Rhino SD/XD Pump Overlap Time-Delay Module Description See Figure. The Rhino SD/XD Pump Overlap Time-Delay module consists of a pneumatic time-delay valve () that is installed into the drum empty circuit. When a drum empty condition occurs, both pumps must be operating to perform a standard changeover from the active to the standby pump. The time-delay valve delays the shutdown of the air motor on the active pump to prevent loss of output pressure. Pump overlap is necessary if a drop in supply pressure to the dispense system is seen during the pump changeover sequence. This typically occurs in systems that use short hoses or header system circuits. Installation Adjustment See Figure. The time-delay valve is adjustable from 0 30 seconds. NOTE: The overlap time is the amount of time that both pumps are active. Turn the adjustment screw () clockwise (in) to increase the overlap time. Turn the adjustment screw () counterclockwise (out) to decrease the overlap time. NOTE: Turning the adjustment screw fully counterclockwise (out) disables the overlap time and may produce a momentary drop in output pressure when the standby pump comes up to speed. WARNG: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. See Figures and to install the time-delay valve into the drum empty circuit. DECREASE CREASE Figure Pump Overlap Time-Delay Module 006 Nordson Corporation
Rhino SD/XD Pump Overlap Time-Delay Module Parts See Figure and the following parts list. To order parts, call the Nordson Customer Service Center or your local Nordson representative. 3, 6, 7, 8, 9, 3 (6. in.) 3 (8 in.) REMOVE THIS MALE RUN TEE AND STALL ITEM 0. 3 (3. in.) 0, Figure Pump Overlap Time-Delay Module Parts 006 Nordson Corporation
Rhino SD/XD Pump Overlap Time-Delay Module 3 Item Part Description Quantity Note 006 Module, pump overlap, time delay 9830 Nut, hex, heavy, / -0, steel, zinc 3977 Washer, lock, e, split, /, zinc, GA 3 006 Elbow, male, / T x / 8 R (PT) 0067 Valve, time-delay, 3-way, -pos, G / ISO thds 9898 Screw, socket, / -0 x.00, BL 6 33 Adapter, G / ISO x / NPT 7 0067 Connector, male, / T x / R (PT) 8 0066 Muffler, male, / BSPT 9 0063 Elbow, male, / T x / NPT, triple universal 0 979 Elbow, male, / tube x / 8 NPT 9008 Adhesive, pipe/thread/hydraulic sealant (paste) AR A 9006 Adhesive, Loctite, blue, removable, 0ml AR B 3 0080 Tubing, / OD polyethylene, flame resist. ft NOTE A: Apply to NPT threads. B: Apply to male threads only on adapter. AR: As Required 006 Nordson Corporation
Rhino SD/XD Pump Overlap Time-Delay Module Time-Delay Valve Pneumatic Schematic System Pneumatic Schematics See Figure 3. P R Figure illustrates a system with a time-delay module. See Figure if it is necessary to reconfigure the system without a time-delay module. Z A Figure 3 Time-Delay Valve Pneumatic Schematic Original copyright date 006. Nordson, the Nordson logo, and Rhino are registered trademarks of Nordson Corporation. All other trademarks are the property of their respective owners. 006 Nordson Corporation
Rhino SD/XD Pump Overlap Time-Delay Module A UNIT AUTO CHANGEOVER WITH OVERLAP TIME-DELAY B UNIT / HOSE / HOSE 3/ HOSE 3/ HOSE DP DP L DP BALL DP DP L DP S7 S6 BALL PS PS BULK UNLOADER FRAME EMPTY DRUM LOGIG 3 BULK UNLOADER FRAME EMPTY DRUM LOGIG 3 OPTIONAL PUMP OVERLAP TIME-DELAY MODULE Z M0TOR 3 P MA S MA MICRON MASTER BALL MA OPTIONAL PUMP OVERLAP TIME-DELAY MODULE Z M0TOR 3 P MA S MA MICRON MASTER BALL MA T A P R T T P T A P R T T P /. TUBG FROM PORT ON THE TIME DELAY MODULE TO THE LOGIG PORT / OF THE OTHER UNIT /. TUBG FROM PORT ON THE TIME DELAY MODULE TO THE LOGIG PORT / OF THE OTHER UNIT Figure Auto Changeover with Overlap Time-Delay Pneumatic Schematic 006 Nordson Corporation
Rhino SD/XD Pump Overlap Time-Delay Module 6 A UNIT AUTO CHANGEOVER WITH OVERLAP TIME-DELAY B UNIT / HOSE / HOSE 3/ HOSE 3/ HOSE DP S7 S6 DP DP L DP BALL DP L DP BALL PS PS BULK UNLOADER FRAME EMPTY DRUM LOGIG BULK UNLOADER FRAME EMPTY DRUM 3 3 LOGIG M0TOR 3 P MA S MA MICRON MASTER BALL MA M0TOR 3 P MA S MA MICRON MASTER BALL MA P P /. TUBG PILOT PORT / TO THE LOGIG PORT / OF THE OTHER UNIT /. TUBG PILOT PORT / TO THE LOGIG PORT / OF THE OTHER UNIT Figure Auto Changeover without Overlap Time-Delay Pneumatic Schematic 006 Nordson Corporation