PHONE: (303) FAX: (970) WEBSITE:

Similar documents
PHONE: (303) FAX: (303) WEBSITE:

S BERGIN R BEATTIE Lighting Engineer. Checked Approved

PHONE: (303) FAX: (970) WEBSITE:

LEN Series 2x2 / 2x4 LED

LED Black Housing High Output Remote Capable

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE:

Test Sample Description Catalog Number: Description:

2 LED Designer Series

Test Sample Description Catalog Number: Description:

IES INDOOR REPORT PHOTOMETRIC FILENAME : 4A_ASD-LVP10M-4N3135-PRM_IES.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : LHB K-U80-UNI.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : VW4-LED48DMVSSF50.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : C6R UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File)

LED E-Series. we know light. LED Cents LED E-Series troffers gives you the appearance of fluorescent technology with a tube-like glow.

LIGHT LABORATORY, INC E Kaiser Blvd. Anaheim, CA 92808

NVLAP LAB CODE:

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description:

LED Flat Panel Luminaires

LED Flat Panel Luminaires

NVLAP LAB CODE:

Lisun Electronics Inc. Tel:+86(21)

Report of Test LLIA

Lisun Electronics Inc. Tel:+86(21)

Report of Test LLIA

Report of Test LLIA

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MaxLite 12 York Ave. West Caldwell, NJ.

Calibration Due Date Chroma Programmable AC Source 61604

Report of Test LLIA

Report of Test LLIA

Report of Test LLIA

Highbay Fluorescent - Six Lamp Low Profile Design

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Lighting Sciences

Report of Test LLIA

LED Flat Panel Luminaires

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Fixture Spec Sheet HFA2 Series 4/15/2011

Luminaire Property. Photometric Results. Lightel Pty Ltd. Tel: Page 1 of 16 Pages. Report No.: Test Time: 2014/4/4 10:28

Applications. Illustrated Features

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Maxlite Jersey Blvd Rancho Cucamonga, CA 91730

Fixture Spec Sheet HFB3 Series 4/15/2011

INDEPENDENT TEST LABORATORY REPORT No

Highbay Fluorescent - 3 or 4 Lamp Curved Profile Design

Report of Test LLIA


Cat# 71712A LED Linear High Bay 120W

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No A

Highbay Fluorescent - Six Lamp Flat Profile Design

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Report of Test LLIA

Integrating Sphere Test Report

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH

LED Stairwell Fixture

LED Warehouse Industrial Lighting - 2 Ft Compact High Bay SPEC SHEET

Photometric Indoor Test Report

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260

Integrating Sphere Test Report

Integrating Sphere Test Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

PART #: PROJECT: NOTES: APPROVAL SIGNATURE: Color Rendering (CRI) QTY Series

Calibration Due Date Chroma Programmable AC Source 61604

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

T8 4ft 5000K EazyLux EZ8450D7R07

Linear. FloatPlane Suspended LED

Plaster Flange Flangeless. Flange (All Ceilings) Donn Fineline Armstrong Bolt

apollo 8 patient bed light with LED options features dimensional data performance

Plaster Flange Flangeless. Donn Fineline Armstrong Bolt. Flange (All Ceilings)

Rail 4 RM4DI (Formerly Grande) LED. Pendant. Direct/Indirect

HP90 Recessed 2'X2' Fluorescent; T8, T5, T5HO or TT5

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Plaster Trim Flange Trim Trimless. for ceilings requiring a flange. Donn Fineline Armstrong Bolt

Report of Test LLIA

Report of Test LLIA A

LUCEN 2x2 ARCHITECTURAL RECESSED LUMINAIRE

OPTIONS OPERA SPI. Indirect lighting that rises above low-ceiling limitations.

Report of Test LLIA A-R01*

IES INDOOR REPORT PHOTOMETRIC FILENAME : ETLB7-2FT 4L 110 DM FL 5700K.IES. DESCRIPTION INFORMATION (From Photometric File)

Apollo 8. lamping. patient bed pair example. 8" wide recessed patient bed light with exam function available in 2', 3' & 4' lengths.

Report of Test LLIA A

Report of Test LLIA A

DL2000. High Brightness 6 LED Downlight Module. Transforming Your Vision into Higher Performance Solutions. Overview

Report of Test LLIA A

DRIVER OUTPUT F Fixed DM 0-10v Dimming 1 COLOR TEMP 51K 5100

Report of Test LLIA A-R02*

QCF IP65. LED Gas Canopy Fixture SPECIFICATIONS CERTIFICATION ORDERING INFORMATION EXAMPLE QCF-UL-60C-F-51K-GCO CERTIFIED

Report of Test LLIA A

VSL4 Series. Description. Specifications. 2.13in. 2.03in. 3.50in

RLP Edge-Lit 2X2, 2X4, 1X4

Report of Test LLIA

Photometric Outdoor Test Report

LLIA A-R02*

Photometric Outdoor Test Report

Report of Test LLIA A

003 3 foot foot RUN Nominal Length* * For actual lengths see

Report of Test LLIA A

Transcription:

REPORT NUMBER: ITL77175 PAGE: 1 OF 5 CATALOG NUMBER: 2-5105-24 LUMINAIRE: FABRICATED SPECULAR METAL HOUSING, FORMED WHITE PAINTED METAL REFLECTOR, TRANSLUCENT WHITE ACRYLIC DIFFUSER. BALLAST IS EXPOSED AND CENTERED IN THE OPTICAL COMPARTMENT. LAMPS: TWO 21-WATT T-5 SYLVANIA FP21/841/ECO LINEAR FLUORESCENTS. BALLAST: ANTRON ELECTRONICS ESD-A21T5S THE 0 DEGREE PLANE IS PERPENDICULAR TO THE LAMPS. TOTAL REFLECTANCE OF PAINT = 76.2 % MOUNTING: WALL 37 33 TOTAL INPUT WATTS = 44.4 AT 120.0 VOLTS NOTE: ACRYLIC MATERIAL INFORMATION PROVIDED BY CLIENT. REPORT IS BASED ON 1900 LUMENS PER LAMP. * CANDELA DISTRIBUTION FLUX 0.0 45.0 90.0 135.0 180.0 0 125 125 125 125 125 5 137 133 125 123 123 12 15 172 154 122 116 115 38 25 204 173 115 106 104 64 35 232 188 104 92 90 86 45 254 198 90 76 73 103 55 270 203 74 58 55 112 65 277 201 56 39 36 113 75 277 195 37 20 17 107 85 270 184 18 3 2 95 90 263 179 11 0 0 95 266 182 17 3 2 93 105 275 194 35 19 17 105 115 277 202 54 38 36 113 125 270 203 73 57 55 112 135 255 199 89 76 73 103 145 233 190 104 92 89 86 155 205 175 115 106 104 64 165 173 156 122 117 115 38 175 139 134 126 123 122 12 180 126 126 126 126 126 ZONE LUMENS %LAMP %FIXT 0-30 114 3.0 7.8 0-40 200 5.3 13.7 0-60 414 10.9 28.5 0-90 729 19.2 50.1 90-120 311 8.2 21.4 90-130 423 11.1 29.1 90-150 612 16.1 42.1 90-180 726 19.1 49.9 0-180 1455 38.3 100.0 TOTAL LUMINAIRE EFFICIENCY = 38.3 % * CIE TYPE - GENERAL DIFFUSE PLANE : 0-DEG 90-DEG 180-DEG SPACING CRITERIA : 2.55 1.30 1.16 SHIELDING ANGLES : 90 90 * SEE ADDENDUM FOR FURTHER INFORMATION 260 130 130 260 180 165 0 15 30 45 LEGEND: 0-deg 90-deg 180-deg Checked Approved 2 1/2 0 150 B HYRE R BEATTIE Lighting Engineer 135 120 105 90 75 60

REPORT NUMBER: ITL77175 PAGE: 2 OF 5 CANDELA DISTRIBUTION LATERAL ANGLE 0.0 22.5 45.0 67.5 90.0 112.5 135.0 157.5 180.0 0.0 125 125 125 125 125 125 125 125 125 5.0 137 136 133 128 125 124 123 123 123 10.0 155 152 144 133 124 121 120 120 119 15.0 172 168 154 137 122 118 116 116 115 20.0 188 182 164 140 119 114 112 111 110 25.0 204 196 173 142 115 108 106 105 104 30.0 219 209 182 144 110 102 99 98 97 35.0 232 221 188 144 104 95 92 91 90 40.0 244 231 194 143 98 88 84 83 82 45.0 254 239 198 141 90 79 76 74 73 50.0 263 247 201 138 83 71 67 65 64 55.0 270 252 203 135 74 61 58 56 55 60.0 274 255 203 130 65 52 48 46 45 65.0 277 257 201 124 56 42 39 37 36 70.0 278 257 199 118 46 32 29 27 26 75.0 277 255 195 111 37 23 20 18 17 80.0 274 252 190 104 27 14 11 9 9 85.0 270 247 184 97 18 5 3 2 2 90.0 263 241 179 90 11 0 0 0 0 95.0 266 244 182 95 17 4 3 2 2 100.0 272 250 188 103 26 12 10 9 8 105.0 275 254 194 110 35 22 19 18 17 110.0 277 256 198 117 45 31 28 27 26 115.0 277 257 202 124 54 41 38 36 36 120.0 275 256 204 130 64 51 48 46 45 125.0 270 253 203 134 73 60 57 55 55 130.0 264 248 202 138 81 70 67 65 64 135.0 255 241 199 141 89 79 76 74 73 140.0 245 232 195 143 97 87 84 82 82 145.0 233 222 190 144 104 95 92 90 89 150.0 220 211 183 144 110 103 99 98 97 155.0 205 198 175 143 115 109 106 105 104 160.0 190 184 166 140 119 114 112 111 110 165.0 173 169 156 137 122 118 117 116 115 170.0 156 154 145 133 124 122 120 120 119 175.0 139 138 134 129 126 124 123 123 122 180.0 126 126 126 126 126 126 126 126 126

REPORT NUMBER: ITL77175 PAGE: 3 OF 5 5-DEGREE 10-DEGREE 0-5 3 0-10 12 5-10 9 0-20 50 10-15 16 0-30 114 15-20 22 0-40 200 20-25 29 0-50 303 25-30 35 0-60 414 30-35 40 0-70 527 35-40 45 0-80 634 40-45 50 0-90 729 45-50 53 0-100 822 50-55 55 0-110 927 55-60 57 0-120 1040 60-65 57 0-130 1152 65-70 56 0-140 1254 70-75 54 0-150 1341 75-80 52 0-160 1404 80-85 49 0-170 1443 85-90 46 0-180 1455 90-95 45 95-100 48 100-105 51 105-110 54 110-115 56 115-120 57 120-125 57 125-130 55 130-135 53 135-140 50 140-145 46 145-150 41 150-155 35 155-160 29 160-165 22 165-170 16 170-175 9 175-180 3

REPORT NUMBER: ITL77175 PAGE: 4 OF 5 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 41 41 41 41 38 38 38 38 32 32 32 26 26 26 22 22 22 19 1 36 34 32 30 33 31 30 28 26 25 24 21 20 20 17 16 16 14 2 32 29 26 24 30 27 24 22 22 20 19 18 17 15 14 13 12 10 3 29 25 22 19 27 23 20 18 19 17 15 16 14 12 12 11 10 8 4 27 22 19 16 24 20 17 15 17 14 13 14 12 10 11 9 8 7 5 24 19 16 13 22 18 15 12 15 12 11 12 10 9 10 8 7 6 6 22 17 14 11 20 16 13 11 13 11 9 11 9 8 9 7 6 5 7 21 15 12 10 19 14 11 9 12 10 8 10 8 7 8 6 5 4 8 19 14 11 9 17 13 10 8 11 9 7 9 7 6 7 6 5 4 9 18 13 10 8 16 12 9 7 10 8 6 8 6 5 7 5 4 3 10 17 12 9 7 15 11 8 6 9 7 5 8 6 5 6 5 4 3 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. NOTE: THE ZONAL CAVITY CALCULATION TECHNIQUE IS ACCURATE WHEN LUMINAIRES WITH SYMMETRIC CANDELA DISTRIBUTIONS ARE EMPLOYED AND WHEN THE LUMINAIRES ARE LOCATED SYMMETRICALLY THROUGHOUT THE ROOM. THIS UNIT HAS SPECIAL CHARACTERISTICS AND THEREFORE THESE COEFFICIENTS SHOULD BE USED WITH CAUTION.

REPORT NUMBER: ITL77175 PAGE: 5 OF 5 ADDENDUM -------- SPECIAL TEST PROCEDURES FOR T-5 LAMPS INCLUDING EXPLANATION OF THE IMPORTANCE OF LAMP LUMEN RATINGS. ------------------------------------------------------------------ This test was performed using standard relative photometric practices in accordance with recommendations of the Illuminating Engineering Society of North America. Fluorescent testing using the guidelines of relative photometric practice presupposes that the lamps will be operated at their nominal electrical characteristics (e.g., a 40 watt lamp will operate very nearly at 40 watts, and at the voltage and current required for 40-watt operation). Fluorescent lamps in general are temperature sensitive, the lumen output varies with ambient temperature and follows a characteristic curve. The T-5 fluorescent lamps used in this test produce maximum light output in an ambient temperature other than 25 degrees C. A critical step in relative photometric testing involves measurement of the total flux output from the lamp(s) suspended in free air at a 25 degree C ambient temperature per IES LM41-1998. This measurement process is a separate step from the photometric exploration of the luminaire itself. This "bare lamp" measurement is made with the lamp(s) operated by the same ballast(s) which are to be used in the luminaire. Since the test procedure involves measuring the bare lamp flux output at 25 degrees C and this lamp type peaks at a temperature other than 25 degrees C, the flux measured for this lamp type will be less than the maximum output the lamp is designed to produce. As a result, the measurement of the "bare lamp" total flux output is lower than it would be if the lamps were operated at their optimum operating temperature and at nominal electrical characteristics. When this "bare lamp" measurement is incorporated into the luminaire test report, the net effect is that total luminaire efficiency on the report is higher than what the lighting industry would expect this luminaire to produce. These lighting industry expectations are based on comparisons to the total luminaire efficiency of the same luminaire with T-12 or T-8 lamps. On this particular test, the lamp lumen rating shown is for a 25 degree C ambient temperature. Since this report was based on the lamp lumen rating at 25 degrees C, the candela values in this report should be accurate, as long as the lamp(s) used for this test follow the manufacturer s light output vs. temperature curve. T5TEMP3.DIS