Piston Metering Pump REKOS KR

Similar documents
Product Information Piston Dosing Pump FEDOS E/DX

Product Information Motor-driven Diaphragm Dosing Pumps MEMDOS E/DX

Piston Metering Pump FEDOS E / DX

Product Information Motor-driven Diaphragm Dosing Pumps MEMDOS E/DX

Primus 221 offers optimum dosing accuracy and operating convenience. The dosing flow variation is only ± 1,5 %

motor driven metering pumps

motor driven metering pumps

motor driven metering pumps

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

ProMinent Meta METERING PUMPS. ProMinent

Diaphragm Metering Pump MEMDOS E / DX

Dosing pump series G A

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

Identity code: Meta MTMa Diaphragm Metering Pumps Series: Meta diaphragm-type metering pump Version a

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

ProMinent Sigma/ 1 Motor Diaphragm Metering Pumps

ProMinent Hydro Hydraulic Diaphragm Metering Pumps

M E T E R I N G P U M P S

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

SOLENOID DRIVEN DOSING PUMPS MX series

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

GRUNDFOS DATA BOOKLET. DMX and DMH. Dosing pumps

GRUNDFOS DATA BOOKLET. DMX and DMH. Dosing pumps

GRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids

A CATALOUGE FOR MPH HYDRAULIC DIAPHRAGM METERING PUMP SIKO PUMP. Factory Warranty. Food & Beverage. Mining. Paints & Dyes.

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers

ProMinent EXtronic Solenoid Diaphragm Metering Pumps

ProMinent EXtronic Solenoid Diaphragm Metering Pumps

DIAPHRAGM METERING PUMPS

ProMinent Sigma/ 2 Motor Diaphragm Metering Pumps

Air Inlet/ Discharge Port

Our vision is to be the first choice in the needs of our customers that we see as business partners and to serve without sacrificing quality.

ASV Eccentric Pumps Type F and Type L

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps

IN USA FAX:

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

An IDEX Water & Wastewater Business. pulsafeeder.com. Mechanical Diaphragm Metering Pump

DSD Technology Reinventing metering pumps Dynamic Stiffness Diaphragm - High hydraulic performance

NOVADOS Metering Pumps

Centrifugal pumps. made of Polypropylene and PVDF for transferring aggressive media like acids and alkalies

S300 L series positive displacement metering pump

Encore 700 Diaphragm Metering Pump

Mechanical Diaphragm Metering Pump

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

KNIFE GATE VALVES -- MODEL A

ProMinent Pro M inent Sigma/ 3 Diaphragm Meter ing Pu mps. Diaphragm Rupture Warning System

NOVADOS Metering Pumps

Metal tube variable area flowmeter for gases, liquids and steam

Milroyal C. PD 3661 Effective 6/2009. MilRoyal C

ELADOS EMP IV E00 Diaphragm Pump type

An IDEX Water & Wastewater Business. pulsafeeder.com. PL Series Plunger Metering & Process Pumps

Data Sheet 10/ EN November 2004

Please affix device label here!

Angle Seat Valve /2" up to 3"

mroy Series Hydraulic Diaphragm Metering Pumps

ProMinent delta Solenoid Diaphragm Metering Pumps

solenoid driven diaphragm type metering pump

ELADOS EMP-KKS Diaphragm Piston Pump Type

ENCORE 700 DIAPHRAGM METERING PUMP

A measured step forward Dosing pumps and accessories

Pressure transmitter for industrial applications Type MBS 4510

ABEL HMT/HMQ. Hydraulic Diaphragm Pumps Pumping large volumes of abrasive fluids against high pressures

OMG. DOXE metering pumps

WATER PROCESS SOLUTIONS

PRESS P/N - P/N ECO SERIES

Pro M i n e nt Sigma/ 2 Diaphragm Meter i ng Pu mps

KNIFE GATE VALVES -- MODEL D

IWAKI METERING PUMPS AX

Thermoplastic Centrifugal pump, Type NM

Hydraulic Diaphragm Metering Pump Orlita Evolution 1

Thermoplastic Centrifugal Pump Type NMB-S

Security device Non return valve

ProMinent Beta Solenoid Diaphragm Metering Pumps

LUBRICATION PUMP UCD

Technical Principles of Valves

ARBO. ARBO Chemical pumps. Pompen en Filters b.v. DIN-EN ISO 2858 with mechanical seal. Product group 1.0

Ball valve C 200 PROP / C 200 DOS

Jaeco AgriPumps for Chemigation

KOSO HAMMEL DAHL. Specifications. Body Size: Globe - 1/2" through 6" ( mm). Angle - 1/2" through 2" (15-50 mm).

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Modulating control valve PN16 with magnetic actuator

DDA AR-PVC/V/C with access.

Diaphragm valve MV 309

SCHMITT. product information. Kreiselpumpen. U Pump Series. normal priming, centrifugal pumps with a single mechanical seal.

2/2 Pressure operated valves

ELADOS EMP III Diaphragm Pump type

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR

Pressure transmitters for industrial applications Type MBS 4510

Pulsation Dampeners (Chargeable-Adjustable)

Chemical Motor Pump Unit BN

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

series2500 TEXSTEAM Pumps ELECTRIC DRIVEN INJECTION PUMP PRODUCT FEATURES MODEL DESIGNATION

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

VZO Pressure drop curves See Meter data. Option: Reed pulser or RV / IN pulser

ProMinent. 1.1 ProMinent: Innovations In Chemical Feed Technology ProMinent Dosing Dosierstation Station: Comprehensive

Dry installed end-suction pumps, LSN-series. according to ISO 2858 / ISO 5199

Hydraulic Diaphragm type Metering Pump

Excel AD Electromagnetic dosing pump

HYDRAULIC SERIES METERING PUMPS

Transcription:

MB 08 02 / General Rekos pumps can be supplied as simplex piston metering pumps type KR and duplex piston metering pumps type ZKR. Advantages of piston metering pumps are: minor dependency on back pressure and linear flow variation as a function of the stroke length. The metering pumps are therefore very suitable for proportional metering where the stroke length is adjsuted by means of a remote control signal. Standard versions have the metering head on the lefthand side. Type KR...L (Symbol ) Upon request metering pumps are available with the metering head on the right-hand side. Type KR...R (Symbol ) For duplex metering pumps, the heads may be combined as listed in the below tables. Depending on the head size they are arranged in parallel (Symbol ) or diagonally (Symbol ) Type code ZKR.../... Metering head Metering heads are supplied in plastic for max. 0 bar and in stainless steel for up to 200 bar. The correct choice of the metering heads depends on the aggressivity of the chemical, its temperature and viscosity, and on the system pressure. Environmental factors (harsh operating conditions, radiant heat) must also be considered. Suction and discharge valves Suction and discharge valves can be supplied as double-ball valves, spring-loaded single-ball valves or disk valves, depending on the size. Spring-loaded valves are recommended if the viscosity of the chemical exceeds 00 mpas. Technical data Flushing attachment Metering heads are generally fitted with a flushing attachment. Flushing water should be applied if the chemical being used is very aggressive, to prevent damage by corrosion from leakage that is bound to occur. If the medium used is abrasive, the flushing water is intended to prevent the piston and packing from failing after only a short time of operation as a result of intensified leakage. The flushing water pressure should,in this case, be greater than that of the medium. REKOS KR 8 20 0 0 7 2 80 29 20 72 Max. pressure Plastic 0 [bar] SS 200 90 0 9 0 0 20 2 0 Output at [l/h] 9 20 0 7 2 80 29 20 72 max. pressure [ml/stroke]... 6.8 2. 2.2 0. 0 7. 22 Piston ø [mm] 8 2 7 2 0 6 6 72 Stroke frequency [/min] 00 Suction lift [mbar] 20 Motor output [kw] 0. kw (0.7 kw with frequency converter) Metering Plastic 2 head SS 7 0 Simplex manual 2 26 27 gear ATE/ATP 7 8 9 Duplex manual 2 6 gear ATE/ATP 9 Weight [kg]

MB 08 02 / 2 Abrasive media Piston packings can be supplied as PTFE net packings or Aramid-kevlar packings. PTFE packings with the edges reinforced with Aramid are also available. The standard PTFE packing can be used with practically all chemicals at a pressure of up to 0 bar. Higher pressures may increase leakage. As far as abrasive media are concerned, and in the case of pressures much higher than 0 bar, it may be advisable to use Aramid-kevlar packings, if the chemical allows it. Aramid-kevlar is not resistant to concentrated acids or alkalis. If these substances are to be metered at higher pressures, the user should revert to the edge-reinforced PTFE packing, despite the intensified leakage that will occur, and apply flushing. Piston-diaphragm system KMS Three sizes of piston-diaphragm metering heads are also available. Their use is recommended where, dispite higher pressures, it is important to avoid leakage due to a toxic, aggressive or abrasive chemical being used. Piston-diaphragm metering heads are separated from the transmission lubricant, and have their own hydraulic system (glycerine). Piston-diaphragm metering heads can also be retrofitted to piston metering pumps already installed (see MB 0 0). Functional diagram Plunger disk Return spring for suction stroke Drive cam Eccentric serving as stroke limiter Drive cam moves freely until it reencounters plunger disk. Drive The drive is an oil-filled worm gear with a single-state down mechanism. The stroke is created by means of a drive cam moving back and forth a spring-loaded plunger to which the piston is fixed. The metering stroke is induced by the thrust of the drive cam, the suction stroke by the return spring. Length of stroke is determined by means of a plunger return stop, with a manually adjustable eccentric serving as a stroke limiter. The stroke length, which determines the flow rate, can be adjusted manually during operation in a range of between 0 and 00%. The standard version is equipped with a manual adjustment. Electrical (ATE) remote control adjustment equipment can be supplied on request. The drive motor is normally a three-phase motor. Controllable a.c. motors and explosion-proof motors can also be supplied. Through the combination of a controllable drive motor and a remotely controllable stroke length adjuster, the metering pump is provided with two independent means of adjustment control so that disturbance-variable feedforwarding is possible in automatic control systems. Optional components Stroke counting The metering pump can, on request, be equipped with an inductive scanning head for the eccentric shaft in order to count the number of strokes for batch processes. Metering head heating For fluids which are solid when cold the metering head can be fitted with warm water, steam or electrical heating. Thyristor controller For controlling the direct current drive. (See MB 20 0) For other accessories - see "Installation example". Performance curves Flow rate % 00 90 80 70 60 0 0 0 20 0 without back pressure with back pressure 0 0 20 0 0 0 70 80 90 00 6FDOH

MB 08 02 / Simplex pumps Left-hand version KR 8 L... KR 72 L KR 8 R... KR 72 R Right-hand version

MB 08 02 / Duplex pumps ZKR 8-7 / 8-7 ZKR 2-20 / 8-7 ZKR 20-72 / 8-7 ZKR 2-20 / 2-20 Installation example 9 7 6 8 2 ZKR 20-72 / 2-20 ZKR 20-20 / 20-72 With duplex pumps that have differently sized metering heads, the larger metering head is always positioned on the left (L) (other versions on request). Dimensions Pump A B C D Type -0 Plastic SS 0 0 Plastic SS 7 7 0 Plastic SS 8 Plastic SS 7 8 2 0 278 2 8 7 2 0 278 2 8 2-20 22 2 9 296 6 9 6 72 98 2 8 9 8 8 29 9 For dimension (L) see Table Legend Metering pump MB 08 02 2 Suction line MB 22 0 Electric agitator MB 6 0 Tank MB 20 0 Relief valve MB 2 0 6 Diaphragm shutoff valve MB 2 0 7 Injection nozzle MB 2 0 8 Pulsation dampener MB 27 0 9 Control unit

MB 08 02 / Selection tables To offer the user a large variety of different versions, JESCO metering pumps have been divided into the main functional groups. They can thus be assembled according to the user's individual requirements. The user can combine the pump from the following components: Drive 2 Motor Head Valves Connections The numbers shown on the pump drawing refer to the relevant selection tables. Pump type Gear with capacity adjustmen t manua l KR...L 27 27 27 276 277 278 279 280 KR...R 62 62 62 626 627 628 629 60 2 6 7 8 9 0 2 6 9 60 6 62 ** For duplex pumps the metering heads can be of any combination. If they are of different sizes, the larger metering head is given the first in order. 8 2 A TE Combination of heads ** 6. 2, 8...7 2...20 72 ø 20 ø 00 j 6 ø 80 ø9 k6 or KMS I 0 ca. 272 or KMS I KMS III 20 M6 ( x) 2 E- Motor Part Conn. Voltage Curr.consumption Output Speed Frequency Classes Type No. mode V A kw /min Hz ISO Cl. IP AF 80 / A- 78629 D Y 20/00 2,6 /, 0, 90 0 F AF 80 / B- 7890 D Y 20/00, / 2,0 0, 7 00 0 F AF 80 / B- 78926 D Y 20/00, / 2,0 0, 7 00 0 F* * Motor fitted with cold-conductor thermometer probe.

MB 08 02 / 6 Pump- Piston Metering head material type KR d Plastic.7 Piston material Ceramic.7 8 8 298 2600 20 2 298 26009 0 298 260 0 7 2986 2607 7 2 296 2602 2 0 2962 2606 80 6 296 2602 29 6 296 2606 20 29870 26070 72 72 2968 26088 Pump Standard valves type KR KR 8...20 Double-ball KR 72 Spring-loaded with hastelloy spring Suction valve assembly Discharge valve assembly PVC.7 PVC.7 Seals of: Hypalon Viton It S Hypalon Viton Hypalon Viton It S Hypalon Viton 8... 7 887 88 26967 888 886 26968 2... 20 268 2682 2969 276 277 2969 72 270 270 270 268 270 270 270 268 Pump Spring-loaded valves with hastelloy spring type KR Suction valve complete Discharge valve complete PVC.7 PVC.7 Seals of: Hypalon Viton It S Hypalon Viton Hypalon Viton It S Hypalon Viton 8... 7 26 262 2877 276 277 28776 2... 20 268 2707 29696 27 27 29697

MB 08 02 / 7 Pump Dimensions Part No. type Version DN Pict. D di da L Plastic SS 6 A G / 6 2 97 A G / 6 980 6 A G / 6 8 0 289 6 B G / 6 2 0 22 6 B d 20 6 2 29 226 8 C G / 0 267 0 C G / 2 278 6 D G / G / 20 26 6 D d 20 G / 20 820 6 E d 20 8 20 279 8 E d 20 0 20 227 0 E d 20 2 20 228 0 B G / 9 292 292 B G / 6 2 0 296 29 0 C G / 6 22 27672 C G / 20 22 297 20 C G / 2 22 8 0 D G / G /8 22 290 2707 D G / G /2 22 29 29 20 D G / G / 22 27689 0 E G / 0 2926 E G / 8 299 F G / 296 297 2 B 68 2 9 20 206 2 C 68 2 0 288 2 C 68 0 0 29 20 D 68 G / 0 2076 206 2 D 68 G 0 288 2700 2 D 68 G / 0 222 2 E 68 28 60 2702 2 F 68 2 6 2622 262 KR 72 KR 2... 20 KR 8... 7 Order example Lime slurry is to be metered at a rate of 0 litres per hour against 20 bar. It is required that the metering pump is controlled via ph value so that an electrical stroke adjustment must be provided. The metering head is to be in the standard version, with left hand arrangement. Drive by 00 V phase motor. According to the corrosion resistance list, asbestos-free fiber (AF) is to be selected as the sealing material. Determination of type of metering pump Lime slurry, because of its suspended constituents, can have an abrasive effect and thus cause damage to standard piston metering pumps. Standard diaphragm pumps are not suitable here due to the operating pressure of 20 bar. Therefore a piston diaphragm metering pump must be chosen in this case. 2 A Tubing C Cemented D Threaded F Flange B Hose clamp C Cemented E Stainless steel pipe B Hose clamp D Threaded E Screwed (Ermeto) F Flange The electrically operated stroke length ajduster ATE is selected from table : According to MB 0 0, KMS size I is used for achieving the required flow rate. The appropriate drive system has Part No. 276. The motor required is the phase motor listed in table 2 under Part No. 78629. The metering head is to be ordered under the clear text as described in MB 0 0: KMS metering head size I for 0 l/h lime slurry at 20bar; stainless steel, Part No. 0292 Valves are to be selected from Table. Suction valve: Part No. 26967 Discharge valve: Part No. 26968 The s to be selected from Table are type D with G /. Part No. 2x 820

MB 08 02 / 8 General Metering pumps for use as a correcting element in control lines or automatic control systems are equipped with a servomotor: The stroke length can thus be adjusted by sensor contacts or controllers with a relay output. In the case of duplex pumps, each metering head may have a separate servomotor and can be adjusted independently. These pumps are described by the letters ATE used as a suffix after the type: e.g.: KR 0 L - ATE Mechanical manual adjustment of the pump with ATE drive is possible using a separate hand crank. Two models with different technical data are available (see pages 0 and ). On request, "increased safety" and "air-tight" explosionproof servomotors can be offered. Dimensions approx. Pump type KR A B C D E 8-7 0 29 70 92 80 2-20 200 02 00 0 0 72 20 07 0 0 For dimension L see table (MB 08 02 / 7) approx. Piston Piston Metering Metering Pump Pump REKOS REKOS KR-ATE Montagemaß Mounting dimension

MB 08 02 / 9 Technical data - types AR 0W2 and AR 0W2S Type AR 0W.. AR 0W..S Design Reversible a.c. motor with self-locking reduction gear. Use For controllers with switching For controllers with continuous output (-point control) output (2...0V or...20ma) Auxiliary voltage 20V~ ± % 2V ~ ± 20% 0...60 Hz 0...60 Hz Control 2...0V or...20ma Power consumption 2 W 7 W Regulating time/bevel 60s / 270 = 0...00% Position repeating signaling Potentiometer 0. W 0...620mV = 0...00% for remote display 0...000 Ω = 0...00% Limit switch Internal limit switch for limiting Internal limit switch for limiting the angle of rotation. the angle of rotation. Signaling of final position via terminals 6 and 7 Protection class IP (EN 6029) Ambient temperature -20... 60 C Option 2nd potentiometer 0...000 Ω 0. W Limit switches (2 off) max. 20V A Wiring diagrams Type AR 0W2 F00 20V~ and AR 0W2 F020 2V ~ Type AR 0W2S F020 2V~ 6 2 7 0 2 6 7 8 9 PE Open N Close 20 V~ E A M Position repeating signaling 0...kOhm Position repeating signaling 0...kOhm HE HA Volt.-free contacts max. 20 V~ A Piston Piston Metering Metering Pump Pump REKOS REKOS KR-ATE 2 2 V~ - + - +...20 ma 0...620mV

MB 08 02 / 0 Technical data - types WAN and WAN -S Type WAN WAN -S Design Reversible a.c. motor with self-locking reduction gear. Use For controllers with switching For controllers with continuous output (-point control) output 0()...20mA Auxiliary voltage 20V~ ± 0% 0...60 Hz 20V~ ± 0% 0...60Hz Other voltage on Control request. 0()...20mA Power consumption approx.. W Regulating time/bevel 60s / 270 = 0...00% Position repeating signaling Potentiometer 0. W 0()...20mA (only as an option) for remote display 0...000 Ω = 0...00% Limit switch Internal limit switch for limiting the angle of rotation. Signaling of final positions via terminals and Protection class IP according to DIN 000 Ambient temperature max. 60 C Option 2nd potentiometer 0...000 Ω 0. W Limit switches (2 off) max. 20V A Electrical wiring diagrams WAN WAN -S PE Open N Close 20 V~ E A 2 8 9 20 2 22 2 6 7 8 9 0 2902 Position repeating signaling kohm Position repeating signaling kohm Control by 20V/0...60 Hz supply voltage M Volt.-free contacts max. 20 V~ A Position repeating signaling 0()...20mA Piston Piston Metering Metering Pump Pump REKOS REKOS KR-ATE L N 2 20 V~ CLOSE OPEN - + Final position repeating signaling Conductance 0()...20mA Control by 0()...20mA standard signal