Installation Instructions

Similar documents
Lint Slide Grid Moist Air Applicator

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

RAMMER BT1400, BT1600 PARTS BOOK

RAMMER BT1000 PARTS BOOK

COBRA Model # - D X, D X, D-20109, D-20209, D-20409, D20609, D-20809, D-21015, D-20119, D Cobra Series- Instruction Manual V.

Dynojet Research, Inc. All Rights Reserved. Tire Temperature Sensor Installation Guide

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE

AQA GCSE Design and Technology 8552

UNISTEER Performance Products UNIVERSAL HOT ROD ELECTRA-STEER KIT

APOLLO Model # - F-12013, F-22013, D-50115, D-50215, D-50415, D-50615, D-50815, D Apollo Series- Instruction Manual V.3

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

2 TONNE TROLLEY JACK

AQA GCSE Design and Technology 8552

Rechargeable Inflator

System 3 ZB1PS Device Chassis. Operator s Manual

THIS BULLETIN APPLIES TO VEHICLES EQUIPPED WITH A GASOLINE ENGINE.

RECHARGE STATION OPERATION MANUAL. Version

Virtual Pipeline FSM Parts Manual

COMPONENT WORK SAMPLE 14 Integrated Peer Performance MAINTENANCE MANUAL

The information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini.

BOSTON TOWER MERCHANDISER ILLUMINATION KIT (P/N ) INSTALLATION INSTRUCTIONS

Assembly Instructions Signature Choral Riser 3-Step Model

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

Installation, Operation & Maintenance Supplement Instruction. Bulletin No.: IOMS-PUL PULSA Series 7120V DRIVE MOTOR INSTALLATION

THE SOFTWARE WILL BE AVAILABLE ON TechCONNECT ON FEBRUARY 3, 2004.

FENIEX ROCKER PANEL Series MODEL # D-11971

ANTI-SYPHON VALVE INSTALLATION GUIDE

2013 IMPCO Technologies, Inc. Page 1 of 20 EPR Repair Kit Instructions (PPI-122, Rev-B)

TRAILER INSTALLATION INSTRUCTIONS

JEEP JK MANUAL SHIFT 1 1/4 2 / 4 DOOR BODY LIFT

Installation, Operation and Maintenance Manual

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Pneumatic Actuator. Operation & Service Manual. Models: Original Instructions UNIBLOC PUMP MANUAL NO.: REVISION: 08/2016

PMA INTAKE FILTER SCREEN INSTALLATION GUIDE

There are different steps for GMC and Chevrolet trucks in this instruction sheet.

SB2 TubBuddy Owners Manual. elimination through innovation

SUBJECT: Long Engine Crank Time And/Or MIL Illumination Due To DTC P0340 / P0344

MORTAR AND PLASTER MIXER

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

99-04 Ford F250 Super Duty 4-6 Suspension Kit

FUSION Model # - FN-XXXX, *See website for Part # Fusion Innerbar. Instruction Manual V2.0

B3 Bypass Step by Step Installation Guide

Battery Capacity Analyzer

580RK SERVICE GUIDELINES For coupling models: 580 & 580J

Declaration of Conformity

SYMPTOM/CONDITION: The Service 4WD lamp is illuminated even though the truck is not a 4X4 vehicle.

THE DRBIII FLASH FILES FOR THIS BULLETIN ARE AVAILABLE ON DealerCONNECT.

04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Solar-Powered Battery Bank

Universal Splice Tray Installation Instructions

MODEL 11A REGULATOR

DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE

2006 Dynojet Research, Inc. All Rights Reserved. Spring Applied Air Release (SAAR) Brake Assembly Installation

GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472

INSTALLATION INSTRUCTIONS

Do-It-Yourself Battery Pack

Stealth Power i-tilt

USER MANUAL QUICK INSTALLATION GUIDE MRGB65B

OWNERS MANUAL. Model No LB. TOW SPIKER SPREADER. CAUTION: Read Rules for Safe Operation and Instructions Carefully

Universal Deck & Rail Cart

Mazda North American Operations Irvine, CA MULTI-MODEL - BATTERY TEST PROCEDURE REQUIREMENTS USING THE GR BULLETIN NOTE

RU SERIES UPGRADE TempAssure Compatible

Illustrated Parts List 9J900

SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4

FAN POWERED HEPA FILTER UNIT

Ford F150 2 Suspension Kit

Music Stands CONTENTS. Assembly and Owner s Manual. Note: Note:

PISTOL SHAPE SPOTLIGHT 500,000 CANDLE POWER ASSEMBLY & OPERATING INSTRUCTIONS Mission Oaks Blvd., Camarillo, CA 93011

On-Vehicle Service Hub and Drum Assembly. Remove or Disconnect (Figures 1, 3-5) 1 of 8 11/25/2016 2:47 PM

STR-Series Indirect-Fired Air Turnover Units

SA Series Robot Instruction Manual

RIGID ENTRY BOOT INSTALLATION GUIDE

NOTE: This bulletin applies to vehicles within the following markets/countries: NAFTA.

Rental Industry Safety Tester Safe Check 5s

3 TONNE TROLLEY JACK

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

LIGHTNING PROTECTION UNIT (LPU)

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

YOGEV. Hydro-Power Unit. Installation and Operation Guide

RDC 100 & RDC DRUM ROTATING CARTS ASSEMBLY INSTRUCTIONS

Gen 1 CNG Frame Mount FSM Parts Manual

THIS BULLETIN IS BEING PROVIDED IN ADVANCE. THE SOFTWARE WILL BE AVAILABLE ON TechCONNECT ON OR AFTER DECEMBER 15, 2003.

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

CONTAINER LOCK SATLOCK V3.0 PRODUCT OVERVIEW

Back-Up Sensor System

OVERVIEW: This bulletin involves selectively erasing and reprogramming the Powertrain Control Module (PCM) with new software.

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Installation Instructions

Transceiver Voltage Conditioner

THE DRBIII FLASH FILES FOR THIS BULLETIN ARE AVAILABLE ON DealerCONNECT.

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

B32207 UNDERCARRIAGE KIT. Parts List and Installation Instructions CAUTION. Read this document before installing the snowplow.

INSTRUCTIONS FOR M.O.R.E STEERING CORRECTION KIT PLEASE READ TERMS AND POLICIES ON PAGE 3 OF THESE INSTRUCTIONS

Toro Sprayer Calibration Tool

Rev. 10/27/2015 CDL-2000, MANUAL

INSTALLATION INSTRUCTIONS FOR M.O.R.E. SHACKLE REVERSAL SYSTEM (S.R.S. ) PART # THIS SYSTEM FITS Jeep CJ-5, CJ-7, CJ-8 VEHICLES.

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

Transcription:

Installation Instructions GLOBAL POWER PRODUCTS 225 Arnold Road Lawrenceville, GA 30044 Phone: 770.736.8232 www.generlink.com www.globalpowerproducts.com Installation Instructions Model MA23/24 - N/S Designed to fit most 200 Ampere Ring or Ring-Less meter cans. This version has been configured for installation in a four-jaw meter can. Please read these instructions carefully before beginning the installation.

Step 3 Install the meter and secure with a locking ring. Copyright 2004 by Global Power Products, Inc. All rights reserved No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or by an information storage or retrieval system without the prior written permission of Global Power Products unless such copying is expressly permitted by federal copyright law. Address inquiries to: Global Power Products 225 Arnold Road Lawrenceville, GA 30044 www.generlink.com GenerLink has been thoroughly tested and has been found to be in compliance with the National Electrical Safety Code as it applies to utility control equipment. For additional information, contact: Technical Support, Global Power Products, Inc 770-736- 8232.

Step 2 Install the Neutral/Ground lead connection from GenerLink. Depending on the type of meter can, either a #6/#8 Hi-lug or a split-nut ground connection should be used. The grounding method selected should be consistent with local codes and standards for your area. NOTICE The license label, shown below, is not to be removed during installation. This label has been attached to GenerLink and should only be removed by the homeowner. NOTICE By breaking this seal, you agree to the following: You will not attempt to remove, repair, or in any way modify this GenerLink unit. Step 2a Hi-Lug Ground Installation Step 2b Split-nut Ground Installation You will allow authorized utility representatives to access this GenerLink unit as determined by them to be necessary. You accept and agree to all Terms and Conditions set forth in the Operating Manual relating to GenerLink. Step 3 Connect the neutral/ground leads together. Insert GenerLink by carefully aligning with the jaws of the meter can and pushing the blades firmly into the jaws. Check for normal utility presence with the indicator lights on GenerLink. For normal utility presence, the green light is illuminated with or without the yellow light. Secure GenerLink with a locking ring. If you do not accept the Terms and Conditions do not break this seal and follow the instructions in the Operating Manual to arrange for removal of the GenerLink. L001A DANGER 240-Volt potential exists across the top jaws when GenerLink is installed in a meter can. BEFORE YOU START To perform this installation you will need the following tools and fasteners: #6 / #8 Hi-lugs or Split Nuts (For attaching Ground) Socket Set

NOTICE The warranty on GenerLink is null and void should the device be opened, dismantled, modified, altered, or changed in any way during installation, normal operation or removal. Section 2 - Installation in Ring-Style Meter Cans Installation of GenerLink is fast and easy. For installations in ring style cans, the procedure (shown in Figure 1) is as follows: The warranty is also null and void should GenerLink be installed in a non-compatible meter base or used improperly. GenerLink must be installed and operated in accordance with the following installation instructions and the GenerLink Operating Manual. WARNING GenerLink allows for the interconnection of a 120/240 volt generator with a continuous output of 30 Amperes or less. Any source connected to GenerLink that does not meet this criteria or exceeds this rating could cause serious operator injury or damage GenerLink. Figure 1 DANGER Installation of GenerLink must only be performed by properly trained technicians. Do not proceed with this installation unless you have been authorized by your local electric utility to do so. Remove the meter can cover. DANGER 240-Volt potential exists across the top jaws when GenerLink is installed in a meter can.

Section 1 - Installation in Ring-less Style Meter Cans Installation of GenerLink is fast and easy. For installations in ring-less style cans, the procedure (shown in Figure 1) is as follows: NOTE: GenerLink has been designed for installation with a wide variety of meter cans. In some cases, the cover will fit tightly to GenerLink as it rotates. Do not attempt to cut, file or otherwise modify GenerLink in order to facilitate this step. Modifications will jeopardize the security of the installation and will void the warranty. Step 5 Install and secure the meter with a locking ring. Remove the meter can cover. Step 5

Step 2 Install the Neutral/Ground lead connection from GenerLink. Depending on the type of meter can, either a #6/#8 Hi-lug or a split-nut ground connection should be used. The grounding method selected should be consistent with local codes and standards for your area. Step 3 Step 2a Hi-Lug Ground Installation Step 2b Split-nut Ground Installation Step 3 Connect the neutral/ground leads together. Insert GenerLink by carefully aligning with the jaws of the meter can and pushing the blades firmly into the jaws. Check for normal utility presence with the indicator lights on GenerLink. For normal utility presence, the green light is illuminated with or without the yellow light. Position the Meter Can Cover over GenerLink as shown in the diagram Step below. 4 Rotate the cover over GenerLink and position into place for closure. DANGER 240-Volt potential exists across the top jaws when GenerLink is installed in a meter can.