Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

Similar documents
Worcester 519 / 529 Series

Installation, Operating & Maintenance Instructions. Worcester 18 / 19 Series Multiway Valves

Stem Assembly Supplement

Anodised aluminium construction for anti-corrosion and superior wear performance on internal surfaces

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Magnetic Level Gauges

Limit Switch Type 4747

II 2GD. xxxx. Westlock 2200 Series Quantum - ATEX certified Installation & Operating Instructions

BS EN ISO 9001 FM Worcester Controls E51/52 Enviro-Safe High Integrity Flanged Ball Valves

1000 Series Piston Type Differential Pressure Gauges

Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Worcester 18/19 Series. Modular Multi-Way Ball Valves

1100 Series Piston Type Differential Pressure Gauges

Worcester 18/19 Series. Modular Multi-Way Ball Valves

Easytork Solenoid Valve IOM

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

Worcester 53/54 Series. Reduced Bore Flanged Ball Valves to DIN 3202

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement Point level measurement - RF Capacitance switches

10 Load and Motor Switchgear

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control

Magnetic Level Gauges

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Operating Instructions

Solenoid Valves Type 3963

SP2 Options Installation and Maintenance Instructions

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Automax SuperNova Series. Pneumatic Rack & Pinion Actuators

Operation Manual Cobra 1 Automatic Spray Gun

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

Type 2000 Transducer Product Instructions

Integrated Valve Assemblies FORAC

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

Installation Operation Maintenance

OPERATING INSTRUCTIONS

Pressure Switch SOR. Sifter ready to run: Adequate pressure to switch. Sifter not ready to run: Either loss of air pressure, or open guard.

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

With regards to safety it is not necessary to check for correct operation.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

102 Differential Pressure Switch

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

switchcontrol The robust opto-electric position indicator

General purpose / hazardous area

Installation Operation Maintenance

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

103 Differential Pressure Switch

Operating Instructions

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Operating Instructions

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

Level Measurement based on Archimedes Principle. Device Description

Valve Position Monitors

Flameproof Level Sensor (Flameproof F/S FP)

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

ACCUTRAK ROTARY MODELS 1040/9358/2004/9044/9468/5004/5044/2007/9479/5050 INSTALLATION AND OPERATIONS MANUAL

SB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun

PMV WS/WM Series UltraSwitch

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

1. General warnings Applicable regulation. EN ISO : 2005: Safety of machinery

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

SATRON VDt Differential Pressure Transmitter

OPERATION MANUAL FLG-G5-14 Transtech Gravity Spraygun

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

Q u a r t e r T u r n E l e c t r i c A c t u a t o r s

Electrical position indicators and combi switchboxes for linear and quarter turn valves

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

CCAI, CCAIF, CCAIF..H

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

Material pressure (bar) (Cv (US) kv x 1,2 Seat

flowserve.com Limitorque LRP Limitorque Rack & Pinion Pneumatic Actuator

Electrical position feedback for actuator sizes Ø mm

Valve Positioners Series 760P/E Valve Positioners

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

10 S e r i e s PRESSURE SWITCH. features

Installation Operation Maintenance

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Guidance to Installers of Viridian EV Charging Stations

Compact System NRGS 11-2 NRGS Original Installation Instructions English

LIMIT SWITCH BOX MODEL - APL

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

SB-E ISS.05. Operation Manual AA4400A Automatic Air Assisted Airless Spray Gun

BR 31a Rack-and-pinion Actuator,

Zone 1 Linear Range - Installation Guide

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Accord DS/DM Series UltraSwitch Switch box

SITRANS P measuring instruments for pressure

Series 3730 Type Electropneumatic Positioner. Fig. 1 Type Mounting and Operating Instructions EB EN ( )

A Type Double Acting Actuator Type: PA2911

Operating Instructions

Transcription:

Installation, Operating & Maintenance Instructions Norbro J-Switch as FM 00707

INTRODUCTION The J-Switch is a control package incorporating switches, sensors or pneumatic valves for actuator end of travel indication. It is retrofitable to all sizes and revisions of Norbro 40R series actuators from size 10 to 42 and 40 series from size 10 to 50 by simply specifying the product with the relevant operating pin lengths, removing the actuator blanking plugs and attaching to the actuator endcap. It may also be supplied factory fitted to the actuator. Example X29 Option B R B R B R B R B R R B B R R B Pistons Together Pistons Apart 1 STORAGE AND PRESERVATION When dispatched, all J-Switches are prepared for storage. All protective packaging, end cap port plugs, pinion covers etc. should remain in position until the J-Switch is due to be installed. J-Switches should be stored in a clean, dry environment.

2 J-SWITCH MARKINGS Each J-Switch has the following identification information on the product label attached to the side of the body: Non-ATEX J-Switch Label FLOWSERVE FLOW CONTROL (UK) Ltd PRODUCT CODE CE MARK NORBRO J-SWITCH IP66 250VAC 15A/4A **- RK0ES- 1SJ*-X29 S*****/*- * 06 03 Flowserve (UK), Burrell Rd. Haywards Heath, RH16 1TL SWITCH SPECIFICATION PRODUCT VARIATION EAR OF MANUFACTURE ATEX J-Switch Label FLOWSERVE FLOW CONTROL (UK) Ltd PRODUCT CODE CE MARK NORBRO J-SWITCH IP66 15.5VDC 52mA CERT PTB 00 ATEX 2032 X **- RK0ES- 1SJ*-P&F S*****/*- * 06 03 Flowserve (UK), Burrell Rd. Haywards Heath, RH16 1TL SWITCH SPECIFICATION PRODUCT VARIATION EAR OF MANUFACTURE EXPLOSION PROTECTION SMBOL, EQUIPMENT GROUP & CATEGOR, ZONE SUITABILIT AND PROTECTION TPE ATEX Directive: If the product label carries the ATEX Directive number '94/9/EC' followed by the Explosion Protection Symbol and codes identifying the equipment group and category, the zone suitability and protection type beside the CE mark, the product complies with the ATEX Directive and The Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 1996. Definition of product label marking above: 'II' = Equipment Group; '2' = Equipment Category; 'G' = Gas Zone suitability (Zones 1 & 2); 'D' = Dust Zone suitability (Zones 21 & 22); 'c' = type of protection i.e. constructional safety (pren 13463-5); 'X' = Refer to IOM for special safety instructions. EEx = Explosion protection to: 'd' = Flameproof enclosure. 'ia' = Intrinsic safety. 'n' = Non-incendiary. Surface Temperature: As per EN 13463-1:2001(E) paragraph 14.2.g, the temperature class or maximum surface temperature cannot be marked on the product as it is dependant on the operating conditions.

3 HEALTH AND SAFET When installing or maintaining J-Switch: a) Conduct a risk assessment and eliminate or reduce hazards to an acceptable level. b) Work in accordance with Safe Systems of Work. c) Observe all site Health and Safety Rules in particular Permit to Work and Hot Work procedures. d) Wear all necessary Personal Protective Equipment. e) Never remove or maintain a J-Switch or joint unless the actuator supply has been fully de-pressurised, drained and where necessary, purged of toxic / explosive / flammable media. Always operate the actuator to ensure that no trapped pressure exists. f) Never use a J-Switch on a duty, which exceeds its prescribed operating parameters. Refer to Flowserve Flow Control (UK) Ltd. Technical Sales for further information. g) Never modify or alter J-Switches unless the manufacturer has been consulted and/or recommends such changes. h) Due to the large physical size and weight of some sizes of this product, always use correct lifting methods and equipment when installing, removing and maintaining the product, and that it is correctly supported in its final operating location. i) Due to the variety of duties on which this product can be employed, it is the end users responsibility to ensure the compatibility of the product with the specific application (i.e. signal voltage, corrosion, which may effect it's suitability). j) Before equipment is installed in areas which may be subject to seismic activity or extreme climatic conditions consult Flowserve Flow Control (UK) Ltd. Technical Sales. k) If the processes or environments that the products are used in are likely to cause temperatures (high or low) that may cause injury to personnel if touched, then adequate insulation/protection must be fitted. l) If the equipment is to be used on unstable gas duty, ensure that the operational parameters as indicated on the product label cannot be exceeded. m) Do not rub J Switch with a dry cloth as this can cause a build up of static charge. Only clean with a damp cloth.

4 SPECIFICATION 4.1 ENVIRONMENTAL CONSIDERATIONS It should be noted that the successful use of this device in wet, or other detrimental environments (e.g. the intrinsically safe version for hazardous areas) depends on proper conduit installation techniques. Electrical conduit options are M20 x 1.5p, Pg 13.5, Pg 16, ½ NPT and Plug / Socket. To uphold the IP66 rating obtained on the J-Switch product, a conduit gland of equal or better IP rating should be fitted. The operating temperature of the J-Switch is restricted to the temperature range of the switch option chosen. This information is detailed in the switch operating specifications. Standard J-Switch enclosure temperature range (excluding switch, sensor, valve and terminal temperature limits) is -20 C to +100 C. 4.2 SWITCH & SENSOR OPTIONS / ELECTRICAL SPECIFICATIONS Detailed below are the switch, sensor and valve options available and their specific characteristics, operating voltages, current ratings, the working temperature range and the type of wire termination. ATEX marked variants are suitable for II2GDC. X23 Ex N/d II Single Pole Double Throw (SPDT) ATEX 5A resistive 3A inductive up to 30VDC 5A resistive 5A inductive up to 250VAC Switch temperature range -62 C to +150 C SWITCH RATED LIFE: 25 000 cycles NOTE: The J-Switch enclosure temperature range (excluding switch temperature limits) is - 20 C to +100 C. Working temperature range for this option is -20 C to +100 C. The flying leads which are 900mm in length are an integral part of the switch. Ensure that the wires are terminated by a qualified electrician to a suitable customer supplied device. X26 Gold contacts Ex N/d II Single Pole Double Throw (SPDT) ATEX 5A resistive 3A inductive up to 30VDC 5A resistive 5A inductive up to 250VAC Switch temperature range -62 C to +150 C. SWITCH RATED LIFE: 25 000 cycles NOTE: The J-Switch enclosure temperature range (excluding switch temperature limits) is - 20 C to +100 C. Working temperature range for this option is -20 C to +100 C. The flying leads which are 900mm in length are an integral part of the switch. Ensure that the wires are terminated by a qualified electrician to a suitable customer supplied device.

4 SPECIFICATION (cont.) X29 X56 X66 Gold contacts Single Pole Double Throw (SPDT) 10A resistive 4A inductive up to 12 VDC 10A resistive 1.5A inductive up to 24 VDC 15A resistive 4A inductive up to 250 VAC Switch temperature range -40 C to +85 C SWITCH RATED LIFE: 10 000 000 cycles NOTE: The J-Switch enclosure temperature range (excluding switch temperature limits) is - 20 C to +100 C. Working temperature range for this option is -20 C to +85 C. The switches are terminated in a 2 x 3 way terminal strip mounted on the bracket. There is also a plug/socket version available. All wiring must be carried out by a qualified electrician. Pneumatic Normally Non Passing 2/2 Telemecanique Electrique valve Push In connectors for 4 mm diameter plastic tubing. 0 to 6 bar. SWITCH RATED LIFE: 10 000 000 cycles NOTE: The J-Switch enclosure temperature range (excluding valve temperature limits) is - 20 C to +100 C. EEx d IIc Single Pole Double Throw (SPDT) ATEX 5A resistive 3A inductive up to 30VDC 5A resistive 5A inductive up to 250VAC Switch temperature range -20 C to +55 C SWITCH RATED LIFE: 1 000 000 cycles NOTE: The J-Switch enclosure temperature range (excluding switch temperature limits) is - 20 C to +100 C. Working temperature range for this option is -20 C to +55 C. The flying leads which are 0.5 metres in length are an integral part of the switch. Ensure that the wires are terminated by a qualified electrician to a suitable customer supplied device. INTRINSICALL SAFE VARIATIONS NOTE: Switches / sensors are simple apparatus and therefore can be used for I.S. circuits with an appropriate barrier. X65 As X29, but labelled INTRINSICALL SAFE. ATEX P&F EEx ia IIC T6 inductive proximity sensor ATEX 2 wire 8 VDC, <1 ma actuated, >3 ma unactuated Sensor temperature range -25 C to +100 C. SWITCH RATED LIFE: 165 years at 30 C NOTE: The J-Switch enclosure temperature range (excluding sensor temperature limits) is - 20 C to +100 C. The working temperature range for this option is -20 C to +100 C. The sensors are terminated in a 2 x 2 way terminal strip mounted on the bracket. All wiring must be carried out by a qualified electrician.

5 INSTALLATION The J-Switch can be supplied either as a retrofitable product to a Norbro actuator or preassembled by the factory to a Norbro actuator. WARNING: Prior to fitting the J-Switch to a Norbro actuator, it is necessary to fully vent all actuator chambers of pressure. This can be done by isolating the feed air supply, then venting both the air chambers within the actuator. To achieve this, operate the solenoid/control valve to both positions with no supply pressure which will allow both chambers to vent. 5.1 FITTING A J-SWITCH TO A NORBRO ACTUATOR a) Remove the two end cap plugs from the switch end cap. b) Remove the J-Switch cover and the plastic bag containing O rings, screws and bonded seals. c) Remove bracket screws in base of enclosure. d) Remove bracket assembly from housing, noting the orientation of the bracket assembly with the housing conduit entry. e) Fit greased O rings (two large, two small) to external recesses of housing. f) Align the housing (standard build conduit entry facing down) with the actuator end cap fixing pattern. g) Place bonded seals over appropriate screws and secure housing to actuator end cap. IMPORTANT: Ensure that the operating pins on the bracket assembly are adjusted so that the slotted end of the pins have approximately 9mm protruding above the top lug. h) Insert bracket assembly into housing in the same orientation as when it was removed, through into actuator (long operating pin into left hole). j) Secure with the two mounting screws. k) Temporarily fit the cover and pressurise the left inlet end cap port of the actuator. Check the end cap / housing interface integrity with leak detection fluid. Remove all excess fluid after the check has been completed.

5 INSTALLATION (cont.) 5.2 ADJUSTING THE SWITCH AND SENSING POSITIONS Actuators factory fitted with a J-Switch are dispatched from Flowserve Flow Control (UK) Ltd. with the switch / sensor switching point already set at the stroke end positions. However, minor adjustments may be required once the product has been installed (e.g. fitted to a valve with restricted rotation). If adjustment is required, follow the instructions below:- a) Remove the J-Switch cover, pressurise the right inlet endcap port. The actuator will rotate anti-clockwise (pistons apart - open). b) Viewed from the J-Switch, rotate the left operating pin anti-clockwise (retracting the operating pin) by approximately three rotations. c) Rotate the operating pin clockwise until the microswitch clicks or the sensor operates. Release the pressure from right inlet end cap port. d) Pressurise the left inlet endcap port. The actuator will rotate clockwise (pistons together - closed). e) Viewed from the J-Switch, rotate the right operating pin anti-clockwise (retracting the operating pin) by approximately three rotations. f) Rotate the operating pin clockwise until the microswitch clicks or the sensor operates. Release the pressure from left inlet end cap port. g) Check switch function by cycling the actuator with an Ohmmeter across the appropriate terminals of one switch. h) Repeat (g) for the other switch. NOTE: Sensor function can be checked in a similar way with an appropriate checking device. The J-Switch has now been correctly adjusted and can be wired to another device by a qualified electrician. The cover must now be replaced.

6 OPERATION The cover of the J-Switch must be fitted and the enclosure fully sealed before the actuator can be operated. This should only be done in accordance with site procedures by authorised personnel. The J-Switches switch / sensor only operates when the actuator has been pressurised and has travelled to the extreme of its travel or is in its end of travel position while unpressurised.

7 MAINTENANCE WARNING: Maintenance must be carried out by qualified personnel. Prior to any maintenance being carried out on the J-Switch it is necessary to fully vent all actuator chambers of pressure. This can be done by isolating the feed air supply then venting both the air chambers within the actuator. To achieve this, operate the solenoid / control valve to both positions with no air supply pressure, which will allow both chambers to vent. The device may have live AC / DC connection therefore all electrical supplies to the J-Switch must be disconnected. All local wiring regulations must be followed. 7.1 REPAIR KIT ACTUATOR SHOWN PISTONS TOGETHER (CLOSED POSITION) ACTUATOR END CAP J-SWITCH TERMINAL BLOCK (non flying lead versions) A A PINION POSITION 4 7 5 2 3 1 6 ACTUATOR END CAP 3 Repair kit code 00-ARKES-### repairs all sizes of J-Switch attached 40R & 40 Series of designated switch option. Grease: Rocol Sapphire Lo-Temp 2 PART SECTION A-A J-SWITCH HOUSING J-SWITCH BRACKET Item No. Description Qty. Part No. 1* Switch / roller lever assembly / insulator sheet 2 ### in repair kit code 2 Cam 2 ES-10-208 3 O Ring - housing screw recess and cam 4 R008 4 O Ring - housing pin recess 2 R014 5 O Ring - pin 2 R802 6 Cover gasket 1 ES-10-230 7 Bonded seal 4 PP45-3 * All switches and sensors are supplied with leads attached. Certain switch options are provided with soldered leads for termination to the terminal strip, others have a separate switch roller lever if applicable. ### Denotes switch type e.g. X29.

7 MAINTENANCE (cont.) 7.2 MAINTENANCE INSTRUCTIONS Only components approved by the manufacturer should be used for the repair and maintenance of the J-Switch. Flowserve Flow Control (UK) Ltd. will not accept any responsibility for problems arising from the use of non-authorised components. For each of the J-Switch repair kit switch / sensor / valve options, the contents can be used to repair all sizes of J-Switch attached to both the 40R / 40 series of actuator. To order the correct repair kit for the J-Switch product, clearly state the switch, sensor or valve type or the complete J-Switch product coding from the label. 7.3 DISMANTLING INSTRUCTIONS WARNING: Maintenance must be carried out by qualified personnel. All local wiring regulations must be followed. Before removing the J-Switch cover, ensure that electrical supply has been isolated. It is also necessary to fully vent all actuator chambers of pressure. This can be done by isolating the feed air supply, then venting both the air chambers within the actuator. To achieve this, operate the solenoid / control valve to both positions with no supply pressure which will allow both chambers to vent. 7.3.1 DISMANTLING a) Remove cover screws and cover. b) Disconnect customer wires from terminal strips, noting the colours for each termination. c) Remove bracket screws in base of enclosure. d) Remove bracket assembly from housing. e) Remove housing to actuator screws. f) Remove housing from actuator end cap. g) Loosen switch wires from terminal strips (if present). h) Remove switch securing screws. j) Remove switches (insulation sheet and lever operators if present). k) Rotate an operating pin clockwise, viewed from the slotted end. The operating pin will become disengaged from the cam. Withdraw from bracket assembly whilst constraining the spring and the cam. l) Compress cam spring enough to withdraw cam and spring from bracket. m) Repeat for remaining operating pin / spring / cam. Remove all O rings taking care not to damage grooves or sealing surfaces. Carefully clean components and check for damage.

7 MAINTENANCE (cont.) 7.4 RE-ASSEMBL NOTE: Where greasing is specified, use Rocol Sapphire Lo-Temp 2 Grease. 7.4.1 HOUSING / END CAP a) Ensure that the sealed recesses are clear and undamaged. b) Fit greased O rings (two large, two small) to external recesses of housing. c) Align the housing (standard build conduit entry facing down) with the actuator end cap fixing pattern. d) Place bonded seals over appropriate screws and secure housing to actuator end cap. 7.4.2 BRACKET ASSEMBL a) Fit greased O ring to cam recess. b) Place spring on cam O ring. c) Compress cam spring enough to insert cam and spring between bracket lugs (cam ramp must be positioned at the base and towards centre of bracket). d) Insert slotted end of long operating pin through base of bracket on earth point E side of bracket (size 10 has operating pins of equal length). Rotate slotted end anti-clockwise until approximately 9mm is protruding above the top lug. e) Repeat for other operating pin / spring / cam f) X29 AND P&F ONL: Secure the switch wires to the terminal strips, referring to the wiring diagram on the inside of the lid. g) Place switch and lever operator onto bracket (for the X29 place the insulating sheet between the switch and the bracket). h) Secure switch to bracket. j) Repeat for other switch. k) Fit greased O rings over operating pins.

7 MAINTENANCE (cont.) 7.4.3 BRACKET / HOUSING ASSEMBL a) With the earth point E facing the conduit entry (standard build conduit entry facing down), insert bracket assembly into housing and through into actuator (long operating pin into left hole). If the switch has flying leads, pull these through the conduit entry. b) Secure bracket to housing. 7.4.4 ADJUSTMENT AND TESTING a) Temporarily fit the cover and pressurise the left inlet end cap port of the actuator. Check the end cap / housing interface integrity with leak detection fluid. Remove all excess fluid after the check has been completed and remove cover. b) With the right inlet end cap port of the actuator pressurised, rotate the left operating pin clockwise until the switch activates. Repeat for the left port and right operating pin. c) With no electrical supply connected, cycle the actuator checking that the switches are activated. WARNING: The cover of the J-Switch must be fitted and the enclosure fully sealed before the electrical supply is connected and the actuator operated. This should only be carried out in accordance with site procedures by authorised personnel. d) Re-connect customer wires to terminal strips, colour / termination as noted on removal and check that the switches function appropriately. e) Replace cover.

The J-Switch complies with the following European directives: 89/36/EEC 73/23/EEC 92/59/EEC 94/9/EC Electromagnetic Compatibility Low Voltage Directive General Product Safety ATEX Directive Flowserve Flow Control (UK) Ltd. Burrell Road, Haywards Heath, West Sussex RH16 1TL, England. Telephone: +44 (0)1444 314400 Telefax: +44(0)1444 314401 Website: www.flowserve.com Published and Printed by Flowserve Flow Control (UK) Ltd. Information given in this leaflet is made in good faith and based upon specific testing but does not, however constitute a guarantee. Copyright Flowserve Flow Control (UK) Ltd. PB J SWITCH IOM Iss. 11/03