ft lead with Mueller clip and one 100 ft tape measure Catalog No. 2130.63 ORDERING INFORMATION CATALOG NO. Ground Resistance Tester Model 3620 (3-Point Analog)....................................................... Cat. #2114.90 Includes soft carrying case, batteries and user manual Ground Resistance Tester Model 3640 (3-Point Digital)....................................................... Cat. #2114.92 Includes soft carrying case, batteries and user manual Ground Resistance Tester Model 4610 (4-Point Digital)....................................................... Cat. #2114.94 Includes soft carrying case, batteries and user manual Ground Resistance Tester Model 3620 Kit.................................................................. Cat. #2114.91 Includes meter, one 16 ft lead, two 150 ft leads on reels with wind-up handles, two 16" auxiliary ground electrodes, soft carrying case, batteries and user manual Ground Resistance Tester Model 3640 Kit.................................................................. Cat. #2114.93 Includes meter, one 16 ft lead, two 150 ft leads on reels with wind-up handles, two 16" auxiliary ground electrodes, soft carrying case, batteries and user manual Ground Resistance Tester Model 4610 Kit.................................................................. Cat. #2114.95 Includes meter, one 16 ft color-coded lead, two 100 ft color-coded leads, two 300 ft leads on reels, four 16" auxiliary ground electrodes, soft carrying case, batteries and user manual Accessories (Optional) Tape Measure (100 ft).................................................................................... Cat. #2130.60 Ground Test Kit for 3-Point testing (supplemental for 4-Point testing) includes carrying bag, two 100 ft color-coded leads, one 16 ft lead and two 16" auxiliary ground electrodes.......................................................... Cat. #2130.61 Ground Test Kit 3-Point (supplemental 4-Point) includes carrying bag, two 100 ft color-coded leads, one 16 ft lead and two 16" auxiliary ground electrodes.......................................................... Cat. #2130.62 Ground Test Kit for 4-Point testing includes carrying bag, two 300 ft color-coded leads on spools, two 100 ft color-coded leads, four 16" auxiliary ground electrodes, one 16 ft lead with Mueller clip and one 100 ft tape measure................ Cat. #2130.63