TECHNICAL INFORMATION Puissant 30-Watt Shortwave UV Light Sources Catalog Nos. SKSUV30, SKSUV40

Similar documents
ALU-29CF Portable Light NSN:

2. Description of Standard NUV Lightsource (350nm-450nm) 3 3. Description of Deep UV (220nm-280nm) and Mid UV (280nm-310nm) Lightsource Systems 3

OFK-8000A OPTIMAX Multi-Lite

Item #21483 LARGE VIEW AUTO DARKENING WELDING HELMET INSTRUCTIONS

OFK-300A OPTIMAX Multi-Lite

Q-Series Ultraviolet Lamps OPERATOR S MANUAL

Installation Instructions

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

ASSEMBLY INSTRUCTIONS

Ultraviolet Lamps. Compact UV Lamps. Handheld UV Lamps. Ultraviolet Lamps

UV-AIRE AIR PURIFYING SYSTEM

Item #21484 XL VIEW AUTO DARKENING WELDING HELMET INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Submersible Pond Pump with UV 800 Gallons Per Hour

WELDING HELMET INSTRUCTIONS. Part #20520

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

ATTACH YOUR RECEIPT HERE ITEM # FT. PRE-LIT DOUGLAS FIR TREE. MODEL #DF-75C85 Español p. 8

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

4000 SYSTEM OPERATING MANUAL

Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight

CeraLux Lamp Module Assembly Instructions

CeraLux Lamp Module Assembly Instructions

Troubleshooting Guide: 355 Lights (24V)

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

ASSEMBLY INSTRUCTIONS PRODUCT CODE: CAUTION: Carefully Read Instructions and Procedures for Safe Operation. 7' Diamond Peak LED Tree

ULTRAVIOLET LAMPS. PL Series UV Hand Lamps. Compact UV Lamps. Handheld UV Lamps

Troubleshooting Guide: 355 Lights (12V)

DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual

LyteLaunch Dry - Wet and DMX Models. Operation Manual

PORTABLE 2 UV CURING SYSTEM OPERATING INSTRUCTIONS

OPK-300N OPTIMAX Multi-Lite

WARNING Risk of property damage, injury, or death.

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

30W High Stability Tungsten- Halogen Light Source - ASB-W Operation Manual

I1 7.5 Pre-Lit Clear Christmas Tree

Installation Instructions

LS-1 Series Tungsten Halogen Light Sources

INSTALLATION AND USER INSTRUCTIONS

Model AERO-24. Model ADHO24-4. Model AD24-2

7.5' LED Silver Glitter with Pinecones One Plug Tree V INSTRUCTION MANUAL

Sylvania 7.5 Pre-Lit Lindberg Pine Tree 500 Clear Incandescent Lights-One Plug Tree Tree ID #C15, Item # V

Crime-lite 2. a new and improved range of forensic light sources

Installer s Manual. PCO/UV N-Duct Model

BL7000 SYSTEM OPERATING MANUAL

21", 33", 45", & 61" Installation & Operation Manual

7.0 Aspen Pine SYLVANIA Power-Lit TM M5 Warm White LED Pre-Lighted Tree V

Riverside. Placid Cove Entertainment PIER Assembly Instructions. Pier Left & Right Item # THANK YOU FOR YOUR PURCHASE.

Flashlights Unlimited Xenopus Electronix Deep Purple 405 Premium Inspection Lantern Operations Guide

INSTALLATION INSTRUCTIONS

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

HARDWARE KIT INSTALLATION GLOVES

9' Warm White /Multi LED Color Changing M5 One Plug tree V INSTRUCTION MANUAL

UV Transilluminator Dual Wavelength (Large)

NANOpure Infinity UV Module Upgrade

Safety, Installation and Service Manual Models 1952, 1953 & 1972

5.5 FT PRE-LIT SERBIAN SPRUCE TREE

ROOM AIR SANITIZER GERMICIDAL ULTRAVIOLET ADVANTAGES OF THE SANITAIRE SYSTEM

EQUIPMENT OPERATION MANUAL. Loctite ZETA 7401 UV Chamber

Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL

Lambda HPX-L5. High-Power LED Light Source System (Air-Cooled with Liquid Light Guide) Operation Manual. Rev (( )

Submersible Pond Pump with UV 800 Gallons Per Hour

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

TWIN HALOGEN SHOP LIGHT

Installation Instructions

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

OPERATIONS AND MAINTENANCE MANUAL EcoStream Models ECS60R / ECS100R / ECS150R

Fiber Connector Shelf (CCS)

TECHNICAL MANUAL. FOR BLAST 2 (Bright Light Aiming System Tactical 2) For Rifles and Pistols Equipped with MIL-SPEC-1913 and Picatinny Rails

EQUIPMENT Operation Manual. Loctite Zeta 7401 UV Chamber Part Number 98039

HLS Watt Halogen Illuminator Service Manual

FOR INDOOR/SEASONAL USE ONLY

Energy efficient low voltage dichroic mirror halogen reflector lamps

SSX-180ST. SolarMaxx 180 Illuminator Service Manual

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

Operating Instructions August 2013

EQUIPMENT Operation Manual. Loctite Zeta 7411 UV Flood Curing System. Part Number 98027

1W Solar Powered LED Strobing Dock Light - Marine Applications - 24/7 Operation - Weatherproof

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166

Mini Convex HID Fog Lights

240 Watt Portable Work Area Light Tower - Extendable Tower W/ Wheels - (4) 60 Watt LED Lights

Square Solar Garden Light 95706

1W Solar Powered 24/7 LED Strobe Light - Marine Applications - Weatherproof - Permanent Mount

Operating Manual. Follow all safety precautions!

VH03 SAVE THESE INSTRUCTIONS

INSTALLATION TEMPLATE

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

AMCON AUTOMATIC CHART PROJECTOR USER S MANUAL EQ-6002

Deep UV Deuterium Light Source. Operation Manual

Conduit ~15" Inlet. UV Sterilizer - Connection to Forcemain

UView Mini Transilluminator

Multi-Vapor Metal Halide Lamps

PHOTO-CATALYTIC AIR PURIFIER SYSTEMS

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

UV Flood Curing System

XPERT SL 45 Slit Lamp. Instruction Manual

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Sylvania 7.5' Pre-Lit Troy Fir Tree LED Color Changing and Multi Function One Plug Tree Tree ID #T1, Item # V

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

Transcription:

SIRCHIE Products Vehicles Training Copyright 2012 by SIRCHIE All Rights Reserved. TECHNICAL INFORMATION Puissant 30-Watt Shortwave UV Light Sources Catalog Nos. SKSUV30, SKSUV40 INTRODUCTION The SKSUV30 and SKSUV40 lamps provide high intensity shortwave (254nm) illumination for searching for untreated latent fingerprints. Two 15-watt germicidal lamps provide a full 30 watts of shortwave UV light. The SKSUV30 is equipped with a shortwave filter that blocks visible light, while the SKSUV40 is supplied without the filter. A sturdy base provides self-support for hands-free operation. This light is ideal for searching large areas or for outdoor use during daylight hours. Each unit features dual voltage capability for either 110V or 220V AC operation. It is especially useful when used as a companion to the KRIMESITE IMAGER. The Puissant lamp may be transported or stored in its durable molded carrying case. Please read through this entire Technical Information Sheet before attempting to use this device. No. SKSUV40 No. SKSUV30 100 HUNTER PLACE, YOUNGSVILLE, NC 27596 USA Ph: (919) 554-2244, (800) 356-7311 Fax: (919) 554-2266, (800) 899-8181 Web: www.sirchie.com Email: sirchieinfo@sirchie.com 1 of 8

FIGURE 1 PROCEDURE The Puissant Lights operate from a standard AC power source. A sensor built into the lamp circuitry detects whether the power source is 110V AC or 220V AC, and automatically switches to the proper power configuration (220V AC cord adapter is not included). A single, rocker-type ON/OFF switch controls the bulbs. After being certain that all safety precautions have been taken, and that all those present are wearing the necessary protective gear, plug the power cord into the nearest power outlet, direct the lamp toward the area to be searched, and switch it on. Visible light may be seen when the lamp is on, but you should not look directly into the lamp. The lamp may be carried around the area being searched using the carrying handle, or it may be placed on a flat, level surface (Fig. 1). To avoid unnecessary exposure to the UV radiation, all of those present should remain behind the light source. SPECIAL PRECAUTION: Avoid the use of shortwave UV light (254nm) in the presence of visible bloodstains if subsequent DNA analysis is a consideration. Collect blood samples prior to shortwave UV light exposure. TROUBLESHOOTING Lamp Does Not Illuminate or Illumination Is Intermittent 1. Check for worn, frayed or loose power cord. Be certain the power outlet is working. 2. Check for a loose or blown line fuse. 2 of 8

3. Check for loose or broken bulbs, especially if the unit has been dropped or has received a sever shock (see Maintenance for instructions on bulb access and replacement). MAINTENANCE Fuse, bulb and filter replacement is the ONLY maintenance to be done by the end-user. Bulb Replacement: 1. Disconnect the lamp from the AC power source. 2. Place the unit on a flat surface with the power switch facing down. Remove the four (4) retaining screws on both sides of the unit that secure the filter assembly to the lamp housing (Fig. 2). NOTE: Do not remove the four screws on the front (filter side) of the unit. 3. Carefully remove the filter assembly and set it aside. 4. The bulbs are fitted with standard fluorescenttype terminals on each end. Grasp a bulb, twist in either direction, and lift it up to remove it from the end connectors (Fig. 3). 5. Place the new bulb into the end connectors and twist in either direction until the bulb snaps into place. FIGURE 3 FIGURE 2 3 of 8

6. Replace the filter cover and secure it with the four screws, but do not over tighten. The unit is now ready for use. Filter Replacement: 1. Disconnect the lamp from the AC power source. 2. Place the unit on a flat surface with the power switch facing down. Remove FIGURE 4 FIGURE 5 the 4 retaining screws from the sides of the unit (refer Fig. 3). Lift the filter assembly from the unit and place it on a flat surface filter side up. While supporting the underside of the filter assembly with one hand, remove the four (4) screws from the front of the unit (Fig. 4). Lower the filter and its retaining bracket to the work surface and set the cover aside. The glass filter is now exposed. Carefully remove the cracked or broken filter and discard. Remove any glass shards that have fallen into the unit as well. 3. Place the new filter, rough side facing out, into the retaining bracket as shown in Figure 5. Reassemble the filter assembly and secure it with the four (4) screws from the front of the unit, but do not over tighten. Fit the filter assembly on the lamp housing and reinstall the 4 retaining screws without over tightening. The unit is now ready for use. 4 of 8

Fuse Replacement 1. Disconnect from power source. To remove the line fuse, grasp the fuse holder, push in and twist counter-clockwise. Pull the fuse out of the lamp housing. 2. Replace the fuse with a 3AG 1 Amp, 250V fast-blo type. Reinsert the fuse into the housing, push in and twist until it locks. If replacing the lamps and/or the line fuse fails to solve the problem, please contact the factory for return authorization. Call Customer Service at (919) 554-2534. 5 of 8

SKSUV30/40 SPECIFICATIONS: Weight: 6.96 lbs. Unit Size: 4.5 W x 4 D x 19.75 H Unit Base: 7.625 W x 8.625 D x 12 H UV Lamps: 2x 15-watt Power Requirements: 110V or 220V AC, fused SKSUV30/40 Contents: 1- Puissant UV Light Source, SKSUV30 or SKSUV40 2-797GV Protective Spectacles 1- Durable Molded Carrying Case; Dimensions: 29 W x 17 H x 12 D; Weight: 14.51 lbs. 6 of 8

Precautions: ultraviolet radiation The three areas of ultraviolet radiation are UV-C at 100 to 280nm, UV-B at 280 to 315nm, and UV-A at 315 to 400nm. UV-C is the shortest wave ultraviolet radiation and UV-A is the longest wave ultraviolet radiation. The retina of the eye is not very vulnerable in the ultraviolet or the far-infrared portions of the spectrum. It is the cornea and the lens that absorb ultraviolet. High exposure levels can permanently damage these structures of the eye. Intermediate levels in the UV (200-320nm) cause greater injury to the cornea, which is severe but temporary. The injury, photokeratitis, may last for only one or two days but is extremely painful. Near-ultraviolet (long wavelength UV-A) is absorbed heavily in the lens of the eye. Damage to this area of the eye may not be evident for many years and may have lasting effects. Human skin is also susceptible to radiation injury. This susceptibility occurs in the range of radiant energy present in the ultraviolet spectral region of 200-320nm. This type of radiation can cause severe sunburn. Certain photosensitizing chemicals greatly increase the sensitivity of the skin. Previous exposures to specific wavelength bands that are generally in the long wavelength ultraviolet and visible portion of the spectrum also sensitize the skin. Some orally administered drugs such as tetracyclines and common pain relievers also cause photosensitization. The factors predisposing individuals to possible harm from ultraviolet radiation are: Sensitivity of the individual The length of exposure Intensity of the ultraviolet light source Light source/surface distance Recommended Personal Protective Equipment: UV absorbing face shield or glasses with side shields Long sleeved laboratory coat or overalls Opaque cotton or garamid fiber gloves SIRCHIE's shortwave UV lamps utilize low-pressure mercury lamps, which emit radiation in the UV-C (254nm) spectrum. Any amount of exposure to these lamps should be considered hazardous and protective equipment for the eyes and exposed skin must be worn. When using any UV lamp, avoid needless exposure to radiation and turn the lamp off when not in use. 7 of 8

SIRCHIE Products Vehicles Training 100 Hunter Place, Youngsville, NC 27596 USA 919-554-2244 800-356-7311 www.sirchie.com 8 of 8