Model Number Structure

Similar documents
(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Model Number Structure

Model Number Structure

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Model Number Structure

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

G3PE-Single-phase. Solid State Relays for Heaters

Solid State Relays for Heaters

Solid State Relays G3NA. Model Number Structure. Model Number Legend

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output.

G3PE-Single-phase. Solid State Relays for Heaters

Model Number Structure

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

G3NA. Model Number Structure. Solid State Relays. Model Number Legend

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

High-power Solid State Relays G3PH

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Model Number Structure

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Surface mounting, flush mounting, and DIN track mounting

Model Number Structure

High-power Solid State Relays G3PH

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Ordering Information. Text PCB Power Relay G5LE

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Power Controller. (see note 1) 10 sec

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Slim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Solid State Relays for Heaters

H3DS-X - Solid State Two-Wire Timer

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Model Number Structure

Inductive Proximity Sensor

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Switching Power Supply

A22NK. Key-type Selector Switches

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Subminiature Basic Switch

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Analog Output Terminal

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

Analog Input Terminal

Switching Power Supply

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Model Number Structure

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Digital display Pressure range ON/OFF output Linear output Model

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute)

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

General Purpose Relay

General Purpose Relay

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

SYSMAC Transistor Remote Module

Ordering Information. Text Surface-Mounting Signal Relay G6K

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

G3RV-SL Slim I/O Relay will be discontinued February 2019

E2EZ-X2D1-N E2EZ-X2D2-N

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Type Terminal Coil Contact form Model

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Solid State Relays, 3-phase

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Inductive Proximity Sensor

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

HEAVY DUTY POWER RELAYS FEATURES

SOLSTART Instruction Manual

Transcription:

Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved by optimizing heat sink shape. DIN track mounting possible in addition to screw mounting. Comply with EN60947-4-3 (IEC947-4-3) UL508, and CSA22.2 No. 14, and bear CE marking. Model Number Structure Model Number Legend @@@-@@-@ 1 2 3 4 5 6 7 1. Basic Model Name G3PB: Solid State Relay 2. Rated Load Power Supply Voltage 2: 200 VAC 3. Rated Load Current 15: 15 A 25: 25 A 35: 35 A 45: 45 A 4. Terminal Type B: Screw terminals 5. Single-phase/3-phase and Number of Elements for 3-phase Blank: Single-phase models 6. Single-phase Type Blank: DIN track mounting and built-in heat sink 7. Certification VD: Certified by UL, CSA, and VDE Solid State Relays (Single-phase) G3PB J-37

Ordering Information List of Models Isolation method Zero cross function Note: When ordering, specify the rated input voltage. Operation indicator Accessories (Order Separately) Rated input voltage Rated output load Model number Phototriac coupler Yes Yes (yellow) 12 to 24 VDC 15 A, 100 to 240 VAC 215B-VD 12 to 24 VDC 25 A, 100 to 240 VAC 225B-VD 12 to 24 VDC 35 A, 100 to 240 VAC 235B-VD 12 to 24 VDC 45 A, 100 to 240 VAC 245B-VD 12 to 24 VDC Mounting Track 50 cm (1) x 7.3 mm (t) PFP-50N 1 m (1) x 7.3 mm (t) PFP-100N 1 m (1) x 16 mm (t) PFP-100N2 Specifications Ratings (at an Ambient Temperature of 25 C) Input Item Rated voltage Operating voltage range Rated input current Must operate voltage Must release voltage Insulation method Operation indicator Output 12 to 24 VDC 9.6 to 30 VDC 7 ma max. 9.6 VDC max. 1 VDC min. Phototriac Yellow LED Common Item 215B-VD 225B-VD 235B-VD 245B-VD Rated load voltage 100 to 240 VAC Load voltage range 75 to 264 VAC Applicable load current (See note.) 0.1 to 15 A 0.1 to 25 A 0.5 to 35 A 0.5 to 45 A Inrush current resistance (peak value) 150 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) Permissible I 2 t (half 60-Hz wave) 260 A 2 s 260 A 2 s 2,660 A 2 s Applicable load (with Class-1 AC resistive load) 3 kw max. (at 200 VAC) 5 kw max. (at 200 VAC) 7 kw max. (at 200 VAC) 9 kw max. (at 200 VAC) Note: The applicable load current varies depending on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data. J-38 Solid State Relays (Single-phase) G3PB

Characteristics Item 215B-VD 225B-VD 235B-VD 245B-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC input) Release time 1/2 of load power source cycle + 1 ms max. (DC input) Output ON voltage drop 1.6 V (RMS) max. Leakage current 10 ma max. (at 200 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude (Mounted to DIN track) Shock resistance Destruction: 294 m/s 2 (DIN track mounting) Ambient temperature Operating: 30 C to 80 C (with no icing or condensation) Storage: 30 C to 100 C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Certified standards UL508 File No. E64562 CSA22.2 No. 14 File No. LR35535 IEC947-4-3 File No. 6825 UG Weight Approx. 240 g Approx. 240 g Approx. 400 g Approx. 400 g Solid State Relays (Single-phase) G3PB J-39

Engineering Data Load Current vs. Ambient Temperature 215B-VD 225B-VD 235B-VD 245B-VD Load current (A) 225B-VD Load current (A) 235B-VD 245B-VD 215B-VD Ambient temperature ( C) Close Mounting (3 Relays, 8 Relays) 215B-VD Ambient temperature ( C) 225B-VD Load current (A) 3 Relays Load current (A) 3 Relays 8 Relays 8 Relays Ambient temperature ( C) 235B-VD Ambient temperature ( C) 245B-VD Load current (A) 3 Relays 8 Relays Load current (A) 3 Relays 8 Relays Ambient temperature ( C) Close Mounting Example Ambient temperature ( C) DIN track J-40 Solid State Relays (Single-phase) G3PB

Input Voltage vs. Input Current and Input Voltage vs. Input Impedance Input impedance (kω) Input current (ma) Input current Input impedance Input voltage (V) One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. 215B-VD 225B-VD 235B-VD 245B-VD Inrush current Inrush current Inrush current Energized time (ms) Energized time (ms) Energized time (ms) Solid State Relays (Single-phase) G3PB J-41

Dimensions Note: All units are in millimeters unless otherwise indicated. 215B-VD 225B-VD Two, M4 Two, 4.6 dia. 68 24 100 max. 90±0.2 80 Two, M3.5 4.2 6.3 Note: Without terminal cover. Mounting Holes 13±0.3 Elliptical hole: 4.6 x 5.6 22.5 max. Note: With terminal cover. 13±0.2 1 4.5 Terminal Arrangement/ Internal Circuit Diagram (+) A1 90±0.3 100 max. 83.2 88.6 Output side Trigger circuit Input circuit Input side Three, 4.5 dia. or M4 2 A2 ( ) 235B-VD 245B-VD Two, M5 4.6 dia. 68 24 100 max. 90±0.2 80 Two, M3.5 13.4 6.1 Note: Without terminal cover. Mounting Holes 25±0.3 Elliptical hole: 4.6 x 5.6 25±0.2 44.5 max. Note: With terminal cover. 1 4.5 Terminal Arrangement/ Internal Circuit Diagram (+) A1 90±0.3 100 max. 83.2 88.6 Output side Trigger circuit Input circuit Input side Two, 4.5 dia. or M4 2 A2 ( ) J-42 Solid State Relays (Single-phase) G3PB

Accessories (Order Separately) Mounting Tracks PFP-100N, PFP-50N PFP-100N2 4.5 7.3±0.15 35±0.3 4.5 27±0.15 35±0.3 27 24 29.2 16 15 25 25 25 25 15 (5) 10 10 15 25 25 1,000 (500) (see note) 10 (see note) Note: Values in parentheses indicate dimensions for the PFP-50N. 1,000 25 25 15 10 1 1.5 Solid State Relays (Single-phase) G3PB J-43

Safety Precautions Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Mounting Method Vertical Mounting Vertical mounting Relationship between s and Ducts Mounting surface Duct Height Countermeasure 1 Countermeasure 2 Duct or airflow obstruction G3PB Vertical direction Duct or airflow obstruction Mounting surface 50 mm max. (A height of no more than half the 's height is recommended) G3PB Mounting surface G3PB Airflow Horizontal Mounting Panel Do not surround the with ducts, otherwise the heat radiation of the will be adversely affected. Use short ducts. If the ducts cannot be shortened, place the on a metal base so that it is not surrounded by the ducts. Ventilation Note: Make sure that the load current is 50% of the rated load current when the G3PB is mounted horizontally. Close Mounting Mounting Pitch Panel Mounting Duct or airflow obstruction Close mounting Mounting direction Vertical direction 80 mm min. 10 mm min. Panel Between duct or airflow obstruction and 60 mm min. Host and slave 30 mm min. G3PB Air inlet Be aware of air flow Duct or air flow obstruction G3PB Ventilation outlet G3PB If the air inlet or air outlet has a filter, clean the filter regularly to prevent it from clogging and ensure an efficient flow of air. Do not locate any objects around the air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel. A heat exchanger, if used, should be located in front of the Units to ensure the efficiency of the heat exchanger. Please reduce the ambient temperature of s. The rated load current of an is measured at an ambient temperature of 25 or 40 C. An uses a semiconductor in the output element. This causes the temperature inside the control panel to increase due to heating resulting from the passage of electrical current through the load. To restrict heating, attach a fan to the ventilation outlet or air inlet of the control panel to ventilate the panel. This will reduce the ambient temperature of the s and thus increase reliability. (Generally, each 10 C reduction in temperature will double the expected life.) Load current (A) 15 A 25 A 35 A 45 A Required number of fans 0.23 0.39 0.54 0.70 per Example: For 10 s with load currents of 20 A, 0.23 x 10 = 2.3 Thus, 3 fans would be required. Size of fans: 92 mm 2, Air volume: 0.7 m 3 /min, Ambient temperature of control panel: 30 C If there are other instruments that generate heat in the control panel other than s, additional ventilation will be required. J-44 Solid State Relays (Single-phase) G3PB

Wiring When using crimp terminals, refer to the terminal clearances shown below. Output Terminal Section (Single-phase Models) 15-A and 25-A Models 35-A and 45-A Models 10 13 Input Terminal Section 7.0 12.4 12.9 10 M4 (15 A, 25 A) M5 (35 A, 45 A) M3.5 Make sure that all lead wires are appropriate for the current. Output terminals are charged even when the Relay is turned OFF. Touching the terminals may result in electric shock. To isolate the Relay from the power supply, install an appropriate circuit breaker between the power supply and the Relay. Be sure to turn OFF the power supply before wiring the Relay. Tightening Torque Refer to the following and be sure to tighten each screw of the Relay to the specified torque in order to prevent the Relay from malfunctioning. Item Screw terminal Tightening torque diameter Input terminal M3.5 0.8 N m Output terminal M4 1.2 N m M5 2.0 N m Solid State Relays (Single-phase) G3PB J-45

J-46 Solid State Relays (Single-phase) G3PB

Solid State Contactors (Three-phase) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications. A comprehensive lineup that now includes 480-VAC models. Slim design with 3-phase output and built-in heat sinks. New heat sink construction with smaller mounting section. DIN track mounting supported as standard. (Screw mounting is also possible.) Certified by UL, CSA, and VDE. Model Number Structure Model Number Legend @@@-@@-@ 1 2 3 4 5 6 7 1. Basic Model Name G3PB: Solid State Relay 2. Rated Load Power Supply Voltage 2: 200 VAC 5: 480 VAC 3. Rated Load Current 15: 15 A 25: 25 A 35: 35 A 45: 45 A 4. Terminal Type B: Screw terminals 5. Single-phase/3-phase and Number of Elements for 3-phase 2: 3-phase, 2-element models 3: 3-phase, 3-element models 6. 3-phase Type N: DIN track mounting and built-in heat sink 7. Certification VD: Certified by UL, CSA, and VDE Solid State Contactors (Three-phase) G3PB J-47

Ordering Information List of Models (Built-in Heat Sinks) Applicable phase Main circuit voltage Note: When ordering, specify the rated input voltage. Zero cross function Applicable heater capacity (with Class-1 AC resistive load) Number of poles 3 100 to 240 VAC Yes 5.1 kw max. (15 A) 3 215B- 2 215B- 8.6 kw max. (25 A) 3 225B- 2 225B- 12.1 kw max. (35 A) 3 235B- 2 235B- 15.5 kw max. (45 A) 3 245B- 2 245B- 200 to 480 VAC 12.5 kw max. (15 A) 3 515B- 2 515B- 20.7 kw max. (25 A) 3 525B- 2 525B- 29.0 kw max. (35 A) 3 535B- 2 535B- 37.4 kw max. (45 A) 3 545B- 2 545B- Model J-48 Solid State Contactors (Three-phase) G3PB

Specifications Ratings (at an Ambient Temperature of 25 C) Operating Circuit (Common) Item Rated voltage Operating voltage range Rated input current (Impedance) Must operate voltage Must release voltage Insulation method Operation indicator Common 12 to 24 VDC 9.6 to 30 VDC 10 ma max. (at 24 VDC) 9.6 VDC max. 1 VDC min. Phototriac coupler Yellow LED Main Circuit of Models with Built-in Heat Sinks Item Rated load voltage Load voltage range Applicable load current (See note.) Inrush current resistance (peak value) Permissible I 2 t (half 60-Hz wave) Item Rated load voltage Load voltage range Applicable load current (See note.) Inrush current resistance (peak value) Permissible I 2 t (half 60-Hz wave) 215B- 100 to 240 VAC 75 to 264 VAC 215B- 225B- 225B- 235B- 235B- 245B- 0.2 to 15 A 0.2 to 25 A 0.5 to 35 A 0.5 to 45 A 150 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) 260 A 2 s 2,660 A 2 s 2,660 A 2 s 515B- 200 to 480 VAC 180 to 528 VAC 515B- 525B- 525B- 535B- 535B- 545B- 0.5 to 15 A 0.5 to 25 A 0.5 to 35 A 0.5 to 45 A 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) 260 A 2 s 1,040 A 2 s 1,040 A 2 s 245B- 545B- Note: Applicable load current varies depending on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data. Solid State Contactors (Three-phase) G3PB J-49

Characteristics Models with Built-in Heat Sinks Item Operate time Release time Output ON voltage drop Leakage current (See note.) Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature 215B- 215B- Note: The leakage current of phase S will be approximately 225B- 225B- 1/2 of load power source cycle + 1 ms max. (DC input) 1/2 of load power source cycle + 1 ms max. (DC input) 1.6 V (RMS) max. 10 ma (at 200 VAC) 100 MΩ min. (at 500 VDC) 2,500 VAC, 50/60 Hz for 1 min 235B- 235B- Destruction: 10 to 55 to 10 Hz, 0.175-mm single amplitude (Mounted to DIN track) Destruction: 294 m/s 2 (98 m/s 2 with reverse mounting) Operating: 30 C to 80 C (with no icing or condensation) Storage: 30 C to 100 C (with no icing or condensation) 3 times larger if the 2-element model is applied. 245B- Ambient humidity Operating: 45% to 85% Weight Approx. 1.25 kg Approx. 1.45 kg Approx. 1.65 kg Approx. 2.0 kg Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3); Certified by VDE (From April 2001) EMC Emission EN55011 Group 1 Class B Immunity ESD IEC947-4-3, EN61000-4-2 4 kv contact discharge 8 kv air discharge Immunity Electromagnetic IEC947-4-3, EN61000-4-3 10 V/m (80 MHz to 1 GHz) Immunity EFT IEC947-4-3, EN61000-4-4 2 kv AC power-signal line Immunity Surge transient IEC947-4-3, EN61000-4-5 Normal mode ±1 kv, Common mode ±2 kv Immunity RF disturbance IEC947-4-3, EN61000-4-6 10 V (0.15 to 80 MHz) Immunity Dips IEC947-4-3, EN61000-4-11 245B- J-50 Solid State Contactors (Three-phase) G3PB

Item Operate time Release time Output ON voltage drop Leakage current (See note.) Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature 515B- 515B- Note: The leakage current of phase S will be approximately 525B- 525B- 1/2 of load power source cycle + 1 ms max. (DC input) 1/2 of load power source cycle + 1 ms max. (DC input) 1.8 V (RMS) max. 20 ma (at 480 VAC) 100 MΩ min. (at 500 VDC) 2,500 VAC, 50/60 Hz for 1 min 535B- 535B- Destruction: 10 to 55 to 10 Hz, 0.175-mm single amplitude (Mounted to DIN track) Destruction: 294 m/s 2 (98 m/s 2 with reverse mounting) Operating: 30 C to 80 C (with no icing or condensation) Storage: 30 C to 100 C (with no icing or condensation) 3 times larger if the 2-element model is applied. 545B- Ambient humidity Operating: 45% to 85% Weight Approx. 1.25 kg Approx. 1.45 kg Approx. 1.65 kg Approx. 2.0 kg Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3); Certified by VDE (From April 2001) EMC Emission EN55011 Group 1 Class B Immunity ESD IEC947-4-3, EN61000-4-2 4 kv contact discharge 8 kv air discharge Immunity Electromagnetic IEC947-4-3, EN61000-4-3 10 V/m (80 MHz to 1 GHz) Immunity EFT IEC947-4-3, EN61000-4-4 2 kv AC power-signal line Immunity Surge transient IEC947-4-3, EN61000-4-5 Normal mode ±1 kv, Common mode ±2 kv Immunity RF disturbance IEC947-4-3, EN61000-4-6 10 V (0.15 to 80 MHz) Immunity Dips IEC947-4-3, EN61000-4-11 545B- Solid State Contactors (Three-phase) G3PB J-51

Engineering Data Load Current vs. Ambient Temperature Models with Built-in Heat Sinks 215B- 215B- 515B- 515B- 225B- 225B- 525B- 525B- 235B- 235B- 535B- 535B- 245B- 245B- 545B- 545B- Load current (A) 225B- 225B- 525B- 525B- Load current (A) 235B- 235B- 535B- 535B- 245B- 245B- 545B- 545B- 215B- 215B- 515B- 515B- Ambient temperature ( C) Ambient temperature ( C) Input Voltage vs. Input Current and Input Voltage vs. Input Impedance Input impedance (k Ω ) Input current (ma) Input current Input impedance Input voltage (V) One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. 215B- 215B- 225B- 225B- 515B- 515B- 525B- 525B- 235B- 235B- 535B- 535B- 245B- 245B- 545B- 545B- Inrush current Inrush current Inrush current Energized time (ms) Energized time (ms) Energized time (ms) J-52 Solid State Contactors (Three-phase) G3PB

Dimensions Note: All units are in millimeters unless otherwise indicated. 215B- 515B- 215B- 515B- 225B- 525B- Without Terminal Cover With Terminal Cover Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3.5 80.5 max. 100 max. Two, R2.3 mounting holes Six, M4 80 max. Terminal Arrangement/ Internal Connections @@@B- Mounting Hole Dimensions 30.5 max. Four, 4.5-dia. or M4 120 max. @@@B- Input circuit Input circuit Solid State Contactors (Three-phase) G3PB J-53

225B- 235B- 525B- 535B- Without Terminal Cover Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3.5 With Terminal Cover 80.5 max. 120 max. Two, R2.3 mounting holes Six, M5 (35 A type) Six, M4 (25 A type) 80 max. Terminal Arrangement/ Internal Connections @@@B- Mounting Hole Dimensions 30.5 max. Input circuit 120 max. @@@B- Four, 4.5-dia. or M4 Input circuit J-54 Solid State Contactors (Three-phase) G3PB

235B- 245B- 535B- 545B- Without Terminal Cover Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3.5 With Terminal Cover 80.5 max. 140 max. Two, R2.3 mounting holes Six, M5 80 max. Terminal Arrangement/ Internal Connections @@@B- Mounting Hole Dimensions 30.5 max. 120 max. @@@B- Four, 4.5-dia. or M4 Input circuit Input circuit Solid State Contactors (Three-phase) G3PB J-55

245B- 545B- Without Terminal Cover Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3.5 With Terminal Cover Two, R2.3 mounting holes 80.5 max. 140 max. Six, M5 Mounting Hole Dimensions 80 max. 110 max. Terminal Arrangement/ Internal Connections @@@B- 30.5 max. Input circuit 120 max. Four, 4.5-dia. or M4 J-56 Solid State Contactors (Three-phase) G3PB

Safety Precautions Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Mounting Method Since the Relay is heavy, firmly mount the DIN track and fix both ends with End Plates for DIN-track-mounting models. Applicable DIN Tracks The G3PB can be mounted to TH35-15Fe (IEC60715) DIN tracks. The manufacturers and models of DIN tracks to which mounting is possible are shown in the following table. Manufacturer Thickness 1.5 mm 2.3 mm Schneider AM1-DE200 --- WAGO 210-114, 210-197 210-118 PHOENIX NS35/15 NS35/15-2.3 Direct Mounting When mounting directly onto a panel, mount securely under the following conditions. Screw diameter: M4 Tightening torque: 0.98 to 1.47 N m Mounted State Vertical direction Vertical Mounting Close Mounting Mounting Pitch Panel Mounting Panel Note: Mount the G3PB so that the markings can be read. Mounting direction Vertical direction 80 mm min. Space between s Duct or airflow obstruction 10mm min. Horizontal Mounting Panel Note: When the G3PB is mounted horizontally, use at 50% of the rated load current. 80 mm min. 80 mm min. Between duct or airflow obstruction and Close mounting Relationship between s and Ducts Duct Height Countermeasure 1 Countermeasure 2 Mounting surface 150.5mm 150.5mm Ventilation Duct or airflow obstruction Vertical direction Duct or airflow obstruction Do not surround the with ducts, otherwise the heat radiation of the will be adversely affected. Air inlet If the air inlet or air outlet has a filter, clean the filter regularly to prevent it from clogging and ensure an efficient flow of air. Do not locate any objects around the air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel. A heat exchanger, if used, should be located in front of the Units to ensure the efficiency of the heat exchanger. Please reduce the ambient temperature of s. The rated load current of an is measured at an ambient temperature of 25 or 40 C. An uses a semiconductor in the output element. This causes the temperature inside the control panel to increase due to heating resulting from the passage of electrical current through the load. To restrict heating, attach a fan to the ventilation outlet or air inlet of the control panel to ventilate the panel. This will reduce the ambient temperature of the s and thus increase reliability. (Generally, each 10 C reduction in temperature will double the expected life.) Three-element Devices Load current (A) 15 A 25 A 35 A 45 A Required number of fans 0.70 1.06 1.63 2.09 per Two-element Devices Mounting surface Be aware of air flow Duct or air flow obstruction Use short ducts. 75mm max. (A height of no more than half the 's height is recommended) Ventilation outlet Airflow If the ducts cannot be shortened, place the on a metal base so that it is not surrounded by the ducts. Load current (A) 15 A 25 A 35 A 45 A Required number of fans 0.47 0.78 1.09 1.40 per Example: For 10 s with load currents of 11 A (3-element devices, 1.63 x 10 = 16.3 Thus, 17 fans would be required. Size of fans: 92 mm 2, Air volume: 0.7 m 3 /min, Ambient temperature of control panel: 30 C If there are other instruments that generate heat in the control panel other than s, additional ventilation will be required. Mounting surface Solid State Contactors (Three-phase) G3PB J-57

Wiring When using crimp terminals, refer to the terminal clearances shown below. Tightening Torque Refer to the following and be sure to tighten each screw of the Unit to the specified torque in order to prevent the Unit from malfunctioning. Output Terminals Input Terminals Item Screw terminal Tightening torque diameter Input terminal M3.5 0.59 to 1.18 N m Output terminal M4 0.98 to 1.47 N m M5 1.47 to 2.45 N m M4 (15 A, 25 A) M5 (35 A, 45 A) Make sure that all lead wires are thick enough for the current. Output terminals T1, T2, and T3 are charged regardless of whether the Unit is a 2- or 3-element model that is turned on or off. Do not touch these terminals, otherwise an electric shock may be received. To isolate the Unit from the power supply, install an appropriate circuit breaker between the power supply and Unit. Be sure to turn off the power supply before wiring the Unit. Terminal L2 and terminal T2 of the 2-element model are internally short-circuited to each other. Therefore, connect terminal L2 to the ground terminal side of the power supply. If terminal L2 is connected to a terminal other than the ground terminal, cover all the charged terminals, such as heater terminals, for the prevention of electric shock accidents and ground faults. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J135-E1-03 In the interest of product improvement, specifications are subject to change without notice. J-58 Solid State Contactors (Three-phase) G3PB