Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Similar documents
PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-RHH/RHW-2 USE-2 Copper

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2


PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

MC, THHN/THWN-2 Copper

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

Mecklenburg County Common Code Defects

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

NEC 2014 Code Changes

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

MC or MV-105 Copper, TR-XLPE Insulated

Section 8. Portable Cordage & Power Cable

Omni Cable is a master distributor of specialty wire and cable selling

TUNNELING POWER CABLES

High Voltage Copper, Smooth Aluminum Shield/Sheath

E R C. R E R C ; ; W T E C

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

The Reliable Choice. Field Pocket Guide

KALAS ENTERTAINMENT CABLE

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

STABILOY BRAND FeeDeR SOLuTIONS

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

PART A General Conductor Requirements

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

MEDIUM VOLTAGE

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

ATHLETIC STADIUMS AND SPORTS ARENAS

Medium Voltage Cable. marmonutility.com

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme.

RENEWABLE ENERGY. Alcan cable solutions

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Hook-Up Wire Alpha Wire ALPHA 373

Medium Voltage Power Cables

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SECONDARY 600 VOLT CABLES

IEEE 1580 TYPE T/N CABLE

DLO. Mining Cable. Mining Cable. 2 kv

Section 11 Mining Cable

Battery Cables. Wire & Cable

Electrical Design/Build Guide

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

CABLED TWISTED PAIRS CONDUCTORS

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Primary, Secondary, Post-Secondary Education Facilities

Automotive Cables. The Global Cable Solutions Company

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

HOSPITAL AND HEALTHCARE

N2XY IEC XLPE PVC 0.6/1kV Cable

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

UNSHIELDED MULTI CONDUCTOR

CABLED SINGLE CONDUCTORS

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE

CHAPTER V RESIDENTIAL WIRING

2016 Photovoltaic Solar System Plan Review List

PHOTOVOLTAIC SYSTEMS

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

Photovoltaic Solar Plan Review

Airfield Ground Lighting

Category # 1 - Overhead, Primary, & Secondary Conductors

Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications

20 HUBER+SUHNER RADOX SOLAR

Your Partner in Safe Power Solutions. About RESCAB

Code Calculations. for an Off-Grid PV System

Type MMV-WP Medium Voltage Wind Power Cable

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

FLEX-O-POWER FLEXIBLE WELDING

Hook-Up Wire Cables you trust. Service you deserve.

DISCONTINUED PRODUCT POWER PROTECTION. Series 600 UPS. Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz. Installation Manual

Data sheet chainflex CFSOFT1

C-L-X Aluminum Sheath Type IEC

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

Wired for Power Generation

Detailed Specifications & Technical Data

High Reliability Power System Design

Transcription:

Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and produce a wide range of cables used in power, industrial, construction and communication applications. With more than a century of experience as a leader in the industrial and power cable markets, Nexans is contracted by heavy industry and utilities worldwide to provide turnkey solutions for the bulk transmission of power - from generating station through the transmission and distribution systems to commercial, residential and industrial areas. This catalog has been prepared for the convenience of those using electrical conductors in industrial, commercial and residential applications. The information included in the many tabulations will be of particular value to the architect, engineer, electrician, and layperson alike. For your convenience, we have referenced applicable Articles and Tables from both the 2008 NEC and the 2011 NEC. Although we have listed the types of wires and cables suitable for most conditions, we are equipped to manufacture other types to suit special needs. We would be pleased to recommend the most suitable construction for any special condition that you may encounter. The determination of the correct cable size and type, and the selection of methods of installation suitable for the type and location of particular circuits, should be made in accordance with local regulations. Any questions in this respect should be directed primarily to the local Electrical Inspection Authority. We are pleased to note that all the cables in this catalog are LEAD FREE. This indicates that the component has less than 300 ppm of lead, which is well below the 1000 ppm level indicated in RoHS (restriction of hazardous substances) regulations and below the level requiring labeling by California Proposition #65. Nexans wire and cable Contact us for all your wire and cable needs Nexans Energy USA inc. 25 Oakland Avenue Chester, NY 10918 Tel: www.nexans.us A t t h e c o r e o f p e r f o r m a n c e 1

ENERGEX Building Wire INTRODUCTION...Page 1 TABLE OF CONTENTS...Page 2 ENERGEX BARE COPPER...Page 3 ENERGEX TFN/TFFN Copper... Pages 4 & 5 ENERGEX THHN/THWN-2/MTW Copper... Pages 6 & 7 ENERGEX NM-B Copper... Pages 8 & 9 ENERGEX UF-B Copper.... Pages 10 & 11 ENERGEX XHHW-2 Copper.... Pages 12 & 13 ENERGEX 8000 XHHW-2 Aluminum... Pages 14 & 15 ENERGEX RHH/RHW-2/USE-2 Copper... Pages 16 & 17 ENERGEX 8000 RHH/RHW-2/USE-2 Aluminum... Pages 18 & 19 ENERGEX 8000 Mobile Home Feeder Aluminum... Pages 20 & 21 ENERGEX PV 600 Volt Copper... Pages 22 & 23 ENERGEX 8000 PV 600 Volt Aluminum... Pages 24 & 25 ENERGEX PV 2 kv Copper... Pages 26 & 27 ENERGEX 8000 PV 2 kv Aluminum... Pages 28 & 29 ENERGEX MC 120 Volt Copper.... Pages 30 & 31 ENERGEX MC 277 Volt Copper.... Pages 32 & 33 ENERGEX 8000 SER Aluminum... Pages 34 & 35 ENERGEX 8000 SEU Aluminum... Pages 36 & 37 ENERGEX URD Aluminum... Pages 38 & 39 WARRANTY & NOTES... Pages 40 2

Description Solid or stranded 100% conductivity copper conductors. ASTM B3 Soft or Annealed Copper Wire* ASTM B8 Concentric - Lay - Stranded Copper Conductors Application Used for bonding and grounding electrical circuits and systems. Soft Drawn Bare Copper UL Solid - ASTM B3 Stranded - ASTM B8 Conductor Number of Nominal Approximate Net Average D.C. Size Strands Diameter Cable Weight Resistance at 25 C AWG/kcmil inches mm lbs/kft kg/km Ω/kft Ω/km 14 1 0.0641 1.63 12.68 18.87 2.58 8.46 12 1 0.0808 2.05 20.16 30.00 1.63 5.53 10 1 0.101 2.59 32.06 47.72 1.02 3.35 8 7 0.142 3.61 50.97 75.86 0.640 2.10 6 7 0.178 4.52 81.05 120.6 0.403 1.32 4 7 0.225 5.72 128.9 191.8 0.253 1.05 2 7 0.283 7.19 204.9 304.9 0.159 0.659 1 19 0.322 8.18 258.4 384.6 0.127 0.522 1/0 19 0.362 9.19 325.8 484.9 0.100 0.328 2/0 19 0.405 10.29 410.9 611.5 0.0795 0.261 3/0 19 0.456 11.58 518.1 771.1 0.0630 0.207 4/0 19 0.512 13.00 653.1 972.0 0.0500 0.164 250 37 0.558 14.17 771.9 1149 0.0423 0.139 300 37 0.611 15.52 926.3 1379 0.0353 0.116 350 37 0.661 16.79 1081 1609 0.0302 0.0991 400 37 0.706 17.93 1235 1838 0.0264 0.0866 500 37 0.789 20.04 1544 2298 0.0212 0.0695 600 61 0.866 22.00 1883 2758 0.0177 0.0581 750 61 0.968 24.59 2316 3447 0.0141 0.0462 1000 61 1.117 28.37 3088 4596 0.0106 0.0348 Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. *ASTM B3 Specification details the requirements for solid wires and the individual wires in stranded conductors. 3

ENERGEX TFN/TFFN PVC Insulated Cable 600 Volts, 90 C - Lead Free Copper Conductors Applications Nexans ENERGEX TFN (solid) /TFFN (flexible stranded) copper conductors may be used as fixture wire, machine tool wire (MTW) or for appliance wiring material (AWM), as outlined in the NEC 2008 and NEC 2011. These conductors are heat, moisture, and gasoline and oil resistant II. TFN and TFFN are used for internal wiring of lighting fixtures and similar equipment, and for connection to branch circuit wiring inside lighting fixtures and similar equipment. TFN/TFFN is rated at a conductor temperature of 90 C in dry locations. MTW is used for internal wiring of machines tools, rated 90 C in dry locations and 60 C when exposed to oils or coolants. AWM is used as factory installed internal wiring of appliances, rated 105 C in dry locations. Nexans TFN/TFFN conductors are Lead Free and RoHS compliant. Construction Conductor: TFN - solid annealed soft bare copper per ASTM B3. TFFN/MTW/AWM - flexible stranded annealed soft bare copper per ASTM B174 Insulation: Color coded, heat, moisture and flame resistant polyvinyl chloride (PVC). Covering: Strong, slick polyamide (Nylon) outer covering, Colors: Standard TFN and TFFN colors available in black, white, red, blue, green, yellow, pink, purple, orange, brown and gray. Additional colors are made per request subject to factory minimum order quantities. Surface Print Legend: NEXANS-F 16 AWG (1.31 mm2) (UL) TFFN or MTW or AWM 600V VW-1 GASOLINE AND OIL RESISTANT II LEAD FREE MADE IN CANADA (MFG. DATE) Specifications Nexans ENERGEX TFN/TFFN meets or exceeds UL 66 (Fixture Wires) and the requirements of the National Electrical Code - Fixture wire. TFFN meets or exceeds UL 1063 (Machine-Tool Wires and Cables) for Machine Tool Wire and UL 758 (Appliance Wiring Materials) for AWM Style 1316. The insulation is heat, moisture, gasoline and oil resistant II. TFN/TFFN shall be lead free and RoHS compliant. Voltage rating - 600 Volts. Product Features Heat and moisture resistant Gasoline and oil resistant II Rated for use as appliance wiring Available from inventory in 11 colors Lead Free and RoHS compliant 4

PVC Insulated Cable 600 Volts, 90 C - Lead Free Copper Conductors ENERGEX TFN/TFFN UL 66 UL 1063 UL 758, Style 1316 Conductor PVC Insulation Nylon Nominal Approximate Net Ampacity Size Thickness Thickness Diameter Cable Weight (Amps) AWG mils mm mils mm inches mm lbs/kft kg/km TFN/TFFN MTW 1 @ 90 C TFN 18 (1) 15 0.38 4 0.10 0.081 2.05 7.1 10.6 6 16 (1) 15 0.38 4 0.10 0.094 2.39 10.6 15.8 8 TFFN / MTW 18 (16) 15 0.38 4 0.10 0.087 2.21 7.4 11.0 6 7 16 (26) 15 0.38 4 0.10 0.100 2.54 11.0 16.4 8 10 Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article 336.80, and Table 402.5 Allowable Ampacity for Fixture Wires at an ambient temperature of 30 C (with no load diversity). For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B) (16). Refer to NEC 2008 and NEC 2011 Article 240.4(D) for overcurrent protection requirements. 1 Allowable ampacities for MTW are as shown in NFPA 79. 5

ENERGEX THHN/ THWN-2/MTW PVC/Nylon Cable 600 Volts, 90 C - Lead Free Copper Conductors Applications Nexans ENERGEX THHN/THWN-2/ MTW* is a general purpose wiring product for use in power, lighting and control circuits. It can be used in conduit, ducts and trays for service feeders and branch circuits in industrial and commercial installations. When used in accordance with the 2008 or 2011 NEC, THHN/THWN-2 is suitable for use in wet and dry locations, at conductor temperatures not exceeding 90 C or for use in oil or coolants at conductor temperatures not exceeding 75 C. THHN/THWN-2 is gasoline and oil resistant II. When used as Machine Tool Wire (MTW) it is rated at 90 C in dry locations and 60 C in wet locations or when exposed to oil or coolants. Nexans THHN/THWN-2/MTW wire is Lead Free and RoHS compliant. * Only stranded cables are MTW listed per UL 1063. Construction Conductor: Solid bare, annealed copper per ASTM B3. Stranded bare annealed copper per ASTM B3 and ASTM B787 for sizes 14, 12, 10 and 8 AWG and ASTM B8 for sizes 6 AWG and larger. Insulation: Color coded polyvinyl chloride (PVC), heat, moisture and flame retardant compound per UL 83 and UL 1063 Covering: A tough abrasion resistant polyamide (Nylon) covering Surface Print Legend: NEXANS- C 500 kcmil (253mm2) TYPE MTW OR THHN OR THWN-2 GRII SR FOR CT USE VW-1 600V (UL) LEAD FREE (MFG. DATE) Specifications Nexans ENERGEX THHN/THWN- 2 or MTW meets or exceeds all applicable ASTM specifications UL 83: Thermoplastic Insulated Wires and Cables UL 1063: Machine-Tool Wires and Cables (stranded cables only) Nema WC70 / ICEA S-95-658: Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Federal Specification A-A-59544 and requirements of the NEC CSA C22.2 No. 75: Thermoplastic Insulated Wires and Cables 14 AWG through 750 kcmil are rated VW-1 Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Black sizes 1/0 AWG and larger are sunlight resistant Voltage rating - 600 volts. Product Features Sizes 8 AWG to 600 kcmil available in various colors from stock Cables are UL listed as Type THHN/ THWN-2/MTW* Meets UL VW-1 flame test requirements Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Black 1/0 AWG and larger is sunlight resistant High heat and moisture resistant THWN-2 90 C rated for dry and wet locations Gasoline and Oil Resistant II Small diameter for improved conduit fill Lead Free and RoHS compliant Packaging 14 & 12 AWG: 4 x 500 spools (2000 per carton) or 2500 reel 10 AWG: 2 x 500 spools (1000 per carton) or 2500 reel 8 AWG - 4/0 kcmil: 500, 1000, 2500 or 5000 reel 250 kcmil - 600 kcmil: 500, 1000, or 2500 reel 750 kcmil: 1000 reel 6

PVC/Nylon Cable 600 Volts, 90 C - Lead Free Copper Conductors ENERGEX THHN/ THWN-2/MTW UL 83 / CSA C22.2 No. 75 UL 1063 ICEA S-95-658 Conductor PVC Insulation Nylon Nominal Diameter Approximate Net Ampacity* Size Thickness Thickness Cable Weight (Amps) AWG/kcmil mils mm mils mm inches mm lbs/kft kg/km 60 C 75 C 90 C 14 (1) 15 0.38 4 0.10 0.11 2.8 15 22.3 15 15 15 12 (1) 15 0.38 4 0.10 0.12 3.1 23 34.2 20 20 20 10 (1) 20 0.51 4 0.10 0.15 3.8 37 53.6 30 30 30 14 (19) 15 0.38 4 0.10 0.11 2.8 16 23.8 15 15 15 12 (19) 15 0.38 4 0.10 0.13 3.8 24 35.7 20 20 20 10 (19) 20 0.51 4 0.10 0.17 4.3 39 58.0 30 30 30 8 (19) 30 0.76 5 0.13 0.22 5.6 63 93.7 40 50 55 6 (19) 30 0.76 5 0.13 0.26 6.6 98 145 55 65 75 4 (19) 40 1.01 6 0.15 0.33 8.4 157 234 70 85 95 3 (19) 40 1.01 6 0.15 0.36 9.1 193 287 85 100 110 2 (19) 40 1.01 6 0.15 0.39 9.9 240 357 95 115 130 1 (19) 50 1.27 7 0.18 0.43 10.9 300 446 110 130 150 1/0 (19) 50 1.27 7 0.18 0.47 12.0 376 560 125 150 170 2/0 (19) 50 1.27 7 0.18 0.52 13.2 467 695 145 175 195 3/0 (19) 50 1.27 7 0.18 0.57 14.5 581 864 165 200 225 4/0 (19) 50 1.27 7 0.18 0.64 16.0 724 1077 195 230 260 250 (37) 60 1.52 8 0.20 0.69 17.4 855 1272 215 255 290 300 (37) 60 1.52 8 0.20 0.76 19.3 1022 1521 240 285 320 350 (37) 60 1.52 8 0.20 0.79 20.1 1191 1772 260 310 350 400 (37) 60 1.52 8 0.20 0.85 21.6 1345 2001 280 335 380 500 (37) 60 1.52 8 0.20 0.94 23.9 1668 2482 320 380 430 600 (61) 70 1.78 9 0.23 1.10 27.9 1994 2967 355 420 475 750 (61) 70 1.78 9 0.23 1.16 29.5 2465 3668 400 475 535 *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. For MTW in wet locations or when exposed to oil or coolant. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. THWN-2 when exposed to oil or coolant. 90 C - THHN dry locations. THWN-2 wet or dry locations. For ampacity derating purposes. Available colors: Black, White, Red, Blue, Green, Yellow, Brown, Orange, Purple, Gray, Pink. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article 310.15, which are based on NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 7

ENERGEX NM-B PVC/Nylon Insulated Cable 600 Volts, 90 C Dry - Lead Free Copper Conductors Applications Nexans ENERGEX non-metallic sheathed cable NM-B is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90 C dry, its ampacity is limited to 60 C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. Nexans NM-B cables are Lead Free and RoHS compliant. Construction Conductor: Solid 14 to 10 AWG annealed soft bare copper per ASTM B3. Stranded 8 AWG and larger annealed soft bare copper per ASTM B3 and B8. Insulation: Color coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90 C. Ground: Soft, bare copper solid per ASTM B3 and stranded per ASTM B3 and B8 Sheath: 30 mil color coded PVC sheath rated 90 C is applied over the completed assembly: White 14 AWG Yellow 12 AWG Orange 10 AWG Black 8 to 2 AWG Surface Print Legend: NEXANS-C ENERGEX 2C-14 AWG TYPE NM-B 600V W/GRD (UL) LEAD FREE MM/ DD/YY MADE IN U.S.A. Specifications Nexans ENERGEX NM-B meets or exceeds all applicable ASTM specifications. UL 83: Thermoplastic Insulated Wires and Cables UL 719: Non-Metallic Cables Federal Specification A-A-59544 and requirements of the NEC. Voltage rating - 600 volts. Product Features Slick proprietary sheathing material designed for ease of installation Color coded sheaths designed for quick cable identification Lead free and RoHS compliant 14 AWG 2C and 12 AWG 2C available with two neutral conductors Packaging 14, 12 & 10 AWG; 2, 3 and 4 conductor - 250 ft coil and 1000 ft reel 8 AWG and larger 2 and 3 conductor - 125 ft coil, 500 and 1000 ft reel 8

PVC/Nylon Insulated Cable 600 Volts, 90 C Dry - Lead Free Copper Conductors ENERGEX NM-B UL 83 UL 719 Conductor # of PVC Insulation Ground Nylon Nominal Cable Approximate Net Ampacity Size Conductors Thickness Wire Size Thickness Dimensions Cable Weight (Amps) AWG mils mm AWG mils mm inches mm lbs/kft kg/km Two Conductor 14 (1) 2 15 0.38 14 (1) 4 0.10 0.16 x 0.36 4.0 x 9.1 57 85 15 12 (1) 2 15 0.38 12 (1) 4 0.10 0.17 x 0.40 4.3 x 10.2 82 122 20 10 (1) 2 20 0.51 10 (1) 4 0.10 0.21 x 0.49 5.3 x 12.4 124 185 30 8 (7) 2 30 0.76 10 (1) 5 0.13 0.27 x 0.59 6.9 x 15.0 186 277 40 6 (7) 2 30 0.76 10 (1) 5 0.13 0.32 x 0.68 8.1 x 17.3 255 379 55 Three Conductor 14 (1) 3 15 0.38 14 (1) 4 0.10 0.31 7.9 74 110 15 12 (1) 3 15 0.38 12 (1) 4 0.10 0.34 8.6 107 159 20 10 (1) 3 20 0.51 10 (1) 4 0.10 0.43 10.9 163 243 30 8 (7) 3 30 0.76 10 (1) 5 0.13 0.56 14.2 254 378 40 6 (7) 3 30 0.76 10 (1) 5 0.13 0.63 16.0 357 531 55 4 (7) 3 40 1.02 8 (7) 6 0.15 0.85 21.6 593 882 70 2 (7) 3 40 1.02 6 (7) 6 0.15 0.98 24.9 856 1274 95 Four Conductor 14 (1) 2/2 1 15 0.38 14 (1) 4 0.10 0.35 8.9 91 135 15 14 (1) 4 2 15 0.38 14 (1) 4 0.10 0.35 8.9 91 135 15 12 (1) 2/2 1 15 0.38 12 (1) 4 0.10 0.38 9.7 132 196 20 12 (1) 4 2 15 0.38 12 (1) 4 0.10 0.38 9.7 132 196 20 Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Articles 310.15 and 334.80, which are based on NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature and 60 C rated conductors. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B) (16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4 (E) through (G) 1 Insulation color code for 2 / 2 conductor cable is Black, White, Red, and White with Red stripe. Cable ampacity is based on the White and White with Red stripe conductors being connected as the neutrals for the system. 2 Insulation color code for 4 conductor cable is Black, White, Red and Blue. Cable ampacity is based on the 4th conductor being connected as the neutral conductor of a balanced 3 phase system. 9

ENERGEX UF-B PVC/Nylon Insulated Cable 600 Volts, 90 C Dry - Lead Free Copper Conductors Applications Nexans ENERGEX UF-B is an underground feeder and branch circuit wiring cable. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90 C dry / wet its ampacity is limited to 60 C according to the NEC 2008 and NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 or NEC 2011 Article 334. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Nexans UF-B cables are Lead Free and RoHS compliant. Construction Conductor: Solid annealed soft bare copper per ASTM B3. Stranded annealed soft bare copper per ASTM B3 and ASTM B8. Insulation: Polyvinyl chloride (PVC) with a nylon covering. Color coded phase identification. Ground: Soft bare copper, solid per ASTM B3 and stranded per ASTM B3 and ASTM B8. Jacket: Sunlight, moisture and fungus resistant gray PVC. Surface Print Legend: NEXANS-C ENERGEX 2C-14 AWG W/GRND TYPE UF-B SUN RES 600V (UL) LEAD FREE MM/DD/YY MADE IN U.S.A. Specifications Nexans ENERGEX UF-B meets or exceeds all applicable ASTM specifications. UL 83: Thermoplastic Insulated Wires and Cables UL 493: Thermoplastic-Insulated Underground Feeder and Branch Circuit Cables Federal Specification A-A-59544 and requirements of the NEC. Voltage rating - 600 volts. Product Features Slick proprietary jacketing compound designed for quick and easy installation Gray jacket designed for quick cable identification Lead free and RoHS compliant Meets or exceeds all applicable industry standards Packaging 14, 12 & 10 AWG; 2, 3 and 4 conductor: 250 ft coil and 1000 ft reel 8 & 6 AWG; 2 and 3 conductor: 125 ft coil and 500 ft reel Bar coded reels and coils for ease of material handling 10

ENERGEX UF-B UL 83 UL 493 PVC/Nylon Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors Conductor PVC Insulation Nylon PVC Jacket Ground Nominal Cable Approximate Net Ampacity Size Thickness Thickness Thickness Wire Size Dimensions Cable Weight (Amps) AWG mils mm mils mm mils mm AWG inches mm lbs/kft kg/km Two Conductor With Ground 14 (1) 15 0.38 4 0.10 30 0.76 14 (1) 0.18 x 0.36 4.6 x 9.2 55 82 15 12 (1) 15 0.38 4 0.10 30 0.76 12 (1) 0.19 x 0.39 4.8 x 9.9 75 112 20 10 (1) 20 0.51 4 0.10 30 0.76 10 (1) 0.22 x 0.45 5.6 x 11.4 140 208 30 8 (7) 30 0.76 5 0.13 45 1.14 10 (1) 0.31 x 0.68 7.9 x 17.3 213 317 40 6 (7) 30 0.76 5 0.13 45 1.14 10 (1) 0.34 x 0.78 8.6 x 19.8 305 454 55 Three Conductor With Ground 14 (1) 15 0.38 4 0.10 30 0.76 14 (1) 0.18 x 0.58 4.6 x 14.7 93 138 15 12 (1) 15 0.38 4 0.10 30 0.76 12 (1) 0.19 x 0.62 4.8 x 15.7 134 200 20 10 (1) 20 0.51 4 0.10 30 0.76 10 (1) 0.22 x 0.67 5.6 x 17.0 194 289 30 8 (7) 30 0.76 5 0.13 45 1.14 10 (1) 0.32 x 0.99 8.1 x 25.1 330 491 40 6 (7) 30 0.76 5 0.13 45 1.14 10 (1) 0.38 x 1.20 9.7 x 30.5 449 668 55 Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Articles 310.15 and 334.80, which are based on NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature and 60 C rated conductors. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 11

ENERGEX XHHW-2 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors Applications Nexans ENERGEX XHHW-2 is a copper conductor, with crosslinked polyethylene insulation. The cable is rated at 600 volts and 90 C for use in wet and dry locations. XHHW-2 can be used in conduit and other raceways for services, feeders and other applications recognized by the NEC 2008 and NEC 2011. Sizes 14 to 4/0 AWG are approved as Type SIS. Sizes 1/0 AWG and larger (4 AWG and larger in green) in all colors are cable tray (CT) rated. Nexans XHHW-2 conductors are Lead Free. Construction Conductor: Annealed soft bare copper per ASTM B3, B787 and B8 Insulation: Cross-linked polyethylene (XLPE) insulation per UL 44 Surface Print Legend: NEXANS EXELENE 500 kcmil (253 mm2) XHHW- 2 (UL) E64801 F 600V FOR CT USE SR - MADE IN CANADA LEAD FREE (MFG. DATE) Specifications Nexans ENERGEX Type XHHW- 2 meets or exceeds all applicable ASTM specifications. UL 44: Thermoset-Insulated Wires and Cables Federal Specification A-A-59544 and the requirements of the NEC. NEMA WC70 / ICEA S-95-658: Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use. Sunlight resistant in black 8 AWG and larger. 14 to 10 AWG are available in 10 distinct colors for identification purposes. Sizes 14 to 4/0 AWG rated SIS. Nexans XHHW-2 is lead free. Voltage rating - 600 Volts. Product Features Sizes 14, 12 and 10 AWG are available in 10 colors: Black, White, Red, Blue, Green, Yellow, Brown, Orange, Gray, Purple. Size 8 AWG and larger in black only. Meets IEEE 1202 Conforms to ICEA S-95-658 Sunlight Resistant 8 AWG and larger in black Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Sizes 14 to 4/0 AWG rated SIS Meets or exceeds all applicable industry standards Lead Free Packaging 14 to 10 AWG 2 x 500 spools (1000 feet) per carton; 2500 reel 8 AWG - 600 kcmil long length 750 kcmil 500 reel or long length 12

XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors ENERGEX XHHW-2 UL 44 ICEA S-95-658 Conductor Insulation Thickness Nominal Diameter Approximate Net Ampacity* Size Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 14 (7) 30 0.76 0.13 3.4 18 27 15 15 15 12 (7) 30 0.76 0.15 3.8 26 39 20 20 20 10 (7) 30 0.76 0.17 4.5 40 60 30 30 30 8 (7) 45 1.14 0.24 6.0 64 95 40 50 55 6 (7) 45 1.14 0.27 6.9 97 144 55 65 75 4 (7) 45 1.14 0.32 8.2 149 222 70 85 95 2 (7) 45 1.14 0.38 9.6 230 342 95 115 130 1 (19) 55 1.40 0.43 10.9 288 429 110 130 150 1/0 (19) 55 1.40 0.48 12.1 360 536 125 150 170 2/0 (19) 55 1.40 0.52 13.2 456 679 145 175 195 3/0 (19) 55 1.40 0.56 14.2 563 838 165 200 225 4/0 (19) 55 1.40 0.61 15.6 703 1046 195 230 260 250 (37) 65 1.65 0.68 17.1 837 1245 215 255 290 300 (37) 65 1.65 0.75 18.9 995 1481 240 285 320 350 (37) 65 1.65 0.80 20.2 1155 1719 260 310 350 400 (37) 65 1.65 0.84 21.4 1324 1970 280 335 380 500 (37) 65 1.65 0.93 23.5 1643 2445 320 380 430 600 (61) 80 2.03 1.04 26.3 1986 2955 355 420 475 700 (61) 80 2.03 1.10 27.9 2283 3397 385 460 520 750 (61) 80 2.03 1.14 28.8 2467 3671 400 475 535 1000 (61) 80 2.03 1.29 32.7 3230 4806 455 545 615 *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C - Wet or dry locations. For ampacity derating purposes. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article 310.15, which are based on NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B) (16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 13

ENERGEX 8000 Type XHHW-2 XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free ACM Aluminum Conductors Applications Nexans ENERGEX 8000 XHHW-2 is an AA-8000 series aluminum (ACM) conductor with cross-linked polyethylene insulation. The cable is rated at 600 volts and 90 C for use in wet and dry locations. XHHW-2 can be used in conduit and other raceways for services, feeders and other applications recognized by the NEC 2008 and NEC 2011. Sizes 12 to 4/0 AWG are approved as SIS. Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use. Nexans XHHW-2 is lead free. Construction Conductor: compact stranded AA-8000 series aluminum alloy per ASTM B800 and B801 Insulation: black sunlight resistant, cross-linked polyethylene (XLPE) meeting the requirements for XHHW-2 per UL 44. Specifications Nexans ENERGEX 8000 XHHW-2 meets or exceeds all applicable ASTM specifications. UL 44: Thermoset-Insulated Wires and Cables NEC 2008 Article 310.13 or NEC 2011 Article 310.104 Federal Specification A-A-59544 and the requirements of the NEC. NEMA WC7O / ICEA S-95-658: Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Sunlight Resistant 8 AWG and larger in black Sizes 12 to 4/0 AWG rated SIS Voltage rating - 600 Volts. Meets IEEE 1202 Product features Cables are UL listed as Type XHHW-2 Temperature rating of 90 C dry and wet Sunlight Resistant, black 8 AWG and larger Lead Free Bare conductors are heat treated after stranding for maximum flexibility Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Sizes 12 to 4/0 AWG rated SIS Surface Print Legend: NEXANS-C 1/0 AWG COMPACT AA- 8000-AL XHHW-2 600V FOR CT USE SR LEAD FREE (UL) (MFG. DATE) 14

XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free ACM Aluminum Conductors ENERGEX 8000 Type XHHW-2 UL 44 ICEA S-95-658 Conductor Insulation Nominal Approximate Net Ampacity* Size Thickness Diameter Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 6 (7) 45 1.14 0.26 6.6 40 59 40 50 55 4 (7) 45 1.14 0.31 7.9 57 85 55 65 75 2 (7) 45 1.14 0.36 9.1 84 125 75 90 100 1 (18) 55 1.40 0.42 10.7 108 161 85 100 115 1/0 (18) 55 1.40 0.45 11.4 131 196 100 120 135 2/0 (18) 55 1.40 0.49 12.4 161 239 115 135 150 3/0 (18) 55 1.40 0.54 13.7 198 294 130 155 175 4/0 (18) 55 1.40 0.59 15.0 243 361 150 180 205 250 (35) 65 1.65 0.66 16.8 292 434 170 205 230 300 (35) 65 1.65 0.71 18.0 352 524 195 230 260 350 (35) 65 1.65 0.75 19.1 394 586 210 250 280 400 (35) 65 1.65 0.80 20.3 446 663 225 270 305 500 (35) 65 1.65 0.87 22.1 548 815 260 310 350 600 (58) 80 2.03 0.98 24.9 670 997 285 340 385 700 (58) 80 2.03 1.04 26.4 787 1171 315 375 425 750 (58) 80 2.03 1.08 27.4 822 1224 320 385 435 *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 12 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C - Wet or dry locations. For ampacity derating purposes. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article 310.15, which are based on NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16) for aluminum conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B) (16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 15

XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors ENERGEX RHH/RHW-2/USE-2 Applications Nexans ENERGEX RHH/RHW-2/ USE-2 conductors may be installed in raceways and conduits or directly buried. They are 90 C, 600 volts per NEC 2008 and NEC 2011 Articles 310 and 338. Type USE-2 conductors are suitable as service entrance conductors which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, they are suitable for installation in both wet and dry locations. Nexans RHH/RHW-2/USE-2 conductors are Lead Free. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation per UL 854 and UL 44. Black only. Surface Print Legend: NEXANS 1/0 AWG (53.5 mm2) (UL) E64801 F RHW-2 OR USE-2 600V FOR CT USE SR MADE IN CANADA LEAD FREE (MFG DATE). Specifications Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854: (USE-2) Service Entrance Cables Federal Specification A-A-59544 ICEA S-95-658: Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy National Electrical Code - NFPA 70 Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Product Features Cables are UL listed as Type USE-2 Temperature rating of 90 C dry and wet Suitable for direct burial Sunlight resistant Lead Free 16

XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors ENERGEX RHH/RHW-2/USE-2 UL 44 UL 854 ICEA S-95-658 Conductor Insulation Thickness Nominal Diameter Approximate Net Ampacity* Size Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 14 (1) 45 1.14 0.16 4.0 21 31 15 15 15 12 (1) 45 1.14 0.17 4.4 30 44 20 20 20 10 (1) 45 1.14 0.19 4.9 44 65 30 30 30 14 (7) 45 1.14 0.16 4.1 21 31 15 15 15 12 (7) 45 1.14 0.18 4.7 30 44 20 20 20 10 (7) 45 1.14 0.21 5.2 44 65 30 30 30 8 (7) 60 1.52 0.27 6.8 70 105 40 50 55 6 (7) 60 1.52 0.31 7.8 104 156 55 65 75 4 (7) 60 1.52 0.35 8.9 157 234 70 85 95 2 (7) 60 1.52 0.41 10.4 240 357 95 115 130 1 (19) 80 2.03 0.49 12.4 309 460 110 130 150 1/0 (19) 80 2.03 0.53 13.4 379 564 125 150 170 2/0 (19) 80 2.03 0.57 14.5 474 706 145 175 195 3/0 (19) 80 2.03 0.61 15.4 583 869 165 200 225 4/0 (19) 80 2.03 0.68 17.2 755 1124 195 230 260 250 (37) 95 2.41 0.74 18.7 867 1291 215 255 290 300 (37) 95 2.41 0.81 20.5 1029 1531 240 285 320 350 (37) 95 2.41 0.86 21.8 1192 1773 260 310 350 400 (37) 95 2.41 0.90 22.9 1352 2012 280 335 380 500 (37) 95 2.41 0.99 25.1 1686 2509 320 380 430 600 (61) 110 2.79 1.09 26.4 2012 2995 355 420 475 700 (61) 110 2.79 1.16 29.5 2332 3470 385 460 520 750 (61) 110 2.79 1.20 30.4 2492 3710 400 475 535 1000 (61) 110 2.79 1.35 34.2 3288 4895 455 545 615 *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90 C - RHH dry locations. RHW-2 and USE-2 wet or dry locations. For ampacity derating purposes. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article 310.15, which are based on NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B) (16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 17

XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free ACM Aluminum Conductors ENERGEX 8000 RHH/RHW-2/USE-2 Applications Nexans ENERGEX RHH/RHW-2/ USE-2 conductors may be installed in raceways and conduits or directly buried. They are 90 C, 600 volts per NEC 2008 and NEC 2011 Articles 310 and 338. Type USE-2 conductors are suitable as service entrance conductors which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, they are suitable for installation in both wet and dry locations. Nexans RHH/RHW-2/USE-2 conductors are Lead Free. Construction Conductor: compact stranded AA-8000 series aluminum alloy per ASTM B800 and B801 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation per UL 854 and UL 44. Black only. Surface Print Legend: NEXANS-C 1/0 AWG COMPACT AA-8000-AL USE-2 OR RHH OR RHW-2 600V FOR CT USE SUN RES (UL) LEAD FREE (MFG. DATE) Specifications Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854: (USE-2) Service Entrance Cables Federal Specification A-A-59544 ICEA S-95-658: Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy National Electrical Code - NFPA 70 Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use Product Features Cables are UL listed as Type USE-2 Temperature rating of 90 C dry and wet Suitable for direct burial Sunlight resistant Lead Free Bare conductors are heat treated after stranding for maximum flexibility 18

XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free ACM Aluminum Conductors ENERGEX 8000 RHH/RHW-2/USE-2 UL 44 UL 854 ICEA S-95-658 Conductor Insulation Thickness Nominal Diameter Approximate Net Ampacity* Size Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 6 (7) 60 1.52 0.29 7.4 47 70 40 50 55 4 (7) 60 1.52 0.33 8.4 66 98 55 65 75 2 (7) 60 1.52 0.39 9.9 96 143 75 90 100 1 (18) 80 2.03 0.46 11.7 127 189 85 100 115 1/0 (18) 80 2.03 0.50 12.7 152 226 100 120 135 2/0 (18) 80 2.03 0.54 13.7 182 271 115 135 150 3/0 (18) 80 2.03 0.59 15.0 222 330 130 155 175 4/0 (18) 80 2.03 0.64 16.3 271 403 150 180 205 250 (35) 95 2.41 0.71 18.0 328 488 170 205 230 300 (35) 95 2.41 0.76 19.3 385 573 195 230 260 350 (35) 95 2.41 0.81 20.6 435 647 210 250 280 400 (35) 95 2.41 0.85 21.6 494 735 225 270 305 500 (35) 95 2.41 0.93 23.6 600 893 260 310 350 600 (58) 110 2.79 1.07 27.2 721 1073 285 340 385 700 (58) 110 2.79 1.11 28.2 828 1232 315 375 425 750 (58) 110 2.79 1.13 28.7 899 1338 320 385 435 1000(58) 110 2.79 1.28 32.5 1141 1698 375 445 500 *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 12 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90 C - RHH dry locations. RHW-2 and USE-2 wet or dry locations. For ampacity derating purposes. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC 2008 and NEC 2011 Article 310.15, which are based on NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B) (16). NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). 19

XLPE Insulated Cable 600 Volts, 90 C Dry and Wet - Lead Free ACM Aluminum Conductors ENERGEX 8000 Mobile Home Feeder Applications Nexans ENERGEX Mobile Home Feeder is a twisted assembly of RHH / RHW-2 / USE-2 insulated aluminum conductor material (ACM), AA-8000 series alloy conductors. The cable is used as a service cable to feed mobile homes in parks and permanent locations. ENERGEX 8000 Mobile Home Feeders are designed to be directly buried. The cable is rated at 600 volts and 90 C for use in wet and dry locations in accordance with NEC 2008 and NEC 2011 Article 550.33. Nexans Mobile Home Feeder cables are Lead Free. Construction Conductor: compact stranded AA-8000 series aluminum alloy per ASTM B800 and B801 Insulation: solid color-coded sunlight resistant cross-linked polyethylene (XLPE) Assembly: black and red conductors are cabled with the white neutral conductor and green equipment grounding conductor. Surface Print Legend: NEXANS-C 4/0 AWG COMPACT AA- 8000-AL USE-2 OR RHH OR RHW-2 600V SUN RES LEAD FREE (UL) (MFG. DATE) Specifications Meets UL 854: Service Entrance Cables Meets UL 44: Thermoset-Insulated Wires and Cables Product features Cables are UL listed as Service Entrance Cable Solid color insulation Temperature rating of 90 C dry and wet Sunlight Resistant Lead Free Bare conductors are heat treated after stranding for maximum flexibility 20

XLPE Insulated Cable 600 Volts, 90 C Dry and Wet - Lead Free ACM Aluminum Conductors ENERGEX 8000 Mobile Home Feeder UL 854 UL 44 Insulation Thickness Insulation Thickness Insulation Thickness Cable Approximate Net Ampacity* Cable Construction Phase Conductors Neutral Conductor Grounding Conductor Diameter Cable Weight (Ph 1 + Ph 2 + N + G) mils mm mils mm mils mm inches lb/mft kg/km Amps 2 + 2 + 4 + 6 60 1.52 60 1.52 60 1.52 0.94 301 448 100 4/0 + 4/0 + 2/0 + 4 80 2.03 80 2.03 60 1.52 1.53 794 1182 200 Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. * Ampacities are in accordance with NEC 2008 Table 310.15(B)(6) or NEC 2011 Table 310.15(B)(7) and are based on 90 C conductor temperatures, 20 C ambient earth temperature, earth thermal resistivity Rho=90, cables buried 36 deep, only the phase conductors carrying current and 100% load factor. 21

XLPE Insulated Cable 600 Volts, 90 C Dry and Wet - Lead Free Copper Conductors ENERGEX PV/RHH/RHW-2/USE-2 Applications Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Nexans ENERGEX PV/RHH/RHW-2/ USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90 C, 600 V per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, they are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Surface Print Legend: (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) (UL) RHW-2 OR USE-2 OR PV WIRE 600V 90C WET OR DRY SR DIR BUR LEAD FREE Specifications Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A-59544 National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use UL File Numbers: E338981 (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Product features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90 C dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use LEAD FREE Options Class C stranding available 22

XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Copper Conductors ENERGEX PV/RHH/RHW-2/USE-2 UL 44 UL 854 UL 854 subject 4703 ICEA S-95-658 Conductor Insulation Thickness Nominal Diameter Approximate Net Ampacity* Size Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 8 (7) 75 1.91 0.29 7.5 76 113 40 50 55 6 (7) 75 1.91 0.33 8.4 110 164 55 65 75 4 (7) 75 1.91 0.38 9.6 164 244 70 85 95 2 (7) 75 1.91 0.44 11.0 248 369 95 115 130 1 (19) 95 2.41 0.51 12.9 316 470 110 130 150 1/0 (19) 95 2.41 0.55 13.9 390 580 125 150 170 2/0 (19) 95 2.41 0.59 15.0 481 716 145 175 195 3/0 (19) 95 2.41 0.64 16.2 596 887 165 200 225 4/0 (19) 95 2.41 0.69 17.6 740 1101 195 230 260 250 (37) 110 2.79 0.77 19.5 884 1316 215 255 290 300 (37) 110 2.79 0.82 20.8 1048 1560 240 285 320 350 (37) 110 2.79 0.87 22.0 1207 1796 260 310 350 400 (37) 110 2.79 0.91 23.1 1375 2046 280 335 380 500 (37) 110 2.79 0.99 25.1 1700 2530 320 380 430 600 (61) 125 3.18 1.10 27.8 2048 3048 355 420 475 700 (61) 125 3.18 1.19 30.2 2378 3539 385 460 520 750 (61) 125 3.18 1.22 31.0 2542 3783 400 475 535 1000 (61) 125 3.18 1.37 34.8 3347 4981 455 545 615 *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 8 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90 C - RHH dry locations. PV, RHW-2 and USE-2 wet or dry locations. For ampacity derating purposes. Allowable ampacities shown are for general use as specified by the NEC, Section 310.15. For conductors installed in conduit on a rooftop, use the derating factors specified by Table 310.15(B)(3)(c) in the NEC. Note: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. 23

XLPE Insulated Cable 600 Volts, 90 C Dry and Wet - Lead Free Aluminum Conductors ENERGEX 8000 PV/RHH/RHW-2/USE-2 Applications Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Nexans ENERGEX PV/RHH/RHW-2/ USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 600 V per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, they are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Compact stranded AA- 8000 series aluminum alloy (ACM) per ASTM B801 or B836 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Surface Print Legend: (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) CPT ACM ALUM (UL) RHW-2 OR USE-2 OR PV WIRE 600V 90C WET OR DRY SR DIR BUR LEAD FREE Specifications Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A-59544 National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use UL File Numbers: E338981 (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Product features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90 C dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use LEAD FREE Options Class C stranding available 24

XLPE Insulated Cable 600 Volts, 90 C Dry or Wet - Lead Free Aluminum Conductors ENERGEX 8000 PV/RHH/RHW-2/USE-2 UL 44 UL 854 UL 854 subject 4703 ICEA S-59-658 Conductor Insulation Thickness Nominal Diameter Approximate Net Ampacity* Size Cable Weight (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 C 75 C 90 C 6 (7) 75 1.91 0.32 8.2 52 77 40 50 60 4 (7) 75 1.91 0.37 9.3 72 107 55 65 75 2 (6) 75 1.91 0.42 10.7 102 151 75 90 100 1 (8) 95 2.41 0.49 12.5 135 201 85 100 115 1/0 (10) 95 2.41 0.53 13.4 161 240 100 120 135 2/0 (12) 95 2.41 0.57 14.5 193 288 115 135 150 3/0 (16) 95 2.41 0.62 15.6 231 344 130 155 175 4/0 (18) 95 2.41 0.67 17.0 282 420 150 180 205 250 (35) 110 2.79 0.74 18.9 344 512 170 205 230 300 (35) 110 2.79 0.79 20.2 401 596 190 230 255 350 (35) 110 2.79 0.84 21.3 456 679 210 250 280 400 (35) 110 2.79 0.88 22.4 512 762 225 270 305 500 (35) 110 2.79 0.96 24.4 621 925 260 310 350 600 (58) 125 3.18 1.07 27.1 755 1124 285 340 385 750 (58) 125 3.18 1.16 29.5 918 1367 320 385 435 1000 (58) 125 3.18 1.31 33.4 1195 1778 375 445 500 *60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 8 through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90 C - RHH dry locations. PV, RHW-2 and USE-2 wet or dry locations. For ampacity derating purposes. Allowable ampacities shown are for general use as specified by the NEC, Section 310.15. For conductors installed in conduit on a rooftop, use the derating factors specified by Table 310.15(B)(3)(c) in the NEC. Note: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. 25

XLPE Insulated Cable 2 kv, 90 C Dry and Wet - Lead Free Copper Conductors ENERGEX PV/RHH/RHW-2/USE-2 Applications Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Nexans ENERGEX PV/RHH/RHW-2/ USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 2 kv per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, they are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Surface Print Legend: (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) (UL) USE-2 600V OR RHW-2 OR PV WIRE 2000V 90C WET OR DRY SR DIR BUR LEAD FREE Specifications Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A-59544 National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use UL File Numbers: E338981 (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Product features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90 C dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 AWG and larger (4 AWG and larger in green) are rated for CT use LEAD FREE Options Class C stranding available 26